• Title/Summary/Keyword: Turbopump(터보펌프)

Search Result 265, Processing Time 0.027 seconds

Analysis of Transient Characteristics for Turbopump-fed Liquid Propellant Rocekt Engine in Start-up (터보펌프식 액체 로켓 엔진의 시동 과도 특성 해석)

  • Son, Min;Kim, Duk-Hyun;Koo, Ja-Ye
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2010.05a
    • /
    • pp.34-37
    • /
    • 2010
  • One dimensional transient analysis was studied for turbopump-fed liquid propellant rocket engine(LRE) system in starting using AMESim. The effects of timing of gas generator fuel valve opening and gas generator ignition to start-up stability were researched for open cycle type system using LOX/RP-1 to propellants. Result show that the parameters and sequence on start-up should be considered to design optimized turbopump-fed LRE system.

  • PDF

Performance Test of the 30-ton Class Liquid Rocket Engine Turbopump Turbine (30톤급 액체로켓 엔진용 터보펌프 터빈 성능시험)

  • Jeong, Eun-Hwan;Park, Pyun-Goo;Kim, Jin-Han
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.12 no.1
    • /
    • pp.1-6
    • /
    • 2008
  • Performance test of the 30-ton class liquid rocket engine turbopump turbine has been conducted using high pressure cold air. Overall performance of the two kinds of turbine rotors - rotor with knife-edged L.E blades and with rounded L.E blades - has been measured for various rotational speed and turbine pressure ratio. The effect of rotational speed and turbine pressure ratio on the turbine axial force behavior also has been measured in parallel. Test results have revealed that the efficiency of knife edged L.E. turbine is a little bit higher than that of rounded L.E. turbine. The axial force of the turbine varied linearly with respect to rotational speed and its magnitude largely depended on turbine pressure ratio.

Experimental Investigation of Turbopump Turbine : Turbine Performance and Effect of Nozzle-Rotor Clearance (터보펌프 터빈의 성능 및 노즐-로터 간극의 영향에 대한 실험적 고찰)

  • Jeong Eun-Hwan;Kang Sang-Hun;Shin Dong-Yoon;Park Pyu-Goo;Kim Jin-Han
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.10 no.2
    • /
    • pp.78-86
    • /
    • 2006
  • This paper presents the performance test result of the 30-ton class turbopump turbine. Test has been conducted using high pressure cold air, The turbine overall performance has been measured for various pressure ratio and rotational speed settings. The nozzle-rotor clearance effect on turbine performance also has been tested for the four kinds of the nozzle-rotor clearance values. We found that turbine efficiency rated 51.1% at its design velocity ratio and pressure ratio of 13.5. We also found that turbine efficiency can be increased by 3.5% for approximately 1mm decrement of the nozzle-rotor clearance from its nominal value.

Measurement of Reynolds Number Effects on Cavitation Performance in a Turbopump Inducer (레이놀즈 수가 터보펌프 인듀서 캐비테이션 성능에 미치는 영향 측정)

  • Kim, Junho;Song, Seung Jin
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2017.05a
    • /
    • pp.820-823
    • /
    • 2017
  • This study experimentally investigate how the Reynolds number affect cavitation performance in a turbopump inducer using water. Cavitation performance has been determined by the static pressure measured at the inlet of the inducer. Reynolds number has been varied by varying water temperature and inducer rotational speed to maintain constant non-dimensional thermal parameter. At low non-dimensional thermal parameter, the critical cavitation number is insensitive to Reynolds number. However, at high non-dimensional thermal parameter, the critical cavitation number increased as Reynolds number increases. Thus, cavitation performance is deteriorated as Reynolds number increases when thermal effect exists.

  • PDF

Numerical Simulation of Suction Performance of a Forward-Sweep Inducer for Turbopumps (터보펌프용 전진익형 인듀서 흡입성능 유동해석)

  • Choi, Chang-Ho;Noh, Jun-Gu;Kim, Jinhan
    • The KSFM Journal of Fluid Machinery
    • /
    • v.17 no.3
    • /
    • pp.13-18
    • /
    • 2014
  • Computational and experimental studies on a forward-sweep inducer for turbopumps were performed to see the effect of the blade sweep on the suction performance of the inducer. Computational results show that backflows at the inlet decrease in the case of the forward-sweep inducer by inhibiting pre-rotation of the inflow and the low pressure region near the tip also diminishes, which is presumed to improve the suction performance of the inducer. The predicted suction performance of the inducer is compared with the experimental result. The result shows that the computation overestimates the suction performance of the inducer compared to the value from the experiment.

Cryogenic Bearing and Seal Test Facility for a Turbopump (터보펌프용 극저을 베어링/실 성능시험설비)

  • Kwak, Hyun-D.;Jeon, Seong-Min;Kim, Jin-Han
    • 유체기계공업학회:학술대회논문집
    • /
    • 2005.12a
    • /
    • pp.341-347
    • /
    • 2005
  • To perform a cryogenic development test for Tribo-elements in a turbopump, a cryogenic bearing and seal test facility (BSTF) is designed and currently under construction in KARI. The working fluid is liquid nitrogen operating at a temperature $-197^{\circ}C$. The maximum operating pressure and volume flow rate of BSTF are 100 bar and 10 liters per second, respectively. The development tests of floating ring seals, inter-propellant seals (IPS) and cryogenic ball bearings in a turbopump will be performed using the BSTF. This paper briefly described design requirements and procedures of BSTF.

  • PDF

A Study on the Flow Characteristics of a Turbopump Inducer (터보펌프 인듀서의 유동특성에 관한 연구)

  • Koo, Hyun-Chul;Hong, Soon-Sam;Cha, Bong-Jun;Yang, Soo-Seok
    • 유체기계공업학회:학술대회논문집
    • /
    • 2002.12a
    • /
    • pp.41-46
    • /
    • 2002
  • Flow field downstream of an inducer was measured to see the flow and performance characteristics of a turbopump inducer. A large axisymmetric collector instead of a volute casing was installed to obtain circumferentially uniform flow - without interaction of the inducer and the volute. A conventional 3-hole probe was used to measure the flow. At inducer exit axial component of absolute velocity decreased on hub region with decrease in flow rate. Tangential velocity component static pressure, and total pressure increased from hub to tip. Relative flow angle from tangential direction was a little higher than outlet blade angle at flow coefficient $\varphi$=0.087 and 0.073. Dynamic pressure was $53\%$ of the mean total pressure at inducer exit at $\varphi$=0.073.

  • PDF

An Experimental Study on Influence of Suction Path to Performance and Cavitation for Turbopump (흡입 유로 형상이 터보펌프의 성능 및 캐비테이션에 미치는 영향에 관한 실험적 연구)

  • Kang, Byung Yun;Chu, Sung Han;Kang, Shing-Hyoung
    • The KSFM Journal of Fluid Machinery
    • /
    • v.16 no.2
    • /
    • pp.21-26
    • /
    • 2013
  • Super-cavitating vehicle which is operating under water speeds up to 100m/s. In this process super-cavitation around body reduces frictional resistance. This paper introduces experimental study on different width of suction path as there is a warhead in the torpedo. Hydraulic performances of turbopump at non-cavitating condition does not display a significant differences depending on different width of suction path. However, cavitation performance of each model shows obvious differences in the same condition of experience. In case of radial inlet, the value of critical NPSH(which indicates 3% head drop) increases about 20% in comparison of axial inlet.

Characteristics of Exit Flow and Performance of a Turbopump Inducer (터보펌프 인듀서의 출구 유동 및 성능 특성)

  • Hong, Soon-Sam;Koo, Hyun-Chul;Cha, Bong-Jun;Kim, Jin-han
    • The KSFM Journal of Fluid Machinery
    • /
    • v.6 no.4 s.21
    • /
    • pp.38-44
    • /
    • 2003
  • Flow field downstream of an inducer was measured to see the flow and performance characteristics of a turbopump inducer. A large axisymmetric collector instead of a volute casing was installed to obtain circumferentially uniform flow - without interaction of the inducer and the volute. A conventional 3-hole probe was used to measure the flow. At inducer exit, axial component of absolute velocity decreased on hub region with decrease in flow rate. Tangential velocity component, static pressure, and total pressure increased from hub to tip. Relative flow angle from tangential direction was a little higher than outlet blade angle at flow coefficient ${\phi}=0.087$ and 0.073. Dynamic pressure was $53\%$ of the mean total pressure at inducer exit at ${\phi}=0.073$.

NUMERICAL STUDY ON THE TURBOPUMP INDUCER (터보펌프 인듀서에 대한 수치해석적 연구)

  • Noh Jun-Gu;Choi Chang-Ho;Hong Soon-Sam;Kim Jinhan
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2005.10a
    • /
    • pp.299-303
    • /
    • 2005
  • The present study focuses on the flow analysis of a turbopump inducer by performing both numerical and experimental methods. The head rise, efficiency and detailed flow fields such as outlet flow angles, pressure and velocity vectors are measured and compared with the computational data. Generally a good agreement is obtained between numerical and experimental results. However, some discrepancies are observed due to complex flow structures inside the inducer. Future calculations with an advanced turbulence model and a dense computational grid needs to be performed to obtain accurate numerical solution for the detailed flow fields.

  • PDF