• Title/Summary/Keyword: Two- Phase flow

Search Result 1,654, Processing Time 0.031 seconds

EXTENSION OF CFD CODES APPLICATION TO TWO-PHASE FLOW SAFETY PROBLEMS

  • Bestion, Dominique
    • Nuclear Engineering and Technology
    • /
    • v.42 no.4
    • /
    • pp.365-376
    • /
    • 2010
  • This paper summarizes the results of a Writing Group on the Extension of CFD codes to two-phase flow safety problems, which was created by the Group for Analysis and Management of Accidents of the Nuclear Energy Agency' Committee on the Safety of Nuclear Installations (NEA-CSNI). Two-phase CFD used for safety investigations may predict small scale flow processes, which are not seen by system thermalhydraulic codes. However, the two-phase CFD models are not as mature as those in the single phase CFD and potential users need some guidance for proper application. In this paper, a classification of various modelling approaches is proposed. Then, a general multi-step methodology for using two-phase-CFD is explained, including a preliminary identification of flow processes, a model selection, and a verification and validation process. A list of 26 nuclear reactor safety issues that could benefit from investigations at the CFD scale is identified. Then, a few issues are analyzed in more detail, and a preliminary state-of-the-art is proposed and the remaining gaps in the existing approaches are identified. Finally, guidelines for users are proposed.

An experimental study on two-phase flow resistances and interfacial drag in packed porous beds

  • Li, Liangxing;Wang, Kailin;Zhang, Shuangbao;Lei, Xianliang
    • Nuclear Engineering and Technology
    • /
    • v.50 no.6
    • /
    • pp.842-848
    • /
    • 2018
  • Motivated by reducing the uncertainties in quantification of debris bed coolability, this paper reports an experimental study on two-phase flow resistances and interfacial drag in packed porous beds. The experiments are performed on the DEBECO-LT (DEbris BEd COolability-Low Temperature) test facility which is constructed to investigate the adiabatic single and two phase flow in porous beds. The pressure drops are measured when air-water two phase flow passes through the porous beds packed with different size particles, and the effects of interfacial drag are studied especially. The results show that, for two phase flow through the beds packed with small size particles such as 1.5 mm and 2 mm spheres, the contribution of interfacial drag to the pressure drops is weak and ignorable, while the significant effects are conducted on the pressure drops of the beds with bigger size particles like 3 mm and 6 mm spheres, where the interfacial drag in beds with larger particles will result in a descent-ascent tendency in the pressure drop curves along with the fluid velocity, and the effect of interfacial drag should be considered in the debris coolability analysis models for beds with bigger size particles.

Two-Phase Flows and Boiling Heat Transfer in Microchannels

  • Oh, Jong-Taek;Ardiyansyah, Ardiyansyah
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.16 no.2
    • /
    • pp.51-63
    • /
    • 2008
  • A study of literatures on flow boiling heat transfer and two-phase flows inside microchannels is summarized. The potential applications, fabrication method and efforts to determine certain dimensional threshold for microchannels classifications are discussed. For the last two decades, numerous two-phase flow and heat transfer models for microchannels have been developed; many of them were derived from empirical models originally applied for conventional channels. Those models are discussed here along with a brief review on recent development of theoretical and phenomenological-based models for microchannels. This study is devoted to provide a review of important issues on flow boiling heat transfer and two-phase flows inside microchannels, including two-phase flow patterns, boiling heat transfer mechanism and correlations developments, pressure drop and prediction methods, and critical heat flux.

Two-Phase Flow through a T-Junction

  • Tae Sang-Jin;Cho Keum-Nam
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.14 no.1
    • /
    • pp.28-39
    • /
    • 2006
  • Two-phase flow through a T-junction has been studied by numerous researchers so far. The dividing characteristics of the gas and liquid phases at the T-junction are very complicated due to a lot of related variables. The prediction models have been suggested by using experimental data for a specific condition or working fluid. But, they showed the application limitation for the most of the other conditions or fluids. Since most of them are applicable for their own experimental range, the generalized model for the wide range of conditions and fluids is needed. Even though it's not available now, some of the models developed for air-water flow at a T-junction might be applicable for the part of refrigerants with some modifications. Especially, for the two-phase flow of refrigerants at the T-junction, very few studies have been performed. Further experimental study is required to be performed for the wide range of test conditions and fluids to predict properly the two-phase flow distribution and phase separation through the T-junction.

An Experimental Study on the Centrifugal Pump Characteristics in Air-Water Two-Phase Flow (기액 이상류시의 원심펌프특성에 관한 실험적 연구)

  • Kim, Sung-Yoon;Lee, Sang-Il;Kim, You-Taek
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.30 no.6
    • /
    • pp.685-692
    • /
    • 2006
  • In a general centrifugal pump, if it is operated in a two-phase flow the activity of the impeller usually degrades and occasionally losses its function. However, the effect of break down of centrifugal pump due to entrained air has not been clarified yet. This paper shows the air-water two-phase flow characteristics of closed type and semi-open type impellers. In a sing1e-phase flow, closed-type impeller has higher efficiency and head. But in air-water two-phase flow semi-open type impeller's rates of decreases of efficiency and head are decreased.

Counter-Current Air-Water Flow in Narrow Rectangular Channels With Offset Strip Fins

  • Kim, Byong-Joo;Sohn, Byung-Hu;Koo, Kee-Kahb
    • Journal of Mechanical Science and Technology
    • /
    • v.17 no.3
    • /
    • pp.429-439
    • /
    • 2003
  • Counter-current two-phase flows of air- water in narrow rectangular channels with offset strip fins have been experimentally investigated in a 760 mm long and 100 mm wide test section with 3.0 and 5.0 mm gap widths. The two-phase flow regime, channel-average void fractions and two-phase pressure gradients were studied. Flow regime transition occurred at lower superficial velocities of air than in the channels without fins. In the bubbly and slug flow regimes, elongated bubbles rose along the subchannel formed by fins without lateral movement. The critical void fraction for the bubbly-to-slug transition was about 0.14 for the 3 mm gap channel and 0.2 for the 5 mm gap channel. respectively. Channel-average void fractions in the channels with fins were almost the same as those in the channels without fins. Void fractions increased as the gap width increased, especially at high superficial velocity of air. The presence of fins enhanced the two-phase distribution parameter significantly in the slug flow, where the effect of gap width was almost negligible. Superficial velocity of air dominated the two-phase pressure gradients. Liquid superficial velocity and channel gap width has only a minor effect on the pressure gradients.

Flow Pattern Identification of Vertical Upward Two-Phase Flow Using the Attractor-Density-Map Analysis of the Void Fraction Signal in the Nonlinear Phase Space (비선형 위상공간에서의 기포 분율 신호의 끌개밀도분식을 이용한 수직 상향 이상유동의 유동패턴분류)

  • Kim, Nam-Seok;Lee, Jae-Young
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.28 no.11
    • /
    • pp.1398-1406
    • /
    • 2004
  • The nonlinear signals from an impedance meter for the area average void fraction in two-phase flow have been analyzed to construct a phase space trajectory. The pseudo phase space was constructed with the time delay and proper dimensions. The time delay and the embedding dimension were chosen by the average mutual information and by the false nearest neighborhood, respectively. The attractor-density-map of projected states was used to produce the two dimensional probability distribution functions (2D-PDF). Since the developed 2D-PDF showed clear distinction of the flow patterns, the flow regime identification was made with three rules and with the 2D-PDF. Also, the transition criteria of Mishima-Ishii agree well with the present results.

Heat Transfer Correlations for Air-Water Two-Phase Flow of Different Flow Patterns In a Horizontal Pipe

  • Kim, Dongwoo
    • Journal of Mechanical Science and Technology
    • /
    • v.15 no.12
    • /
    • pp.1711-1727
    • /
    • 2001
  • Heat transfer coefficient were measured and new correlations were developed for two-phase heat transfer in a horizontal pipe for different patterns. Flow patterns were observed in a transparent circular pipe (2.54 cm I. D. and L/D=96) using an air/water mixture. Visual identification of the flow patterns was supplemented with photographic data and the results were plotted on the flow regime map proposed by Taitel and Dukler and agreed quite well with each other. A two-phase heat transfer experimental setup was built for this study and a total of 150 two-phase heat transfer data with different flow patterns were obtained under a uniform wall heat flux boundary condition. For these data, the superficial Reynolds number ranged from 640 to 35,500 for the liquid and from 540 to 21,200 for the gas. Our previously developed robust two-phase heat transfer correlation for a vertical pipe with modified constants predicted the horizontal pipe air-water heat transfer experimental data with good accuracy. Overall the proposed correlations predicted the data with a mean deviation of 1.0% and an rms deviation of 12%.

  • PDF

The thermal effect on electrical capacitance sensor for two-phase flow monitoring

  • Altabey, Wael A.
    • Structural Monitoring and Maintenance
    • /
    • v.3 no.4
    • /
    • pp.335-347
    • /
    • 2016
  • One of major errors in flow rate measurement for two-phase flow using an Electrical Capacitance Sensor (ECS) concerns sensor sensitivity under temperature raise. The thermal effect on electrical capacitance sensor (ECS) system for air-water two-phase flow monitoring include sensor sensitivity, capacitance measurements, capacitance change and node potential distribution is reported in this paper. The rules of 12-electrode sensor parameters such as capacitance, capacitance change, and change rate of capacitance and sensitivity map the basis of Air-water two-phase flow permittivity distribution and temperature raise are discussed by ANSYS and MATLAB, which are combined to simulate sensor characteristic. The cross-sectional void fraction as a function of temperature is determined from the scripting capabilities in ANSYS simulation. The results show that the temperature raise had a detrimental effect on the electrodes sensitivity and sensitive domain of electrodes. The FE results are in excellent agreement with an experimental result available in the literature, thus validating the accuracy and reliability of the proposed flow rate measurement system.

A Novel Approach for Well-Test Analysis of Volatile Oil Reservoirs in Two-Phase Flow Conditions

  • Baniasadi, Hamid;Rashidi, Fariborz
    • Korean Chemical Engineering Research
    • /
    • v.57 no.6
    • /
    • pp.883-890
    • /
    • 2019
  • Two-phase flow near the wellbore in volatile oil reservoirs causes complications in well test analysis. In this study, the flow behavior of volatile oil reservoirs below the bubble-point pressure and the potential of radial composite model for interpretation of two-phase well test in volatile oil reservoirs was investigated. A radial composite model was used for two-phase well test analysis. A new procedure was developed to interpret well test data and estimate the radius of the two-phase region. The changes in fluid composition near the wellbore during drawdown test were found to increase the saturation pressure, which affects the saturation profile during build-up. Well test results showed that the radial composite method is a powerful tool for well test characterization and estimation of reservoir parameters. The proposed procedure was able to estimate the reservoir parameters and radius of the two-phase region with acceptable accuracy.