• Title/Summary/Keyword: Two-port Network Analysis

Search Result 54, Processing Time 0.025 seconds

A study of the transfer characteristics of pressure waves using two-port network analysis in exhaust system of engine (양단자 회로망 분석을 이용한 기관배기계의 압력파 전달특성에 관한 연구)

  • 이준서;유병구;차경옥
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.22 no.1
    • /
    • pp.77-84
    • /
    • 1998
  • Based on experimental analysis, the characteristics of pulsating pressure wave propagation is clarified by testing of 4-stroke gasoline engine. The pulsating pressure wave in exhaust system is generated by pulsating gas flow due to working of exhaust valve. The pulsating pressure wave is closely concerned to the loss of engine power according to back pressure and exhaust noise. It is difficult to exactly calculate pulsating pressure wave propagation in exhaust system because of nonlinear effect. Therefore, in the first step for solving these problems, this paper contains experimental model and analysis method which are applied two-port network analysis. Also, it shows coherence function, frequency response function, back pressure, and gradient of temperature in exhaust system.

  • PDF

Fault Analysis, Using Two-Port Network (4 단자망을 이용한 고장해석)

  • Kim, Jo-Yong;Baek, Young-Sik
    • Proceedings of the KIEE Conference
    • /
    • 1993.07a
    • /
    • pp.124-127
    • /
    • 1993
  • This paper presents the new algorithm for fault analysis and the fault analysis package for executing this algorithm. This algorithm obtains requisite term for fault analysis by the two-port network technique. Therefore, the fault calculation time is minimized because ${Y_{BUS}}^{-1}$ calculation time is removed. And, the graphic user environment for fault analysis is implemented in mouse-oriented user interface with window and pull-down menu. Therefore, this package can be a useful tool for fault analysis.

  • PDF

A study on Competitiveness Analysis of Incheon Port Logistics Network (인천항의 물류네트워크 경쟁력 분석에 관한 연구)

  • Kim, Byung-Il;Yoo, Hong-Sung;Suh, Jae-Hwan
    • Journal of Korea Port Economic Association
    • /
    • v.25 no.2
    • /
    • pp.177-200
    • /
    • 2009
  • This study extracted the major attributes of the competitiveness of services provided by port logistics networks from previous research and interviews with experts and, based on the attributes, analyzed the effects of change in the competitiveness of the Incheon Port. According to the results, services provided by port logistics networks were divided into facility conveniences, access conveniences, and decision conveniences. In the results on the integrated value of the competitiveness of logistics network among ports, competitiveness was high in order of Busan Port>Qigndao Port>Tianjin Port>Dalian Port>Incheon Port. Particularly in the results of scenario analysis, with the elevation of one or two factors of logistics network service, the Incheon Port was even inferior to the Dalian Port, which had the lowest competitiveness among the ports compared. In the results of reversed fuzzy analysis, the Incheon Port could maintain equal competitiveness with the Dalian Port by raising the service level of the logistics network by 25% for facility conveniences, by 8% for access conveniences, and by 1% for decision conveniences.

  • PDF

An Analysis on an Action about Port Choice of Shipper using Fuzzy-Neural Network (퍼지-뉴로를 이용한 화주의 항만선택 행동 분석)

  • Jang, Woon-Jae;Keum, Jong-Soo
    • Journal of Navigation and Port Research
    • /
    • v.31 no.8
    • /
    • pp.725-731
    • /
    • 2007
  • This paper aims to analyze an action about a port choice of shipper between two ports. For this propose, this paper analyzed a port choice action for Kwangyang and Busan port using a fuzzy logic and neural network. Also, this paper compared classification performance of fuzzy-neural network to Logit model, and analyzed a port choice action into change Para-meta such as freight volumes and service standard.

An Analysis of Container Port Efficiency in ASEAN

  • Seo, Young-Joon;Ryoo, Dong-Keun;Aye, Myo-Nyein
    • Journal of Navigation and Port Research
    • /
    • v.36 no.7
    • /
    • pp.535-544
    • /
    • 2012
  • In order to improve the overall ASEAN maritime transport network, each port's efficiency is regarded as a crucial factor that should be calculated periodically. This study evaluated the relative efficiency of container port operations of 32 ports belonging to 9 ASEAN nations using Data Envelopment Analysis (DEA). It found that 2 out of 32 ports in 2010 were measured as efficient ports. This study yielded two major findings. Firstly, the ports assessed as inefficient need to benchmark similar ports in size and structure from the ports that are assessed as efficient to improve their efficiency. Secondly, these results could be used to determine potential candidates and country for an international port development co-operation programme with Korea to improve the performance of the entire ASEAN port network by developing the infrastructures of ill-equipped ports.

Analysis of the Changes of Liner Service Networks by Using SNA: Focused on Incheon Port (사회연결망 분석을 활용한 컨테이너 정기선 항로 변화 분석: 인천항을 중심으로)

  • Park, Ki-Hyun;Lin, Mei-Shun;Ahn, Seung-Bum
    • Journal of Korea Port Economic Association
    • /
    • v.32 no.1
    • /
    • pp.97-122
    • /
    • 2016
  • Incheon port attained two million TEU of container throughput between 2013 and 2014 as a third port in domestic container throughput. It opened a new port in Song-do, Incheon in June 2015 to prepare for the continuing increase in container throughput.Therefore, it has provided the platform for being the major container port domestically and internationally. As the role of the new port increases, the role and direction of the Incheon port liner service network attracts attention. This study analyzes the centrality of the Incheon port liner service network by using SNA (Social Network Analysis), which was introduced in the maritime economics area recently, focusing on the Incheon port liner service network. We recognize the degree centrality, closeness centrality, and betweenness centrality of each port and its effect on the Incheon port liner service network. The study showed that for Incheon port, the centrality of the Busan port in Korea, and the Hong Kong port, is high outside the country. This helps us determine that the hub of the Incheon port is neither Shanghai nor Singapore, which ranks first and second, respectively, on container throughput. It is also helps us to know that eastern China's ports have not played a role of the hub of the Incheon port until now because of the relatively low centrality of eastern China's ports.

Short-Circuit Calculation Using Tow-Port Network (4단자망을 아용한 고장계산에 관한 연구)

  • 김주용;이재용;백영식
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.43 no.4
    • /
    • pp.533-542
    • /
    • 1994
  • This paper presents the new algorithm for fault analysis and this algorithm obtains requisite term for fault analysis by the two-port network technique. Therefore, the fault calculation time is composed of only few fundamental arithmetic calculation. The graphic user environment for fault analysis is implemented in mouse-oriented user interface with window and pull-down menu. The result of the algorithm proved to be identical with the sample system in Ref.[8]. this package can be a useful tool for fault analysis.

Analysis of Voltage Unbalance in the Electric Railway Depot Using Two-port Network Model (4단자 회로망 모델을 이용한 전기철도 차량기지의 전압불평형 해석)

  • Chang, Sang-Hoon;Oh, Kwang-Hae;Kim, Jung-Hoon
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.50 no.5
    • /
    • pp.248-254
    • /
    • 2001
  • The traction power demand highly varies with time and train positions and the traction load is a large-capacity current at single phase converted from 3-phase power system. Subsequently, each phase current converted from 3-phase power system cannot be maintained in balance any longer and thus the traction load can bring about imbalance in three-phase voltage. Therefore, the exact assessment of voltage unbalance must be carried out preferentially as well as load forecast at stages of designing and planning for electric railway system. The evaluation of unbalance voltage in areas, such as electric railway depots should be a prerequisite with more accuracy. The conventional researches on voltage unbalance have dealt with connection schemes of the transformers used in ac AT-fed electric railroads system and induced formulas to briefly evaluate voltage unbalance in the system(3). These formulas are still being used widely due to their easy applicabilities on voltage unbalance evaluation. Meanwhile, they don't take into account detailed characteristics of ac AT-fed electric railroads system, being founded on some assumptions. Accordingly. accuracy still remains in question. This paper proposes a new method to more effectively estimate voltage unbalance index. In this method, numerous diverted circuits in electric railway depots are categorized in three components and each component is defined as a two-port network model. The equivalent circuit for the entire power supply system is also described into a two-port network model by making parallel and/or series connections of these components. Efficiency and accuracy in voltage unbalance calculation as well can be promoted by simplifying the circuits into two-port network models.

  • PDF

Two-Port Vector Network Analysis System with a Vector Signal Channel (벡터 전압 수신기를 이용한 2-포트 산란 계수 분석 시스템)

  • Lee, Dong-Joon
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.24 no.5
    • /
    • pp.541-548
    • /
    • 2013
  • This paper presents a vector network analysis system for 2-port scattering parameters of microwave devices using some basic microwave instruments/devices such as signal generators, vector voltmeter, directional couplers and frequency mixers. The analytical model and implementation method for scattering parameter measurements - which can replace the vector network analyzers - are presented. The performance of the implemented system is evaluated through 1- and 2-port scattering parameter measurements, respectively. The vector volt signals which determine the scattering parameters are detected in two distinct methods depending on the frequency band of interests; a direct-detection method with a single signal generator and vector voltmeter for relatively low band and a heterodyne method to frequency down-mix associated with an additional signal source as well as frequency mixers for high band are used, respectively. Using these two methods, scattering parameters of UHF and X bands are evaluated and their performances are verified through a comercial vector network analyzer.

Impedance Analysis of High Integrated Sensor Array Using Impedance Relation Matrix (임피던스 관계 행렬을 이용한 고집적 센서 어레이의 임피던스 분석에 관한 연구)

  • Lee, Hak-Sung
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.48 no.3
    • /
    • pp.1-5
    • /
    • 2011
  • In order to analyze the impedance properties of high integrated impedance network with multiple terminals, this paper introduces the concept of impedance relation matrix(IRM). The linear relation between the terminal voltages and currents is represented in the form of IRM and this matrix can be utilized to calculate the impedance between any two terminals. Furthermore, IRM representation for 2-port impedance network can be also defined. The whole impedance network is divided into the several 2-port sub-networks and each sub-network is analyzed in a form of the IRM representation. An illustrated example is given to show that the proposed method is simple and effective to analyze the impedance of a sensor array which has a very large number of impedance elements.