• Title/Summary/Keyword: Turbine Impeller

Search Result 91, Processing Time 0.024 seconds

Experimental Analyses of Flow in a Production Torque Converter Using LDV (LDV를 이용한 토크컨버터 내 유동의 실험적 분석)

  • Yoo, S.C.
    • Journal of the Korean Society of Mechanical Technology
    • /
    • v.20 no.6
    • /
    • pp.757-762
    • /
    • 2018
  • LDV(laser Doppler velocimetry) measurements were conducted on the exit region of the impeller passage and the gap between the impeller and turbine blades under 0.8 speed ratio. The 0.8 speed ratio has an impeller speed of 2000rpm and a turbine speed of 1600rpm. A periodic variation of the mass flow rate is present in many of the measurements made. The frequency of this variation is the same as the frequency of the turbine blades passing the impeller passage exit. It is found that the instantaneous position of the turbine had effect on fluid flow inside the impeller passage and gap region. This study would aid in the construction of higher accuracy CFD models of this complex turbomachinery device.

Loss Analysis by Impeller Blade Angle in the S-Curve Region of Low Specific Speed Pump Turbine

  • Ujjwal Shrestha;Young-Do Choi
    • New & Renewable Energy
    • /
    • v.20 no.2
    • /
    • pp.35-43
    • /
    • 2024
  • A pump turbine is a technically matured option for energy production and storage systems. At the off-design operating range, the pump turbine succumbed to flow instabilities, which correlated with the pump turbine geometry. A low specific speed pump turbine was designed and modified according to the impeller blade angle. Reynolds-Average Navier-Stokes is carried out with a shear stress transport turbulence model to evaluate the detailed flow characteristics in the pump turbine. The impeller blade inlet angle (𝛽1) and outlet angle (𝛽2) are used to evaluate hydraulic loss in the pump turbine. When 𝛽1 changed from low to high value, the maximum efficiency is increased by 4.75% in turbine mode. The S-Curve inclination is reduced by 8% and 42% for changes in 𝛽1 and 𝛽2 from low to high values, respectively. At α = 21°, the shock loss coefficient (𝜁s) is reduced by 16% and 19% with increases of 𝛽1 and 𝛽2 from low to high values, respectively. When 𝛽1 and 𝛽2 values increased from low to high, the impeller friction coefficient (𝜁f) increased and decreased by 20% and 8%, respectively. Hence, the high 𝛽2 effectively reduced the loss coefficient and S-Curve inclination.

A Study on Unsteady Flow Characteristics in Industrial Mixers with Various Types Impeller by PIV (PIV에 의한 교반기내의 산업용 임펠러형태에 따를 비정상 유동특성에 관한연구)

  • Nam, Koo-Man;Kim, Beom-Seok;Kim, Jeong-Hwan;Kang, Mun-Hu;Lee, Young-Ho
    • 유체기계공업학회:학술대회논문집
    • /
    • 2003.12a
    • /
    • pp.678-683
    • /
    • 2003
  • Mixers are used in various industrial fields where it is necessary to intimately mix two reactants in a short period of time. However, despite their widespread use, complex unsteady flow characteristics of industrial mixers are not systematic investigated. The present study aimed to clarify unsteady flow characteristics induced by various impellers in a tank. Impellers are pitched blade turbine and neo-hydrofoil turbine types. A high speed CCD camera and an Ar-Ion laser for illumination were adopted to clarify the time-dependent flow characteristics of the mixers. The rotating speed of impellers increased from 6Hz to 60Hz by 6Hz. The maximum velocity around PBT impeller is higher than the hydrofoil type impeller. These two types of turbine shows that typical flow characteristics of axial turbine and suitable for mixing high -viscosity materials.

  • PDF

Design of a Pump-Turbine Based on the 3D Inverse Design Method

  • Chen, Chengcheng;Zhu, Baoshan;Singh, Patrick Mark;Choi, Young-Do
    • The KSFM Journal of Fluid Machinery
    • /
    • v.18 no.1
    • /
    • pp.20-28
    • /
    • 2015
  • The pump-turbine impeller is the key component of pumped storage power plant. Current design methods of pump-turbine impeller are private and protected from public viewing. Generally, the design proceeds in two steps: the initial hydraulic design and optimization design to achieve a balanced performance between pump mode and turbine mode. In this study, the 3D inverse design method is used for the initial hydraulic impeller design. However, due to the special demand of high performance in both pump and reverse mode, the design method is insufficient. This study is carried out by modifying the geometrical parameters of the blade which have great influence and need special consideration in obtaining the high performance on the both modes, such as blade shape type at low pressure side (inlet of pump mode, outlet of turbine mode) and the blade lean at blade high pressure side (outlet of pump mode, inlet of turbine mode). The influence of the geometrical parameters on the performance characteristic is evaluated by CFD analysis which presents the efficiency and internal flow results. After these investigations of the geometrical parameters, the criteria of designing pump-turbine impeller blade low and high sides shape is achieved.

A Numerical Analysis on Mixing Performance for Various Types of Turbine Impeller in a Stirred Vessel (교반기 내 터빈 임펠러 형태에 따른 교반성능에 대한 수치해석적 연구)

  • Choi, Younguk;Choi, Jongrak;Kim, Daejoong;Hur, Nahmkeon
    • The KSFM Journal of Fluid Machinery
    • /
    • v.16 no.1
    • /
    • pp.47-55
    • /
    • 2013
  • In the present study, a numerical simulation to analyze mixing performance inside an industrial mixer was investigated for various geometry of turbine impellers. Various pitching angles and various types of turbine blades were considered in the simulation. In order to model the rotation of impeller, the Multiple Reference Frames (MRF) technique was used. For evaluation of the effect of various shapes on the mixing performance, dimensionless coefficient such as flow coefficient, circulation coefficient, power coefficient, pumping effectiveness and circulation effectiveness were used. From the results, the effect of pitching angle of a pitched turbine impeller was to give best pumping effectiveness around $30^{\circ}$ pitching angle, whereas best circulation effectiveness around $65^{\circ}$ pitching angle. Dual pitched turbine impeller showed best performance in both pumping effectiveness and circulation effectiveness among impeller types considered in the present study.

Experimental Study on Off-Design Performance of a Small Centrifugal Compressor for Gas Turbine Applications (가스터빈용 소형 원심압축기의 탈설계점 성능에 관한 실험연구)

  • Oh, JongSik;Lee, HeonSeok;Oh, KoonSup
    • 유체기계공업학회:학술대회논문집
    • /
    • 2000.12a
    • /
    • pp.211-218
    • /
    • 2000
  • Off-design experimental performance was investigated for a small centrifugal compressor, whose impeller diameter is about 125mm, used in an industrial gas turbine. Test rig was designed and manufactured with a radial inflow turbine and a combustor to supply driving power to the compressor. Static pressure was measured on the casing of the impeller, vaneless diffuser, vaned diffuser and volute. Total pressure was obtained using specially fabricated rakes at the vaned diffuser throat and exit. Circumferential nonuniformity was found, near surge, in the Impeller, vaned diffuser and volute region. Spanwise nonuniform flow from the impeller affected the total pressure defects in the vaned diffuser region. Static pressure distortion in the circumferential direction in the volute was found near surge, where the minimum occurred near 140 degree position.

  • PDF

Flow Characteristics about Industrial Agitators Impeller Shape by CFD (전산유체역학을 이용한 산업용교반기의 Impeller형상에 따른 유동특성)

  • Kim, D.K.;Bae, S.T.;Lee, C.J.;Park, J.H.;Kim, O.K.
    • Proceedings of the Korean Society of Marine Engineers Conference
    • /
    • 2006.06a
    • /
    • pp.321-322
    • /
    • 2006
  • Industrial agitators are used in various industrial fields where they are necessary to intimately mix two reactants in a short period of time. However, despite their widespread use, complex unsteady flow characteristics of industrial agitators are not systematically investigated. The present study alms for clarify unsteady flow characteristics induced by various impellers in a tank. Impellers are pitched blade turbine(PBT) types, Screw type and Rushton turbine type. In this study flow characteristics of the impeller using CFD. The rotating speed of impellers fixed about 100RPM. These three types of Impeller show that typical flow characteristics of axial turbine and suitable for mixing powder

  • PDF

Study on the Industrial Agitator's Impeller Shape Analysis Using CFD and Reverse Engineering (CFD와 역설계를 이용한 교반기 Impeller 형상 해석에 관한 연구)

  • Kim, D.K.;Bae, S.T.;Park, J.H.
    • Korean Journal of Computational Design and Engineering
    • /
    • v.11 no.5
    • /
    • pp.359-364
    • /
    • 2006
  • Industrial Agitators are used in various industrial fields where they are necessary to intimately mix two reactants in a short period of time. However, despite their widespread use, complex unsteady flow characteristics of industrial mixers are not systematically investigated. The present study aims for clarify unsteady flow characteristics induced by various impellers in agitator's tank. Impellers are Pitched blade turbine(PBT) types, Screw type and Rushton turbine type(RUT). In this study is numerical analysis of the Industrial agitator's Impeller types. The rotating speed of impellers fixed about 100RPM. Numerical analysis results show that differential flow characteristics of each type Impeller and Rushton turbine type(RUT) is suitable for mixing powder.

Numerical Study on Flow Patterns of Impeller's Type in a Stirred Tank (혼합탱크 내의 임펠라 형태에 따른 유동 특성에 관한 수칙해석)

  • Oh, Sueg-Young;Song, Gil-Sub
    • 유체기계공업학회:학술대회논문집
    • /
    • 2001.11a
    • /
    • pp.454-459
    • /
    • 2001
  • The present study is concerned with the flow patterns induced by other impellers in a rectangular tank Impellers are FBT(Flat blade turbine), PBT(Pitched blade turbine), Shroud turbine, Rushton Turbine, and Helical ribbon turbine. The solution of flows in moving reference frames requires the use of 'moving' cell zone. The moving zone approaches are MRF(Multiple reference frame), which is a steady-state approximation and Sliding method, which is a unsteady-state approximation. Numerical results using two moving zone approaches are compared with experiments by Ranade & Joshi, which have done extensive LDA measurements of the flow generated by a standard six-bladed Rushton turbine in a cylindrical baffled vessel. In this paper we simulated the flow patterns with above mentioned moving zone approaches and impellers. Turbulence model is RNG k-$\epsilon$ model.

  • PDF

A Numerical Study on an Optimum Design of a Cross-flow Type Power Turbine (CPT) (횡류형 파워터빈의 최적화 설계에 관한 수치해석 연구)

  • Ha, Jin-Ho;Kim, H.C.;Kim, Chul-Ho
    • Proceedings of the KSME Conference
    • /
    • 2007.05b
    • /
    • pp.3050-3055
    • /
    • 2007
  • A wind turbine is one of the most popular energy conversion systems to generate electricity from the natural renewable energy source and an axial-flow type wind turbine is the most popular system for the electricity generation in the wind farm nowadays. In this study, a cross-flow type turbine has been studied for the application of wind turbine for electricity generation. The target capacity of electric power generation of the model wind turbine developing on the project is 12 volts, 130A/H (about 1.56kW). The important design parameters of the model turbine impeller are the inlet and exit angle of the turbine blade, number of blade, hub/tip ratio and the exit flow angle of the casing. In this study, the radial equilibrium theorem was used to decide the inlet and exit angle of the impller blade and CFD technique was used to have the performance analysis of the designed model power turbine to find out the optimum geometry of the CPT impeller and casing. The designed CPT with 24 impeller blades at ${\alpha}=82^{\circ}$, ${\beta}=40^{\circ}$ of turbine blade angle was estimated to generate 284.6 N.m of indicated torque and 2.14kW of indicated power.

  • PDF