• 제목/요약/키워드: Two transformer

검색결과 552건 처리시간 0.031초

새로운 액티브 전압 클램프 ZVS-PWM 공진 고주파 인버터 (The New Active Voltage Clamp ZVS-PWM Resonant High-frequency Inverter)

  • 안용위;김홍신;문상필;우경일;박한석
    • 전기학회논문지P
    • /
    • 제66권4호
    • /
    • pp.188-193
    • /
    • 2017
  • In this paper, a ZVS-PWM high-frequency inverter with a PWM control function is applied to commercial system 220[Vrms], and a resonator type ZVS-PWM high-frequency inverter circuit with a fixed-two methods were proposed. The parameters of the transformer model equivalent circuit of a copier fixing device, which is an essential element in the parameter optimization of the proposed circuit, are obtained by using a high-frequency amplifier and its frequency characteristics are described. The proposed method compared to the existing single-ended ZVS-PFM high frequency inverter can suppress the voltage and current peak value of the power semiconductor switching device and reduce the switching loss. The efficiency of the proposed method itself is 98[%] at rated power output. Also, the efficiency of 96[%] can be obtained even at low output, so that the proposed high frequency inverter is very efficient inverter. The total efficiency from the commercial AC input to the inverter output is 93[%] at rated, which is considered efficient for use in copying machines. In addition, the diode bridge loss accounts for the largest portion of the overall system efficiency distribution. On the other hand, the nonparallel filter has a very low loss.

지자기 교란으로 인한 전력망 유도전기장 예상값 검증 (Verification on the Calculated Geoelectric Field on Power Grid during Geomagnetic Disturbances)

  • 박성원;유충현
    • 한국전자파학회논문지
    • /
    • 제26권1호
    • /
    • pp.94-100
    • /
    • 2015
  • 태양흑점폭발로 인해 방출되는 코로나 물질은 지자기 교란을 일으킨다. 대규모 지자기 교란으로 인한 유도전류는 변압기 손상을 일으킬 수 있다. 이러한 유도전류를 산출하기 위해 먼저 유도전기장을 산출해야 한다. 푸리에 변환 방법을 적용한 유도전기장 산출방법은 정확도가 높으나, 1일 24시간 동안의 관측 데이터가 필요하다. 반면, 적분 공식을 적용한 유도전기장 산출방법은 실시간 데이터로 산출이 가능하나, 정확도 확인이 요구된다. 이 논문에서 적분 구간을 조정하여 푸리에 변환 방법의 결과값과 오차를 줄이고자 하였다. 그 결과, 적분 공식을 적용한 유도전기장 예상값은 푸리에 변환방법의 예상값과 상관성이 높았으며, 적분 공식으로 산출한 유도전류 예상값은 유도전류 관측값과 시간 동기 및 방향이 일치하고, 그 크기가 오차 범위 1 A 이하에서 92 % 이상 일치함을 확인하였다.

제 2종 LiBr-H2O 흡수식 히트펌프의 운전 변수에 따른 성능 특성 수치 해석 (Effects of Operation Conditions on the Performance of Type II LiBr-H2O Absorption Heat Pump)

  • 윤준성;권오경;차동안;배경진;김인관;김민수;박찬우
    • 설비공학논문집
    • /
    • 제29권1호
    • /
    • pp.7-14
    • /
    • 2017
  • This study carried out a numerical analysis of the effects of hot waste water supply on the performance of a Type II absorption heat pump. There are two types of hot waste water supply, regular series flow and reverse series flow. Also it investigated the interaction between each type of flow and heat exchange solutions. As the effectiveness of heat exchange solutions increase, the steam generation and (COP) increase as well. If the effectiveness of a heat exchange solution is lower than 0.566, the steam generation rate of the reverse flow is lower than that of the regular series flow. A high effectiveness of heat exchange solution is therefore required to make a larger amount of steam in reverse series flow than with ordinary series flow. The COP difference between the two types of flow decreases with the increasing effectiveness of the heat exchange solution. Thus, a reverse flow type absorption heat pump can match the high steam generation rate and COP of the ordinary flow type when a highly effective heat exchange solution is applied.

3상 PFC 부스트 컨버터를 채용한 상압플라즈마 세정기용 고역률 정형파 펄스 출력형 전원장치에 관한 연구 (A Study On High Power Factor Sine Pulse Type Power Supply For Atmospheric Pressure Plasma Cleaning System with 3-Phase PFC Boost Converter)

  • 한희민;김민영;서광덕;김준석
    • 전력전자학회논문지
    • /
    • 제14권1호
    • /
    • pp.72-81
    • /
    • 2009
  • 본 논문에서는 대기압 플라즈마 발생용 정현파펄스형 교류 전원 장치에 대한 연구를 진행하였다. 정현파펄스형 전원장치는 기존의 LC공진을 이용한 교류 전원장치보다 높은 dv/dt를 갖게 되므로 안정적인 플라즈마 공급이 가능하며 펄스형에 비해 고조파 노이즈가 적고, 정전류 턴온-영전압 턴오프 형태로 동작하므로 매우 높은 효율을 갖는다. 또한 플라즈마 점화 기능을 강화하고 안정적인 전압제어를 위해 3상 부스트형 컨버터를 입력단에 사용하여 입력 역률이 매우 높은 시스템을 구성할 수 있다. 실험실 수준의 10kW부하시설을 사용하여 본 연구의 결과를 입증하였다.

경부고속선 절연구간에서 KTX 운행중 모터블럭의 동작특성 분석 (Study on Analysis of Operating Characteristics of Motor Block While KTX is Moving at Neutral Section of Kyung-Bu High Speed Line)

  • 최창현;노영환
    • 전기학회논문지
    • /
    • 제64권10호
    • /
    • pp.1523-1527
    • /
    • 2015
  • Traction power is supplied by three-phase alternating current of 154 kV power grid and electric trains are operated on single phase feeding system. It becomes important to use all the three phases equally and convert them into two-phase electric power (90 degree phase rotation) for traction supply. This is achieved by special transformer from the adjacent traction substation which is separated by a neutral section. Neutral section locations are in front of the substation and between the two substations. The first stage of the Seoul-Busan high-speed railway, design curve radius is larger than 7,000 m and the greatest slope is 25‰. The railway track conditions are evaluated as good enough to install a neutral section at the first stage, but a few factors of coasting operation of the train should be considered at the second stage of Seoul-Busan high-speed railway. The neutral section was located at Kim-cheon substation, which made some neutral section problems produced by the operating train, and the neutral section was moved about 1.5 km to the south toward Dong Dae-gu station due to the track operation condition. Some of the trains which stopped at the existing Kim-cheon Gu-mi station produced another motor block failure after moving the neutral section. In this paper, power quality, system performance and track condition, etc. are suggested to solve the problems.

Investigating the effects of ultra-rapid, rapid vs. final precise orbit and clock products on high-rate GNSS-PPP for capturing dynamic displacements

  • Yigit, Cemal O.;El-Mowafy, Ahmed;Bezcioglu, Mert;Dindar, Ahmet A.
    • Structural Engineering and Mechanics
    • /
    • 제73권4호
    • /
    • pp.427-436
    • /
    • 2020
  • The use of final IGS precise orbit and clock products for high-rate GNSS-PPP proved its effectiveness in capturing dynamic displacement of engineering structures caused by earthquakes. However, the main drawback of using the final products is that they are available after approximately two weeks of data collection, which is not suitable for timely measures after an event. In this study, the use of ultra-rapid products (observed part), which are available after a few hours of data collection, and rapid products, which are available in less than 24 hrs, are investigated and their results are compared to the more precise final products. The tests are designed such that harmonic oscillations with different frequencies and amplitudes and ground motion of a simulated real earthquake are generated using a single axis shake table and the PPP was used to capture these movements by monitoring time-change of the table positions. To evaluate the accuracy of PPP using ultra-rapid, rapid and final products, their results were compared with relative GNSS positioning and LVDT (Linear Variable Differential Transformer) data, treated as reference. The results show that the high-rate GNSS-PPP solutions based on the three products can capture frequencies of harmonic oscillations and dynamic displacement with good accuracy. There were slight differences between ultra-rapid, rapid and final products, where some of the tested events indicated that the latter two produced are more accurate and provide better results compared to the ultra-rapid product for monitoring short-term dynamic displacements.

Loosely Coupled Resonant DAB 컨버터의 안정적인 초기 구동을 위한 동작 주파수 설계 (Operating Frequency Design for Stable Initial Operation of Loosely Coupled Resonant DAB Converter)

  • 백승혁;김성민;이재홍;이승환
    • 전력전자학회논문지
    • /
    • 제26권6호
    • /
    • pp.437-445
    • /
    • 2021
  • This paper proposes an operating frequency design method that limits the voltage applied to aload-side converter during the initial operation of a loosely coupled resonant dual-active bridge (LCR-DAB) converter and an initial operating strategy that applies it. The LCR-DAB converter uses two wireless power transfer coils instead of the high-frequency transformer of the general DAB converter. The wireless power coil has a physical distance of several tens of millimeter or more between the two coils; thus, the LCR-DAB converter is a bidirectional isolated power conversion system that can easily achieve high insulation performance. However, for the initial operation of the LCR-DAB, if the power-side converter is operated at the resonance frequency while the load-side converter is not operating, then a very high voltage due to resonance is applied to the load-side converter, thereby causing damage to the converter. Therefore, a method that can stably charge the DC link voltage of the secondary-side converter during the initial operation is needed. This paper proposes a method to initially charge the secondary-side DC link by operating the primary-side converter at a frequency with limited voltage gain rather than at a steady-state operating frequency. The validity of the proposed frequency design method and initial operating sequence is verified through simulation and experimentation of the 1 KW LCR-DAB converter.

Barton-Bandis 절리 모델에 의한 지하대공동 암주의 변형 특성 연구 (Analysis on the Deformation Characteristics of a Pillar between Large Caverns by Burton-Bandis Rock Joint Model)

  • 강추원;임한욱;김치환
    • 터널과지하공간
    • /
    • 제11권2호
    • /
    • pp.109-119
    • /
    • 2001
  • 우리나라의 양수발전소는 지금까지 단일공동을 굴착하였다. 그러나 양양 양수발전소는 두 개의 대공동 즉, 발전소와 주 변전소로 구성된다. 이 경우 공동 구조물의 안정성, 특히 두 공동사이에 형성되는 암주를 영구적으로 안전하게 유지할 수 있도록 보장되어야 한다. 본 연구에서는 개별요소법을 이용하여 두 공동과 암주의 구조적 안정성을 평가하였으며, 구성모델로 Barton-Bandis의 절리모델을 이용하였다. 현지 암반의 초기응력, 자연절리면의 거칠기계수, 불연속면의 공간적 분포 특성과 같은 중요한 요인들은 현지 조사를 통하여 구하였다. 이외에 두가지 경우 즉, 무보강과 보강의 경우 지보시스템의 최적화를 분석하였으며, 또한 보강효과를 검토하였다. 연구결과 보강의 경우 수평변위와 절리의 전단변위가 감소되었으며 암주내 이완영역 역시 감소됨을 확인하였다. 두 공동사이에 있는 약 36 m 두께의 암주에 적절한 보강조치를 취하여 안정성을 확보할 수 있었다.

  • PDF

ITS용 2층형 전파 흡수체(유전체/자성체) 설계 및 경사 입사 흡수 특성 해석 (Design and Performance Evaluation of Two-Layered Microwave Absorbers(Dielectric/Magnetic) for Wide Oblique Incidence Angles Used for ITS)

  • 김재웅;김성수
    • 한국전자파학회논문지
    • /
    • 제18권11호
    • /
    • pp.1217-1223
    • /
    • 2007
  • 5.8 GHz의 DSRC(Dedicated Short Range Communication) 시스템을 사용하는 ITS(Intelligent Transport System)에 전자파 환경 문제가 발생하면서 광각 경사 입사 대책용 전파 흡수체의 사용이 요구된다. 5.8 GHz 주파수에서 경사 입사된 전파에 대해 낮은 반사 손실을 보이는 2층형의 전파 흡수체(유전 복합 재료/자성 복합 재료)를 설계하였다. 흡수층에는 iron flake를 filler로 사용하였다. 임피던스 정합 기능의 표면층에는 유전상수가 낮은 carbon black을 사용하였다. 각 층의 sheet는 일반적인 세라믹 혼합물 제조 공정에 의해 제작되었고, 지지재로는 가황고무를 사용하였다. 전송 선로 이론에 근거하여 TE(Transverse Electric)와 TM(Transverse Magnetic) 편파에 대해 입사각을 변화시키며 반사 손실을 계산하였고, 자유공간법에 의해 반사 전력을 실측하였다. 입사각 $55^{\circ}$까지 낮은 반사 손실(-10 dB 이하)을 갖는 2층형 흡수체가 설계되었다. 자유공간법에 의한 반사 전력의 실측치가 이론적 계산치와 비슷한 값을 보여 설계 방법의 타당성을 입증할 수 있었다.

저전압 고전류 사양에 적합한 고효율 인터리브 컨버터 (A New High-Efficient Interleaved Converter for Low-Voltage and High-Current Power Systems)

  • 조인호
    • 한국산학기술학회논문지
    • /
    • 제17권10호
    • /
    • pp.600-608
    • /
    • 2016
  • 본 논문은 저전압-고전류 사양을 갖는 전력변환 시스템에 적합한 고효율 인터리브드 방식의 위상천이 풀브릿지 컨버터를 제안한다. 제안하는 컨버터는 1차 측에 '3개의 스위치 브릿지와 2개의 트랜스포머', 2차 측에 '2개의 정류단'으로 구성되어 있다. 2개의 트랜스포머는 각각 동일한 크기의 전력변환을 담당하고, 서로가 위상 차이를 두고 에너지를 전달하는 특징을 갖는다. 이를 통해 기존의 인터리브드 방식의 위상천이 풀브릿지 컨버터 수준의 높은 시스템 안정성을 가지게 된다. 제안하는 컨버터는 기존 컨버터의 효율향상 한계로 작용하였던 lagging-leg 스위치의 하드스위칭 특성을 개선하기 위해 새로운 회로 구조와 제어기법을 적용하였다. 이를 통해 제안하는 컨버터는 기존 컨버터에 비해 하드스위칭 조건을 갖는 스위치의 수를 절반으로 줄였으며, 기존 컨버터에 비해 회로 구성에 사용되는 스위치의 수를 줄여 시스템의 복잡도를 개선하는 효과도 얻었다. 제안하는 컨버터의 특성을 확인하기 위해 본 논문에서는 저전압-고전류 특징을 갖는 3kW 서버용 전원장치 스펙을 이용하여 기존 컨버터와 제안하는 컨버터 시스템을 설계하였고, PSIM 시뮬레이션 툴을 활용하여 두 회로의 동작 특징을 비교하였다.