• Title/Summary/Keyword: Two-ray

Search Result 2,951, Processing Time 0.032 seconds

LONG-TERM SOFT X-RAY VARIABILITY OF ACTIVE GALAXY MRK 841

  • Kim, Chul-Hee
    • Journal of The Korean Astronomical Society
    • /
    • v.41 no.2
    • /
    • pp.17-22
    • /
    • 2008
  • We present an analysis of the soft X-ray emission of MRK 841 to investigate its long-term variation. The light variation of MRK 841 for three different energy bands of soft, medium, and hard values were studied. The maximum variability with a factor of 5 for about two years was confirmed at all three different bands. The light curves exhibit a gradual variation of brightness. In addition to a gradual variation, the short- term or micro variation was also confirmed with a factor of about two for all three different bands. The light variation of each band did not exhibit a correlation between them, but the flare event is strongest in the soft band. The hardness ratio for hard and soft bands shows irregular variation but there was no correlation between them. It was confirmed that there is a gradual decrease of the photon index. Results of our analysis are discussed within the framework of the accretion disk phenomenon.

On the application of angular spectrum for synthesizing a 3-D image from a series of 2-D images (다수의 2차원 단층영상으로부터 3차원 영상을 합성하기 위한 Angular 스펙트럼의 적용)

  • 양훈기;이상이;김은수
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.21 no.7
    • /
    • pp.1668-1676
    • /
    • 1996
  • This paper presents the evaluation of an angular spectrum-based method used to calculate scattering pattern of a three-dimensional object modelled as a collection composed of vertical sectional two-dimensional images. This is done via comparing a proposed method with two existing methods, i.e., a Fresnel hologram method and a ray-tracing method, in terms of computatioal complexities and reconstructed results. Maathematical derivations for each methods are reviewed and implementing procedures are described in detail, along with the amount of computaions required from the implementation point of view, rather than from the mathematical point of view. We show simulation results in which the Fresnel holoram method dose not exhibit promising results although it requires the least computation. Moreover, it is also shown that the proposed method, even with much less computational requirement than the ray-tracing method, produces good performances asmuch as the ray-tracing method does.

  • PDF

Cell Based CMFD Formulation for Acceleration of Whole-core Method of Characteristics Calculations

  • Cho, Jin-Young;Joo, Han-Gyu;Kim, Kang-Seog;Zee, Sung-Quun
    • Nuclear Engineering and Technology
    • /
    • v.34 no.3
    • /
    • pp.250-258
    • /
    • 2002
  • This Paper is to apply the well-established coarse mesh finite difference(CMFD) method to the method of characteristics(MOC) transport calculation as an acceleration scheme. The CMFD problem is first formulated at the pin-cell level with the multi-group structure To solve the cell- based multi-group CMFD problem efficiently, a two-group CMFD formulation is also derived from the multi-group CMFD formulation. The performance of the CMFD acceleration is examined for three test problems with different sizes including a realistic quarter core PWR problem. The CMFD formulation provides a significant reduction in the number of ray tracings and thus only about 9 ray tracing iterations are enough for the realistic problem. In computing time, the CMFD accelerated case is about two or three times faster than the coarse-mesh rebalancing(CMR) accelerated case.

A Low-cost Optimization Design for Minimizing Chromatic Aberration by Doublet Prisms

  • Sun, Wen-Shing;Tien, Chuen-Lin;Sun, Ching-Cherng;Lee, Ching-Chun
    • Journal of the Optical Society of Korea
    • /
    • v.16 no.4
    • /
    • pp.336-342
    • /
    • 2012
  • A low-cost optimal double-prism method is proposed by using the developed MATLAB program to correct chromatic aberration. We present an efficient approach to choose a couple of low-cost glasses to obtain a low aberration double prism. The doublet prisms were made of two lead-free glasses. The relative partial dispersion of the two lead-free glasses is identical and their Abbe numbers are different greatly. The proposed design aims to minimize chromatic aberration, such as in apochromats, for paraxial ray tracing. Finally, an optimization design for real ray tracing can be evaluated by the chromatic aberration curve with a minimal area.

Study on Generator Control for a Small X-Ray Tube (X-선 튜브의 고전압 발생장치 제어에 관한 연구)

  • Lee, Soonhyouk;Ji, Yun-Seo;Choi, Sang Gyu;Lee, Rena
    • Progress in Medical Physics
    • /
    • v.25 no.4
    • /
    • pp.248-254
    • /
    • 2014
  • The purpose of this study is to develope a control system for a small X-ray tube generator and investigate control methods for the X-ray generator. The small X-ray tube was developed for electronic brachytherapy, and thus, the new control method should be investigated, if the small X-ray tube is used for the imaging system. The Axxent S700 X-ray tube and the XF060NZZ485 high voltage generator were used to compose a X-ray imaging system and control board was developed by using AT90CAN128 MCU. The two control methods were investigated after tube voltage was set to 50 kV, one was filament current control method and the other was beam current control method. The former was subdivided into two methods according to the filament heating time, the 5 and the 10 seconds respectively. In the filament current method, the beam current did not rise up to the desired value, if the filament current had not been maintained for at least 10 seconds. The onset filament currents to generate beam current were varied from 1,300 to 1,350 mA and over 5 seconds were needed in order to reach the desired tube current value after beam current was generated. However, in the tube current control method, the beam current reached to the desired value without any time delay with the filament current of 1,500 mA. In this study, we found that the beam current control method was appropriate for the use of small X-ray tube developed for brachytherapy in the X-ray imaging system.

Effect of the amount of battery charge on tube voltage in different hand-held dental x-ray systems

  • Kim, Eun-Kyung
    • Imaging Science in Dentistry
    • /
    • v.42 no.1
    • /
    • pp.1-4
    • /
    • 2012
  • Purpose : Hand-held dental x-ray system is a self contained x-ray machine designed to perform intraoral radiography with one or two hands. The issue about its usage as general dental radiography is still in dispute. The aim of the present study was to assess the relationship between the amount of battery charge and the tube voltage in different handheld dental x-ray systems. Materials and Methods : Seven hand-held dental x-ray units were used for the study. Tube voltage was measured with Unfors ThinX RAD (Unfors Instruments AB, Billdal, Sweden) for 3 consecutive exposures at the different amount of battery charge of each unit. The average and the deviation percentage of measured kV from indicated kV of each unit were calculated. Results : Tube voltage of only 1 unit was 70 kV (indicated by manufacturer) and those of the others were 60 kV. Tube voltage deviation percentage from the indicated kV at the fully charged battery was from 2.5% to -5.5% and from -0.8% to -10.0% at the lowest charged battery. Conclusion : Tube voltages of all units decreased as the residual amount of the battery charge decreased. It is suggested that the performance test for hand-held x-ray system should be performed for the minimum residual charged battery as well as the full charged one. Persistent battery charging is suggested to maintain the proper tube voltage of the hand-held portable x-ray system.

Seismic Tomography using Graph Theoretical Ray Tracing

  • Keehm, Young-Seuk;Baag, Chang-Eob;Lee, Jung-Mo
    • International Union of Geodesy and Geophysics Korean Journal of Geophysical Research
    • /
    • v.25 no.1
    • /
    • pp.23-34
    • /
    • 1997
  • Seismic tomography using the graph theoretical method of ray tracing is performed in two synthetic data sets with laterally varying velocity structures. The straight-ray tomography shows so poor results in imaging the laterally varying velocity structure that the ray-traced tomographic techniques should be used. Conventional ray tracing methods have serious drawbacks, i.e. problems of convergence and local minima, when they are applied to seismic tomography. The graph theretical method finds good approximated raypaths in rapidly varying media even in shadow zones, where shooting methods meet with convergence problems. The graph theoretical method ensures the globally minimal traveltime raypath while bending methods often cause local minima problems. Especially, the graph theoretical method is efficient in case that many sources and receivers exist, since it can find the traveltimes and corresponding raypaths to all receivers from a specific source at one time. Moreover, the algorithm of graph theoretical method is easily applicable to the ray tracing in anisotropic media, and even to the three dimensional case. Among the row-active inversion techniques, the conjugate gradient (CG) method is used because of fast convergence and high efficiency. The iterative sequence of the ray tracing by the graph theoretical method and the inversion by the CG method is an efficient and robust algorithm for seismic tomography in laterally varying velocity structures.

  • PDF

Modification of conventional X-ray diffractometer for the measurement of phase distribution in a narrow region

  • Park, Yang-Soon;Han, Sun-Ho;Kim, Jong-Goo;Jee, Kwang-Yong;Kim, Won-Ho
    • Analytical Science and Technology
    • /
    • v.19 no.5
    • /
    • pp.407-414
    • /
    • 2006
  • An X-ray diffractometer for spatially resolved X-ray diffraction measurements was developed to identify phase in the narrow (micron-scaled) region of high burn-up fuels and some nuclear materials. The micro-XRD was composed of an X-ray microbeam alignment system and a sample micro translation system instead of a normal slit and a fixed sample stage in a commercial XRD. The X-ray microbeam alignment system was fabricated with a microbeam concentrator having two Ni deposited mirrors, a vertical positioner, and a tilt table for the generation of a concentrated microbeam. The sample micro translation system was made with a sample holder and a horizontal translator, allowing movement of a specimen at $5{\mu}m$ steps. The angular intensity profile of the microbeam generated through a concentrator was symmetric and not distorted. The size of the microbeam was $4,000{\times}20{\mu}m$ and the spatial resolution of the beam was $47{\mu}m$ at the sample position. When the diffraction peaks were measured for a $UO_2$ pellet specimen by this system, the reproducibility ($2{\Theta}={\pm}0.01^{\circ}$) of the peaks was as good as a conventional X-ray diffractometer. For the cross section of oxidized titanium metal, not only $TiO_2$ in an outer layer but also TiO near an oxide-metal interface was observed.

IMAGING NON-THERMAL X-RAY EMISSION FROM GALAXY CLUSTERS: RESULTS AND IMPLICATIONS

  • HENRIKSEN MARK;HUDSON DANNY
    • Journal of The Korean Astronomical Society
    • /
    • v.37 no.5
    • /
    • pp.299-305
    • /
    • 2004
  • We find evidence of a hard X-ray excess above the thermal emission in two cool clusters (Abell 1750 and IC 1262) and a soft excess in two hot clusters (Abell 754 and Abell 2163). Our modeling shows that the excess components in Abell 1750, IC 1262, and Abell 2163 are best fit by a steep power law indicative of a significant non-thermal component. In the case of Abell 754, the excess emission is thermal, 1 ke V emission. We analyze the dynamical state of each cluster and find evidence of an ongoing or recent merger in all four clusters. In the case of Abell 2163, the detected, steep spectrum, non-thermal X-ray emission is shown to be associated with the weak merger shock seen in the temperature map. However, this shock is not able to produce the flatter spectrum radio halo which we attribute to post-shock turbulence. In Abell 1750 and IC 1262, the shocked gas appears to be spatially correlated with non-thermal emission suggesting cosmic-ray acceleration at the shock front.

Multispectral X-ray imaging to distinguish among dental materials

  • Peter, Ann-Christin;Schnaubelt, Matthias;Gente, Michael
    • Imaging Science in Dentistry
    • /
    • v.47 no.4
    • /
    • pp.247-254
    • /
    • 2017
  • Purpose: Dual-energy X-ray imaging is widely used today in various areas of medicine and in other applications. However, no similar technique exists for dental applications. In this study, we propose a dual-energy technique for dental diagnoses based on voltage-switching. Materials and Methods: The method presented in this study allowed different groups of materials to be classified based on atomic number, thereby enabling two-dimensional images to be colorized. Computer simulations showed the feasibility of this approach. Using a number of different samples with typical biologic and synthetic dental materials, the technique was applied to radiographs acquired with a commercially available dental X-ray unit. Results: This technique provided a novel visual representation of the intraoral environment in three colors, and is of diagnostic value when compared to state-of-the-art grayscale images, since the oral cavity often contains multiple permanent foreign materials. Conclusion: This work developed a technique for two-dimensional dual-energy imaging in the context of dental applications and showed its feasibility with a commercial dental X-ray unit in simulation and experimental studies.