• 제목/요약/키워드: Two-Phase Natural Convection

검색결과 33건 처리시간 0.022초

Experiments on Sedimentation of Particles in a Water Pool with Gas Inflow

  • Kim, Eunho;Jung, Woo Hyun;Park, Jin Ho;Park, Hyun Sun;Moriyama, Kiyofumi
    • Nuclear Engineering and Technology
    • /
    • 제48권2호
    • /
    • pp.457-469
    • /
    • 2016
  • During the late phase of severe accidents of light water reactors, a porous debris bed is expected to develop on the bottom of the flooded reactor cavity after breakup of the melt in water. The geometrical configuration, i.e., internal and external characteristics, of the debris bed is significant for the adequate assessment of the coolability of the relocated corium. The internal structure of a debris bed was investigated experimentally using the DAVINCI (Debris bed research Apparatus for Validation of the bubble-Induced Natural Convection effect Issue) test facility. Particle sedimentation under the influence of a two-phase natural convection flow due to the decay heat in the debris bed was simulated by dropping various sizes of particles into a water vessel with air bubble injection from the bottom. Settled particles were collected and sieved to obtain the particle mass, size distribution in the radial and axial positions, and the bed porosity and permeability. The experimental results showed that the center part of the particle bed tended to have larger particles than the peripheral area. For the axial distribution, the lower layer had a higher fraction of larger particles. As the sedimentation progressed, the size distribution in the upper layers can shift to larger sizes because of the higher vapor generation rate and stronger flow intensity.

상변화 물질을 이용한 이동전화기의 냉각에 관한 연구 (A Study of Cooling of Mobile Phone Using PCM Module)

  • 이상진;정수진;김우승
    • 대한기계학회논문집B
    • /
    • 제29권11호
    • /
    • pp.1173-1181
    • /
    • 2005
  • The cooling effect of a mobile phone using PCM(Phase Change Material) module has been numerically investigated. A transient three-dimensional numerical analysis of heat and fluid flow with natural convection is performed in this study. Governing conservation equations for mass, momentum and energy are solved by an implicit finite volume method. An enthalpy-porosity technique has been used for modeling of the melting process. Two different ways of placing the PCM module are considered. One is to place a PCM module between the substrate and battery pack, and the other is to place a PCM module between MCM(multichip module) and battery pack. Three different types of PCMs are used to predict the performance of PCM. The results show that passive cooling with PCM can reduce the temperature rise and the effect of natural convection in PCM module considered in this study is negligible.

CUPID 코드의 유체 물성치 변화를 고려한 자연대류 해석 (NATURAL CIRCULATION ANALYSIS CONSIDERING VARIABLE FLUID PROPERTIES WITH THE CUPID CODE)

  • 이승준;박익규;윤한영;김정우
    • 한국전산유체공학회지
    • /
    • 제20권4호
    • /
    • pp.14-20
    • /
    • 2015
  • Without electirc power to cool down the hot reactor core, passive systems utilizing natural circulation are becoming a big specialty of recent neculear systems after the severe accident in Fukusima. When we consider the natural circulation in a pool, thermal mixing phenomena may start from single phase circulation and can continue to two phase condition. Since the CUPID code, which has been developed for two-phase flow analysis, can deal with the phase transition phenomena, the CUPID would be pertinent to natural convection problems in single- and two-phase conditions. Thus, the CUPID should be validated against single- and two-phase natural circulation phenomena. For the first step of the validation process, this study is focused on the validation of single-phase natural circulation. Moreover, the CUPID code solves the fluid properties by the relationship to pressure and temperature from the steam table considering non-condensable gas effects, so that the effects from variable properties are included. Simple square thermal cavity problems are tested for laminar and turbulent conditions against numerical and experimental data. Throughout the investigation, it is found that the variable properties can affect the flow field in laminar condition, but the effect becomes weak in turbulence condition, and the CUPID code implementing steam table is capable of analyzing single phase natural circualtion phenomena.

Experimental investigation of two-phase natural circulation loop as passive containment cooling system

  • Lim, Sun Taek;Kim, Koung Moon;Kim, Haeseong;Jerng, Dong-Wook;Ahn, Ho Seon
    • Nuclear Engineering and Technology
    • /
    • 제53권12호
    • /
    • pp.3918-3929
    • /
    • 2021
  • In this study, we experimentally investigate of a two-phase natural circulation loop that functions as a passive containment cooling system (PCCS). The experimental apparatus comprises two loops: a hot loop, for simulating containment under severe accidents, and a natural circulation loop, for simulating the PCCS. The experiment is conducted by controlling the pressure and inlet temperature of the hot loop in the range of 0.59-0.69 MPa (abs) and 119.6-158.8 ℃, respectively. The heat balance of the hot loop is established and compared with a natural circulation loop to assess the thermal reliability of the experimental apparatus, and an additional system is installed to measure the vapor mass flow rate. Furthermore, the thermal-hydraulic characteristics are considered in terms of a temperature, mass flow rate, heat transfer coefficient (HTC), etc. The flow rate of the natural circulation loop is induced primarily by flashing, and a distortion is observed in the local HTC because of the fully develop as well as subcooled boiling. As a result, we present the amount of heat capacity that the PCCS can passively remove according to the experimental conditions and compared the heat transfer performance using Chen's and Dittus-Boelter correlation.

Thermal-hydraulic study of air-cooled passive decay heat removal system for APR+ under extended station blackout

  • Kim, Do Yun;NO, Hee Cheon;Yoon, Ho Joon;Lim, Sang Gyu
    • Nuclear Engineering and Technology
    • /
    • 제51권1호
    • /
    • pp.60-72
    • /
    • 2019
  • The air-cooled passive decay heat removal system (APDHR) was proposed to provide the ultimate heat sink for non-LOCA accidents. The APDHR is a modified one of Passive Auxiliary Feed-water system (PAFS) installed in APR+. The PAFS has a heat exchanger in the Passive Condensate Cooling Tank (PCCT) and can remove decay heat for 8 h. After that, the heat transfer rate through the PAFS drastically decreases because the heat transfer condition changes from water to air. The APDHR with a vertical heat exchanger in PCCT will be able to remove the decay heat by air if it has sufficient natural convection in PCCT. We conducted the thermal-hydraulic simulation by the MARS code to investigate the behavior of the APR + selected as a reference plant for the simulation. The simulation contains two phases based on water depletion: the early phase and the late phase. In the early phase, the volume of water in PCCT was determined to avoid the water depletion in three days after shutdown. In the late phase, when the number of the HXs is greater than 4089 per PCCT, the MARS simulation confirmed the long-term cooling by air is possible under extended Station Blackout (SBO).

Calculation of Temperature Rise in Gas Insulated Busbar by Coupled Magneto-Thermal-Fluid Analysis

  • Kim, Hong-Kyu;Oh, Yeon-Ho;Lee, Se-Hee
    • Journal of Electrical Engineering and Technology
    • /
    • 제4권4호
    • /
    • pp.510-514
    • /
    • 2009
  • This paper presents the coupled analysis method to calculate the temperature rise in a gas insulated busbar (GIB). Harmonic eddy current analysis is carried out and the power losses are calculated in the conductor and enclosure tank. Two methods are presented to analyze the temperature distribution in the conductor and tank. One is to solve the thermal conduction problem with the equivalent natural convection coefficient and is applied to a single phase GIB. The other is to employ the computational fluid dynamics (CFD) tool which directly solves the thermal-fluid equations and is applied to a three-phase GIB. The accuracy of both methods is verified by the comparison of the measured and calculated temperature in a single phase and three-phase GIB.

상변화 물질의 용융과정에 있어서 좌표변환을 이용한 온도분포의 해석적 연구 (The finite difference analysis on temperature distribution by coordinate transformation during melting process of phase-change Material)

  • 김준근;임장순
    • 태양에너지
    • /
    • 제5권2호
    • /
    • pp.77-83
    • /
    • 1985
  • An analysis is performed to investigate the influence of the buoyancy force and the thickness variation of melting layer in the containment that is filled with phase-change Material surrounding a cylindrical heating tube during melting process. The phase-change material is assumed to be initially solid at its phase-change temperature and the remaining solid at any given time is still at the phase-change temperature and neglecting the effect of heat transfer occuring within the solid. At the start of melting process, the thickness of melting layer is assumed to be a stefan-problem and after the starting process, the change of temperature and velocity is calculated using a two dimensional finite difference method. The governing equations for velocity and temperature are solved by a finite difference method which used SIMPLE (Semi Implicit Method Pressure linked Equations) algorithm. Results are presented for a wide range of Granshof number and in accordance with the time increment and it is founded that two dimensional fluid flow occurred by natural convection decreases the velocity of melting process at the bottom of container. The larger the radius of heating tube, the higher heat transfer is occurred in the melting layer.

  • PDF

국소교란이 있는 난류박리 재부착유동의 이산와류 수치해석 (Discrete Vortex Simulation of Turbulent Separated and Reattaching Flow With Local Perturbation)

  • 정용만;성형진
    • 대한기계학회논문집
    • /
    • 제18권2호
    • /
    • pp.479-491
    • /
    • 1994
  • Discrete vortex method was applied for simulating an active control of turbulent leading- edge separation bubble. The leading-edge separation zone was perturbed by a time-dependent sinusoidal perturbation of different frequencies and levels. In order to describe the local sinusoidal perturbation at the separation point, a source pulsation vortex technique was proposed. The present two-dimensional vortex simulations were qualitatively compared with the experimental results for a blunt circular cylinder, where perturbation was introduced along the square-cut leading edge of the cylinder $(Kiya et al.^{(6,7)}).$ It was found that the reattachment length attained a minimum point at low levels of perturbation and two minima at a moderate higher perturbation frequency. The effects of local perturbation on the evolution of leading-edge separation bubble were scrutinized by comparing the perturbed flow with the natural flow. These comparisons were made for the distributions of mean velocity and its velocity fluctuations, intermittency and wall velocity. The motions of instantaneous reattachment in the space-time domain were demonstrated, which were also compared with the experimental findings. In order to investigate the reduction mehanism of reattachment length in the separation bubble, various cross-correlations for velocity and pressure and the relevant convection velocities were evaluated. It was observed that the convection velocity was closely associated with its corresponding pulsationg frequency.

정사각형 단면을 갖는 용기에서 단면의 크기 변화가 융해 열전달에 미치는 영향 (Effect of the Height Change on the Melting Heat Transfer in a Rectangular Enclosure)

  • 한진호;노승탁
    • 설비공학논문집
    • /
    • 제2권3호
    • /
    • pp.208-217
    • /
    • 1990
  • A rectangular test section is devised by assuming two dimensional melting of a solid phase change material heated from two sides which are maintained at constant temperature and allowing a free expansion due to density difference between solid and liquid. The timewise melting shape is recorded photographically by the shadow graph method for several experimental conditions. The analysis shows that the melting process consists of four regimes. At first, the pure conduction heat transfer is dominant, and as time goes by natural convection grows and plays a role greatly. Experiments are carried out varying not only the wall temperature but height of the wall. Each effect of them on the melting process is obtained in the form of combination of dimensionless parameters, $Ste^{0.8}\;FoRa^{0.2}$. An algebraic correlation is suggested, which predicts the melted fraction well.

  • PDF

열음향(Thermoacoustic) 레이저의 음향파 특성 분석 (The Analysis of Acoustic Waves generated by a TA(ThermoAcoustic) Laser Pair)

  • 오승진;;이윤준;신상웅;임상훈;천원기
    • 한국태양에너지학회 논문집
    • /
    • 제31권6호
    • /
    • pp.1-7
    • /
    • 2011
  • Sound waves and acoustic energy generated by two identical TA (ThermoAcoustic) lasers were analyzed and studied. One end of the ceramic stack was heated by a thin NiCr wire wound around that end. The other end of the stack was cooled by natural convection of atmospheric air. The wavelength of the sound waves generated by a single TA laser was four times the tube length and the amplitude of the waves increased with the heating rate. SPL (SoundPressure Level) meters and microphones were employed to measure and study the sound waves at different distances from the glass tube opening and at the focusing point of the TA laser pair for different laser position arrangements. The sound waves of the two TA lasers at the focusing point were found to be almost 180 degrees out of phase when the openings of the two lasers were very close to each other and the angle between the laser axes was small. When the two TA lasers were placed far apart, the sound wave amplitudes and the phase difference between the two laser outputs varied periodically with time. The frequencies of the sound waves changed when the openings of the two TA lasers were in close vicinity and the angle between the laser axes exceeded a certain value. In this case, the glass tube opening was no longer a pressure anti-node and the wavelength of the fundamental mode was not equal to four times the tube length.