• 제목/요약/키워드: Two transformer

검색결과 552건 처리시간 0.027초

저스위칭손실 및 저도통손을 갖는 양방향 ZVS PWM Sepic/Zeta 컨버터 (Bidirectional ZVS PWM Sepic/Zeta Converter with Low Conduction Loss and Low Switching Loss)

  • 팽성환;이병철;최성훈;김인동;노의철
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2005년도 전력전자학술대회 논문집
    • /
    • pp.549-551
    • /
    • 2005
  • Bidirectional DC/DC converters allows transfer of power between two dc sources, in either direction. Due to their ability to reverse the direction of flow of power, they are being increasingly used in many applications such as battery charger/dischargers, dc uninterruptible power supplies, electrical vehicle motor drives, aerospace power systems, telecom power supplies, etc. This paper proposes a new bidirectional Sepic/zeta converter. It has low swicthing loss and low conduction loss due to auxiliary communicated circuit and synchronous rectifier operation, respectively. Because of positive and buck/boost-like DC voltage transfer function(M=D/1-D), the proposed converter is very desirable for use in distributed power system . The proposed converter also has both transformerless version and transformer one.

  • PDF

인터리브드 풀 브릿지 컨버터와 단상 하프 브릿지 인버터를 이용한 1.5kW급 PCS 설계 (Design of 1.5kW PCS Using Interleaved Full-Bridge Converter and Single Phase Half-Bridge Inverter)

  • 나광수;나종국;이희준;신수철;원충연
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2013년도 전력전자학술대회 논문집
    • /
    • pp.403-404
    • /
    • 2013
  • In this paper, a PCS which consists of high boost interleaved full-bridge converter and single phase half-bridge inverter is proposed. Proposed PCS is using two full bridge converter modules. PCS consists of parallel input / serial output. It can reduce turn ratio of high frequency transformer. In this paper, PCS which is using 1.5[kW] interleaved full-bridge converter and single phase half bridge inverter is designed and verified stability of system through experiment.

  • PDF

DAB 컨버터의 전도 손실 저감을 위한 가변 주파수의 단일 위상 시프트 변조기법 (Single Phase-Shift Modulation with Variable-Frequency to Reduce Conduction Losses of DAB Converters)

  • 다오녹닷;이동춘
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2019년도 추계학술대회
    • /
    • pp.124-125
    • /
    • 2019
  • This paper proposes a novel control method to minimize conduction losses of dual active bridge (DAB) converters for on-board chargers of electric vehicles (EVs). In the control method, two variables are regulated, which are the phase-shift angle between the primary and secondary full bridges and the switching frequency. From time-domain analysis, an optimal phase-shift angle is derived to achieve the minimum RMS value of the transformer current. The proposed method was implemented for a 3.6-kW SiC-based prototype to validate its effectiveness. A high efficiency over 97.3% has been achieved for a wide output voltage range.

  • PDF

유도 가열기의 제어시스템에 관한 연구 (A Study on Control System Of Induction Heating)

  • 김동운;성낙규;최기수;안규복;이승환;한경희
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 B
    • /
    • pp.1254-1256
    • /
    • 2000
  • In this paper, a control scheme for induction heating is proposed. The propose scheme estimates, resonant frequency by PI control subbing a phase of output voltage and resonant capacitor voltage. There are would be two advantages in the proposed system over existing induction heating system. One is the rapid resonant frequency estimation. A other is the just control of temperature. Power Circuit is used a inverter stack and transformer rated on 5.5kw.

  • PDF

계통의 안정성을 고려한 비선형 FACTS 신경망 제어기설계 (Design of Nonlinear FACTS Controller with Neural Networks for Power System Stabilization)

  • 박성욱;서보혁
    • 전기학회논문지P
    • /
    • 제51권4호
    • /
    • pp.211-218
    • /
    • 2002
  • We propose a intelligent controller for FACTS device to stabilize a power system. In order to identify the nonlinear characteristics of the power system and to estimate a control signal, an artificial neural network is utilized. Parameter and location of Unified Power Flow Controller(UPFC) on power system operating conditions are discussed. A UPFC is composed of an excitation transformer, a boosting, two three-phase GTO based voltage source converters, and a dc link capacitor. The proposed controller is applied to UPFC to verified the effectiveness of the proposed control system. The results show that the proposed nonlinear FACTS controller is able to enhance the transient stability of a three machine and nine bus system.

1, 2종 흡수식 히트펌프의 작동 매체에 따른 성능 해석[I] (Thermodynamic Analysis of an Absorption Heat Pump System with New Working Pairs[I])

  • 원승호;이원용;정헌생
    • 설비공학논문집
    • /
    • 제1권3호
    • /
    • pp.219-227
    • /
    • 1989
  • Performance analysis of an absorption heat pump system for solar energy recovery has been done by computer simulation to find improved working pairs. Based on the thermodynamic analysis, the coefficient of performance and mass flow ratio have been calculated to compare two aqueous solutions [LiCl-water, $LiCi-CaCl_2-Zn(NO_3)_2$-water] which were developed for cooling by others, with the conventional LiBr-water solution. As a result of this analysis, the performances of the new aqueous solutions were found to be better than that of LiBr-water solution not only in cooling systems, but also in heating and in heat transformer systems. Their theoretical thermodynamic performance data were given here with.

  • PDF

FTA기법에 의한 원전기동전원의 이용율 예측에 관한 연구 (A Study on the Availability Prediction of Start-up Power Supply in Nuclear Power Plant by FTAMethod)

  • 최규식
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제48권5호
    • /
    • pp.517-523
    • /
    • 1999
  • The Start-up transformers or on-site stand-by transformers are installed for the start-up and shut-down of generator and emergency status in unclear power plant. The on-site power supply configuration using these transformers must be detemined by considering configuration requirements, site characteristics, reliability and availability severely because it is remarkably important for safety and benefit of plant. The start-up or stand-by power supply configuration has been determined considering only safety requirements and construction cost up to now in Korea. I study various reliability estimating methods for the prediction of availability, and estimate the unavailability for the start-up power supply system of two 1,000㎿ unclear power plants. I also detemine the reliability and unavailability and unavailavility of equipment, system and configuration using FTA method.

  • PDF

IEC 61850 기반의 154kV M.Tr Bay IED 적용 사례 (154kV Main TR. Bay IED Based On IEC 61850)

  • 노재근;오재훈;양항준
    • 전기학회논문지
    • /
    • 제60권11호
    • /
    • pp.2028-2034
    • /
    • 2011
  • Substation Automation System (SAS) based on IEC 61850 is becoming more and more reality in applying power systems. As well, the development of various engineering tools and the convergence with diagnostic systems are underway. To reflect recent advancements in SAS technology, the Korea Electric Power Corporation initiated a 154kV SAS pilot project and a smart power grid business in 2010. In this paper, the authors will summarize the overview and the lessons learned in applying the IEC 61850-based 154kV Main transformer bay IED solutions to these two project.

Analysis, Design, and Implementation of a Single-Phase Power-Factor Corrected AC-DC Zeta Converter with High Frequency Isolation

  • Singh, Bhim;Agrawal, Mahima;Dwivedi, Sanjeet
    • Journal of Electrical Engineering and Technology
    • /
    • 제3권2호
    • /
    • pp.243-253
    • /
    • 2008
  • This paper deals with the analysis, design, and implementation of a single phase AC-DC Zeta converter with high frequency transformer isolation and power factor correction(PFC) in two modes of operation, discontinuous current mode of operation(DCM), and continuous current mode of operation(CCM). A Digital Signal Processor(DSP) based implementation is carried out for validation of the Zeta converter developed design in discontinuous mode of operation. A comparison of both modes of operation is presented for a 1kW power rating from the point of view of steady state and dynamic behavior, power quality, simplicity, control technique, device rating, and converter size. The experimental results of a developed prototype of Zeta converter are presented for validation of the developed design. It is observed that CCM is most suitable for higher power applications where it requires some complex control and sensing of the additional variables.

양방향 풀-브릿지 DC-DC 컨버터를 위한 새로운 소프트 스위칭 기법 (A New Soft Switching Technique for Bi-directional Power Flow, Full-bridge DC-DC Converter)

  • 송유진;박석인;정학근;한수빈;정봉만
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2005년도 학술대회 논문집
    • /
    • pp.251-255
    • /
    • 2005
  • This paper proposes a new soft switching technique for a phase-shift controlled bi-directional DC-DC converter. The described converter employs a low profile high frequency transformer and two active full-bridge converters for bidirectional power flow capability. A new soft switching technique is proposed, which guarantees soft switching over wide range (no load to full load) without any additional circuit components. In the proposed switching scheme, the switch pairs in the diagonal position of the converter each are turned on/off simultaneously by the switching signals with a variable duty ratio depending on the phase shift amount, and the converter is operated without freewheeling interval.

  • PDF