• Title/Summary/Keyword: Two-phase three-leg inverter

Search Result 23, Processing Time 0.031 seconds

A Novel PWM Method for Three-Leg Two-Phase Inverter Fed Two-Phase Induction Motor (2상 유도전동기 구동 2상 인버터를 위한 새로운 PWM제어방식 II - 3-레그 타입의 경우 -)

  • Jang Do-Hyun
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.10 no.4
    • /
    • pp.339-346
    • /
    • 2005
  • It is complex to realize the reference voltage vector by the space vector PWM method in three-leg two-phase inverter In this paper a new PWM technique for three-leg two-phase inverter fed two-phase induction motor is poroposed assuming that three-leg two-phase inverter is equivalent circuit for 'four-leg two-phase inverter with the connected two windings'. From assumption, six sectors are decreased to four sectors, and simple sinusoidal PWM method instead of SVPWM is applied to three-leg two-phase inverter. Also, the switching pattern to determine the switching periods at each sector is proposed. Practical verification of theoretical predictions is presented to confirm the capabilities of the new techniques.

Compensation of Effects of DC-Link Ripple Voltages on Output Voltage of Two-Leg Three-Phase PWM Inverters (2-레그 3상 PWM 인버터의 출력전압에서 직류링크 리플전압의 영향 보상)

  • Kim Young-Sin;Lee Dong-Choon;Seok Jul-Ki
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.55 no.1
    • /
    • pp.47-53
    • /
    • 2006
  • In this paper, a simple scheme compensating for the effect of dc-link ripple voltages on output voltage of two-leg and three-phase PWM inverters is proposed, where single-phase half-bridge PWM convertor and two-leg inverter are used. The voltage at neutral point of the dc-link is controlled so that the upper-half of do-link voltage is equal to the lower-half voltage in average concept. However, the effect of the do-link ripple voltage results in the inverter output voltage and current distortion. This effect can be eliminated by introducing a compensation voltage in switching time calculation. Also, the inverter dead time should be compensated for sinusoidal output waveform. The proposed scheme has been verified by experimental results which were obtained from the V/F constant operation of the induction motor fed by two-leg inverter.

DC-Link Voltage Balance Control in Three-phase Four-wire Active Power Filters

  • Wang, Yu;Guan, Yuanpeng;Xie, Yunxiang;Liu, Xiang
    • Journal of Power Electronics
    • /
    • v.16 no.5
    • /
    • pp.1928-1938
    • /
    • 2016
  • The three-phase four-wire shunt active power filter (APF) is an effective method to solve the harmonic problem in three-phase four-wire power systems. In addition, it has two possible topologies, a four-leg inverter and a three-leg inverter with a split-capacitor. There are some studies investigating DC-link voltage control in three-phase four-wire APFs. However, when compared to the four-leg inverter topology, maintaining the balance between the DC-link upper and lower capacitor voltages becomes a unique problem in the three-leg inverter with a split-capacitor topology, and previous studies seldom pay attention to this fact. In this paper, the influence of the balance between the two DC-link voltages on the compensation performance, and the influence of the voltage balance controller on the compensation performance, are analyzed. To achieve the balance between the two DC-link capacitor voltages, and to avoid the adverse effect the voltage balance controller has on the APF compensation performance, a new DC-link voltage balance control strategy for the three-phase four-wire split-capacitor APF is proposed. Representative simulation and experimental results are presented to verify the analysis and the proposed DC-link voltage balance control strategy.

Performance Analysis of a Five-leg Inverter for the Train Propulsion System (철도차량 추진시스템을 위한 FLI(Five-leg Inverter)의 성능 분석)

  • Lim, Young-Seol;Shin, Duck-Ho;Lee, June-Seok;Lee, Kyo-Beum
    • Journal of the Korean Society for Railway
    • /
    • v.20 no.1
    • /
    • pp.43-54
    • /
    • 2017
  • This paper analyzes the performance of two three-leg inverters and a five-leg inverter and proposes the optimal operation conditions in applying the five-leg inverter for the train propulsion system. The five-leg inverter offers a saving of two switches compared with the standard two three-leg inverters and it is possible to control two three-phase motors independently by using a control board. All of these features lead to a potential reduction in capital cost and miniaturization of system. In this paper, first, the analysis of the existing motor control method and PWM method for two-traction motor drive of urban railway is implemented. Next, the operation principle and performance of five-leg inverter is introduced. Through the analysis, when it applies the same motor control method and the same PWM method for three-leg inverter and five-leg inverter, the characteristic of motor's speed and torque is compared.

The Power Analysis and Its Control of Two-phase Orthogonal Power Supply for the Continuous Casting

  • Ma, Fujun;Luo, An;Xiong, Qiaopo
    • Journal of Electrical Engineering and Technology
    • /
    • v.10 no.3
    • /
    • pp.971-982
    • /
    • 2015
  • In order to improve the quality of the billet continuous casting, a two-phase orthogonal power supply (TPOPS) for electromagnetic stirrer is researched, which is composed of three-phase PWM rectifier and three-leg inverter. According to the power analysis of system, the ripple of dc-link voltage is analyzed and its analytical expression is derived. In order to improve the performance of electromagnetic stirring, an integrated control method with feedforward control is proposed for PWM rectifier to suppress the fluctuations of dc-link voltage and provide a stable dc source for inverter. According to the simplified equivalent model, a composite current control method is proposed for inverter. This proposed method can combine the merits of feedforward control with feedback control to effectively improve the dynamic output performance of TPOPS. Finally, a 300kVA prototype of TPOPS is developed, and the results have verified the analysis and control method.

Simulation of Phase Unbalance and Power Factor Correction System (비상용발전기의 상불평형 및 역율보상기 시뮬레이션)

  • Shin, B.C.;Song, E.H.;Jeong, C.Y.;Kan, Y.;Cho, J.G.;Rim, G.H.
    • Proceedings of the KIEE Conference
    • /
    • 1997.11a
    • /
    • pp.419-421
    • /
    • 1997
  • Three-phase system has many problems because of the unbalance load. So we propose two control algorithms using active power filter to dissolve these problems. One is three-leg inverter topology in which ac neutral line is connected directly to the midpoint of two series dc capacitors. The other is four-leg inverter topology in which ac neutral line is provided through a fourth leg. The three-phase unbalance is considered by connecting the load to one-phase. It is show that the proposed control algorithms give good performances.

  • PDF

A Simplified Modulation Strategy for Three-leg Voltage Source Inverter Fed Unsymmetrical Two-winding Induction Motor

  • Sinthusonthishat, Saliltip;Chuladaycha, Nontawat
    • Journal of Electrical Engineering and Technology
    • /
    • v.8 no.6
    • /
    • pp.1337-1344
    • /
    • 2013
  • This paper presents a simplified modulation strategy for the three-leg VSI fed two-winding induction motor. The strategy provides independent unbalanced voltage control for the main and auxiliary windings. This make the motor can be reversed rotation through the range of motor speed operation without limitation of voltage boost of the auxiliary winding. To study the advantages of the proposed drive, the experimental results such as voltage stresses, hysteresis band of the currents in locus, and also acoustic noise levels of the three-leg VSI are compared with those of the conventional two-leg topology. The results obviously show that the proposed technique achieves superior performance compared with the traditional scheme in case of dramatic increase of DC bus utilization, effective reduction of harmonic voltages content, and also significant enhancement of motor efficiency.

Implementation of Space Vector Two-Arm Modulation for Independent Motor Control Drive Fed by a Five-Leg Inverter

  • Talib, Md Hairul Nizam;Ibrahim, Zulkifilie;Rahim, Nasrudin Abd.;Abu Hasim, Ahmad Shukri
    • Journal of Power Electronics
    • /
    • v.14 no.1
    • /
    • pp.115-124
    • /
    • 2014
  • This paper presents the implementation of two-arm modulation (TAM) technique for the independent control of a two-induction motor drive fed by a five-leg inverter (FLI). A carrier-based space vector pulse width modulation technique for TAM is proposed to generate switching signals for FLI. Two independent three-phase space vector modulators are utilized to control two motors. The motor drive system applies two separate indirect field-oriented control methods. The stationary voltage outputs from the vector control are synthesized in the three-phase space vector modulator to generate switching signals for FLI. The performance of the independent control of the motors and the voltage utilization factor are likewise analyzed. Simulation and experimental results verify the effectiveness of the proposed method for the independent control of the two-motor drive system. The proposed technique is successfully validated by dSPACE DS1103 experimental work.

A Study on the Three Phase Inverter using Auxiliary Switches (보조 스위치를 이용한 3상 ZCS 인버터에 관한 연구)

  • Bae, Jin-Yong;Kim, Yong;Baek, Soo-Hyun;Choi, Geun-Soo
    • Proceedings of the KIEE Conference
    • /
    • 2004.04a
    • /
    • pp.155-158
    • /
    • 2004
  • This paper proposes a soft-transition control strategy for a three phase ZCS(Zero Current Switching) inverter circuit. Each phase leg of inverter circuit consists of an LC resonant tank, two main switches, and two auxiliary switches. This paper presents design consideration via a study example of a three phase prototype inverter for motor drives. A simple device tester with zero current switching capability is proposed to select eligible auxiliary switches. The principle of operation, feature and design consideration is illustrated and verified through the experiment with a 2.2kW 5kHz IGBT based experimental circuit.

  • PDF

A Novel Three-Phase Line-Interactive UPS System having AC Line Reactor and Parallel-Series Active Filters (AC 라인 리액터와 병렬 및 직렬 능동필터를 가지는 새로운 3상 라인 인터렉티브 무정전전원장치 시스템)

  • Ji Jun-Keun
    • Proceedings of the KAIS Fall Conference
    • /
    • 2004.06a
    • /
    • pp.193-197
    • /
    • 2004
  • The four-leg Voltage Source Converter(VSC) can use the DC link voltage effectively by the 3-D SVPWM method. Hence the DC battery voltage can be reduced by $15\%$ in comparison to that of the conventional line-interactive UPS system. In this paper a novel line interactive Uninterruptible Power Supply(UPS) using the two four-leg VSCs is proposed. One VSC is in parallel with the ac link reactor of the power source side, and the other is in series with the load. The parallel four-leg voltage source inverter controls the three-phase line voltage independently in order to control the line reactor current indirectly. It eliminates the neutral line current and the active ripple power of the source side using the pqr theory so that unity power factor and the sinusoidal source current can be achieved even though both the source and the load voltages have zero sequence components. The series four-leg voltage source inverter compensates the line voltage and allows it to be balanced and harmonic-free. Both of the parallel and series four-leg voltage source inverters always act as independently controllable voltage sources, so that the three-phase output voltage shows a seamless transition to the backup mode. The feasibility of the proposed UPS system has been investigated and verified through computer simulations results.

  • PDF