• Title/Summary/Keyword: Tungsten/Yttria

Search Result 3, Processing Time 0.016 seconds

Thermal Performance Evaluations on High-Erosion Resistance Materials for Very Small Nozzle Throat Inserts (장시간 연소용 초소형 저삭마 목삽입재 선정을 위한 내열성능 평가)

  • Kang, Yoon-Goo;Park, Jong-Ho
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.37 no.12
    • /
    • pp.1245-1251
    • /
    • 2009
  • This paper describes the research on the non-eroding throat insert materials under condition of high-temperature, high-pressure, and long-burn time. C/SiC, CIT and W/$Y_2O_3$ were chosen and tested in thermal protection evaluation motor of burning time 20 seconds. From the test results, a heat resistance of W/$Y_2O_3$ was the most excellent among them, but was happened crack on material surface. Thermal reaction characteristics and heat resistance of these materials and feasibility of W/$Y_2O_3$ as throat material were ascertained.

Thermal Performance Evaluations of Tungsten/Yttria as Nozzle Throat Insert Material for Long Duration Firing (장시간 연소 텅스텐/이트리아 노즐목 삽입재의 내열성능 평가)

  • Kang, Yoon-Goo;Park, Jong-Ho
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.38 no.2
    • /
    • pp.200-205
    • /
    • 2010
  • Heat-resistance of W/$Y_2O_3$ as throat insert material was evaluated to develop rocket motor keeping thrust uniformly under condition of high-temperature, high-pressure and long-burn time. Test was conducted with varying burn time, and test results were compared with CIT. Test showed that ablation rate was decreased according as burn time was increased, and that ablation rate of W/$Y_2O_3$ was about 55 % of CIT. Macro/micro structures of throat insert did not show a peculiar phenomenon by increased burn time. In addition, the vacuum heat treatment is effective for the prevention of crack in throat insert.

The Effect of Contamination of Ion Source on Ionic Current of Quadrupole Mass Spectrometer (사중극 질량 분석기의 이온소스 오염이 이온전류에 미치는 영향)

  • Lee, K.C.;Park, C.J.;Kim, J.T.;Oh, E.S.;Hong, K.S.;Hong, S.S.;Lim, I.T.;Yun, J.Y.;Kang, S.W.;Shin, Y.H.
    • Journal of the Korean Vacuum Society
    • /
    • v.18 no.3
    • /
    • pp.197-202
    • /
    • 2009
  • The long term stability of ion current of QMS has been one of key parameters for monitoring gas process in vacuum. The time dependence of ionic current was monitored while the pressure of nitrogen gas was kept at a fixed pressure by introducing the gas into vacuum chamber. The chamber was evacuated to ${\sim}3{\times}10^{-9}\;Torr$ to reduce background signals before the measurement. Two ion sources were tested; one had brownish or black color due to gas contamination and the other one was new, i.e. cleaner. At a nitrogen pressure of $1{\times}10^{-5}\;Torr$, the ionic currents measured by the contaminated ion source decreased faster with time. The decrease rate was respectively ${\sim}46%$ for cleaner one and ${\sim}84%$ for contaminated one after ${\sim}5.5%$ hours. In order to test the effect of filament material on the ion current decrease, we fabricated a tungsten(W) filament which consisted of two parts; one half was made of W and the other was coated with yttria. The similar decrease of ionic currents were shown for the two types of filaments, indicating that slight change of temperature of filament due to material difference i.e. baking effect could not improve the origin of ionic current decrease. Overall the decreasing rate of ionic current is more closely associated with contaminated ion source of QMS rather than its filament materials.