• Title/Summary/Keyword: Twin-Fluid Atomization

Search Result 51, Processing Time 0.036 seconds

An Experimental Study on the Break-up Characteristics of Twin-Fluid Nozze According to tile Variations of Feeding Mass-ratio (공급 질량비 변화에 따른 2유체 노즐의 액주분열특성에 관한 실험적 연구)

  • Kang, S.J.;Oh, J.H.;Rho, B.J.
    • Journal of ILASS-Korea
    • /
    • v.1 no.1
    • /
    • pp.63-75
    • /
    • 1996
  • The purpose of this study is to investigate the break-up characteristics by taking advantage of a two-phase coaxial nozzle. Air and water are utilized as working fluids and the mass ratio air/water has been controlled to characterize the atomization, diffusion and development of mixing process. By way of a photographic technique, conventional developing structures and diffusion angles have been analyzed systematically with variations of mass ratios. The turbulent flow components of the atomized particles were measured by a two channel LDV system and the data were treated by an on-lined measurement equipment. According to the photographic results the spreading angles decreased because the axial inertia moment was relatively higher than the lateral one with respect to the increase of mass ratio. It is found the jet flow diffuses linearly in a certain limit region while the atomizing characteristics, in terms of the distributions of particle diameters did not show particular differences. It may be expected that these fundamental results can be used as reference data in studying the atomization, breakup and diffusions.

  • PDF

Atomization Characteristics of shear coaxial twin fluid injector (동축형 인젝터의 미립화 특성)

  • Han, J.S.;Kang, G.T.;Kim, Y.;Kim, S.J.
    • Journal of ILASS-Korea
    • /
    • v.5 no.4
    • /
    • pp.40-46
    • /
    • 2000
  • To understand the basic the structure of the spray field and to obtain the initial conditions for computational models for shear coaxial twin-fluid injectors. the atomization characteristics under different flow and geometric conditions were examined. The spray characteristics such as SMD, mean axial and radial velocities, Dia. of droplets and volume flux with a P.D.P.A. Water and nitrogen gas under atmospheric conditions were used as a test fluids. The drops produced by shear coaxial injectors continue to disintegrate along the spray axis and decrease their sizes. SMD was the maximum at the spray center of spray and decreased with increasing radial distance. The results of this parametric study showed that SMD decreased with increasing gas injection velocity as well as with decreasing liquid injection mass flow rate, The relative velocity between gas and liquid flow played a significant role resulted in decreasing SMD and in spreading the spray. Recessing the liquid orifice resulted decreasing SMD and a spreading the spray. Recess of liquid orifice by 5.0mm showed best atomization characteristics in this experiment. Although drop diameter changes, shear coaxial injector sprays had constant velocity and exhibited a high degree of radial symmetry.

  • PDF

Spray characteristics on mixing region scale of twin fluid atomizer (이류체 분사노즐의 혼합영역 형상에 따른 분무특성)

  • 김병문;김혁주;이충원
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.15 no.6
    • /
    • pp.2147-2159
    • /
    • 1991
  • The effects of principal dimensions of internal mixing twin-fluid atomized and operating conditions on the atomizing characteristics are experimentally investigated. The tests are conducted over the wide range of air/liquid ratio to predict influences of the diameter and length of nozzle, contacting angle between air and liquid in the mixing chamber, and air orifice diameter on the mean drop size(SMD), spray angle, distribution of drop size, and spray dispersion, And also, initial distribution of liquid column by air stream within the mixing chamber are observed through the transparent nozzles. A He-Ne laser particle sizer(MALVERN Model 2604) was used to measure the Sauter.s mean diameter( $D_{321}$) and droplet sizes distribution. In this experiment the air/liquid ratio, mixing length and nozzle diameter have a great influence on SMD, spray angle, droplet sizes distribution and spray dispersion.

Atomization Characteristics of Effervescent Twin-fluid Nozzle with Different Nozzle Shapes (노즐 형상에 따른 Effervescent 이유체 노즐의 분무특성)

  • Lee, Sang Ji;Hong, Jung Goo
    • Journal of ILASS-Korea
    • /
    • v.22 no.3
    • /
    • pp.146-152
    • /
    • 2017
  • An experimental study was carried out to investigate the spray characteristics of non-circular effervescent twin-fluid nozzles. For this purpose, two types of non-circular nozzles (E1, E2) and circular nozzle (C) were used. Three types of aerorators with hole diameters of 1.2, 1.7 and 2.1 mm were used. Each aerorator has a total of 12 holes. It is defined by area ratio which is ratio of exit orifice area and aerator hole area. Experiments were carried out by controlling the amount of air flowing after fixing the flow rate of the liquid, and the nozzle internal pressure and SMD were measured, and the jet image was taken from the nozzles. The discharge coefficients of the three kinds of nozzles were compared with the used in plain orifice's equation and the Jedelsky's equation, and the Jedelsky's equation was found to be about 3 times larger. In addition, empirical formula based on ALR, which is the largest variable in Jedelsky's equation, was derived. The droplet sizes(SMD) were found to be smaller in the non-circular shape than in the circular shape, which is concluded to be caused by the difference of the discharge coefficients.

Improvement of the Efficiency of a Twin-fluid Nozzle using Ultrasonic Vibration (초음파 가진을 이용한 2-유체 노즐의 효율 향상)

  • 주은선;나우정;정진도;송민근;이경열
    • Journal of Biosystems Engineering
    • /
    • v.27 no.4
    • /
    • pp.317-326
    • /
    • 2002
  • Characteristics of a twin-fluid spray with ultrasonic vibration were examined in order to obtain a high efficiency of cold-fog spray of the automatic pest control machine which has been widely used in protected horticulture recently. An electrostrictive vibrator of PZT BLT and a magnetostrictive $\pi$-type vibrator were used applied as the ultrasonic transducers with a frequency of 28 kHz. All experiments were conducted in 4 methods of spray ; a conventional spray method without ultrasonic forcing, an indirect vibration method with ultrasonic forcing, an improving-quality method by ultrasonic forced within liquid, and a combined-use method with both of the indirect vibration method and the improving quality method. It was found that the ultrasonic energy increased the atomization efficiency of spray droplets about 10% and especially much more in the case of the combined-use method.

Behavior Characteristics of Swirl-Twin Spray with Changing Swirl Angle (선회각도변화에 따른 2유체 선회분무의 거동특성)

  • Kang, Wan-Bong;Cha, Keun-Jong;Kim, Duck-Jool
    • Proceedings of the KSME Conference
    • /
    • 2000.04b
    • /
    • pp.943-948
    • /
    • 2000
  • The Twin-fluid Swirl Nozzles are used in many parts of the industry to produce homogeneous spray. This study is to investigate the effects of outer air swiller and inner water swiller on atomization of liquid.. The experiment was carried out with increasing air-flow rate at constant liquid-flow rate and with changing outer air swiller angle and inner water swiller angle. A Particle Dynamics Analyzer(PDA) was used to measure drop size, mean and ms values of axial velocity, number density and Sauter mean diameter(SMD). The axial mean velocity and SMD of droplets were measured along the center line and radial directions. It was found that the higher air flow-rate resulted in the smaller Sauter mean diameter of liquid spray and the higher axial mean velocity of droplets. This experimental results will be conveniently used for the preliminary design stage of twin-fluid nozzle development.

  • PDF

Atomizing Mechanism for a Mist Blower (동력살분무기의 무화기구에 관한 연구)

  • 이상우
    • Journal of Biosystems Engineering
    • /
    • v.21 no.2
    • /
    • pp.117-122
    • /
    • 1996
  • Droplet sizes produced from a mist blower should be adequate to get highly biological effects with a reasonable level of work performance. However the droplet sizes from the conventional nozzles of the mist blower were around VMD 95 to 469$\mu$ which were relatively large as compared with the recommended droplet sizes in liquid flow rate of 17.2 m$/ell$s with air flow rate of 16660$m^3$/s on the maximum travel distance of about 4.0 m. The velocity of air stream at the point where two fluids, air and liquid, impact each other, was tried to maximize as much as possible in order to enhance the atomization performance of a newly designed twin fluid nozzles with the same or better level of performance of the conventional mist blower, The configuration of nozzle orifice should be designed to enlarge the contact area between air and liquid to enhance the atomization.

  • PDF

Study on the Structures of the Nozzle for the Spray (분무기용(噴霧機用) Nozzle의 구조(構造)에 관한 연구(硏究))

  • Lee, S.W.
    • Journal of Biosystems Engineering
    • /
    • v.18 no.2
    • /
    • pp.100-109
    • /
    • 1993
  • The aim of this study was to provide the reasonable data for design of the nozzle which produces finer droplets on the same level of the effective travel distance or which transports droplets to the farther target on the reasonable atomization in comparison with the commercial nozzles being used much in Korean rural areas. Newly designed twin-fluid atomizers with some commercial nozzles were tested in this study, and their results were as follows : 1. The characteristics of the spray deposit distribution of No.1 nozzles for farther target were nearly same in the near or nearer travel distance less than 8m. Therefore it was reasonable to combine the characteristics of the spray deposit distributions of No.2 and No.3 nozzles to those of No.1 nozzle. 2. The effective travel distance was increased with increase of the sectional area of the jet ligament, and the maximum effective travel distance was reached to about 17m. 3. The droplet size was increased with increase of the sectional area of the jet ligament, and the maximum droplet size was produced in the front of the point of the maximum spray deposit distribution. 4. The atomization was excellent in the twin-fluid atomizer in comparison with the hydraulic atomizer and also the effective travel distances were nearly same level in both atomizers.

  • PDF

A Study on the Spray Characteristics of the Cold-Fog Spray with Ultrasonic Forcing (초음파적용 상온연무기의 분무특성에 관한 연구)

  • Song Min-Geun;Lee Kyung-Youl;Son Sung-Woo;La Woo-Jung;Ju Eun-Sun
    • Proceedings of the KSME Conference
    • /
    • 2002.08a
    • /
    • pp.299-302
    • /
    • 2002
  • Characteristics of the twin fluid spray with ultrasonic forcing are examined in order to obtain the high efficiency of cold fog spray of the automatic pest control machine which has been widely used for the equipment cultivation recently. An electrostrictive vibrator of PZT BLT and a magnetostrictive vibrator of ${\pi}type$ with 28 kHz are applied as the ultrasonic transducer. All experiments are made and observed in 4 methods of spray ; a conventional spray method without ultrasonic forcing, an indirect vibration method with ultrasonic forcing, an improving duality method by ultrasonic forced within liquid, and a combined use method with both of the indirect vibration method and the improving quality method. In results, It was clarified that the ultrasonic effects the atomization of spray droplets and its efficiency is about $10{\%}$ and especially much more in the case of the combined use method.

  • PDF

Spray characteristics of effervescent atomizer with internal flows (Effervescent atomizer의 내부 유동에 따른 분무특성)

  • Ku, K.W.;Hong, J.G.;Kim, J.H.;Lee, C.W.;Park, C.D.;Lim, B.J.;Chung, K.Y.
    • Proceedings of the Korean Society of Marine Engineers Conference
    • /
    • 2012.06a
    • /
    • pp.123-124
    • /
    • 2012
  • Effervescent atomizer in which the liquid is ejected from nozzle with bubble caused by gas injection into the liquid is one of twin-fluid atomizers. Effervescent atomizer is operated with the lower injection pressure and the smaller air flow rate when compared with those of other twin-fluid atomizers. In this study, we attempted experiment study to investigate the atomization characteristics of effervescent atomizer related with the internal flow condition. The nozzle was made with acrylic material to investigate the nozzle internal flow. The macroscopic spray analysis was conducted with internal flow images and spray images. Furthermore, SMD was measured by using the laser diffraction method. According to this study, the internal flow condition changed from bubbly flow to annular flow as the air-liquid mass ratio(ALR) increases. At that time, the atomization characteristics were improved.

  • PDF