• 제목/요약/키워드: Two transformer

검색결과 556건 처리시간 0.03초

저온소결 PMN-PNN-PZT계 세라믹스를 이용한 Rosen형 압전변압기의 전기적 특성 (Electrical Properties of Rosen Type piezoelectric transformers using Low Temperature Sintering PMN-PNN-PZT ceramics)

  • 이상호;류주현;김인성;송재성
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2008년도 하계학술대회 논문집 Vol.9
    • /
    • pp.53-53
    • /
    • 2008
  • Piezoelectric transformers have been widely used such as DC-DC convertor, invertor, Ballast, etc. Because, the y have some merits compared with electro-magnetic transformers such as step-up ratio, high efficiency, small size and lg hit weight, etc. Piezoelectric transformer require high electromechanical coupling factor kp in order to induce a large out put power in proportional to applied electric field. And also, high mechanical quality factor Qm is required to prevent mechanical loss and heat generation. In general, PZT system ceramics should be sintered at high temperatures between 1200 and $1300^{\circ}C$ in order to obtain complete densification. Accordingly, environmental pollution due to its PbO evaporation. Hence, to reduce its sintering temperature, various kinds of material processing methods such as hot pressing, high energy mill, liquid phase sintering, and using ultra fine powder have been performed. Among these methods, liquid phase sintering is basically an effective method for aiding densification at low temperature. In this study, In order to comparis on low temperature sintering and solid state sintering piezoelectric transformers, rosen type transformers were fabricated u sing two PZT ceramics compositions and their electrical properties were investigated.

  • PDF

A New LLC Resonant Converter with Multiple Outputs for High Efficiency and Low Cost PDP Power Module

  • Kim, Chong-Eun;Yi, Kang-Hyun;Moon, Gun-Woo;Lee, Buem-Joo;Kim, Sang-Man
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2005년도 전력전자학술대회 논문집
    • /
    • pp.439-441
    • /
    • 2005
  • A new LLC resonant converter with multiple outputs is proposed for high efficiency and low cost plasma display panel (PDP) power module. In the proposed converter, ZVS turn-on of the primary MOSFETs and ZCS nun-off of the secondary diodes are guaranteed in the overall input voltage and output load range. Moreover, the primary MOSFETs and the secondary diodes have low voltage stresses clamped to input and the output voltage, respectively. Therefore, the proposed converter shows the high efficiency due to the minimized switching and conduction losses. In addition, by employing the transformer, which has the two and more secondary side, the proposed converter can have multiple outputs and they show the great cross-regulation characteristics. As a result, the proposed converter can be implemented with low cost and compact size. The 500W prototype is implemented, which integrates the sustaining and addressing power supplies of PDP power module. The maximum efficiency is 96.8% and the respective output voltages are well regulated. Therefore, the proposed converter is suitable for high efficiency and low cost PDP power module.

  • PDF

Current-induced Phase Demodulation Using a PWM Sampling for a Fiber-optic CT

  • Park, Hyoung-Jun;Lee, June-Ho;Kim, Hyun-Jin;Song, Min-Ho
    • Journal of the Optical Society of Korea
    • /
    • 제14권3호
    • /
    • pp.240-244
    • /
    • 2010
  • In this work, we used PWM sampling for demodulation of a fiber-optic interferometric current transformer. The interference signal from a fiber-optic CT is sampled with PWM triggers that produce a 90-degree phase difference between two consecutively sampled signals. The current-induced phase is extracted by applying an arctangent demodulation and a phase unwrapping algorithm to the sampled signals. From experiments using the proposed demodulation, we obtained phase measurement accuracy and a linearity error, in AC current measurements, of ~2.35 mrad and 0.18%, respectively. The accuracy of the proposed method was compared with that of a lock-in amplifier demodulation, which showed only 0.36% difference. To compare the birefringence effects of different fiber-optic sensor coils, a flint glass fiber and a standard single-mode fiber were used under the same conditions. The flint glass fiber coil with a Faraday rotator mirror showed the best performance. Because of the simple hardware structure and signal processing, the proposed demodulation would be suitable for low-cost over-current monitoring in high voltage power systems.

고주파방식 충전기 개발을 위한 페라이트 변압기 설계에 관한 연구 (The Study of the Ferrite Transformer Design for the Development of the High-frequency Battery Charger)

  • 안용호;박종광;김상준;윤장완;윤기웅;한병성
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2000년도 하계학술대회 논문집
    • /
    • pp.683-686
    • /
    • 2000
  • The chargers for DC power supply of the contro1lers, which have been installed in the relay rooms in 345/154kV substations of KEPCO, lag in both aspects of technique and performance. Moreover, as they are SCR-based, they dont meet the performance requirements of todays digital and automated controllers. Now two controllers are running in pair and one of those is for reservation. There are lots of troubles because the patrol engineering team has to replace them manually whenever they are out of order. So it is expected to bring convenience if the charger replacement is automated. Also, the existing chargers take much space, weight and cost - which have increased the need of development to make them smaller, less expensive, and have high quality. We will develop a charger system which has one fifth of the weight of the existing system by double-integrating the volume. The new system will be ready for a future full unmanned system with integrated pores for remote control, state-of-the-art digital features, and more than 90% efficiency/power factor against 80% efficiency/power factor of the existing system.

  • PDF

Numerical Study of Estimating the Arrival Time of UHF Signals for Partial Discharge Localization in a Power Transformer

  • Ha, Sang-Gyu;Cho, Jeahoon;Lee, Juneseok;Min, Byoung-Woon;Choi, Jaehoon;Jung, Kyung-Young
    • Journal of electromagnetic engineering and science
    • /
    • 제18권2호
    • /
    • pp.94-100
    • /
    • 2018
  • Partial discharges (PDs) are electrical sparks that occur inside insulation between two conducting electrodes and can lead to the disastrous failure of insulation systems. To determine the location of a PD, a distributed array of UHF PD sensors is used to detect the electromagnetic (EM) signals emitted from the PD source, and the localization of the PD source can be estimated using the time difference of arrival (TDOA) between EM signals captured by the UHF PD sensor array. There are four popular methods to estimate the TDOA-the first peak method, the cross-correlation method, the energy criterion method, and the average time window threshold method. In this work, we numerically investigate the influence of noise on estimating the TDOA for the four different methods. Numerical results show that the energy criterion method is more robust against noise than other methods.

새로운 능동형 고역률 다이오드 정류기시스템 (A New High Power Factor Correction Diode Rectifier System)

  • 김현정;최세완;원충연;김규식
    • 전력전자학회논문지
    • /
    • 제8권6호
    • /
    • pp.543-550
    • /
    • 2003
  • 본 논문에서는 2대의 다이오드 정류기에 부스트 컨버터를 이용하여 전류의 파형을 능동적으로 만들어 정현파의 입력전류를 얻는 새로운 방식의 고조파 저감방식을 제안한다. 제안한 방식으로 고역률의 전원 품질을 얻을 수 있으며 입력측의 변동에 대한 출력전압의 조정도 가능하다. 또한 저감된 용량을 갖는 3상 오토트랜스포머의 사용으로 기존의 $\Delta$-Y 변압기에 비해 KVA정격이 75% 절감되며 상간변압기도 필요 없다. 본 방식을 소형화와 고품질의 전원이 요구되는 통신용 정류기등에 적용하면 효과적이다. 제안한 방식의 동작원리, 제어 및 설계방법을 기술하고 1.5KW급 시작품으로부터의 실험결과를 제시한다.

Current Sensorless MPPT Control Method for Dual-Mode PV Module-Type Interleaved Flyback Inverters

  • Lee, June-Hee;Lee, June-Seok;Lee, Kyo-Beum
    • Journal of Power Electronics
    • /
    • 제15권1호
    • /
    • pp.54-64
    • /
    • 2015
  • This paper presents a current sensorless maximum power point tracking (MPPT) control method for dual-mode photovoltaic (PV) module-type interleaved flyback inverters (ILFIs). This system, called the MIC (Module Integrated Converter), has been recently studied in small PV power generation systems. Because the MIC is an inverter connected to one or two PV arrays, the power system is not affected by problems with other inverters. However, since the each PV array requires an inverter, there is a disadvantage that the initial installation cost is increased. To overcome this disadvantage, this paper uses a flyback inverter topology. A flyback inverter topology has an advantage in terms of cost because it uses fewer parts than the other transformer inverter topologies. The MPPT control method is essential in PV power generation systems. For the MPPT control method, expensive dc voltage and current sensors are used in the MIC system. In this paper, a MPPT control method without current sensor where the input current is calculated by a simple equation is proposed. This paper also deals with dual-mode control. Simulations and experiments are carried out to verify the performance and effectiveness of the proposed current sensorless MPPT control method on a 110 [W] prototype.

하이브리드 차량 및 전기 차량용 두 개의 인덕터와 하나의 변압기를 갖는 새로운 비절연형 부스트 컨버터 (A New Non-isolated Boost Converter with Two-Inductor and One-Transformer for Hybrid Electric Vehicle and Electric Vehicle)

  • 성현욱;박기범;김태성;문건우;윤명중
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2007년도 하계학술대회 논문집
    • /
    • pp.132-134
    • /
    • 2007
  • 하이브리드 차량 및 전기차량 구동 모터의 권선저항에 의한 손실 및 모터의 크기를 줄이기 위해 고효율, 고승압형 DC-DC 컨버터 사용이 요구된다. 기존의 부스트 컨버터는 기생저항 성분에 의해 고승압이 불가능하여 변압기를 사용하여 승압비를 향상시킨 current-fed push-pull, current-fed full bridge, dual inductor-fed 부스트 컨버터 등으로 변형되어 사용되어 왔다. dual inductor-fed 부스트 컨버터의 경우 동일조건하에서 앞서 기술된 2가지 컨버터보다 2배의 승압비를 얻을 수 있으며 1차측 전류 스트레스가 낮은 장점을 가지고 있어 대전력, 고승압 응용에 적합하다. 하지만 변압기의 누설인덕턴스에 의한 써지성 전류/전압을 제한하기 위한 부가적인 snubber회로의 사용으로 효율을 떨어뜨리게 되는 단점을 가지고 있다. 본 논문에서는 이러한 단점을 보완할 수 있는 새로운 2개의 인덕터와 1개의 변압기를 갖는 DC-DC 컨버터를 제안한다. 제안된 컨버터의 동작원리와 모드해석을 실시하고 최종적으로 400W, 42Vdc (Battery)/400Vdc (Electric Motor) 실험결과를 통해 이를 검증한다.

  • PDF

Analysis and Design of Coupled Inductors for Two-Phase Interleaved DC-DC Converters

  • Lee, Jong-Pil;Cha, Honnyong;Shin, Dongsul;Lee, Kyoung-Jun;Yoo, Dong-Wook;Yoo, Ji-Yoon
    • Journal of Power Electronics
    • /
    • 제13권3호
    • /
    • pp.339-348
    • /
    • 2013
  • Multiphase dc-dc converters are widely used in modern power electronics applications due to their advantages over single-phase converters. Such advantages include reduced current stress in both the switching devices and passive elements, reduced output current ripple, and so on. Although the output current ripple of a converter can be significantly reduced by virtue of the interleaving effect, the inductor current ripple cannot be reduced even with the interleaving PWM method. One way to solve this problem is to use a coupled inductor. However, care must be taken in designing the coupled inductor to maximize its performances. In this paper, a detailed analysis of a coupled inductor is conducted and the effect of a coupled inductor on current ripple reduction is investigated extensively. From this analysis, a UU core based coupled inductor structure is proposed to maximize the performance of the coupled inductor.

신재생에너지용 연계형 인버터의 고효율 승압에 관한 연구 (Study on High Efficiency Boosting-up Circuit for Renewable Energy Application)

  • 정태욱;김주용;최세권;조준석;고희석
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2009년도 춘계학술대회 논문집
    • /
    • pp.336-339
    • /
    • 2009
  • In this paper, such as battery power or solar energy and fuel cells generated from Renewable energy sources, high voltage to low voltage DC-DC Converter for converting the design of the study. System consists of low voltage ($24{\sim}28$ [VDC]) and Boosts the voltage (270 [VDC]) for a 3 [kW] DC-DC converter and control circuit is configured as, Power switch the ST Tomson's Automotive low voltage high current MOSFET switches STE250NS10S (temperature 250A) was applied to the two parallel. Also, Controller's processor used ATMEGA128, and Gate Drive applies and composed Photo Coupler TLP250. development. Input voltage (24V) and output voltage (270V) for Conversion in the H-bridge converter topology of the circuit output side power and voltage to control the implementation of the Phase shift angle control applied. And, 3kW of power to pass appropriate specification of the secondary side as interpreted by the high frequency transformer, and the experimental production and analysis of the experiment

  • PDF