• Title/Summary/Keyword: Turn to Turn Defect

Search Result 46, Processing Time 0.024 seconds

Computer Vision-based Automated Adhesive Quality Inspection Model of Exterior Insulation and Finishing System (컴퓨터 비전 기반 외단열 공사의 접착제 도포품질 감리 자동화 모델)

  • Yoon, Sebeen;Kang, Mingyun;Jang, Hyounseung;Kim, Taehoon
    • Journal of the Korea Institute of Building Construction
    • /
    • v.23 no.2
    • /
    • pp.165-173
    • /
    • 2023
  • This research proposed a model for automatically monitoring the quality of insulation adhesive application in external insulation construction. Upon case implementation, the area segmentation model demonstrated a 92.3% accuracy, while the area and distance calculation accuracies of the proposed model were 98.8% and 96.7%, respectively. These findings suggest that the model can effectively prevent the most common insulation defect, insulation failure, while simultaneously minimizing the need for on-site supervisory personnel during external insulation construction. This, in turn, contributes to the enhancement of the external insulation system. Moving forward, we plan to gather construction images of various external insulation methods to refine the image segmentation model's performance and develop a model capable of automatically monitoring scenarios with a considerable number of insulation materials in the image.

I-V and C-V measurements or fabricated P+/N junction mode in Antimony doped (111) Silicon

  • Jung, Won-Chae
    • Transactions on Electrical and Electronic Materials
    • /
    • v.3 no.2
    • /
    • pp.10-15
    • /
    • 2002
  • In this paper, the electrical characteristics of fabricated p+-n junction diode are demonstrated and interpreted with different theoretical calculations. Dopants distribution by boron ion implantation on silicon wafer were simulated with TRIM-code and ICECaEM simulator. In order to make electrical activation of implanted carriers, thermal annealing treatments are carried out by RTP method for 1min. at $1000^{circ}C$ under inert $N_2$ gas condition. In this case, profiles of dopants distribution before and after heat treatments in the substrate are observed from computer simulations. In the I-V characteristics of fabricated diodes, an analytical description method of a new triangular junction model is demonstrated and the results with calculated triangular junction are compared with measured data and theoretical calculated results of abrupt junction. Forward voltage drop with new triangular junction model is lower than the case of abrupt junction model. In the C-V characteristics of diode, the calculated data are compared with the measured data. Another I-V characteristics of diodes are measured after proton implantation in electrical isolation method instead of conventional etching method. From the measured data, the turn-on characteristics after proton implantation is more improved than before proton implantation. Also the C-V characteristics of diode are compared with the measured data before proton implantation. From the results of measured data, reasonable deviations are showed. But the C-V characteristics of diode after proton implantation are deviated greatly from the calculated data because of leakage currents in defect regions and layer shift of depletion by proton implantation.

Ultraviolet LEDs using n-ZnO:Ga/i-ZnO/p-GaN:Mg heterojunction (n-ZnO/i-ZnO/p-GaN:Mg 이종접합을 이용한 UV 발광 다이오드)

  • Han, W.S.;Kim, Y.Y.;Kong, B.H.;Cho, H.K.;Lee, J.H.;Kim, H.S.
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2008.11a
    • /
    • pp.50-50
    • /
    • 2008
  • ZnO has been extensively studied for optoelectronic applications such as blue and ultraviolet (UV) light emitters and detectors, because it has a wide band gap (3.37 eV) anda large exciton binding energy of ~60 meV over GaN (~26 meV). However, the fabrication of the light emitting devices using ZnO homojunctions is suffered from the lack of reproducibility of the p-type ZnO with high hall concentration and mobility. Thus, the ZnO-based p-n heterojunction light emitting diode (LED) using p-Si and p-GaN would be expected to exhibit stable device performance compared to the homojunction LED. The n-ZnO/p-GaN heterostructure is a good candidate for ZnO-based heterojunction LEDs because of their similar physical properties and the reproducibleavailability of p-type GaN. Especially, the reduced lattice mismatch (~1.8 %) and similar crystal structure result in the advantage of acquiring high performance LED devices with low defect density. However, the electroluminescence (EL) of the device using n-ZnO/p-GaN heterojunctions shows the blue and greenish emissions, which are attributed to the emission from the p-GaN and deep-level defects. In this work, the n-ZnO:Ga/p-GaN:Mg heterojunction light emitting diodes (LEDs) were fabricated at different growth temperatures and carrier concentrations in the n-type region. The effects of the growth temperature and carrier concentration on the electrical and emission properties were investigated. The I-V and the EL results showed that the device performance of the heterostructure LEDs, such as turn-on voltage and true ultraviolet emission, developed through the insertion of a thin intrinsic layer between n-ZnO:Ga and p-GaN:Mg. This observation was attributed to a lowering of the energy barriers for the supply of electrons and holes into intrinsic ZnO, and recombination in the intrinsic ZnO with the absence of deep level emission.

  • PDF

Ultrasonographic Evaluation of the Thyroid Glands, Jugular Vein and Carotid Artery in Horse (말에서 갑상선, 경정맥 및 경동맥의 초음파상)

  • 김명철;김용준;변홍섭;신상태;이경광;한용만;김병선
    • Korean Journal of Animal Reproduction
    • /
    • v.22 no.1
    • /
    • pp.67-72
    • /
    • 1998
  • Nowadays many kinds of foreign breed horse and Korean native Cheju horse are raised in Korea. Horse has complicated structure and function to maintain normal health, and to overcome severe condition during gallop at full speed. Sometimes the disease take a bad turn becuase of difficulty of correct diagnosis for horse disease. In recent times, horse farm for fattening and reproduction is gradually increasing. However, thoracic disease and abdominal disease are frequently occuring by defect in raising management. But the diagnosis of these kinds of disease is difficult by former diagnostic method. Ultrasonographic diagnostic method is a method to slove the problem. In abroad, nowadays ultrasonography has been reported for circulatory organs and abdomonal organs in horse, cattle, sheep, and dog, and the importance of ultrasonographic diagnosis is recognized in veterinary clinical medicine. In the country, ultrasonography of Korean native goat, cattle and dog was recently reported, but there was no report for the ultrasonography of horse. So, ultrasonogram for the thyroid glands, jugular vein and carotid artery was evaluated in Cheju horse and Thoroughbred horse. Thyroid gland, jugular vein and carotid artery were determined on both sides of neck. The length of right thyroid lobe at the Thoroughbred horse, Thoroughbred foul, Cheju horse and Cheju foul were 54.8, 45.1, 46.1 and 42.2 mm, respectively. The width of right thyroid lobe at the Thoroughbred horse, Thoroughbred foul, Cheju horse and Cheju foul were 18.1, 14.3, 14.6 and 14.2 mm, respectively. The height of right thyroid lobe at the Thoroughbred horse, Thoroughbred foul, Cheju horse and Cheju foul were 27.3, 25.6, 26.2 and 25.5 mm, respectively. Similar ultrasonographic measurements were obtained for the left thyroid gland. The internal diameter of left jugular vein at the Thoroughbred horse, Thoroughbred foul, Cheju horse and Cheju foul were 10.6, 9.7, 10.5 and 9.2 mm, respectively. Similar ultrasonographic measurements were obtained for the right jugular vein. The internal diameter of right carotid artery at the Thoroughbred horse, Thoroughbred foul, Cheju horse and Cheju foul were 9.5, 8.8, 9.1 and 8.5 mm, respectively. Similar ultrasonographic measurements were obtained for the left carotid artery. It is concluded that the ultrasonographic values of this study provides references for the diagnosis of morphologic changes in the thyroid gland, jugular vein and carotid artery in Korean native Cheju horse and Thoroughbred horse.

  • PDF

Changes in midpalatal suture area and adjacent periodontal tissues of individual tooth following rapid palatal expansion in young adult dogs ; Histomorphologic and immunohistochemical study (유성견 급속 구개확장시 정중구개봉합부 및 치아주위 조직 변화에 관한 조직형태학적 및 면역조직화학적 연구)

  • Lee, Ju-Young;Lee, Jin-Woo;Cha, Kyung-Suk
    • The korean journal of orthodontics
    • /
    • v.30 no.3 s.80
    • /
    • pp.317-333
    • /
    • 2000
  • The purpose of this study was to determine the proliferative activity of the osteoblasts and fibroblasts in the midpalatal area and to investigate the adjacent periodontal tissues of individual tooth following rapid expansion of the palate. Ten young adult dogs, aged approximately ten months, were used in the experiment. The experimental design was consisted of 1 week expansion group(Group E1, 3 dogs), 2 week expansion group(Group E2, 3 dogs), 2 week expansion and 2 week retention group(Group E3, 3 dogs), and control group(Group C, 1 dog). For each group, expansion screw was activated one time per day(1/4 turn;$90^{\circ}$) following Hyrax-screw application. The experimental animals in each group were sacrificed at 1, 2 and 4 weeks following palatal expansion. Maxillary tissue blocks were obtained and prepared ior the histomorphologic and immunohistochemical studies. Light mcroscope, polarizing microscope, and soft X-ray apparatus were used in this study, and following results were obtained. 1. In polarizing microscopic study, the expansion groups(E1 & E2) showed blue color representing bone resorption and new bone formation in midpalatal suture area. E3 groups skewed less blue color compared to the E1 and E2 group. But yellow color increased by calcification in the E3 groups. 2. Immunohistochemical study revealed that positive responses of the osteoblasts to PCNA and undifferentiated fibroblasts to EGF in E1 group were somewhat increased. Positive response to PCNA and EGF were increased in fibroblasts and the osteoblasts forming new bone in E2 group. In E3 group, the positive response cell concentrated the periphery of edge of palatal process in both PCNA and EGF. 3. Throughout the expansion period(E1 & E2), light microscopic study showed the edges of the extensive resorption and new palatal processes, indicating bone remodeling within the suture. E3 group exhibited less remodeling of midpalatal suture area. E2 group and E3 group showed cementum formation and resorption at the apex of 3rd premolar and 1st molar E3 group exhibited extensive hyalinized zone on the cervical portion of buccal side of 1st molar. 4. Soft X-ray analysis of E1 group showed hypomineralized defect and microfractures in various parts of the suture areas when compared with control animals. There was no significant difference in the degree of mineralization in the midpalatal suture region between the C and E3 groups. Tooth axis showed tipping of 3rd premolar and 1st molar in the E2 group and E3 group. Based upon these experimental results, it is concluded that the undifferentiated mesenchymal cells always presented in midpalatal suture area following RPE. Differentiated osteoblasts and fibroblasts possess proliferating cellular activity until the 2 week retention period. The posterior teeth are tend to tip buccally as RPE force applied. Retention group exhibited irreversible response with severe hyalinized zone on the buccal surface of the first molar.

  • PDF

Evaluation of Prognostic Factors in Corrected Transposition of the Great Arteries at Mid-term Follow-up (수정 대혈관 전위 환자에서 예후에 영향을 주는 인자들에 대한 중기적 고찰)

  • Song, Young-Hwan;Kwon, Hyok-Joo;Kim, Gi-Beom;Kang, Soo-Jung;Bae, Eun-Jung;Noh, Chung-Il;Yun, Yong-Soo;Lee, Jeong-Ryul;Kim, Yong-Jin;Rho, Joon-Ryang
    • Clinical and Experimental Pediatrics
    • /
    • v.46 no.2
    • /
    • pp.154-161
    • /
    • 2003
  • Purpose : The prognosis of patients with corrected transposition of the great arteries(C-TGA) is variably affected by associated intracardiac defects, systemic right ventricular function, tricuspid valve competence, and conduction disturbances. This study aims to evaluate the importance of those factors at mid-term follow-up. Methods : Medical records of 94 patients(males 58, females 36; mean age at last follow-up, $12{\pm}9$ years; mean follow-up duration, $9{\pm}6.4$ years) diagnosed between January 1980 and May 2002 at Seoul National University Children's Hospital were studied retrospectively. Results : Among 94 patients, operations were performed in 72 patients(classic operations in 55; double switch operations in 17). Among prognostic factors including associated intracardiac anomalies(at least moderately severe tricuspid insufficiency(TI), ventricular septal defect, pulmonary stenosis and pulmonary atresia), intracardiac operation and complete atrioventricular block, TI was the only significant factor for death(P=0.001), and in turn, Ebstein anomaly and high grade atrioventricular block predicted TI. 20-year survival without TI was 77%, but only 35% with TI(P=0.0002); excluding perioperative death, the 20-year survival rates with and without TI were 48% and 87% respectively(P=0.008). There was no statistical difference in 20-year survival rate or association with TI between classic and double switch operation. Conclusion : TI was the major prognostic factor for C-TGA and was associated with Ebstein anomaly and high grade atrioventricular block at mid-term follow-up. Long-term follow-up is required to evaluate other factors, including double switch operations and associated intracardiac defects more exactly.