• Title/Summary/Keyword: Type specimens

Search Result 2,198, Processing Time 0.033 seconds

A comparative study on the correlation between Korean foods and the fractures of PFG and all ceramic crowns for posterior applications (구치용 도재소부금관과 전부도재관에 파절을 일으키는 한국음식에 관한 연구)

  • Kim, Jeong-Ho;Lee, Jai-Bong
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.47 no.2
    • /
    • pp.156-163
    • /
    • 2009
  • Statement of problem: Recently, there have been increased esthetic needs for posterior dental restorations. The failure of posterior dental ceramic restoration are possible not only by the characters of the component materials but also by the type of food. Purpose: The research aim was to compare the in vitro fracture resistance of simulated first molar crowns fabricated using 4 dental ceramic systems, full-porcelain-occlusal-surfaced PFG, half-porcelain-occlusal-surfaced PFG, Empress 2, Ice Zirkon and selected Korean foods. Material and methods: Eighty axisymmetric crowns of each system were fabricated to fit a preparation with 1.5- to 2.0-mm occlusal reduction. The center of the occlusal surface on each of 15 specimens per ceramic system was axially loaded to fracture in a Instron 4465, and the maximum load(N) was recorded. Afterwards, selected Korean foods specimens(boiled crab, boiled chicken with bone, boiled beef rib, dried squid, dried anchovy, round candy, walnut shell) were prepared. 15 specimens per each food were placed under the Instron and the maximum fracture loads for them were recorded. The 95% confidence intervals of the characteristic failure load were compared between dental ceramic systems and Korean foods. Afterwards, on the basis of previous results, 14Hz cyclic load was applied on the 4 systems of dental ceramic restorations in MTS. The reults were analyzed by analysis of variance and Post Hoc tests. Results: 95% confidence intervals for mean of fracture load 1. full porcelain occlusal surfaced PFG Crown: 2599.3 to 2809.1 N 2. half porcelain occlusal surfaced PFG Crown: 3689.4 to 3819.8 N 3. Ice Zirkon Crown: 1501.2 to 1867.9 N 4. Empress 2 Crown: 803.2 to 1188.5 N 5. boiled crab: 294.1 to 367.9 N 6. boiled chicken with bone: 357.1 to 408.6 N 7. boiled beef rib: 4077.7 to 4356.0 N 8. dried squid: 147.5 to 190.5 N 9. dried anchovy: 35.6 to 46.5 N 10. round candy: 1900.5 to 2615.8 N 11. walnut shell: 85.7 to 373.1 N under cyclic load(14Hz) in MTS, fracture load and masticatory cycles are: 1. full porcelain occlusal surfaced PFG Crown fractured at 95% confidence intervals of 4796.8-9321.2 cycles under 2224.8 N(round candy)load, no fracture under smaller loads. 2. half porcelain occlusal surfaced PFG Crown fractured at 95% confidence intervals of 881705.1-1143565.7 cycles under 2224.8 N(round candy). no fracture under smaller loads. 3. Ice Zirkon Crown fractured at 95% confidence intervlas of 979993.0-1145773.4 cycles under 382.9 N(boiled chicken with bone). no fracture under smaller loads. 4. Empress 2 Crown fractured at 95% confidence intervals of 564.1-954.7 cycles under 382.9 N(boiled chicken with bone). no fracture under smaller loads. Conclusion: There was a significant difference in fracture resistance between experimental groups. Under single load, Korean foods than can cause fracture to the dental ceramic restorations are boiled beef rib and round candy. Even if there is no fracture under single load, cyclic dynamic load can fracture dental posterior ceramic crowns. Experimental data with 14 Hz dynamic cyclic load are obtained as follows. 1. PFG crown(full porcelain occlusion) was failed after mean 0.03 years under fracture load for round candy(2224.8 N). 2. PFG crown(half porcelain occlusion) was failed after mean 4.1 years under fracture load for round candy(2224.8 N). 3. Ice Zirkon crown was failed after mean 4.3 years under fracture load for boiled chicken with bone(382.9 N). 4. Empress 2 crown was failed after mean 0.003 years under fracture load for boiled chicken with bone(382.9 N).

Adenoviral Lower Respiratory Tract Infections in Children; Serotypes and Clinical Characteristics (소아의 아데노바이러스 하기도 감염증: 혈청형 및 임상상)

  • Shin, Seon Hee;Lee, Hoan Jong;Yoon, Hae Sun
    • Pediatric Infection and Vaccine
    • /
    • v.9 no.2
    • /
    • pp.182-192
    • /
    • 2002
  • Purpose : This study was performed to characterize the epidemiologic and clinical features of acute adenoviral lower respiratory tract infections(LRTIs). Methods : Virological analysis was done from respiratory specimens obtained from patients with LRTIs hospitalized to other hospitals and referred to the Department of Pediatrics, Seoul National University Children's Hospital(SNUCH) from June 1998 to July 2000. Viral diagnosis was made by isolation of viruses employing HEp-2 cell culture and indirect immunofluorescent staining with monoclonal antibodies. Serotypes of adenoviruses were determined by neutralization test using antiserum for types 1, 2, 3, 4, 5, 6, 7 and 11. Medical records of children admitted to the SNUCH were reviewed retrospectively. Results : Adenovirus was isolated from 118(9.0%) of 1,305 children with LRTIs. Serotypes were 3(39.0%), 7(16.9%), 1(11.0%), 2(7.6%), 4(7.6%), 6(5.9%), 11(2.5%), and 5(0.8%) and 10 strains(8.5%) were not neutralized by antisera included in the study. Infections by type 3 and type 7 occurred in outbreaks. Male to female ratio was 1.0:0.9 and mean age was 1.95 years. The clinical diagnoses were pneumonia(83%), acute tracheobronchitis(12%) and bronchiolitis(5%). Associated symptoms, signs and abnormal laboratory findings included cough(100%), sputum(73.5%), fever(54.2%), rale(59.3%), wheezing(34%), anemia(35%) and leukopenia(15.8%). Mortality was in 13.5%. Residual radiologic sequelae was identified in 32.6% of the patients followed. Conclusion : These data confirms that adenovirus may cause severe lower respiratory tract diseases, and infections by type 3 and 7 may occured in outbreaks.

  • PDF

Morphometric Study on the Arterial Palmar Arch of the Hand (손바닥 동맥활에 관한 형태계측 연구)

  • Park, Bong Kwon;Jang, Soo Won;Choi, Seung Suk;Ahn, Hee Chang
    • Archives of Plastic Surgery
    • /
    • v.36 no.6
    • /
    • pp.691-701
    • /
    • 2009
  • Purpose: Deviations of arterial palmar arches in the hand can be explained on the embryological basis. The purpose of this study was to provide new information about palmar arches through cadaver's dissection. The values of the location and diameter in these vessels were analyzed in order to support anatomical research and clinical correlation in the hand. Methods: The present report is based on an analysis of dissections of fifty - three hands carried out in the laboratory of gross anatomy. A reference line was established on the distal wrist crease to serve as the X coordinate and a perpendicular line drawn through the midpoint between middle and ring fingers, which served as the Y coordinate. The coordinates of the x and y values were measured by a digimatic caliper, and statistically analyzed with Student's t - test. Results: Complete superficial palmar archs were seen in 96.2 % of specimens. In the most common type of males, the superficial arch was formed only by the ulnar artery. In the most common type of females, the superficial arch was formed anastomosis between the radial artery and the ulnar artery. The average length of the superficial and deep palmar arch is $110.3{\pm}33.0mm$ and $67.9{\pm}14.0mm$ respectively. Regarding the superficial palmar arch, ulnar artery starts $-16.1{\pm}5.1mm$ on X - line, and $2.5{\pm}24.5mm$ on Y - line. Radial artery appears on palmar side $7.7{\pm}3.2mm$ on X - line, and $20.9{\pm}10.9mm$ on Y - line. But radial artery starts on $6.3{\pm}3.6mm$ on X - line, and $3.4{\pm}5.1mm$ on Y - line. Digital arteries of superficial palmar arch starts on $6.1{\pm}3.7mm$, $33.9{\pm}8.8mm$ on index finger, $1.8{\pm}3.4mm$, $40.1{\pm}7.3mm$ on middle finger, $-3.2{\pm}4.9mm$, $42.6{\pm}7.0mm$ on ring finger, and $-8.9{\pm}5.1mm$, $42.5{\pm}80mm$ on little finger in respective X and Y coordinates. Radial artery of deep palmar arches measured at the palmar side perforating from the dorsum of hand. It's coordinates were $9.7{\pm}4.8mm$ on X - line, $21.7{\pm}10.2mm$ on Y - line. Ulnar artery was measured at hypothenar area, and it's coordinates were $-20.4{\pm}6.3mm$ on X - line, and $30.6{\pm}7.4mm$ on Y - line. Conclusions: Anatomically superficial palmar arch can be divided into a complete and an incomplete type. Each of them can be subdivided into 4 types. The deep palmar arch is less variable than the superficial palmar arch. We believe these values of the study will be used for the vascular surgery of the hand using the endoscope and robot in the future.

Evaluation of In-Vitro Efficacy of Active Ingredients in Dentifrice Used for Different Treatment Times (치약용 약효제의 적용시간에 따른 실험실적 효능 연구)

  • Ahn, Jae-Hyun;Kim, Ji-Hye;Kim, Ji-Young
    • Journal of dental hygiene science
    • /
    • v.16 no.2
    • /
    • pp.176-182
    • /
    • 2016
  • The purpose of this study was to evaluate the in-vitro efficacy of the active ingredients of dentifrice following treatment time. The whitening effect was evaluated by a change in lightness value relative to the contact time of hydrogen peroxide, by using artificially stained hydroxyapatite discs. The anti-calculus effect was assessed based on the amount of calcium eluted from the human dental calculus by sodium pyrophosphate. Remineralization was evaluated by the Vickers hardness test following the application of sodium fluoride to bovine enamel. In order to view dentinal tubules occlusion, the formation of insoluble calcium salts by bovine dentin specimens was observed using scanning electron microscopy. Change in lightness value (${\Delta}L$) was $5.50{\pm}1.51$ after 1 min of treatment, $5.73{\pm}0.43$ after 3 min, $8.64{\pm}0.24$ after 10 min, $18.93{\pm}0.76$ after 30 min, and $27.35{\pm}0.54$ after 60 min. The amount of calcium eluted from the human dental calculus was $4.23{\pm}0.14ppm$ after 1 min of treatment, $4.51{\pm}0.04ppm$ after 3 min, $12.12{\pm}0.16ppm$ after 10 min, $17.85{\pm}0.81ppm$ after 30 min, and $25.15{\pm}0.32ppm$ after 60 min. The Vickers hardness change value (${\Delta}VHN$) was $1.96{\pm}1.44$ after 1 min, $1.52{\pm}1.06$ after 3 min, $9.06{\pm}0.15$ after 10 min, $10.83{\pm}5.13$ after 30 min, and $12.55{\pm}2.09$ after 60 min. Partial dentinal tubules occlusion was observed at 10 min and complete occlusion was evident at 60 min. In summary, the use of patch type dentifrices for 10, 30, or 60 min were 1.57 to 8.26 times more effective than using the paste type dentifrices for 1 to 3 min. Based on these findings, it is reasonable to expect that the use of patch type dentifrices for 10 min would lead to remineralization, anti-calculus and dentinal tubules occlusion effects, and that use for 30 min would result in a whitening effect.

Periodontal Tissue Response Following Different Types of Fixed Retainers in Young Adult Dogs (수종의 고정성 보정장치에 따른 유성견의 치주조직 반응)

  • Jo, Myung-Hun;Yoon, Young-Jooh;Kim, Kwang-Won
    • The korean journal of orthodontics
    • /
    • v.31 no.1 s.84
    • /
    • pp.85-95
    • /
    • 2001
  • The purpose of this study was to evaluate the material for fixed type retainer, allowing physiologic tooth movement. and proper remodeling or periodontal tissue during retention period. The Present study was Performed to observe the histologic changes of periodontal tissue after application of different types of fixed type retainer after orthodontic tooth movement in young adult dogs. For this study, 4 young adult dogs were used as a experimental animal and experimental group was divided into three groups : experimental group 1 contained right side maxillayy third incisors and canines, experimental group 2 contained contralateral teeth of same animals, and control group contained mandibular premolars. And each dogs were applied the 4 different types of fixed type retainer to experimental group 1. The experimental teeth were ligated on the Sentalloy closed coil $spring^{\circledR}$(Tomy Co., Japan) from maxillary third incisors and canines and applied orthodontic force at initial 200gm-forced during 1 week. All the experimental animals were sacrificed on the 3rd week after the orthodontic teeth movement and then the specimens were taken, fixed in formalin, embeded in parafin, sectioned $6-8{\mu}m$ in thickness and stained with Hematoxylin-Eosin staining, and Masson's trichrome staining method. Examined under the light microscopy The following results were observed. 1. There were observed that decreased infiltration of giant tells in pressure side and increased the new bone forming in tension side on the specimen of 6-stranded 0.0195' $Respond^{\circledR}$(G&H Co., U.S.A.) group. Periodontal ligament fibers were much compressed or elongated in 3-stranded 0.018', 0.020' $Dentaflex^{\circledR}$(Dentarum Co., Germany), and Superbond $C&B^{\circledR}$(Sun Medical Co., Japan) groups. 2. In experimental group 1, necrotic bone inside the alveolar bone of pressure side, forming of the sharpey's fiber in osteoid tissue, and remodeling of the periodontal ligament were observed in all animals. 3. In experimental group 2, it was observed that the amount of bone resorption was equal or decreased in pressure side, and increased new bone forming and significantly decreased infiltration of giant cell than the experimental group 1. By this results, it considered that 6-stranded $Respond^{\circledR}$(G&H Co., U.S.A.) wire was the most useful material allowing early periodontal tissue remodeling.

  • PDF

Fracture resistance of zirconia and resin nano ceramic implant abutments according to thickness after thermocycling (지르코니아와 레진나노세라믹 임플란트 지대주의 두께에 따른 열순환 후 파절저항)

  • Lee, Jung-Won;Cha, Hyun-Suk;Lee, Joo-Hee
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.55 no.2
    • /
    • pp.144-150
    • /
    • 2017
  • Purpose: The aim of this in vitro study is to investigate load bearing capacity of esthetic abutments according to the type of material and wall thickness. Materials and methods: 70 specimens equally divided into seven groups according to their abutment wall thicknesses. The abutments prepared with titanium 0.5 mm wall thickness were used as a control group (Ti-0.5), whereas zirconia abutments and resin nano ceramic abutments with wall thickness 0.5 mm, 0.8 mm and 1.0 mm were prepared as test groups (Zir-0.5, Zir-0.8, Zir-1.0 and RNC-0.5, RNC-0.8, RNC-1.0). All specimens were tested in a universal testing machine to evaluate their resistance to fracture and all of them underwent thermo-cycling before loading test. Mean fracture values of the groups were measured and statistical analyses were made using two-way ANOVA. Results: Zir-1.0 showed the highest mean strength ($2,476.3{\pm}342.0N$) and Zir-0.8 ($1,518{\pm}347.9N$), Ti-0.5 ($1,041.8{\pm}237.2N$), Zir-0.5 ($631.4{\pm}149.0N$) were followed. The strengths of RNC groups were significantly lower compared to other two materials (RNC-1.0 $427.5{\pm}72.1$, RNC-0.8 $297.9{\pm}41.2$) and the strengths of all the test groups decreased as the thickness decreases (P < .01). RNC-0.5 ($127.4{\pm}35.3N$) abutments were weaker than all other groups (P < .05). Conclusion: All tested zirconia abutments have the potential to withstand the physiologic occlusal forces in anterior and posterior regions. In resin nano ceramic abutments, wall thickness more than 0.8 mm showed the possibility of withstanding the occlusal forces in anterior region.

COMPARATIVE STUDY OF FLUORIDE RELEASE AND RE-UPTAKE OF SEVERAL RESTORATIVE MATERIALS (수종 수복재에 불소 도포제 적용 후 불소유리에 관한 비교연구)

  • Kim, Soo-Yeon;Kim, Jong-Soo;Yoo, Seung-Hoon
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.34 no.3
    • /
    • pp.408-419
    • /
    • 2007
  • In the child, it is very important that he/she will have the ability to suppress aesthetic restorative materials of secondary caries. With the representative preventive material against caries, the importance of fluoride is more emphasized. This study examined the differences in fluoride release and re-uptake among some restorative materials, following a treatment of APF gel and fluoride varnish. The surface roughness was observed under scanning electron microscope. Studying this will provide for the research to find effective restorative materials and fluoride type in tooth caries prevention. It is applied from presence at a clinic that restorative materials are resin, flowable resin, compomer and glass ionomer. Fluoride release was measured at 24-hour intervals for 7 days, 3-day intervals from 8th to 38th day using an ion-selective electrode and analyzer. Then, the materials were treated with the fluoride gel and fluoride varnish respectively, fluoride release was measured and specimens were evaluated under scanning electron microscope for 4 weeks. It was concluded that 1. Fluoride was released for 38 days from restorative materials under 1 ppm in case of flowable resin, 1-2 ppm in compomer and 2-8 ppm in glass ionomer, a few of fluoride was released after 45 days 2. Fluoride has more releasing after application of APF gel than fluoride varnish. Fluoride re-uptake was observed under 0.6-0.2 ppm in fluoride varnish and 0.6-2.6 ppm in APF gel after starting the procedure one day(p<0.05). For the remaining 4 weeks, they demonstrated a similar release. 3. Specimens were evaluated under scanning electron microscope. Applied fluoride in the experimental group surface was rougher than the control group that did not receive fluoride application. Fluoride varnish group had a smoother surface than both the APF gel group and the varnish APF gel group that received a fluoride application.

  • PDF

Types of Deteriolation of Storage Rice in Korea and Identification of the Causative Microorganisms (I) (한국(韓國)에 있어서 미곡변질(米穀變質)의 유형(類型)과 그 원인(原因)이되는 균군(菌群)의 동정(同定)에 대(對)하여 (제 I 보)(第 I 報))

  • Cho, Duck-Hiyon;Chun, Jai-Kun;Kim, Young-Bae
    • Applied Biological Chemistry
    • /
    • v.15 no.3
    • /
    • pp.193-198
    • /
    • 1972
  • Twenty seven specimens of deteriolated storage rice were collected all over Korea. Types of deteriolation were classified according to color outlooks, and for 48 grains of each specimen the causative storage microorganisms were isolated and identified. The following results were observed; 1. 27 specimens of deteriolated rice were classified according to color outlooks into 7 types: reddish yellow 1, light reddish yellow 3, light grayish yellow 4, light red 6, dark gray 7, light gray 3, and rice weevil type 3. 2. The most common storage microorganisms group which infected deteriolated Korean rice were Aspergillus glaucus group, especially species of A. amstelodami, A. chevalieri, A. montevidensis, and A. ruber, which were frequently associated with Penicillium, Brevibactereum, and Bacillus. 3. As a specific case sometimes a specimen of deteriolated rice was infected chiefly by one deminant species of microorganism. Five cases were observed: that is, by P. islandicum, P. lanosum, B. lentus, Pseudomonas cohaerans, Brev. lipolyticum. 4. No definite relationship was observed between color outlook types and the deteriolation causing microorganisms. Only the heavily infected rice by Penicillium islandicum expressed discernible reddish yellow color indicative of the infection by this mold. 5. Mycotoxin problem could be noted in one specimen of deteriolated imported rice heavily infected by P. islandicum. Other mycotoxin producing fungi, A. flavus, A. ochraceus, A. fumigatus were also detected, but their growth frequencies were so low that it might not be serious problem.

  • PDF

In vitro study of microleakage of endodontically treated teeth restored with different adhesive systems and fiber-reinforced posts (다양한 접착시스템을 이용하여 섬유 강화형 포스트로 수복한 치아에서의 미세누출에 관한 연구)

  • Park, Joon-Ho;Choi, Yu-Sung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.52 no.2
    • /
    • pp.74-81
    • /
    • 2014
  • Purpose: While studies have examined microleakage in endodontically treated teeth restored with posts, microleakage among post and adhesive systems remains a concern. This study compared the sealing properties of 3 adhesively luted post systems. Materials and methods: Thirty-six endodontically treated permanent maxillary central incisors were divided into 3 groups: Zirconia-glass fiber, Quartz-glass fiber, Polyethylene fiber posts. Post space was prepared and each post was adhesively luted with 3 systems. The specimens were separately immersed in freshly prepared 2% methylene blue solution for 1 week. The cleaned specimens were then embedded in autopolymerizing acrylic resin. The root portion of tooth were horizontally sectioned into three pieces (apical, middle, and coronal portions). An occlusal view of each section was digitally photographed with a stereomicroscope. The methylene blue-infiltrated surface for each specimen was measured. Dye penetration was estimated as the ratio of the methylene blue-infiltrated surface to the total dentin surface. Results: No significant differences were found among post types. The variables of middle section and 3-stage adhesive produced significant differences in microleakage between the following post pairs: zirconia-glass fiber versus quartz-glass fiber, zirconia-glass fiber versus polyethylene fiber, and quartz-glass fiber versus polyethylene fiber (P<.05). There were significant differences between the apical and coronal sections of each post type, and between apical versus middle sections of quarze-glass fiber and polyethylene fiber posts (P<.05). Conclusion: No significant differences were found among post types. The 3-stage adhesive produced significant differences in microleakage between the following post pairs.

ANALYSIS OF ER:YAG LASER IRRADIATION ON CUTTING EFFICACY AND TEMPERATURE CHANGES OF DENTIN (Er:YAG 레이저의 상아질 삭제효과 및 이에 따른 온도변화)

  • Im, Kwang-Ho;Lee, Chang-Seop;Lee, Sang-Ho
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.28 no.1
    • /
    • pp.32-44
    • /
    • 2001
  • The purpose of this study was to investigate the effects of Er : YAG laser on cutting efficacy and temperature changes of dentin. We used the dentin specimens of human premolars and molars which contain the physiologic saline and maintain the pulpal pressure in dentinal tubules. Each specimen was exposed to Er : YAG laser with non-contact handpiece type delivery system under different treatment condition of irradiation energy, pulse repetition rate, and exposure time. Two procedures were conducted by the presence of water flow during lasing. The specimens were grouped by thickness of dentin. We investigated the cavity pattern, volume, and temperature change of dentin specimen to determine the cutting efficacy and temperature rise of Er : YAG laser, and obtained following results. 1. Cutting volume of dentin was increased by increasing the irradiation energy, pulse repetition rate, and exposure time(P<0.05). 2. Margins of abulated cavities were sharp and clean and floors of cavities were conical in shape and showing smooth surfaces. Upper diameter of abulated cavities were increasing as laser parameter of irradiation energy, pulse repetition rate, and exposure time were increased. A few cracks were observed on abulated surfaces under treatment condition of laser parameter with 150mJ, 5Hz, and 5sec. 3. Temperature was increased as laser parameter of irradiation energy, pulse repetition rate, and exposure time were increased, and temperature rise was decreased as dentin thickness was increased(P<0.05). 4. Temperature rise was decreased under water flow compared with no water flow during laser exposure(P<0.05). From these results, we think that the method of using a Er:YAG laser would be effective and safe in cutting dentin for clinical application.

  • PDF