• Title/Summary/Keyword: Two Spheres

Search Result 145, Processing Time 0.024 seconds

Performance Test of the Iterative Method and Newly Developed True X Method (PET 검사에서 Iterative 재구성 방법과 True X 재구성 방법에 따른 영상의 균일성 및 대조도 비교 평가)

  • Choi, Jae-Min;NamKung, Chang-Kyeong;Park, Seung-Yong;Nam, Ki-Pyo;Lim, Ki-Cheon
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.13 no.1
    • /
    • pp.20-24
    • /
    • 2009
  • Objective: In this study, the differences between two reconstruction methods were analyzed by comparing image uniformity and contrast according to Iteration and Subset, which were altered through the Iterative method and True X method, used in Siemens' PET/CT studies. Methods: The Phantom images were obtained by exposure for two minutes per one bed. To determine the image uniformity, the Coefficient of variance was used. Also, in order to compare the contrast value, we measured and analyzed the ratio of the SUV mean of Phantom image's hot spheres and the background. Results: Under the same reconstruction conditions (Iteration and Subset) of CV, the Iterative method was higher than the True X method. In the comparison of the SUV mean ratio of the background and hot sphere, the True X method had a closer rate than the Iterative method. Conclusion: The newly developed True X reconstruction method is better than the previously used Iterative method in terms of uniformity and contrast. However, the date for this study was only obtained using the Phantom device. In order to obtain more accurate and useful information from the experiment, further research should be conducted. Also, it is necessary to find the appropriate standards for Iteration and Subset for further experimentation.

  • PDF

New horizon of geographical method (인문지리학 방법론의 새로운 지평)

  • ;Choi, Byung-Doo
    • Journal of the Korean Geographical Society
    • /
    • v.38
    • /
    • pp.15-36
    • /
    • 1988
  • In this paper, I consider the development of methods in contemporary human geography in terms of a dialectical relation of action and structure, and try to draw a new horizon of method toward which geographical research and spatial theory would develop. The positivist geography which was dominent during 1960s has been faced both with serious internal reflections and strong external criticisms in the 1970s. The internal reflections that pointed out its ignorance of spatial behavior of decision-makers and its simplication of complex spatial relations have developed behavioural geography and systems-theoretical approach. Yet this kinds of alternatives have still standed on the positivist, geography, even though they have seemed to be more real and complicate than the previous one, The external criticisms that have argued against the positivist method as phenomenalism and instrumentalism suggest some alternatives: humanistic geography which emphasizes intention and action of human subject and meaning-understanding, and structuralist geography which stresses on social structure as a totality which would produce spatial phenomena, and a theoretical formulation. Human geography today can be characterized by a strain and conflict between these methods, and hence rezuires a synthetic integration between them. Philosophy and social theory in general are in the same in which theories of action and structural analysis have been complementary or conflict with each other. Human geography has fallen into a further problematic with the introduction of a method based on so-called political ecnomy. This method has been suggested not merely as analternative to the positivist geography, but also as a theoretical foundation for critical analysis of space. The political economy of space with has analyzed the capitalist space and tried to theorize its transformation may be seen either as following humanistic(or Hegelian) Marxism, such as represented in Lefebvre's work, or as following structuralist Marxism, such as developed in Castelles's or Harvey's work. The spatial theory following humanistic Marxism has argued for a dialectic relation between 'the spatial' and 'the social', and given more attention to practicing human agents than to explaining social structures. on the contray, that based on structuralist Marxism has argued for social structures producing spatial phenomena, and focused on theorising the totality of structures, Even though these two perspectives tend more recently to be convergent in a way that structuralist-Marxist. geographers relate the domain of economic and political structures with that of action in their studies of urban culture and experience under capitalism, the political ecnomy of space needs an integrated method with which one can overcome difficulties of orthhodox Marxism. Some novel works in philosophy and social theory have been developed since the end of 1970s which have oriented towards an integrated method relating a series of concepts of action and structure, and reconstructing historical materialism. They include Giddens's theory of structuration, foucault's geneological analysis of power-knowledge, and Habermas's theory of communicative action. Ther are, of course, some fundamental differences between these works. Giddens develops a theory which relates explicitly the domain of action and that of structure in terms of what he calls the 'duality of structure', and wants to bring time-space relations into the core of social theory. Foucault writes a history in which strategically intentional but nonsubjective power relations have emerged and operated by virtue of multiple forms of constrainst wihthin specific spaces, while refusing to elaborate any theory which would underlie a political rationalization. Habermas analyzes how the Western rationalization of ecnomic and political systems has colonized the lifeworld in which we communicate each other, and wants to formulate a new normative foundation for critical theory of society which highlights communicatie reason (without any consideration of spatial concepts). On the basis of the above consideration, this paper draws a new norizon of method in human geography and spatial theory, some essential ideas of which can be summarized as follows: (1) the concept of space especially in terms of its relation to sociery. Space is not an ontological entity whch is independent of society and has its own laws of constitution and transformation, but it can be produced and reproduced only by virtue of its relation to society. Yet space is not merlely a material product of society, but also a place and medium in and through which socety can be maintained or transformed.(2) the constitution of space in terms of the relation between action and structure. Spatial actors who are always knowledgeable under conditions of socio-spatial structure produce and reproduce their context of action, that is, structure; and spatial structures as results of human action enable as well as constrain it. Spatial actions can be distinguished between instrumental-strategicaction oriented to success and communicative action oriented to understanding, which (re)produce respectively two different spheres of spatial structure in different ways: the material structure of economic and political systems-space in an unknowledged and unitended way, and the symbolic structure of social and cultural life-space in an acknowledged and intended way. (3) the capitalist space in terms of its rationalization. The ideal development of space would balance the rationalizations of system space and life-space in a way that system space providers material conditions for the maintainance of the life-space, and the life-space for its further development. But the development of capitalist space in reality is paradoxical and hence crisis-ridden. The economic and poltical system-space, propelled with the steering media like money, and power, has outstriped the significance of communicative action, and colonized the life-space. That is, we no longer live in a space mediated communicative action, but one created for and by money and power. But no matter how seriously our everyday life-space has been monetalrized and bureaucratised, here lies nevertheless the practical potential which would rehabilitate the meaning of space, the meaning of our life on the Earth.

  • PDF

A Comparative Analysis According to a Presence or Absence of Metal Artifacts when a Dose Change and QAC Technique are Applied in PET/CT Tests (PET/CT 검사에서 선량변화와 QAC기법 적용 시 Metal Artifact 유무에 따른 SUV 비교분석)

  • Yun, Sun-Hee;Kim, Yang-Jung;Kang, Young-Jik;Park, Su-Young;Kim, Ho-Sin;Ryu, Hyoung-Ki
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.19 no.1
    • /
    • pp.51-56
    • /
    • 2015
  • Purpose As medical radiation exposures on patients are being social issues an interest in a relief of radiation exposures on patients is increasing. Further, there are many cases where some patients among who are getting PET/CT tests choose to get implanted with metal artifacts in their bodies. This study is to find out effects of presence or absence of metal artifacts when dose change or CT attenuation correction for the relief of radiation exposures are applied using phantoms through changes in standard uptake value (SUV). Materials and Methods GE company's Discovery 710 machine was used for PET/CT test equipments. We used NEMA IEC body phantoms. We also used screw and mesh cage made of titanium which are used in real clinical processes for the metal artifacts. Two experiments were conducted: One is to test and measure repeatedly about SUV about differences in CT attenuation corrections according to dose changes and another is to do the same procedure for SUV about the presence and absence of the metal artifacts. We injected $^{18}F-FDG$ into NEMA IEC body phantoms with a TBR ratio of 4:1 and then put the metal material into the transformation phantoms. Once a scanning for the metal artifacts was done we eliminated the metal artifacts and went on non-metal artifacts. For the each two experiments, we scanned repeatedly with CT kVp (140, 120, 100, 80) and mA (120, 80, 40, 20, 10) for an experimental condition. For PET, we reconstructed each with standard AC (STD) technique and quantitation achieved cnsistently QAC) technique among CT attenuation correction methods. We conducted a comparative analysis on measured average values and variations which were measured through repeated measure of SUV of region 1, 2, 3 spheres for each conditions of non-metal /metal scan. Results For each kVp, 120, 80, 40 (mA) of non/metal (screw, mesh cage) showed low frequency of fluctuation rates of above 2%. In 20, 10 mA above 2% of fluctuation rates appeared in high frequency. Also, when we compared the fluctuation rates of STD and QAC techniques in non/metal (screw, mesh cage) tests QAC technique showed about 1-10% of differences for each conditions compared to STD technique. In addition, metal types did not have significant effects on fluctuation rates. Conclusion We confirmed that SUV fluctuation rates for both STD and QAC techniques increase as dosage is lower. We also found that the SUV of PET data was maintained steadily in a low dosage for QAC technique when compared with STD technique. Hence, when the low dosage is used for the relief of radiation exposures on patients QAC technique may be exploited helpfully and this could be applied in the same way for patients with metal artifacts implanted in their bodies.

  • PDF

Electrochemical Characteristics of LiMn2O4 Cathodes Synthesized from Various Precursors of Manganese Oxide and Manganese Hydroxide (다양한 형태 및 구조의 망간산화물 및 망간수산화물 전구체로부터 합성한 LiMn2O4양극의 전기화학적 특성 연구)

  • Lee, Jong-Moon;Kim, Joo-Seong;Hong, Soon-Kie;Lee, Jeong-Jin;Ahn, Han-Cheol;Cho, Won-Il;Mho, Sun-Il
    • Journal of the Korean Electrochemical Society
    • /
    • v.15 no.3
    • /
    • pp.172-180
    • /
    • 2012
  • The $LiMn_2O_4$ cathodes for lithium ion battery were synthesized from various precursors of manganese oxides and manganese hydroxides. As the first step, nanosized precursors such as ${\alpha}-MnO_2$ (nano-sticks), ${\beta}-MnO_2$ (nano-rods), $Mn_3O_4$ (nano-octahedra), amorphous $MnO_2$(nano-spheres), and $Mn(OH)_2$ (nano-plates) were prepared by a hydrothermal or a precipitation method. Spinel $LiMn_2O_4$ with various sizes and shapes were finally synthesized by a solid-state reaction method from the manganese precursors and LiOH. Nano-sized (500 nm) octahedron $LiMn_2O_4$ showed high capacities of 107 mAh $g^{-1}$ and 99 mAh $g^{-1}$ at 1 C- and 50 C-rate, respectively. Three dimensional octahedral crystallites exhibit superior electrochemical characteristics to the other one-dimensional and two-dimensional shaped $LiMn_2O_4$ nanoparticles. After 500 consecutive charge discharge battery cycles at 10 C-rate with the nano-octahedron $LiMn_2O_4$ cathode, the capacity retention of 95% was observed, which is far better than any other morphologies studied in this work.

The Correction Effect of Motion Artifacts in PET/CT Image using System (PET/CT 검사 시 움직임 보정 기법의 유용성 평가)

  • Yeong-Hak Jo;Se-Jong Yoo;Seok-Hwan Bae;Jong-Ryul Seon;Seong-Ho Kim;Won-Jeong Lee
    • Journal of the Korean Society of Radiology
    • /
    • v.18 no.1
    • /
    • pp.45-52
    • /
    • 2024
  • In this study, an AI-based algorithm was developed to prevent image quality deterioration and reading errors due to patient movement in PET/CT examinations that use radioisotopes in medical institutions to test cancer and other diseases. Using the Mothion Free software developed using, we checked the degree of correction of movement due to breathing, evaluated its usefulness, and conducted a study for clinical application. The experimental method was to use an RPM Phantom to inject the radioisotope 18F-FDG into a vacuum vial and a sphere of a NEMA IEC body Phantom of different sizes, and to produce images by directing the movement of the radioisotope into a moving lesion during respiration. The vacuum vial had different degrees of movement at different positions, and the spheres of the NEMA IEC body Phantom of different sizes produced different sizes of lesions. Through the acquired images, the lesion volume, maximum SUV, and average SUV were each measured to quantitatively evaluate the degree of motion correction by Motion Free. The average SUV of vacuum vial A, with a large degree of movement, was reduced by 23.36 %, and the error rate of vacuum vial B, with a small degree of movement, was reduced by 29.3 %. The average SUV error rate at the sphere 37mm and 22mm of the NEMA IEC body Phantom was reduced by 29.3 % and 26.51 %, respectively. The average error rate of the four measurements from which the error rate was calculated decreased by 30.03 %, indicating a more accurate average SUV value. In this study, only two-dimensional movements could be produced, so in order to obtain more accurate data, a Phantom that can embody the actual breathing movement of the human body was used, and if the diversity of the range of movement was configured, a more accurate evaluation of usability could be made.