• 제목/요약/키워드: Two transformer

검색결과 552건 처리시간 0.022초

제안된 평면변압기를 이용한 LLC 공진컨버터 (LLC Resonant Converter using Proposed Planar Transformer)

  • 이승민;김은수;정봉근;이재삼;김유선;허동영
    • 전력전자학회논문지
    • /
    • 제17권2호
    • /
    • pp.121-128
    • /
    • 2012
  • In this paper, a new planar transformer with a novel core configuration that can regulate the leakage inductance is proposed and described in detail. In order to design the slim size power system for flat panel TV, Two planar transformers applied to LLC resonant converter are connected in series at primary and in parallel by the center-tap winding at secondary. In this paper, a 300W low profile LLC resonant converter was built and tested to verify the proposed planar transformer.

원형 도파관 정합기의 FDTD에 의한 해석 (Analysis of circular waveguide transformer using FDTD)

  • 이동국;홍재표
    • 한국산업정보학회논문지
    • /
    • 제8권1호
    • /
    • pp.9-17
    • /
    • 2003
  • 본 논문에서는 시간영역 유한차분법(FDTD)을 이용하여 서로 다른 두 원형 도파관의 정합을 위한 원형도파관 정합기를 해석하였다. 축대칭 구조이므로 3차원 문제를 2차원 문제로 변환한 2차원 FDTD 알고리즘을 사용하였고, 상대적으로 반경의 차이가 큰 불연속 도파관에 적용되는 두종류의 정합기를 제안하였다. 하나는 유전체가 부분적으로 채워진 정합기이고, 다른 하나는 테이퍼된 유전체봉이 삽입된 정합기이다. 제안된 정합기에서 정합기의 길이와 직경 및 유전체의 직경 등의 파라미터 변화에 따른 특성을 수치해석하여 비교하였다.

  • PDF

765kV 변압기 탱크 분리운전 (Devided operation by each Tank of 765kV Transformer)

  • 김문덕;정시환;박종명
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 E
    • /
    • pp.2317-2319
    • /
    • 1999
  • 765kV Transformer, bank capacity is 2,000MVA, is developed of two seperated tanks per phase because transportation weight of the transformer needs to be reduced. So we will operate one tank per phase in some case, low load or black down of 1 tank, using the one phase-two tank type of 765kV transformer to cut down the cost and improve the reliability of substation.

  • PDF

고온초전도변압기의 특성해석 (The Characteristics Analysis of a HTS Transformer)

  • 이희준;차귀수;이용욱;한송엽
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제49권1호
    • /
    • pp.27-31
    • /
    • 2000
  • This paper presents the performance evaluation of an HTS transformer. Numerical calculation by finite element method was used to evaluate the performance. BSCCO-2223 HTS tapes and double pancake winding were adopted in this design. Four double pancake windings were used in total. Among them two windings were connected in series for high voltage winding and two windings are connected in parallel for low voltage winding. Propertied of various type of the winding arrangement were examined. Characteristics of the transformer during the transient which was caused by sudden short were simulated. The current limiting effect, temperature rise and resistance growth of the superconducting winding were shown.

  • PDF

High-Frequency Forward Transformer Linked PWM DC-DC Power Converter with Zero Voltage Switching and Zero Current Switching Bridge Legs

  • Moisseev, Serguei;Hamada, Satoshi;Ishitobi, Manabu;Hiraki, Eiji;Nakaoka, Mutsuo
    • Journal of Power Electronics
    • /
    • 제2권4호
    • /
    • pp.278-287
    • /
    • 2002
  • A novel zero-voltage and zero-current switching PWM DC-DC converter with lowered conduction losses is presented in this paper. A new double two-switch forward high frequency transformer type soft-switching converter topology is developed to minimize circulating currents occurs during freewheeling period. This converter has advantages as less number of the components, simple control principle under constant operation frequency, free of transformer Imbalance effect. The principle of operation is illustrated with steady-state analysis. Moreover, the effectiveness of the proposed converter topology is verified by implementation of a 500w-100kHz breadboard using IGBTs.

전압, 전류 변화 추이를 이용한 전력용 변압기 보호계전 알고리즘 (A New Protective Relaying Algorithm for Power Transformer Based on Three Phase Voltage and Current)

  • 김상태;이승재;강상희;진보건;윤상현;이태성
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제50권4호
    • /
    • pp.157-165
    • /
    • 2001
  • The two criteria to identify the disturbances of the power transformer has been reported in this paper. They have been derived through EMTP simulations of internal faults, inrush and overexcitation for the model of 154/22.9[kV], 40[MVA], Y-Y three-phase power transformer. We propose the crisp algorithm which uses two criteria. A series of test results clearly indicate that the method can identify not only an internal fault but also the other transients. The average of relay operation times is about 7.2[ms]. The proposed algorithm immunes to the transient state.

  • PDF

식물유 및 광유를 사용한 배전변압기의 열열화에 따른 절연유의 코로나 개시전압 및 전기적 특성에 대한 연구 (A Study on Corona Inception Voltage and Dielectric Characteristics of Thermally Aged Mineral and Vegetable Insulation Oil in Medium Voltage Power Transformer)

  • 정중일;허창수
    • 전기학회논문지
    • /
    • 제66권12호
    • /
    • pp.1745-1750
    • /
    • 2017
  • Starting from the distribution transformer, the insulation oil for the oil immersed power transformer is being used to convert the vegetable oil from the existing mineral oil. Vegetable oil is better in temperature characteristics and insulation performance, is not toxic, and has better biodegradable characteristic than that of mineral oil. In order to investigate the corona inception voltage and dieclectic charateristics of the two insulating oils, three oil immersed transformers using mineral oil and vegetable oil were made and thermal cyclic aged. In this paper, the changes in the corona discharge inception voltage, chemical and electrical properties of the two sampled insulating oils from the transformers had been studied.

An Ensemble Model for Credit Default Discrimination: Incorporating BERT-based NLP and Transformer

  • Sophot Ky;Ju-Hong Lee
    • 한국정보처리학회:학술대회논문집
    • /
    • 한국정보처리학회 2023년도 춘계학술발표대회
    • /
    • pp.624-626
    • /
    • 2023
  • Credit scoring is a technique used by financial institutions to assess the creditworthiness of potential borrowers. This involves evaluating a borrower's credit history to predict the likelihood of defaulting on a loan. This paper presents an ensemble of two Transformer based models within a framework for discriminating the default risk of loan applications in the field of credit scoring. The first model is FinBERT, a pretrained NLP model to analyze sentiment of financial text. The second model is FT-Transformer, a simple adaptation of the Transformer architecture for the tabular domain. Both models are trained on the same underlying data set, with the only difference being the representation of the data. This multi-modal approach allows us to leverage the unique capabilities of each model and potentially uncover insights that may not be apparent when using a single model alone. We compare our model with two famous ensemble-based models, Random Forest and Extreme Gradient Boosting.

초전도 변압기 교류 손실 해석 (Analysis of AC Losses in HIS Transformer with Double Pancake Windings)

  • 김종태;김우석;김성훈;최경달;주형길;홍계원;한진호;이희균
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제54권1호
    • /
    • pp.17-21
    • /
    • 2005
  • AC loss is one of the important parameters in HTS (High Temperature Superconducting) AC devices. Among the HTS AC power devices, the transformer is the essential part in the electrical power system. But unfortunately, the transformer is the worst HTS device concerning AC loss because of very large magnetization loss due to high magnetic field applied to the HTS wire. We calculated the magnetization losses in HTS pancake windings for transformer according to the operating temperature. Two kinds of arrangement of HTS pancake windings were adopted for calculation of AC losses of a shell type transformer, and the analysis results were presented and discussed.

PSCAD를 이용한 전력용 변압기 모델링과 과도 해석 (Power Transformer Modeling and Transient Analysis using PSCAD)

  • 박철원
    • 전기학회논문지P
    • /
    • 제65권2호
    • /
    • pp.122-129
    • /
    • 2016
  • Current differential protection relaying with second harmonic restraint is the main protection for large capacity power transformer. PSCAD simulation program is widely used for modeling of dynamic varying transients phenomena. This paper deals with a power transformer model and transients analysis using PSCAD software to develop IED for power transformer. Simulation was carried out using a three phase 40MVA, 154/22.9kV, 60Hz, two-winding transformer with Y-Y connection used in actual fields. The paper analyzed transformer magnetizing inrush, external fault, and internal fault conditions with this model in the time domain. In addition, we performed an analysis in the frequency domain using FFT during several conditions.