• Title/Summary/Keyword: Two-dimensional

Search Result 12,536, Processing Time 0.047 seconds

Measurement of facial soft tissues thickness using 3D computed tomographic images (3차원 전산화단층찰영 영상을 이용한 얼굴 연조직 두께 계측)

  • Jeong Ho-Gul;Kim Kee-Deog;Han Seung-Ho;Shin Dong-Won;Hu Kyung-Seok;Lee Jae-Bum;Park Hyok;Park Chang-Seo
    • Imaging Science in Dentistry
    • /
    • v.36 no.1
    • /
    • pp.49-54
    • /
    • 2006
  • Purpose : To evaluate accuracy and reliability of program to measure facial soft tissue thickness using 3D computed tomographic images by comparing with direct measurement. Materials and Methods : One cadaver was scanned with a Helical CT with 3 mm slice thickness and 3 mm/sec table speed. The acquired data was reconstructed with 1.5 mm reconstruction interval and the images were transferred to a personal computer. The facial soft tissue thickness were measured using a program developed newly in 3D image. For direct measurement, the cadaver was cut with a bone cutter and then a ruler was placed above the cut side. The procedure was followed by taking pictures of the facial soft tissues with a high-resolution digital camera. Then the measurements were done in the photographic images and repeated for ten times. A repeated measure analysis of variance was adopted to compare and analyze the measurements resulting from the two different methods. Comparison according to the areas was analyzed by Mann-Whitney test. Results : There were no statistically significant differences between the direct measurements and those using the 3D images (p>0.05). There were statistical differences in the measurements on 17 points but all the points except 2 points showed a mean difference of 0.5 mm or less. Conclusion : The developed software program to measure the facial soft tissue thickness using 3D images was so accurate that it allows to measure facial soft tissues thickness more easily in forensic science and anthropology.

  • PDF

System Development and IC Implementation of High-quality and High-performance Image Downscaler Using 2-D Phase-correction Digital Filters (2차원 위상 교정 디지털 필터를 이용한 고성능/고화질의 영상 축소기 시스템 개발 및 IC 구현)

  • 강봉순;이영호;이봉근
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.2 no.3
    • /
    • pp.93-101
    • /
    • 2001
  • In this paper, we propose an image downscaler used in multimedia video applications, such as DTV, TV-PIP, PC-video, camcorder, videophone and so on. The proposed image downscaler provides a scaled image of high-quality and high-performance. This paper will explain the scaling theory using two-dimensional digital filters. It is the method that removes an aliasing noise and decreases the hardware complexity, compared with Pixel-drop and Upsamling. Also, this paper will prove it improves scaling precisians and decreases the loss of data, compared with the Scaler32, the Bt829 of Brooktree, and the SAA7114H of Philips. The proposed downscaler consists of the following four blocks: line memory, vertical scaler, horizontal scaler, and FIFO memory. In order to reduce the hardware complexity, the using digital filters are implemented by the multiplexer-adder type scheme and their all the coefficients can be simply implemented by using shifters and adders. It also decreases the loss of high frequency data because it provides the wider BW of 6MHz as adding the compensation filter. The proposed downscaler is modeled by using the Verilog-HDL and the model is verified by using the Cadence simulator. After the verification is done, the model is synthesized into gates by using the Synopsys. The synthesized downscaler is Placed and routed by the Mentor with the IDEC-C632 0.65${\mu}{\textrm}{m}$ library for further IC implementation. The IC master is fixed in size by 4,500${\mu}{\textrm}{m}$$\times$4,500${\mu}{\textrm}{m}$. The active layout size of the proposed downscaler is 2,528${\mu}{\textrm}{m}$$\times$3,237${\mu}{\textrm}{m}$.

  • PDF

Image analytical observation on the growth and development of Clonorchis sinensis in rats (흰쥐 감염 간흡충의 성장 및 발육에 대한 형태계측학적 관찰)

  • Jin KIM
    • Parasites, Hosts and Diseases
    • /
    • v.33 no.4
    • /
    • pp.281-288
    • /
    • 1995
  • For the two-dimensional observation on the growth and development of CLonorchis sinensis, an image analysis system (IBAS 2000, Kontron, Germany) was used in this study. On 3, 6, 9, 12, 15, 21, 30 and 90 days of infection, 474 worms were collected from rats infected with 50 metacercariae each. The overall recovery rate was 31.6%. The worms grew rapidly in their length and width up to 30 days of infection and then, did slowly to 90 days of infection. However, the growth pattern of body area was not similar to that of body length and width, because the body area increased continuously even after 30 days of infection. With the image analysis system, the sizes of irregular-shaped genital organs were measured easily, which showed sigmoidal growth patterns . The growth rate of genital organs increased rapidly. until 21 days of infection when the uterus was filled with numerous eggs, and then gradually slowed down to 90 days. There was no difference in growth pattern between the anterior and posterior testis. The seminal receptacle , however, showed an abrupt increase in size between 15 to 21 days of infection when it was filled with condensed semen. Therefore, the growth pattern of seminal receptacle might be used as another criteria to estimate the extent of sexual maturation of C. sinensis. From this study, it is suggested that image analysis system is very useful to reveal the growth and development pattern of C. sinensis, especially of their internal organs.

  • PDF

Enhanced Diffusion in a Polymer Electrolyte Membrane Fuel Cell Using Pulsating Flow (연료전지 내에서의 왕복유동을 이용한 확산증대 효과에 대한 연구)

  • Hwang, Yong-Sheen;Choi, Jong-Won;Lee, Dae-Young;Kim, Min-Soo;Lee, Dea-Heung;Kim, Seo-Young;Cho, Sung-Ho;Cha, Suk-Won
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.34 no.2
    • /
    • pp.185-189
    • /
    • 2010
  • This study considered the feasibility of controlling the air concentration by oscillating flow in fuel cell channels. The fuel cell stack performance is largely influenced by the air concentration. If the air concentration is lower than 2.5 times the stoichiometric of the inlet air, the fuel cell stack performance seriously deteriorates because of air starvation. In this respect, optimizing the air concentration is crucially important to maximizing the fuel cell stack performance. In this work, the effects of oscillating actuation were studied to control the concentration. Studies have shown that there are two non-dimensional key parameters related to the frequency and oscillating amplitude. This paper presents how those parameters affect the performance of the stack.

Adenyl Cyclase Activity in Cold-acclimatized Animals (한냉적응이 Adenyl Cyclase Activity에 미치는 영향)

  • Kang, Bok-Soon;Lee, Sang-Ho;Kang, Doo-Hee
    • The Korean Journal of Physiology
    • /
    • v.8 no.2
    • /
    • pp.67-74
    • /
    • 1974
  • The object of this research is aimed to determine the activity of adenyl cyclase in both skeletal muscle sarcolemma and fat cell ghost of epididymal adipose tissue isolated from rats exposed to cold for various length of time in an attempt to evaluate whether the tissue sensitivity to catecholamine is increased when rats are exposed to cold for long periods of time Methods: a)Animals: Albino rats ranging in weight from 150 to 200 gm were used throughout this study. For experimental purposes, the rats are divided into two groups: experimental animals were place4 in a cold room at $4^{\circ}C$, controls being kept at $25^{\circ}C$. At the end of 2, 4, 6, 12, and 16 weeks. exposure to cold the rats were used to measure the adenyl cyclase activity. b) Isolation of plasma membrane from skeletal muscle and adipose tissue: The Plasma membrane of skeletal muscle from hind limbs of rats are prepared by the method employed by Rosenthal et at. and fat cell ghost of epididymal adipose tissue of rats by the method employed by Rodbell. c) Adenyl cyclase assay: Adenyl cyclase activity were measured by the method employed by Marinetti et al. Briefly, plasma membrane was incubated with $3^H-ATP$, various amount of noradrenaline and other incubation mixture at $37^{\circ}C$ for 20 minutes. After stopping the enzyme reaction by immersion in boiling water, carrier 3',5'-AMP was added to the system as a marker and $100\;{\mu}1$ aliquots of incubation mixture were pipetted on $20{\time}20$ Whatman No. 3 MM filter paper for one dimensional chromatography. The cyclic AMP spots were cut off and placed in counting vials containing 10ml of Bray's scintillation cocktail. Radioactivity was determined with a Packard Tri-Carb liquid scintillation counter. The enzyme activity is expressed as nanomoles of cyclic AMP produced per mg of membrane per hour. Result: 1. Average adenyl cyclase activity in the plasma membrane of skeletal muscle before and after noradrenaline administration was significantly higher in the cold-exposed rats as compared to the control. Continuous exposure to cold Produced an increased adenyl cyclase activity before and after noradrenaline administration. Adenyl cyclase activity reached peak levels at the 6 weeks exposure to told and level of adenyl cyclase activity remained high. Noradrenaline administration to the incubation medium induced a significant increase in adenyl cyclase activity and the degree of stimulation were proportional to the hormonal concentration But the rate of inclement in adenyl cyclase activity by noradreasline was the same in both groups. 2. Adenyl cyclase activity in fat cell ghost between cold exposed and control rats showed no significant differences before and after noradreualine administration. In summary, it can be concluded that cold adaptation give rise an increased activity of adenyl cyclase in plasma membrane of skeletal muscle in rats.

  • PDF

Effect of a Frontal Impermeable Layer on the Excess Slurry Pressure during the Shield Tunnelling (전방 차수층이 쉴드터널 초과 이수압에 미치는 영향)

  • Lee, Yong-Jun;Lee, Sang-Duk
    • Proceedings of the KSR Conference
    • /
    • 2011.10a
    • /
    • pp.1199-1213
    • /
    • 2011
  • Slurry type shield would be very effective for the tunnelling in a sandy ground, but low slurry pressure could cause a tunnel face failure or a ground settlement in front of the tunnel face. Thus, the stability of tunnel face could be maintained by applying an excess slurry pressure that is larger than the active earth pressure. However, the slurry pressure should increase properly because an excessively high slurry pressure could cause the slurry flow out or the passive failure of the frontal ground. It is possible to apply the high slurry pressure without passive failure if a horizontal impermeable layer is located in the ground in front of the tunnel face, but its location, size, and effects are not clearly known yet. In this research, two-dimensional model tests were carried out in order to find out the effect of a horizontal impermeable layer for the slurry shield tunnelling in a saturated sandy ground. As results, larger slurry pressure could be applied to increase the stability of the tunnel face when the impermeable layer was located in the ground above the crown in front of the tunnel face. The most effective length of the impermeable grouting layer was 1.0~1.5D, and the location was 1.0D above the crown level. The safety factor could be suggested as the ratio of the maximum slurry pressure to the active earth pressure at the tunnel face. It could also be suggested that the slurry pressure in the magnitude of 3.5~4.0 times larger than the active earth pressure at the initial tunnel face could be applied if the impermeable layer was constructed at the optimal location.

  • PDF

Myocardial atrophy in children with mitochondrial disease and Duchenne muscular dystrophy

  • Lee, Tae Ho;Eun, Lucy Youngmin;Choi, Jae Young;Kwon, Hye Eun;Lee, Young-Mock;Kim, Heung Dong;Kang, Seong-Woong
    • Clinical and Experimental Pediatrics
    • /
    • v.57 no.5
    • /
    • pp.232-239
    • /
    • 2014
  • Purpose: Mitochondrial disease (MD) and Duchenne muscular dystrophy (DMD) are often associated with cardiomyopathy, but the myocardial variability has not been isolated to a specific characteristic. We evaluated the left ventricular (LV) mass by echocardiography to identify the general distribution and functional changes of the myocardium in patients with MD or DMD. Methods: We retrospectively evaluated the echocardiographic data of 90 children with MD and 42 with DMD. Using two-dimensional echocardiography, including time-motion (M) mode and Doppler measurements, we estimated the LV mass, ratio of early to late mitral filling velocities (E/A), ratio of early mitral filling velocity to early diastolic mitral annular velocity (E/Ea), stroke volume, and cardiac output. A "z score" was generated using the lambda-mu-sigma method to standardize the LV mass with respect to body size. Results: The LV mass-for-height z scores were significantly below normal in children with MD ($-1.02{\pm}1.52$, P<0.001) or DMD ($-0.82{\pm}1.61$, P =0.002), as were the LV mass-for-lean body-mass z scores. The body mass index (BMI)-for-age z scores were far below normal and were directly proportional to the LV mass-for-height z scores in both patients with MD (R =0.377, P<0.001) and those with DMD (R =0.330, P=0.033). The LV mass-for-height z score correlated positively with the stroke volume index (R =0.462, P<0.001) and cardiac index (R =0.358, P<0.001). Conclusion: LV myocardial atrophy is present in patients with MD and those with DMD and may be closely associated with low BMI. The insufficient LV mass for body size might indicate deterioration of systolic function in these patients.

A Study of Mobile Content Generation System using 2-Dimensional bar code in Smart Device Environment (스마트 기기 환경에서 2차원 바코드를 활용한 모바일 콘텐츠 생성 시스템 연구)

  • Jin, Byung-Wook;Lee, Keun-Wang
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.4
    • /
    • pp.2349-2354
    • /
    • 2014
  • While the number of smart phone subscribers excessing 30 million people, Korea is leaping into the 'smart powerhouse' from IT powerhouse. The popularizat+ion of smart devices so called 'PC in the hand', brought surely change to people's life style, and also it had led to a revolutionary change to and also to business and government. In several corporations of each countries, a variety of smart devices smart devices such as smart phone, tablet PC and E-books have been developing. Nowadays, the usage of the smart phone is not only the simple function calling. It has become a culture of the terminal type in the hand anywhere at any time, which makes can communicate with the others in anywhere and anytime. However, some of the subscribers who visit the website for PC version with the mobile devices screen, can feel kind of discomfort while surfing the net on a smartphone devices because the install of the existing video and flash files and the screen size for computer is not available for mobile devices. Therefore, in this paper, we studied on effective mobile contents generation program using QR code that is two dimensions bar code under the smart device environment. Also, unlike previous QR code generator that decorate standardized design, we realize an original QR code generation system from user perspective.

Identification and Clinical Implications of Novel MYO15A Mutations in a Non-consanguineous Korean Family by Targeted Exome Sequencing

  • Chang, Mun Young;Kim, Ah Reum;Kim, Nayoung K.D.;Lee, Chung;Lee, Kyoung Yeul;Jeon, Woo-Sung;Koo, Ja-Won;Oh, Seung Ha;Park, Woong-Yang;Kim, Dongsup;Choi, Byung Yoon
    • Molecules and Cells
    • /
    • v.38 no.9
    • /
    • pp.781-788
    • /
    • 2015
  • Mutations of MYO15A are generally known to cause severe to profound hearing loss throughout all frequencies. Here, we found two novel MYO15A mutations, c.3871C>T (p.L1291F) and c.5835T>G (p.Y1945X) in an affected individual carrying congenital profound sensorineural hearing loss (SNHL) through targeted resequencing of 134 known deafness genes. The variant, p.L1291F and p.Y1945X, resided in the myosin motor and IQ2 domains, respectively. The p.L1291F variant was predicted to affect the structure of the actin-binding site from three-dimensional protein modeling, thereby interfering with the correct interaction between actin and myosin. From the literature analysis, mutations in the N-terminal domain were more frequently associated with residual hearing at low frequencies than mutations in the other regions of this gene. Therefore we suggest a hypothetical genotype-phenotype correlation whereby MYO15A mutations that affect domains other than the N-terminal domain, lead to profound SNHL throughout all frequencies and mutations that affect the N-terminal domain, result in residual hearing at low frequencies. This genotype-phenotype correlation suggests that preservation of residual hearing during auditory rehabilitation like cochlear implantation should be intended for those who carry mutations in the N-terminal domain and that individuals with mutations elsewhere in MYO15A require early cochlear implantation to timely initiate speech development.

An Assessment of Fish Habitat of Natural Fishway by Hydraulic Model Experiments and Numerical Analysis (수리모형실험과 수치해석을 통한 자연형어도의 어류서식처 평가)

  • Lee, Sung-Hyun;Oh, Kuk-Ryul;Cheong, Tae-Sung;Jeong, Sang-Man
    • Journal of Korea Water Resources Association
    • /
    • v.45 no.3
    • /
    • pp.317-329
    • /
    • 2012
  • It is increasing to make an efforts on preventing natural river environment and preserving natural river ecosystem as development is unavoidable. In the case of inconsistent river flow caused by reservoir development, fishway is an alternative to secure fish diversity and preserve existing river ecosystem but existing fishway was established without full study for their functions. In this study, hydraulic characteristics of natural fishway established on Beakje weir's right side were analyzed. The results show that the fishway has reasonable depth and velocity condition which inhabit condition is enough for a dominant species. For assessing the optimal design of fishway, the Weighted Usable Area (WUA) was calculated by using two dimensional numerical model under the ordinary flow condition. The comparison results for various pool widths in the fishway show that the designed width has maximum WUA for adult Zacco platypus but WUA is maximized with 1m wider pool width than designed width for spawning.