• Title/Summary/Keyword: Turbine rotor

Search Result 882, Processing Time 0.022 seconds

Effect of Blade Angles on a Micro Axial-Type Turbine Operated in a Low Partial Admission Rate (부분분사 마이크로 축류형터빈에서의 익형각 효과에 관한 연구)

  • Cho, Soo-Yong;Cho, Bong-Soo;Cho, Chong-Hyun
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.11 no.4
    • /
    • pp.10-18
    • /
    • 2007
  • A tested micro axial-type turbine consists of two stages and its mean radius of rotor flow passage is 8.4 mm. This turbine could be applied to a driver of micro power system, and its rotational speed in the unloaded state reaches to 100,000 RPM. The performance of this system is sensitive depending on the blade angles of the rotor and stator because it is operated in a low partial admission rate, so a performance test is conducted through measuring the specific output power and the net specific output torque with various blade angles on the nozzle, stator and rotor. The experimental results show that the net specific output torque is varied by 15% by changing the rotor blade angle, and the optimal incidence angle is about $10.3^{\circ}$.

Evaluation of the High Temperature Degradation of the Rotor of a 500 MW Tandem Steam Turbine (500 MW급 텐덤형 스팀 터빈 로터의 고온 열화평가)

  • Ku, Dae-Hwan;Yoo, Ho-Sun;Moon, Seung-Jae
    • Plant Journal
    • /
    • v.10 no.1
    • /
    • pp.40-46
    • /
    • 2014
  • The metallographic examination and hardness measurements were conducted for the rotor of the 500 MW tandem steam turbine of Unit 4 in Dangjin Thermal Power Plants at the locations of steam inlet where the high temperature steams pass; high and intermediate pressure turbines. Creep cavity and degradation levels of optical micrographs of them are observed. The remaining life time of 201,523h for the rotor of the 500 MW tandem steam turbine of Unit 4 in Dangjin Thermal Power Plants was determined by the results of the inspection.

  • PDF

Effect on Vibration of Start-up Condition and Retrofit of Steam Turbines (증기터빈의 기동조건과 성능개선이 터빈의 진동에 미치는 영향)

  • Lee, Hyuk Soon;Chung, Hyuk Jin;Song, Woo Sok
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • v.7 no.3
    • /
    • pp.1-7
    • /
    • 2011
  • The analysis shows that the vibration is one of the main reasons of turbine failure. Especially, the problems caused by vibration occur right after retrofit of the turbine-generator and restarting the turbine. Through the case study of high vibration caused by after the turbine trip and restart, turbine vibration was identified to be influenced by startup condition. Turbine startup at high casing temperature right after unscheduled turbine trip cause radial expansion in rotor by contraction in axial direction, while casing continues to contract by steam flowing into casing. Consequently, gap between rotor and casing decrease until to metal contact to cause high vibration. Through the case study of high vibration of turbine-generator system after generator retrofit, it was identified that generator replacement could cause high vibration in turbine-generator system if the influence of generator replacement on entire system was not considered properly. To prevent startup delay caused by high vibration, it is important to keep the gaps at the design standard and start the turbine after thermal equilibrium.

A Study on the Nozzle-Rotor Interactions of Partial Admission Supersonic Turbines

  • Seong, Young-sik;Han, Seong-hoon;Kim, Kui-soon;Park, Chang-kyu
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2004.03a
    • /
    • pp.391-397
    • /
    • 2004
  • The performance characteristics of partial admission supersonic turbines are analyzed by using the commercial CFD program FLUENT6.0. The governing equations were discretized with Euler implicit method in time and 2nd-order upwind scheme of FVM in space. The k-$\varepsilon$ turbulence model was utilized to describe the turbulent flow field. In order to investigate the nozzle--rotor interactions and the effect of partial admission, the flows in supersonic turbine rotor cascades with a nozzle are computed. Extensive computations of partial admission supersonic turbines provide the shock structures and flow patterns in the nozzle and rotor. It is clearly shown that the nozzle flow is highly affected by the shocks or expansion waves propagated from the rotor leading edge. And the rotor flow is also affected by the shocks or wakes originated from the nozzle.

  • PDF

Mechatronic Control Model of the Wind Turbine with Transmission to Split Power

  • Zhang Tong;Li Wenyong;Du Yu
    • International Journal of Control, Automation, and Systems
    • /
    • v.3 no.4
    • /
    • pp.533-541
    • /
    • 2005
  • In this paper, a wind turbine with power splitting transmission, which is realized through a novel three-shaft planetary, is presented. The input shaft of the transmission is driven by the rotor of the wind turbine, the output shaft is connected to the grid via the main generator (asynchronous generator), and the third shaft is driven by a control motor with variable speed. The dynamic models of the sub systems of this wind turbine, e.g. the rotor aerodynamics, the drive train dynamics and the power generation unit dynamics, were given and linearized at an operating point. These sub models were integrated in a multidisciplinary dynamic model, which is suitable for control syntheses to optimize the utilization of wind energy and to reduce the excessive dynamic loads. The important dynamic behaviours were investigated and a wind turbine with a soft main shaft was recommend.

A Study on the Aerodynamic Design of Three-Dimensional Axial Type Turbine Blade (3차원 축류형 터빈익형의 공력설계에 관한 연구)

  • Jang, B.I.;Kim, D.S.;Cho, S.Y.
    • Journal of Power System Engineering
    • /
    • v.5 no.3
    • /
    • pp.38-47
    • /
    • 2001
  • One stage axial type turbine is designed by mean-line analysis, streamline curvature method and blade design method using shape parameters. Tip and hub diameter of the turbine are 300mm and 206.4mm, respectively. The rotating speed is 1800RPM, and the output power is 1.4kW. The flow coefficient is 1.68 and the reaction factor at mean-line is 0.373. The number of stator and rotor of the turbine are 31 and 41, respectively. Mach number of stator exit flow near hub is 0.164. A test rig is developed for performance test to validate a developed design method. The experimental result shows that the maximum efficiency is obtained on the design point.

  • PDF

Critical Speed Analysis of a Small Gas Turbine Rotor (소형 가스터빈 회전체의 위험속도 해석)

  • Kim, Young-Cheol;Ha, Jin-Woong;Myung, Ji-Ho
    • The KSFM Journal of Fluid Machinery
    • /
    • v.12 no.3
    • /
    • pp.26-30
    • /
    • 2009
  • This paper predicts the critical speeds of a 5MW industrial gas turbine by using commercial rotordynamic tool, DYNAMICS 4.3. The gas turbine is operated at 12,975 rpm on squeeze film dampers. The stiffness of the squeeze film dampers are estimated. The critical speeds of the gas turbine rotor are calculated to have a sufficient separation margin (2%) from the 1st bending mode and pass over 2 rigid body modes below 4,000 cpm. This paper discussed the coupling effects on the dynamic response of the gas turbine.

Dynamic Characteristic Analysis of a Wind Turbine Depending on Varying Operational Conditions (작동 조건 변화에 따른 풍력발전 시스템의 동적 특성 해석)

  • Nam, Yoon-Su;Yoon, Tai-Jun;Yoo, Neung-Soo
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.33 no.1
    • /
    • pp.42-48
    • /
    • 2009
  • A design methodology for control strategy and control structure gives a direct impact on wind turbine's performance and life cycle. A baseline control law which is a variable rotor speed and variable pitch control strategy is introduced, and a mathematic performance model of a wind turbine dynamics is derived. By using a numeric optimization algorithm, the steady state operating conditions of wind turbines are identified. Because aerodynamic interaction of winds with rotor blades is basically nonlinear, a linearization procedure is applied to analyze wind turbine dynamic variations for whole operating conditions. It turns out the wind turbine dynamics vary much depending on its operating condition.

A Study on the Dynamic Characteristics of Turbine due to the Stiffness of Bearing-Pedestal (베어링-지지구조물의 영향에 따른 터빈의 동특성 변화)

  • Kim, Hee-Soo;Bae, Yong-Chae;Kim, Yeon-Whan;Lee, Hyun;Kim, Sung-Hwi;Lee, Young-Shin
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2000.06a
    • /
    • pp.1871-1874
    • /
    • 2000
  • It is impossible to predict accurately the dynamic behavior of turbine-generator system because bearing, and rotor characteristics are nonlinear and different from temperature, load, operation speed and bearing lubricant oil property. Especially, the characteristics of turbine hoods affect much the entire vibration characteristics of turbine. As the dynamic stiffness of turbine hoods are changed, the critical speeds of rotor are shifted. In this paper, the vibration behavior of turbine-generator is analyzed by using component mode synthesis and the critical speeds measured during shut-down are compared with the analytic results. It is confirmed that the 1st natural frequency and the mode shape are well in agreement with actual measured data.

  • PDF

Effect of Shroud Split on the Performance of a Turbopump Turbine Rotor (터보펌프 터빈 로터의 슈라우드 스플릿이 성능에 미치는 영향)

  • Lee, Hanggi;Jeong, Eunhwan;Park, Pyungoo;Yoon, Sukhwan;Kim, Jinhan
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.17 no.4
    • /
    • pp.25-31
    • /
    • 2013
  • A blisk with rotor shroud is usually adopted in LRE turbine to maximize its performance. However it experiences the severe thermal load and resulting damage during engine stating and stop. Shroud splitting is devised to relieve the thermal stress on the turbine rotor. Structural analysis confirmed the reduction of plastic strain at the blade hub and tip. However, split gap at the rotor shroud entails additional tip leakage and results performance degradation. In order to assess the effect of shroud split on the turbine performance, tests have been performed for various settings of shroud split. For the maximum number of shroud splitting, measured efficiency reduction ratio was 2.65% to the value of original shape rotor.