• 제목/요약/키워드: Two-phase half bridge

검색결과 37건 처리시간 0.031초

단일 전류 센서를 이용한 2상 하프브릿지 인버터의 상전류 측정 방법 (A Novel Current Measurement Method for Two-Phase Half-bridge Inverter using Single Current Sensor)

  • 조영훈;목형수;장도현;김상훈
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2007년도 하계학술대회 논문집
    • /
    • pp.193-195
    • /
    • 2007
  • This paper proposed a novel current measurement method for two-phase half-bridge inverter using single current sensor. The proposed method measures DC link input current and a phase current simultaneously and reconstructs each phase currents by simple calculation according to voltage vector. The commutation modes of two-phase half-bridge inverter is analized. The current sampling and reconstructing method is also presented. The proposed method is verified through simulation and experimental results on two-phase induction motor drive system.

  • PDF

저 가격형 UPS를 구성하기 위한 단상 부스트 컨버터의 고 역률 제어 (Power Factor Correction of Single-phase Boost Converter for Low-cost Type UPS Configuration)

  • 박종찬;손진근
    • 전기학회논문지P
    • /
    • 제62권3호
    • /
    • pp.145-150
    • /
    • 2013
  • A novel AC to DC PWM converters with unity input power factor are proposed to overcome the above shortcoming. The main function of these converters is to shape the input line current to force it exactly in phase with the input AC voltage. Therefore, the input power factor can be improved to near unity and the input current harmonics can be eliminated. In this paper, half-bridge converter with two active switches and two diodes are utilized for low-cost type UPS configuration. By having only two semiconductors in the current path at any time, losses can be reduced over the conventional boost topology. Also, this converter provides controllable dc-link voltage, high power factor, and low cost type converter by simple power circuits. Simulation results show that the proposed half-bridge converter/inverter control technique can be applied to single-phase low-cost type UPS systems successfully.

인터리브드 풀 브릿지 컨버터와 단상 하프 브릿지 인버터를 이용한 1.5kW급 PCS 설계 (Design of 1.5kW PCS Using Interleaved Full-Bridge Converter and Single Phase Half-Bridge Inverter)

  • 나광수;나종국;이희준;신수철;원충연
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2013년도 전력전자학술대회 논문집
    • /
    • pp.403-404
    • /
    • 2013
  • In this paper, a PCS which consists of high boost interleaved full-bridge converter and single phase half-bridge inverter is proposed. Proposed PCS is using two full bridge converter modules. PCS consists of parallel input / serial output. It can reduce turn ratio of high frequency transformer. In this paper, PCS which is using 1.5[kW] interleaved full-bridge converter and single phase half bridge inverter is designed and verified stability of system through experiment.

  • PDF

고승압 듀얼 컨버터와 단상 하프 브릿지 인버터를 적용한 새로운 PCS (New PCS Applied High Boost Ratio Dual Converter and Single Phase Half Bridge Inverter)

  • 이희준;신수철;현승욱;정용채;원충연
    • 전력전자학회논문지
    • /
    • 제18권6호
    • /
    • pp.515-522
    • /
    • 2013
  • In this paper, a new PCS is proposed which is consisted of high boost dual converter and single phase half-bridge inverter. The proposed PCS is configured in parallel input / serial output, using two interleaved voltage doubler converter. Converter of the proposed PCS is distribute input current by configuring parallel input and reduced turn ratio of transformer by configuring serial output. Also, compositions of the inverter are composed of serial output capacitor of converter and half-bridge inverter. The dual converter and single phase half-bridge inverter is designed and characteristic of the new PCS is analysed. The system of the 1.5[kW] PCS is verified through an experimental about operation and stability.

냉장고의 선형압축기 구동을 위한 단상 하프브리지 인버터 시스템에서 직류단 불평형 보상에 관한 연구 (DC Voltage Balancing Control of Half-Bridge PWM Inverter for Liniear Compressor of Refrigerator)

  • 김호진;김형진;김동윤;김장목
    • 전력전자학회논문지
    • /
    • 제22권3호
    • /
    • pp.256-262
    • /
    • 2017
  • This paper presents the control algorithm of a single-phase AC/DC/AC PWM converter for the linear compressor of a refrigerator. The AC/DC/AC converter consists of a full-bridge PWM converter for the control of the input power factor and a half-bridge PWM inverter for the control of the single-phase linear compressor. At the DC-link of this topology, two capacitors are connected in series. These DC-link voltages must be balanced for safe operation. Thus, a new control method of DC voltage balancing for the half-bridge PWM inverter is proposed. The balancing algorithm uses the Integral-Proportional controller and inserts the DC-offset current at the Proportional-Resonant current controller of the inverter to solve the DC-link unbalanced voltages between the two capacitors. The proposed algorithm can be easily implemented without much computation and additional hardware circuit. The usefulness of the proposed algorithm is verified through several experiments.

Compensation of Current Offset Error in Half-Bridge PWM Inverter for Linear Compressor

  • Kim, Dong-Youn;Im, Won-Sang;Hwang, Seon-Hwan;Kim, Jang-Mok
    • Journal of Power Electronics
    • /
    • 제15권6호
    • /
    • pp.1593-1600
    • /
    • 2015
  • This paper proposes a novel compensation algorithm of current offset error for single-phase linear compressor in home appliances. In a half-bridge inverter, current offset error may cause unbalanced DC-link voltage when the DC-link is comprised of two serially connected capacitors. To compensate the current measurement error, the synchronous reference frame transformation is used for detecting the measurement error. When an offset error occurs in the output current of the half-bridge inverter, the d-axis current has a ripple with frequency equal to the fundamental frequency. With the use of a proportional-resonant controller, the ripple component can be removed, and offset error can be compensated. The proposed compensation method can easily be implemented without much computation and additional hardware circuit. The validity of the proposed algorithm is verified through experimental results.

A Fault Tolerant Structure and Control Strategy for Electromagnetic Stirring Supplies

  • Li, Yan;Luo, An;Xiang, Xinxing;Chen, Yandong;He, Zhixing;Zhou, Fayun;Chen, Zhiyong
    • Journal of Power Electronics
    • /
    • 제17권5호
    • /
    • pp.1256-1267
    • /
    • 2017
  • A fault tolerant structure and its corresponding control strategy for electromagnetic stirring power supplies are proposed in this paper. The topology structure of the electromagnetic stirring power supply contains two-stages. The fore-stage is the PWM rectifier. The back-stage is the fault tolerant inverter, which is a two-phase three-bridge orthogonal inverter circuit while operating normally. When the power switch devices in the inverter are faulty, the structure of the inverter is reconfigured. The two-phase half bridge inverter circuit is constructed with the remaining power switch devices and DC-link capacitors to keep the system operating after cutting the faulty power switch devices from the system. The corresponding control strategy is proposed to let the system work under both normal and fault conditions. The reliability of the system is improved and the requirement of the electromagnetic stirring process is met. Finally, simulation and experimental results verify the feasibility of the proposed fault tolerant structure and corresponding control strategy.

2-레그 3상 PWM 인버터의 출력전압에서 직류링크 리플전압의 영향 보상 (Compensation of Effects of DC-Link Ripple Voltages on Output Voltage of Two-Leg Three-Phase PWM Inverters)

  • 김영신;이동춘;석줄기
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제55권1호
    • /
    • pp.47-53
    • /
    • 2006
  • In this paper, a simple scheme compensating for the effect of dc-link ripple voltages on output voltage of two-leg and three-phase PWM inverters is proposed, where single-phase half-bridge PWM convertor and two-leg inverter are used. The voltage at neutral point of the dc-link is controlled so that the upper-half of do-link voltage is equal to the lower-half voltage in average concept. However, the effect of the do-link ripple voltage results in the inverter output voltage and current distortion. This effect can be eliminated by introducing a compensation voltage in switching time calculation. Also, the inverter dead time should be compensated for sinusoidal output waveform. The proposed scheme has been verified by experimental results which were obtained from the V/F constant operation of the induction motor fed by two-leg inverter.

전압형 인버터가 연결된 새로운 방식의 SRM 컨버터 (New SRM converter connected to the voltage source inverter)

  • 장도현
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2004년도 전력전자학술대회 논문집(1)
    • /
    • pp.260-264
    • /
    • 2004
  • In this paper the novel converter topology for the switched reluctance motor drives is proposed, which is composed of the minimum switch per phase and is connected to the single-phase voltage inverter for ac voltage source. The proposed converter topology is divided into two types according to the voltage source inverter of half bridge type and full bridge type. Proposed converters of two types are proposed, analyzed and compared with each other. The SRM using proposed converter maintain the hi인 efficiency though the power switches are reduced.

  • PDF

단상 태양광 발전용 고효율 벅부스트 하프브리지 인버터 (A High-efficiency Buck-boost Half-bridge Inverter for Single-phase Photovoltaic Generation)

  • 류형민
    • 전기전자학회논문지
    • /
    • 제27권4호
    • /
    • pp.450-455
    • /
    • 2023
  • 태양광 패널의 큰 기생 커패시턴스에 기인하는 과도한 누설 전류를 피하기 위한 단상 태양광 인버터 중에 부스트 컨버터와 하프브리지 인버터를 종속적으로 결합하는 방식은 가장 단순하면서 누설 전류가 가장 작다. 하지만 직류단 전압이 높아 스위칭 소자의 정격 전압이 높고 스위칭 손실이 크다. 본 논문은 부스트 컨버터를 제거하는 대신에 하프브리지 인버터의 출력 측에 2개의 양방향 스위치를 추가함으로써 벅부스트 인버터로 동작할 수 있는 새로운 회로 토폴로지를 제안한다. 고전압 직류단을 거치는 두 단계의 전력 변환을 한 단계로 줄인 덕분에 전력 손실을 절감할 수 있으며 비용 및 누설 전류는 증가하지 않는다. 제안된 회로 토폴로지의 타당성은 컴퓨터 시뮬레이션 및 전력 손실 계산을 통해 검증한다.