• Title/Summary/Keyword: Type of Installation

Search Result 1,522, Processing Time 0.031 seconds

Development of Speed Controller and its Application to a 680[MW] Rated Steam Turbine

  • Choi, In-Kyu;Woo, Joo-Hee
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.22 no.11
    • /
    • pp.30-35
    • /
    • 2008
  • An analog type turbine control system in a nuclear power plant in Korea was replaced by a digital type control system successfully. The turbine simulator was used to verify and validate the perfection of newly developed digital control system prior to its actual installation. In this paper, the newly developed turbine speed control system, ie. governor will be introduced together with how to simulate entire control loop. After that, we will compare the comparison of simulation result in laboratory with pre startup simulation result. Eventually the performance of actual operation result was testified.

Experimental Study of the End-plate Gap Effect on the Performance of Extended End-plate Type Splice (이음면 이격이 확장형 단부판 이음부 성능에 미치는 영향에 대한 실험적 연구)

  • Kim, Cheol Hwan;Lee, Myung Jae;Kim, Hee Dong;Kim, Sa Bin
    • Journal of Korean Society of Steel Construction
    • /
    • v.28 no.6
    • /
    • pp.427-438
    • /
    • 2016
  • This study is experimental research for the effect of gap at the end plate on the performance of extended end-plate type splice. For this research, simple beam type specimens by using extended end-plate type splice are planned. Main variables are the initial gap between end-plates, the installation of finger shim plate before the installation of high tension bolts, the final gap between end-plates, and the installation of finger shim plate after the installation of high tension bolts. The static loading tests results show that the maximum bending strength of splice is not dependent on the gap, but the vertical displacement, initial stiffness and elastic stiffness are affected by the gap. In addition to that, the possibility of brittle fracture is increased when the torque of high tension bolt is used to control the gap. Thus, careful consideration is needed in this case.

Structural Design and Installation of Tracking-type Floating PV Generation System (추적식 수상 태양광발전 시스템의 설계 및 시공)

  • Kim, Sun-Hee;Lee, Young-Guen;Seo, Su-Hong;Joo, Hyung-Joong;Yoon, Soon-Jong
    • Composites Research
    • /
    • v.27 no.2
    • /
    • pp.59-65
    • /
    • 2014
  • Most of energy are obtained from oil, coal, and natural gas, most likely, fossil fuel which is limited throughout the world. Recently, high crude oil price, climate change, oil depletion, etc. are main reason to get attention to non-fossil energy including renewable energy in the world. In this study, we studied analysis and design of structure system composed of pultruded fiber reinforced polymer composite (PFRP) which has many advantages such as high specific strength and stiffness, high corrosion resistance and chemical resistance. For the design and construction of floating-type structure, PFRP structural members may be the first choice. Design of tracking-type floating PV generation structure was performed by using the results of the finite element analysis. The structure is fabricated and installed on the water surface. Before the installation of the structure, safety related problems associated with installation and operation are investigated using the finite element simulation and it was found that the structure is safe enough to resist externally applied loads.

Development of Multiple Slim Type Damper System and Performance Test (다중 슬림형 감쇠장치의 개발 및 성능 실험)

  • Sung, E.H.;Kim, D.;Park, D.H.;Park, K.S.;Park, J.H.;Cho, H.J.
    • Journal of the Korean Society of Safety
    • /
    • v.29 no.2
    • /
    • pp.31-37
    • /
    • 2014
  • For the vibration control of residential buildings, a multiple type slim damper system is developed and dynamic performance test is performed in this study. In conventional damping systems, larger installation space is required in order to achieve acceptable seismic performance, and as a result, it is difficult to determine efficient damping capacity of the device. The proposed damping device is composed of several small slim type dampers and linkage units. It can control damping capacity easily by changing the number of the small damper. To evaluate the proposed damping device, three slim type dampers (single-type, triple-type and penta-type) are designed and manufactured in real scale. Dynamic loading tests are performed by using the three manufactured dampers. From the tests, it is shown that damping coefficient is proportional to the number of the damper combined. Thus, test results validates the practicality of the proposed slim type dampers. applying nonlinear curve fitting technique, numerical model of the dampers are developed and presented.

Characteristics of Ozonizers Manufactured in Energy & Environment Electromagnetic Lab. of Yeungnam University

  • Song, Hyun-Jig;Kim, Ki-Chai;Park, Won-Zoo;Lee, Kwang-Sik;Lee, Dong-In
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 1999.11a
    • /
    • pp.11-16
    • /
    • 1999
  • Discharge characteristics research for high voltage and large current electric machinery design, the development of ozonizer with high yield and efficiency for environment improvement, generation of plasma & laser and EMI EMC are research fields of Enersy & Environment Electromagnetic Laboratory(EEEL) in the school of electrical & electronic engineering of Yeungnam University. On this paper, we would like to introduce the discharge and ozone generation characteristics of ozonizers designed and manufactured by EEEL. After starting research for fluid gas discharge characteristics early in the 1980's, high voltage nozzle(HVN) type ozonizer, neon lamp(Nelamp) type ozonizer, ozone lamp(Olamp) type ozonizer and multi-discharge type ozonizer(MDO) have been investigated since 1990.

  • PDF

Reducing Effect of Traffic Noise Soundproof Facilities (방음시설의 소음저감효과에 관한 연구)

  • Jeon, Gi-Seong;Park, Young-Ho
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.3 no.1
    • /
    • pp.20-26
    • /
    • 2000
  • In order to propose the design and installation information of vegetation belt, field investigation were carried out in the noise pollution control facilities of highway and the streets of a city for two years(1998~1999), and field tests were performed to analyze the noise attenuation effect of them. The noise pollution control facilities were generally classified into three types (noise barrier and vegetation belt type, mounding and vegetation belt type, vegetation belt type only). Most soundproof facilities were proved the noise reduction effects. But according to width, height, structure, auditory distance and planting forms of them, difference of noise reduction effects were investigated. The soundproof facility was suitable the mounding and vegetation belt type in the consideration of road environment, and the installation standard of vegetation was estimated that the width of vegetation was at least 20m and the length of that was 2 times in the distance from noise source.

  • PDF

Analysis of Quench Characteristics according to increment of turn number of a reactor and shunt resistors of the Matrix-type Superconductor Fault Current Limiter (매트릭스형 초전도 전류제한기의 리액터의 턴수 및 션트저항 증가에 따른 퀜치특성 분석)

  • Lee, Ju-Hyoung;Oh, Geun-Gon;Jung, Su-Bok;Park, Hyoung-Min;Cho, Young-Sun;Jung, Byoung-Ik;Choi, Hyo-Sang
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2008.05a
    • /
    • pp.332-334
    • /
    • 2008
  • The matrix-type superconducting fault current limiter (SFCL) using YBCO thin film consists of the trigger and current-limiting parts. We fabricated the matrix-type SFCL with the integrated current limiting modules. we carried out the experiment of matrix-type SFCL with the integrated current limiting modules connected in series or parallel. We saw current characteristics due to ratio of change the shunt resistance and turns. We confirmed that the difference of critical current between superconducting units was decreased by increment of current flowing into the reactor which applied the magnetic field into the superconducting units..

  • PDF

The Characteristics of High Ozone Concentration.Yield Multi-discharge Type Ozonizer for Water Environment Improvement (수질환경개선용 고농도·고수율 다중방전형 오존발생기의 특성)

  • ;宋炫直
    • The Proceedings of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.13 no.2
    • /
    • pp.203-203
    • /
    • 1999
  • In this paper, high concentration·yield multi-discharge type ozonizer( MDO ) of new discharge type using superposed silent discharge was designed and manufactured. MDO can be consisted with 3 kind of superposed silent discharge type ozonizer( SDO ) in accordance with power supply method that supplying power, which has 180[°] phase difference, to 3 electrodes and double gap. At the moment discharge characteristics and ozone generation characteristics of each SDO were investigated in accordance with quantify of supplied gas, the number of SDO, and the shapes of each SDO. In result ozone generation characteristics of 17185[ppm] and 783[g/kWh] were obtained, and whorl ozone of 17185[ppm] was in contact with dyeing water waste decolonization characteristics was excellent, so it confirmed that MDO could be used as water environment improvement facility.

Dynamic analysis of Microturbine and FuelCell in MicroGrid using EMTP-RV (마이크로터빈과 연료전지의 EMTP-RV 모델링을 통한 마이크로그리드 내 동특성 분석)

  • Seo, Gyu-Seok;Ju, Jae-Hyun
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.10
    • /
    • pp.42-48
    • /
    • 2010
  • The Microsource has to supply high quality Power that has high reliability and high energy efficiency to Load according to operating type of Microgrid. The energy sources of microsource type have various dynamic characteristic and transient response corresponding to classes and application skill. This paper shows dynamic characteristic of Microgrid according to Energy Source of microsource type. This research has been carried out by detailed modelling of Microturbine system and Fuelcell system. All models are realized by EMTP/RV and simulated change of operating type and load increase within Microgrid of DC constant voltage inverter model and Microturbine, Fuelcell based Microsource.

Approximate Design Optimization of Active Type Desk Support Frame for Float-over Installation Using Meta-model (메타모델을 이용한 플로트오버 설치 작업용 능동형 갑판지지프레임의 근사설계최적화)

  • Lee, Dong Jun;Song, Chang Yong;Lee, Kangsu
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.24 no.1
    • /
    • pp.31-43
    • /
    • 2021
  • In this study, approximate design optimization using various meta-models was performed for the structural design of active type deck support frame. The active type deck support frame was newly developed to facilitate both transportation and installation of 20,000 ton class offshore plant topside. Structural analysis was carried out using the finite element method to evaluate the strength performance of the active type deck support frame in its initial design stage. In the structural analysis, the strength performances were evaluated for various design load conditions that were regulated in ship classification organization. The approximate optimum design problem based on meta-model was formulated such that thickness sizing variables of main structure members were determined by achieving the minimum weight of the active type deck support frame subject to the strength performance constraints. The meta-models used in the approximate design optimization were response surface method, Kriging model, and Chebyshev orthogonal polynomials. The results from approximate design optimization were compared to actual non-approximate design optimization. The Chebyshev orthogonal polynomials among the meta-models used in the approximate design optimization represented the most pertinent optimum design results for the structure design of the active type deck support frame.