여과 성능향상을 위한 이단이층 복합여과시스템의 공정선정 연구 (A Study on the Process Selection for Two-stage and Dual Media Filtration System for Improving Filtration Performance)

  • 송시범;조민;남상호;우달식
    • 상하수도학회지
    • /
    • 제21권2호
    • /
    • pp.203-214
    • /
    • 2007
  • This study aimed at researching the process selection for two-stage and dual media filtration system, as a technology substituting the existing sand filter without expanding the site when retrofitting an old filter bed or designing a new one. In order to select the process for optimum complex filtration system, three running conditions have been tested. Test results demonstrated that Run 3 in which the 1st stage was filled with anthracite and coarse sand, and the 2nd stage was filled up with activated carbon and fine sand reduced the head loss and the load of turbidity substances. Also, Run 3 showed better performance in removing TOC, particle counts, THMFP and HAAFP, compared to other two conditions. 99 % of Cryptosporidium was removed. Bisphenol-A was rarely removed from the 1st stage of coarse sand and 2nd stage of fine sand, but 99 % of it was removed from the 2nd stage of activated carbon. In conclusion, when it is required to retrofit an old rapid filter bed or design a new one for the purpose of improving filtration performance, the following two-stage and dual media filtration system is suggested: the 1st stage of filter bed needs to be filled up with coarse sand to remove turbidity as the pretreatment for extending duration of filtering, the top part of 2nd stage needs to be filled up with granular activated caron to remove dissolved organic matters and others as the main process, and finally the bottom part of 2nd stage needs to be filled up with fine sand as the finishing process.

이단이층 복합여과시스템의 소규모 파일롯 플랜트 적용성 평가 (Applicability Evaluation of Two-stages and Dual Media Filtration System by the Small-scale Pilot Plant)

  • 우달식;송시범;황병기
    • 한국산학기술학회논문지
    • /
    • 제10권4호
    • /
    • pp.857-864
    • /
    • 2009
  • 본 연구에서는 겨울철 수온강하, 여름철 우천시 표류수 중의 고탁도 물질 및 봄, 가을철의 조류성장 시기 등을 고려하여 기존의 급속모래여과시스템을 이단 이층 복합여과시스템으로 개량하는 기술을 개발하는 것을 목표로 하였다. 본 기술은 기존 여과지의 개량 또는 신설 여과지 설계시 또 다른 부지의 확장 없이 기존 모래여과지를 대체하는 기술로서 하부집수장치 상부에 모래 + 활성탄 층을 두고 활성탄 층 상부에 일정한 간격의 역세 팽창층을 두고 전 처리의 개념으로 중간집수장치 위에 모래층을 두는 이단 이층 복합여과시스템을 말한다. 본 연구에서는 이단이층 복합여과시스템을 경기도 S 정수장에 소규모 파일롯 플랜트를 설치하였으며, 탁도는 INTU 이하로 안정하게 유지되었고, TOC, THMFP, HAAFP는 약 90%정도 제거되어 S정수장에 비해 약 2배 정도 높았으며, 이는 본 시스템의 하단에 충전된 활성탄층에서의 흡착 및 생물분해 효과에 기인된 것으로 판단된다.