• Title/Summary/Keyword: Turbo Molecular Pump

Search Result 35, Processing Time 0.028 seconds

An Experimental Study on the Pumping Performance of the Turbo-Type Disk-Type Drag Pump (터보형 원판형 드래그펌프의 배기특성에 관한 실험적 연구)

  • Hwang Young-Kyu;Heo Joong-Sik;Kwon Myung-Keun;Lee Seung-Jae
    • Proceedings of the KSME Conference
    • /
    • 2002.08a
    • /
    • pp.577-580
    • /
    • 2002
  • In this paper, the pumping performance of the disk-type drag pump which works in the outlet pressure range from 4 to 0.001 Torr is studied experimentally. The pumping characteristics of various drag pumps are performed. The inlet pressures are measured for various outlet pressures of the test pump. The flow-meter method is adopted to calculate the pumping speed. Compression ratios and pumping speeds for the nitrogen gas are measured. The present experimental data show the leak-limited value of the compression ratio in the molecular transition region. The rotational speed of the pump is 24,000rpm. The inlet pressures are measured for various outlet pressures of the test pump. The ultimate Pressures for zero throughput are measured for three-stage, two-stage and single-stage disk-type, respectively.

  • PDF

A numerical study of the performance of a turbomolecular pump (터보분자펌프의 성능해석에 관한 수치해석적 연구)

  • Hwang, Yeong-Gyu;Heo, Jung-Sik
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.20 no.11
    • /
    • pp.3620-3629
    • /
    • 1996
  • In the free molecular flow range, the pumping performance of a turbomolecular pump has been predicted by calculation of the transmission probability which employs the integral method and the test particle Monte-Carlo method. Also, new approximate method combining the double stage solutions, so called double-approximation, is presented here. The calculated values of transmission probability for the single stage agree quantitatively with the previous known numerical results. For a six-stage pump, the Monte-Carlo method is employed to calculate the overall transmission probability for the entire set of blade rows. When the results of the approximate method combining the single stage solutions are compared with those of the Monte-Carlo method at dimensionless blade velocity ratio C=0.4, the previous known approximate method overestimates as much as 34% than does the Monte-Carlo method. But, the new approximate method gives more accurate results, whose relative error is 10% compared to the Monte-Carlo method, than does the previous approximate method.

Studies on the characteristics of the Resonance Ionization Mass Spectrometor (공명 이온화 질량분석장치 (RIMS) 제작 및 특성연구)

  • 노시표
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 1991.06a
    • /
    • pp.199-202
    • /
    • 1991
  • 기체 시로의 정밀한 분석이 가능한 공명이온화 질량분석장치(Resonance lonization Mass Spectrometor)를 설계, 제작하고 그 특성을 분석하였다. 두 개의 터보펌프(turbo-molecular pump)로 차등펌핑하여 1*10-7Torr 의 진공도를 얻었으며, Nd:YAG 레이저로 광펌핑되는 색소레이저를 분자빔에 조사하여 공명다광자 이온화현상에 의해 발생되는 이온들을 가속시켜 질량을 측정하였다. 아닐린을 시료로 사용하여 분석한 결과 최대 분해능 200을 얻었다.

  • PDF

Characterization of turbo molecular pump design by a computational simulation (컴퓨터 시뮬레이션을 터보 분자 펌프 동작 특성 해석)

  • Ju, Jeong-Hun
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2015.05a
    • /
    • pp.83-83
    • /
    • 2015
  • 터보 분자 펌프는 수 만 rpm의 고속으로 회전하여 분자 유동 영역에서 효율적으로 기체를 배기하는 특성을 가지고 있지만 실제 플라즈마 공정에서는 챔버의 압력이 수 mTorr이상이므로 점성 유동 영역이나 전이 유동 영역에 해당한다. 따라서 터보 분자 펌프의 rotor, blade, stator등의 설계가 점성 유동 영역에서 반응성 가스 및 플라즈마 특성에 의해서 어떤 영향을 받는지 수치 모델을 통하여 해석을 시도하였다.

  • PDF

고진공펌프의 상태진단 시스템

  • Jeong, Wan-Seop;Nam, Seung-Hwan;Kim, Wan-Jung;Im, Jong-Yeon
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.08a
    • /
    • pp.101-101
    • /
    • 2012
  • 본 논문은 현재 제품화 단계로 진행 중인 터보 분자펌프(turbo-molecular pump, TMP)와 극저온 펌프(cryopump)의 고장 방지 및 예지 보수를 위한 상태 진단 시스템에 대하여 소개를 한다. 본 상태 진단 시스템은 고진공 펌프들의 다중 상태변수 즉 흡/배기부의 진공 압력, 부위별 온도, 소비 전류(혹은 전력), 그리고 부위별 진동 신호들을 실시간으로 측정하는 상태변수 수집장치, 수집된 시계열 상태변수들이 저장된 database, 그리고 저장된 상태변수를 이용한 고진공펌프의 상태진단 프로그램으로 구성되어 있다. 금번 연구에서 구축한 상태변수 체계의 특징 중 하나는 진동신호를 상태변수로 측정하여 이를 상태진단에 활용하는 점이 기존의 접근방법과 상이한 점이다. 실시간 신호 수집장치는 NI사 PXI 시스템 기반의 16채널 24-bit 동시 전압신호 측정 모듈, 8부위의 온도 측정장치(Lakeshore 218S, RS-232C 통신), 그리고 펌프의 소비전류/전력 측정장치(Hioki 3169, RS-232C), 그리고 고진공 펌프의 흡입 및 배기구의 진공도 측정장치로 구성하였다. 신호 수집용 프로그램은 NI사 Labview를 이용하여 작성하였다. 본 장치는 Nano-Fab 센터의 협조 하에 turbo-molecular 펌프와 cryopump측정 단에 각각 1대를 설치 완료하였으며 현재까지 운용 중이다. PC에 저장된 시계열 상태변수 database는 기 개발된 적응형 인자모델을 이용한 매개변수로 변환되며, 상태진단은 변환된 매개변수를 이용하여 수행할 예정이다.

  • PDF

Irradiation of Intense Characteristic X-rays from Weakly Ionized Linear Plasma

  • Sato, Eiichi;Hayasi, Yasuomi;Tanaka, Etsuro;Mori, Hidezo;Kawai, Toshiaki;Takayama, Kazuyoshi;Ido, Hideaki
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2002.09a
    • /
    • pp.396-399
    • /
    • 2002
  • Intense quasi-monochromatic x-ray irradiation from the linear plasma target is described. The plasma x-ray generator employs a high-voltage power supply, a low-impedance coaxial transmission line, a high-voltage condenser with a capacity of about 200 nF, a turbo-molecular pump, a thyristor pulse generator as a trigger device, and a flash x-ray tube. The high-voltage main condenser is charged up to 55 kV by the power supply, and the electric charges in the condenser are discharged to the tube after triggering the cathode electrode. The x-ray tube is of a demountable triode that is connected to the turbo molecular pump with a pressure of approximately 1 mPa. As electron flows from the cathode electrode are roughly converged to the molybdenum target by the electric field in the tube, the weakly ionized plasma, which consists of metal ions and electrons, forms by the target evaporating. In the present work, the peak tube voltage was almost equal to the initial charging voltage of the main condenser, and the peak current was about 20 kA with a charging voltage of 55 kV. When the charging voltage was increased, the linear plasma x-ray source grew, and the characteristic x-ray intensities of K-series lines increased. The quite sharp lines such as hard x-ray lasers were clearly observed. The quasi-monochromatic radiography was performed by a new film-less computed radiography system.

  • PDF

이온소스 Cathode 형태가 이온 빔에 미치는 영향

  • Min, Gwan-Sik;Lee, Seung-Su;Yun, Ju-Yeong;Jeong, Jin-Uk;O, Eun-Sun;Hwang, Yun-Seok;Kim, Jin-Tae
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2014.02a
    • /
    • pp.145.1-145.1
    • /
    • 2014
  • 변형된 end-Hall type의 이온 소스를 사용하여 이온 소스의 형태에 따라 달라지는 이온 빔의 변화를 측정하였다. 이온 소스 cathode의 wehnelt mask를 세 가지 종류로 제작하였으며, 생성된 이온 빔을 이용하여 Al이 sputter 방식으로 증착된 유리 기판을 etching 하였다. 실험 결과 wehnelt mask의 모양에 따라 focus, broad, strate의 형태로 이온 빔이 생성되는 것을 확인하였다. Al이 증착된 유리 기판의 제작을 위하여 Al target을 사용하여 RF power로 150 W, 2분간 sputtering을 하였고, 이온 소스와 기판사이의 거리를 1 cm씩 증가시켜가며 이온 빔을 2,500 V로 3분간 유리 기판을 etching한 후, 유리 기판이 etching된 모양을 통해 이온 빔의 형태를 분석하였다. 본 연구를 위하여 sputtering과 이온 빔 처리가 가능한 챔버를 제작하였으며, scroll pump와 turbo molecular pump를 사용하였다. Base pressure $1.5{\times}10^{-6}Torr$에서 실험이 진행되었고, 불활성 기체 Ar을 사용하였다. Ar 기체를 주입시 pressure는 $2.6{\times}10^{-3}Torr$였다.

  • PDF

보조펌프(backing pump)의 배기용량에 따른 터보분자펌프(TMP) 배기속도 측정에 관한 연구

  • Kim, Wan-Jung;Gang, Sang-Baek;Go, Mun-Gyu;Jeong, Wan-Seop;Im, Jong-Yeon
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2011.02a
    • /
    • pp.362-362
    • /
    • 2011
  • 터보분자펌프(turbo-molecular pump: TMP)는 고진공펌프 중의 하나로, 반도체/디스플레이 등 첨단 공정에서 진공 환경을 조성하는 핵심장비이다. 터보분자펌프(TMP)의 특성평가는 세계 여러 나라의 표준제정기구에서 제정한 국제규격에 그 기반을 두어, 한국표준과학연구원 진공기술 센터에서는 터보분자펌프(TMP) 특성평가시스템을 자체 설계/제작하여 그 신뢰성을 확인하기 위해 개발품 및 상용품 평가에 주력하고 있다. 터보분자펌프(TMP)는 보조펌프(backing pump)의 지원을 받으므로 보조펌프(backing pump) 용량에 따른 터보분자펌프(TMP)의 배기속도를 측정하고자 한다. 국제규격에서 제시하는 보조펌프 (backing pump)의 용량이 일정이상 작을 경우, 터보분자펌프(TMP)의 배기속도 및 압축비에 대해 감소함을 제시한다. 이 영향은 전체 압력 범위에서 보조펌프(backing pump)의 배기속도가 일정 용량 이상이면 터보분자펌프(TMP)의 배기속도에 영향이 없음을 제시하며, 이에 본 연구에서는 국제규격에서 제시하는 보조펌프(backing pump) 용량에 대해 서로 다른 조건에 맞추어 터보분자 펌프(TMP)의 배기속도에 미치는 영향을 연구하고자 한다. 본 연구에서는 100m3/h, 10m3/h 의 서로 다른 배기속도를 가진 보조펌프(backing pump)를 선정하여 분자량이 다른 가스(N2, He, Ar 등)에 대한 압축비의 변화와 배기속도 측정에 관해 상관 관계를 제시하며, 100m3/h, 10m3/h 의 서로 다른 배기속도를 가진 보조펌프(backing pump)에 따른 터보분자펌프(TMP)의 배기속도 및 운전성능을 제시하고자 한다.

  • PDF

Development of UBMS(Unbalanced Magnetron Sputtering) System and Ion Current Density Measurement of Copper Target (UBM 마그네트론 스퍼터 시스템을 이용한 구리 타겟의 이온전류밀도 향상 연구)

  • Kang, Chunghyeon;Joo, Junghoon
    • Journal of the Korean institute of surface engineering
    • /
    • v.50 no.3
    • /
    • pp.192-197
    • /
    • 2017
  • A 6-way-cross consisting of a 2.75-inch CF flange was used as a main chamber on a PFEIFFER VACUUM TMP station based on a 67 l / sec turbo molecular pump and a diaphragm pump to produce a magnet array with a volume ratio of 5.5: 1.A 1-inch diameter copper target and graphite target were fabricated using MDX-1.5K from Advanced Energy Industries, Inc as a DC power supply. Ion current density of copper target and graphite target was measured by unbalanced magnetron sputtering. The basic pressure condition was $6.3{\times}10^{-7}mbar$ and the process pressure was Ar 50 sccm at $1.0{\times}10^{-2}mbar$ (7.5 mTorr) in the Ar atmosphere. Therefore, the relative density of copper ions reaching the substrate with the measured ion current density was derived.

Tribological Characteristics of Si-Diamond-Like Carbon Films in a Condition with Carbon Nanotube Ink Lubricant (Carbon Nanotube 잉크 환경에서의 Si-Diamond-Like Carbon 박막의 내마모 특성)

  • Jang, Kil-Chan;Kim, Tae-Gyu
    • Korean Journal of Materials Research
    • /
    • v.21 no.3
    • /
    • pp.149-155
    • /
    • 2011
  • We investigated tribological characteristics of diamond-like carbon (DLC) in a condition with carbon nanotube (CNT) content of 1wt% in aqueous solution. Si-DLC films were deposited by radio frequency plasma enhanced chemical vapor deposition (RF-PECVD) process on Al6061 aluminum alloy. In this study, the deposition of DLC films was carried out in vacuum with a chamber pressure of 10-5 to 10-3 Torr achieved by mechanical pump followed by turbo molecular pump. The surface adsorbed oxygen on the Aluminum substrates was removed by passing Ar gas for 10 minutes. The RF power was maintained at 500W throughout the experiment. A buffer layer of HMDSO was deposited on the substrate to improve the adhesion of DLC coating. At this point CH4 gas was introduced in the chamber using gas flow controller and DLC coating was deposited on the buffer layer along with HMDSO for 50 min. The thickness of 1 ${\mu}m$ was obtained for DLC films on aluminum substrates The tribological properties of as synthesized DLC films were analyzed by wear test in the presence of dry air, water and lubricant such as CNT ink.