• 제목/요약/키워드: Two-dimensional temperature

검색결과 1,047건 처리시간 0.028초

A Two-dimensional Steady State Simulation Study on the Radio Frequency Inductively Coupled Argon Plasma

  • Lee, Ho-Jun;Kim, Dong-Hyun;Park, Chung-Hoo
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • 제2C권5호
    • /
    • pp.246-252
    • /
    • 2002
  • Two-dimensional steady state simulations of planar type radio frequency inductively coupled plasma (RFICP) have been performed. The characteristics of RFICP were investigated in terms of power transfer efficiency, equivalent circuit analysis, spatial distribution of plasma density and electron temperature. Plasma density and electron temperature were determined from the equations of ambipolar diffusion and energy conservation. Joule heating, ionization, excitation and elastic collision loss were included as the source terms of the electron energy equation. The electromagnetic field was calculated from the vector potential formulation of ampere's law. The peak electron temperature decreases from about 4eV to 2eV as pressure increases from 5 mTorr to 100 mTorr. The peak density increases with increasing pressure. Electron temperatures at the center of the chamber are almost independent of input power and electron densities linearly increase with power level. The results agree well with theoretical analysis and experimental results. A single turn, edge feeding antenna configuration shows better density uniformity than a four-turn antenna system at relatively low pressure conditions. The thickness of the dielectric window should be minimized to reduce power loss. The equivalent resistance of the system increases with both power and pressure, which reflects the improvement of power transfer efficiency.

드릴링 공정의 열거동 해석과 관측기를 이용한 온도 추정법 (Analysis of Thermal Behavior and Temperature Estimation by using an Observer in Drilling Processes)

  • 김태훈;정성종
    • 대한기계학회논문집A
    • /
    • 제27권9호
    • /
    • pp.1499-1507
    • /
    • 2003
  • Physical importance of cutting temperatures has long been recognized. Cutting temperatures have strongly influenced both the tool life and the metallurgical state of machined surfaces. Temperatures in drilling processes are particularly important, because chips remain in contact with the tool for a relatively long time in a hole. Tool temperatures tend to be higher in drilling processes than in other in machining processes. This paper concerns with modeling of thermal behaviors in drilling processes as well as estimation of the cutting temperature distribution based on remote temperature measurements. One- and two-dimensional estimation problems are proposed to analyze drilling temperatures. The proposed thermal models are compared with solutions of finite element methods. Observer algorithms are developed to solve inverse heat conduction problems. In order to apply the estimation of cutting temperatures, approximation methods are proposed by using the solution of the finite element method. In two-dimensional analysis, a moving heat source according to feedrate of the drilling process is regarded as a fixed heat source with respect to the drilling location. Simulation results confirm the application of the proposed methods.

전자유체의 차원에 따른 임계온도의 변화 (The Dependence of the Critical Temperature on the Dimensions of the Electron Motion)

  • 박성훈;김미연;최동식;김원수
    • 대한화학회지
    • /
    • 제40권6호
    • /
    • pp.401-408
    • /
    • 1996
  • 일반적으로 고온 초전도체들은 2차원적인 구조를 가지고 있으며, 2차원적인 구조가 초전도 물성과 어떠한 관계를 갖는가를 이해하는 것은 매우 중요하다. 본 논문에서는 초전도체 속의 전자기체를 기체분자운동론을 사용하여 각 차원에서의 상태 방정식을 유도하였으며, 그 기체가 액화될 때의 온도, 임계온도를 구하였다. 그 결과 전자의 자유도를 제한시킴에 따라 임계온도가 상승함을 알 수 있었다. 이것은 2차원적인 구조물질에 1차원적인 전자유통 경로가 있을 경우 여러가지의 임계온도를 가질 수 있음을 의미한다.

  • PDF

Inverse Brightness Temperature Estimation for Microwave Scanning Radiometer

  • Park, Hyuk;Katkovnik, Vladimir;Kang, Gum-Sil;Kim, Sung-Hyun;Choi, Jun-Ho;Choi, Se-Hwan;Jiang, Jing-Shan;Kim, Yong-Hoon
    • 대한원격탐사학회지
    • /
    • 제19권1호
    • /
    • pp.53-59
    • /
    • 2003
  • The passive microwave remote sensing has progressed considerably in recent years Important earth surface parameters are detected and monitored by airborne and space born radiometers. However the spatial resolution of real aperture measurements is constrained by the antenna aperture size available on orbiting platforms and on the ground. The inverse problem technique is researched in order to improve the spatial resolution of microwave scanning radiometer. We solve a two-dimensional (surface) temperature-imaging problem with a major intention to develop high-resolution methods. In this paper, the scenario for estimation of both radiometer point spread function (PSF) and target configuration is explained. The PSF of the radiometer is assumed to be unknown and estimated from the observations. The configuration and brightness temperature of targets are also estimated. To do this, we deal with the parametric modeling of observation scenario. The performance of developed algorithms is illustrated on two-dimensional experimental data obtained by the water vapor radiometer.

Two-dimensional Numerical Simulation of a Pulsed Heat Source High Temperature Inert Gas Plasma MHD Electrical Power Generator

  • Matsumoto, Masaharu;Murakami, Tomoyuki;Okuno, Yoshihiro
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2008년 영문 학술대회
    • /
    • pp.589-596
    • /
    • 2008
  • Performance of a pulsed heat source high temperature inert gas plasma MHD electrical power generator, which can be one of the candidates of space-based laser-to-electrical power converter, is examined by a time dependent two dimensional numerical simulation. In the present MHD generator, the inert gas is assumed to be ideally heated to about $10^4K$ pulsed-likely within short time(${\sim}1{\mu}s$) in a stagnant energy input volume, and the energy of high temperature inert gas is converted to the electricity with the medium of pure inert gas plasma without seeding. The numerical simulation results show that an enthalpy extraction ratio(=electrical output energy/pulsed heat energy) of several tens of % can be achieved, which is the same level as the conventional seeded non-equilibrium plasma MHD generator. Although there still exist many phenomena to be clarified and many problems to be overcome in order to realize the system, the pulsed heat source high temperature inert gas MHD generator is surely worth examining in more detail.

  • PDF

코르크 삭마를 고려한 비행체 1D 온도해석 도구 개발 (A Development of One-dimensional Thermal Analysis Tool for Flight Vehicle with Cork Insulation)

  • 정태빈
    • 한국군사과학기술학회지
    • /
    • 제21권4호
    • /
    • pp.464-470
    • /
    • 2018
  • A development of one-dimensional thermal analysis tool is performed to estimate the thickness of cork insulation for flight vehicle. In the calculation of cork temperature, the cork density model, heat of ablation and pyrolysis gas enthalpy model were applied. The calculation for the two-layer model of cork and metal was performed by the tool and compared with the experimental data. The results for the two aerodynamic heating conditions were 17 % and -12 % different from the experimental data, respectively. The effect of mechanical ablation not included in the calculation can be expected as the cause of the difference. The temperature-density curve of cork which adjusted by experimental data was also presented.

3차원 측정 로보트 셀 개발 (Development of 3-dimensional measuring robot cell)

  • 박강;조경래;신현오;김문상
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1991년도 한국자동제어학술회의논문집(국내학술편); KOEX, Seoul; 22-24 Oct. 1991
    • /
    • pp.1139-1143
    • /
    • 1991
  • Using industrial robots and sensors, we developed an inline car body inspection system which proposes high flexibility and sufficient accuracy. Car Body Inspection(CBI) cell consists of two industrial robots, two corresponding carriages, camera vision system, a process computer with multi-tasking ability and several LDS's. As industrial robots guarantee sufficient repeatabilities, the CBI cell adopts the concept of relative measurement instead of that of absolute measurement. By comparing the actual measured data with reference data, the dimensional errors of the corresponding points can be calculated. The length of the robot arms changes according to ambient temperature and it affects the measuring accuracy. To compensate this error, a robot arm calibration process was realized. By measuring a reference jig, the differential changes of the robot arms due to temperature fluctuation can be calculated and compensated.

  • PDF

가열로 내 소재의 2 차원 총괄열흡수율 추정에 관한 역해석 (An Inverse Analysis on the Estimation of Two-dimensional Total Heat Exchange Factor on the Billet in the Reheating Furnace)

  • 곽동성;강덕홍;김기홍;김우승
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2003년도 추계학술대회
    • /
    • pp.175-180
    • /
    • 2003
  • An inverse problem to determine two-dimensional total heat exchange factor is studied for the prediction of the billet temperature in the reheating furnace. Temperature measurements by the experiment are used in the inverse analysis. This inverse analysis employs the conjugate gradient method. The total heat exchange factors for 12-zones of the cross-section of the billet are estimated. The estimated temperatures at measurement locations are in good agreements with the measured temperatures.

  • PDF

가열로 내 소재의 2 차원 총괄열흡수율 추정에 관한 역해석 (An Inverse Analysis on the Estimation of Two-dimensional Overall Heat Absorptance on the Slab in the Reheating Furnace)

  • 강덕홍;곽동성;김우승
    • 대한기계학회논문집B
    • /
    • 제29권11호
    • /
    • pp.1257-1264
    • /
    • 2005
  • An inverse problem to determine two-dimensional total heat exchange factor is studied for the prediction of the slab temperature in the reheating furnace. Temperature measurements by the experiment are used in the inverse analysis. This inverse analysis employs the conjugate gradient method. The overall heat absorptances for 12-zones of the cross-section of the slab are estimated. The estimated temperatures at measurement locations are in good agreements with the measured temperatures.

의료용 적외선 영상장치의 구현 (Development of Medical Infrared Imaging System)

  • 이수열;우응제;조민형;송형빈
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1993년도 춘계학술대회
    • /
    • pp.17-20
    • /
    • 1993
  • With proper designs of infrared optic system and two dimensional scanning mechanism, a medical infrared imaging system has been developed. The infrared imaging system can be used for two dimensional imaging of surface temperature of human body by measuring the amount of infrared lights radiating from it. It hag been experimentally proven that the degree of temperature measurement accuracy of the developed system is under $0.1^{\circ}C$ with spatial resolution of 1 mrad, image matrix size of $256{\times}240$, and imaging time of 4 seconds.

  • PDF