• 제목/요약/키워드: Two layer

검색결과 6,123건 처리시간 0.043초

지표 건물이 도시유역의 침수특성에 미치는 영향 (Impact of Building Blocks on Inundation Level in Urban Drainage Area)

  • 이정영;하성룡
    • 환경영향평가
    • /
    • 제22권1호
    • /
    • pp.99-107
    • /
    • 2013
  • This study is an impact assessment of building blocks on urban inundation depth and area. LiDAR data is used to generate two original data set in terms of DEM with $5{\times}5$ meter and building block elevation layer of the study drainage area in Cheongju and then the building block elevation layer is modified again to the mesh data with same size to DEM. Two-dimensional inundation analysis is carried out by applying 2D SWMM model. The inundation depth calculated by using the building block elevation layer shows higher reliability than the DEM. This is resulted from the building block interference to surface flow. In addition, the maximum flooded area by DEM is two times wider than the area by building block layer. In the case of the surface velocity, the difference of velocity is negligible in either DEM or building block case in the low building impact zone. However, If the impact of building on the surface velocity was increase, the gap of velocity was significant.

인체전류를 기반으로 하는 감전의 위험성 평가방법 (A Method for Evaluating Electric Shock Hazards Based on Human Body Current)

  • 이복희;유양우;최종혁
    • 조명전기설비학회논문지
    • /
    • 제25권6호
    • /
    • pp.108-114
    • /
    • 2011
  • In order to mitigate the possible hazards from electric shock due to the touch and step voltages, the high resistivity material such as gravel is often spread on the earth's surface in substations. When the grounding electrode is installed in two-layer soil structures, the surface layer soil resistivity is different with the resistivity of the soil contacted with the grounding electrodes. The design of large-sized grounding systems is fundamentally based on assuring safety from dangerous voltages within a grounding grid area. The performance of the grounding system is evaluated by tolerable touch and step voltages. Since the floor surface conditions near equipment to be grounded are changed after a grounding system has been constructed, it may be difficult to determine the tolerable touch and step voltage criteria. In this paper, to propose an accurate and convenient method for evaluating the protective performance of grounding systems, the propriety of the method for evaluating the current flowing through the human body around on a counterpoise buried in two-layer soils is presented. As a result, it is reasonable that the grounding system performance would be evaluated by measuring and analyzing the current flowing through the human body based on dangerous voltages such as the touch or step voltages and the contact resistance between the ground surface and feet.

Discrete-Layer Model for Prediction of Free Edge Stresses in Laminated Composite Plates

  • Ahn, Jae-Seok;Woo, Kwang-Sung
    • 한국전산구조공학회논문집
    • /
    • 제23권6호
    • /
    • pp.615-626
    • /
    • 2010
  • The discrete-layer model is proposed to analyze the edge-effect problem of laminates under extension and flexure. Based on three-dimensional elasticity theory, the displacement fields of each layer in a laminate have been treated discretely in terms of three displacement components across the thickness. The displacement fields at bottom and top surfaces within a layer are approximated by two-dimensional shape functions. Then two surfaces are connected by one-dimensional high order shape functions. Thus the p-convergent refinement on approximated one- and two-dimensional shape functions can be implemented independently of each other. The quality of present model is mostly determined by polynomial degrees of shape functions for given displacement fields. For nodal modes with physical meaning, the linear Lagrangian polynomials are considered. Additional modes without physical meaning, which are created by increasing nodeless degrees of shape functions, are derived from integrals of Legendre polynomials which have an orthogonality property. Also, it is assumed that mapping functions are linear in the light of shape of laminated plates. The results obtained by this proposed model are compared with those available in literatures. Especially, three-dimensional out-of-plane stresses in the interior and near the free edges are evaluated and convergence performance of the present model is established with the stress results.

A load-bearing structural element with energy dissipation capability under harmonic excitation

  • Pontecorvo, Michael E.;Barbarino, Silvestro;Gandhi, Farhan S.;Bland, Scott;Snyder, Robert;Kudva, Jay;White, Edward V.
    • Advances in aircraft and spacecraft science
    • /
    • 제2권3호
    • /
    • pp.345-365
    • /
    • 2015
  • This paper focuses on the design, fabrication, testing and analysis of a novel load-bearing element with energy dissipation capability. A single element comprises two von-Mises trusses (VMTs), which are sandwiched between two plates and connected to dashpots that stroke as the VMTs cycle between stable equilibrium states. The elements can be assembled in-plane to form a large plate-like structure or stacked with different properties in each layer for improved load-adaptability. Also introduced in the elements are pre-loaded springs (PLSs) that provide high initial stiffness and allow the element to carry a static load even when the VMTs cannot under harmonic disturbance input. Simulations of the system behavior using the Simscape environment show good overall correlation with test data. Good energy dissipation capability is observed over a frequency range from 0.1 Hz to 2 Hz. The test and simulation results show that a two layer prototype, having one soft VMT layer and one stiff VMT layer, can provide good energy dissipation over a decade of variation in harmonic load amplitude, while retaining the ability to carry static load due to the PLSs. The paper discusses how system design parameter changes affect the static load capability and the hysteresis behavior.

신체 부위에 따른 지방조직의 특성: 컴퓨터단층촬영 및 조직학적 소견 (Characteristics of Fat Tissue According to the Anatomical Regions of the Body: Computed Tomographic and Histological Findings)

  • 신동우;손대구;박무식;김준형;한기환
    • Archives of Plastic Surgery
    • /
    • 제37권5호
    • /
    • pp.535-546
    • /
    • 2010
  • Purpose: The subcutaneous fat tissue is separated into 2 layers by the subcutaneous fascia: the superficial and deep fat layers. The two fat layers have different structures according to the body regions. The purpose of this study is to evaluate the distribution and pattern of the two fat layers in the human body by computed tomography (CT) and histological analysis according to age, sex, anatomical region, and body mass index (BMI). Methods: This study included 200 males and 200 females who underwent 64-channel dynamic CT in our hospital. The patients were divided into 5 groups according to 10 years of their ages separately in either male or female gender. The thickness of the superficial and deep fat layers was measured in the abdominal, pelvic, and femoral regions, and we analyzed the values. Statistical analyses were performed using SPSS software. The $3{\times}3$-cm whole fat layers were harvested from the same sites of 3 cadavers for histological examination, and one cadaver was dissected for gross evaluation. Results: The total thickness of subcutaneous fat tissue was greater in females than in males, and the ratio of the superficial fat layer to the whole fat layer was higher in females. The superficial fat layer became thinner with increasing age in males. As BMI increased, the total fat layer became thicker, and the superficial fat layer became thicker than the deep fat layer. On histological examination, the superficial fat layer had small adipose lobules and showed a densely distributed pattern in the abdominal region, whereas in the femoral region, it had large adipose lobules and showed a sparsely distributed pattern. There were no significant differences in the histological findings of the deep fat layer between the 3 body regions. Conclusion: Significant differences in histological findings of the two fat layers were found in relation to age, sex, anatomical region, and BMI. The superficial fat layer became thinner with increasing age in males, but it was constant in females. As BMI increased, the total thickness of subcutaneous fat tissue became greater, and the superficial fat layer became thicker than the deep fat layer. Our measurements can be used to understand the characteristics of the fat layers in relation to age, sex, anatomical region, and BMI.

Secure Transmission for Two-Way Vehicle-to-Vehicle Networks with an Untrusted Relay

  • Gao, Zhenzhen
    • IEIE Transactions on Smart Processing and Computing
    • /
    • 제4권6호
    • /
    • pp.443-449
    • /
    • 2015
  • This paper considers the physical layer security problem for a two-way vehicle-to-vehicle network, where the two source vehicles can only exchange information through an untrusted relay vehicle. The relay vehicle helps the two-way transmission but also acts as a potential eavesdropper. Each vehicle has a random velocity. By exploiting the random carrier frequency offsets (CFOs) caused by random motions, a secure double-differential two-way relay scheme is proposed. While achieving successful two-way transmission for the source vehicles, the proposed scheme guarantees a high decoding error floor at the untrusted relay vehicle. Average symbol error rate (SER) performance for the source vehicles and the untrusted relay vehicle is analyzed. Simulation results are provided to verify the proposed scheme.

폴리머 분말 혼입율에 따른 2층 포장용 고성능 콘크리트의 자기수축 특성 (Shrinkage Cracking Resistance of a Very High Performance Concrete for 2LCP in Accordance with the Polymer Powder Mixing Rate)

  • 윤병림;윤경구;이겨레;한승연
    • 한국도로학회논문집
    • /
    • 제20권2호
    • /
    • pp.19-25
    • /
    • 2018
  • PURPOSES : This purpose of this study is to analyze the effect to autogenous shrinkage of the top-layer material of a two-lift concrete pavement mixing both silica fume and polymer powder. METHODS : The bottom-layer of a two-lift concrete pavement was paved with original portland cement (OPC) with a 20~23 cm thickness. Additionally, the top-layer which is directly exposed to the environment and vehicles was paved with a high-performance concrete (HPC) with a 7~10 cm thickness. These types of pavements can achieve a long service life by reducing joint damage and increasing the abrasion and scaling resistance. In order to integrate the different bottom and top layer materials, autogenous shrinkage tests were performed in this study according to the mixing ratio of silica fume and polymer powder, which are the admixture of the top-layer material. RESULTS : Autogenous shrinkage decreased when polymer powder was used in the mix. Contrary to this, autogenous shrinkage tended to rise with increasing silica fume content. However, the effects were not significant when small amounts of polymer powder were used (3% and 11%). CONCLUSIONS : The durability and compressive strength increase when silica fume is used in the mix. The flexural strength considerably increases and autogenous shrinkage of concrete decreases when polymer powder is used in the mix. As seen from above, the proper use of these materials improves not only durability, but also autogenous shrinkage, leading to better shrinkage crack control in the concrete.

Study on Validity of 1-D Spherical Model on Aqua-plasma Power Estimation With Electrode Structure

  • 윤성영;장윤창;김곤호
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2010년도 제39회 하계학술대회 초록집
    • /
    • pp.74-74
    • /
    • 2010
  • The aqua-plasma is the non-thermal plasma in electrical conductive electrolyte by generates the vapor film layer on the immersed metal electrode surface. This plasma can generate the hydroxyl radical by dissociate the water molecule with the plasma electron. To develop the plasma discharge device for high efficiency in the hydroxyl radical generation, proper model for estimation of plasma power is necessary. In this work, the 1-D spherical model was developed, considering temperature dependence material constants. The relation between the plasma power and hydroxyl generation was also studied by the comparison between the optical emission intensity from the hydroxyl radical using monochromator and estimated plasma power. First, the thickness of vapor layer thickness was estimated using the Navier-Stokes fluid equation in order to calculate the discharge E-field inside vapor layer. Using the E-field magnitude and power balance on the plasma generation, it was possible to estimate the plasma power. The plasma power was assumed to uniformly fill the vapor layer and the temperature of vapor layer was fixed in the boiling temperature of electrolyte, 375K. In the experiment, the aqua-plasma was discharged in the saline by applied the voltage on the bipolar electrode. The range of applied voltage was 234 to 280V-rms in the frequency of 380 kHz. Two type electrodes were produced with two ${\Phi}0.2$ tungsten. The plasma power was estimated from the V-I signal from the two high voltage probes and current probe. The estimated plasma power agreed with the profile of emission intensity when the plasma discharged between the metal electrode and vapor layer surface. However, when the plasma discharged between the metal electrodes, the increasing rate of emission intensity was lower than the increase of plasma power. It implies that the surface reaction is more sufficient rather than the volume reaction in the radical generation, due to the high density of water molecule in the liquid.

  • PDF

시안기를 가진 유기 EL 물질들의 합성 및 유기 EL 소자에서의 발광특성평가 (Synthesis of Organic EL Materials with Cyano Group and Evaluation of Emission Characteristics in Organic EL Devices)

  • 김동욱
    • 대한화학회지
    • /
    • 제43권3호
    • /
    • pp.315-320
    • /
    • 1999
  • 고성능 전계발광(electroluminescent, EL) 소자에 사용되는 발광물질의 개발을 위하여 설계된 발광기능기의 분자구조는 비스스틸렌구조의 발광기능기에 전자주입과 수송을 위한 시안기와 정공주입과 수송을 위한 페닐아민기를 가진 구조이다. 위의 발광기능기로 구성 된 고분자물질, PU-BCN과 저분자물질, D-BCN을 합성하였다. PU-BCN과 D-BCN을 발광층으로 사용하여 만들어진 단층형 소자(SL)의 구조는 Indium-tin oxide(ITO)/발광층/MgAg이고, 적층형소자의 구조는 ITO/발광층/oxadiazole dehvative/MgAg, (DL-E)와 ITO/tri-phenylamine derivative/발광층/MgAg,(DL-H)의 두 종류이다. 동일한 발광기능기를 가진 고분자 발광물질, PU-BCN과 저분자발광물질, D-BCN은 전하주입과 수송성이 띄어난 물질로 평가되었으며, 두 발광물질들은 높은 전류밀도하에서 거의 동일한 발광특성을 보였다. 발광물질들의 최대 발광 피이크는 약 640 nm의 적색 발광영역에서 측정되었다.

  • PDF

Evaluation of the effects of two novel irrigants on intraradicular dentine erosion, debris and smear layer removal

  • Gorduysus, Melahat;Kucukkaya, Selen;Bayramgil, Nursel Pekel;Gorduysus, Mehmet Omer
    • Restorative Dentistry and Endodontics
    • /
    • 제40권3호
    • /
    • pp.216-222
    • /
    • 2015
  • Objectives: To evaluate the effects of copolymer of acrylic acid and maleic acid (Poly[AA-co-MA]) and calcium hypochlorite ($Ca(OCl)_2$) on root canal dentin using scanning electron microscope (SEM). Materials and Methods: Twenty-four single-rooted teeth were instrumented and the apical and coronal thirds of each root were removed, leaving the 5 mm middle thirds, which were then separated into two pieces longitudinally. The specimens were randomly divided into six groups and subjected to each irrigant for 5 min as follows: G1, $Ca(OCl)_2$; G2, Poly(AA-co-MA); G3, $Ca(OCl)_2$ + Poly(AA-co-MA); G4, sodium hypochlorite (NaOCl); G5, ethylenediaminetetraacetic acid (EDTA); G6, NaOCl+EDTA. The specimens were prepared for SEM evaluation. Smear layer, debris and erosion scores were recorded by two blinded examiners. One image from G3 was analyzed with energy dispersive spectroscopy (EDS) on suspicion of precipitate formation. Data were analyzed using the Kruskal-Wallis and Dunn tests. Results: G1 and G4 showed the presence of debris and smear layer and they were statistically different from G2, G3, G5 and G6 where debris and smear layer were totally removed (p < 0.05). In G1 and G4, erosion evaluation could not be done because of debris and smear layer. G2, G3 and G5 showed no erosion, and there was no significant difference between them. G6 showed severe erosion and was statistically different from G2, G3 and G5 (p < 0.05). EDS microanalysis showed the presence of Na, P, and Ca elements on the surface. Conclusions: Poly(AA-co-MA) is effective in removing the smear layer and debris without causing erosion either alone or with $Ca(OCl)_2$.