• Title/Summary/Keyword: Tukey Procedure

Search Result 42, Processing Time 0.033 seconds

Evaluation of at-home bleaching protocol with application on different surfaces: bleaching efficacy and hydrogen peroxide permeability

  • Heloisa Forville;Michael Willian Favoreto;Michel Wendlinger;Roberta Micheten Dias;Christiane Philippini Ferreira Borges;Alessandra Reis;Alessandro D. Loguercio
    • Restorative Dentistry and Endodontics
    • /
    • v.48 no.4
    • /
    • pp.33.1-33.12
    • /
    • 2023
  • Objectives: This study aimed to evaluate the bleaching efficacy and hydrogen peroxide permeability in the pulp chamber by the at-home bleaching gel in protocols applied on different dental surfaces. Materials and Methods: Forty premolars were randomly into 4 groups: control group no bleaching, only application on the buccal surface (OB), only application on the lingual surface (OL) and application in buccal and lingual surfaces, simultaneously (BL). At-home bleaching gel (White Class 7.5%) was used for the procedure. The bleaching efficacy was evaluated with a digital spectrophotometer (color change in CIELAB [ΔEab] and CIEDE 2000 [ΔE00] systems and Whitening Index for Dentistry [ΔWID]). The hydrogen peroxide permeability in the pulp chamber (㎍/mL) was assessed using UV-Vis spectrophotometry and data were analyzed for a 1-way analysis of variance and Tukey's test (α = 0.05). Results: All groups submitted to bleaching procedure showed bleaching efficacy when measured with ΔEab and ΔE00 (p > 0.05). Therefore, when analyzed by ΔWID, a higher bleaching efficacy were observed for the application on the groups OB and BL (p = 0.00003). Similar hydrogen peroxide permeability was found in the pulp chambers of the teeth undergoing different protocols (p > 0.05). Conclusions: The application of bleaching gel exclusively on the OB is sufficient to achieve bleaching efficacy, when compared to BL. Although the OL protocol demonstrated lower bleaching efficacy based on the ΔWID values, it may still be of interest and relevant in certain clinical scenarios based on individual needs, requiring clinical trials to better understand its specificities.

Effect of three nanobiomaterials on microhardness of bleached enamel

  • Khoroushi, Maryam;Shirban, Farinaz;Kaveh, Sara;Doustfateme, Samaneh
    • Restorative Dentistry and Endodontics
    • /
    • v.41 no.3
    • /
    • pp.196-201
    • /
    • 2016
  • Objectives: The aim of this in vitro study was to evaluate the effect of incorporating three different nanobiomaterials into bleaching material on microhardness of bleached enamel. Materials and Methods: The crowns of 24 extracted sound human molars were sectioned. Sixty enamel specimens ($2{\times}3{\times}4 mm$) were selected and divided into five groups (n = 12): Group 1 received no bleaching procedure (control); Group 2 underwent bleaching with a 40% hydrogen peroxide (HP) gel; Groups 3, 4, and 5 were bleached with a 40% HP gel modified by incorporation of bioactive glass (BAG), amorphous calcium phosphate (ACP) and hydroxyapatite (HA), respectively. The enamel microhardness was evaluated. The differences in Knoop microhardness data of each group were analyzed by one-way ANOVA, followed by post hoc Tukey tests. Results: Significant differences were observed between the study groups. The enamel microhardness changes in Groups 1, 3, 4, and 5 were significantly lower than that of Group 2 (p < 0.001). Conclusions: Within the limitations of this study, it can be concluded that incorporation of each one of the three tested biomaterials as remineralizing agents might be effective in decreasing enamel microhardness changes subsequent to in-office bleaching.

The Elementary Study of Minnesota Multiphasic Personality Inventory(MMPI) (다면적(多面的) 인성검사(人性檢査)(MMPT)에 관(關)한 초보적(初步的) 연구(硏究))

  • Shim Sang-Min;Kim Geun-Woo;Goo Byung-Soo;Heo Seong
    • Journal of Oriental Neuropsychiatry
    • /
    • v.12 no.2
    • /
    • pp.147-156
    • /
    • 2001
  • Objectives: In order to investigate personality of oriental medical students by MMPI elementarily. Methods: This study was done by comparing the score of MMPI and Sasang questionnaire. The scores of MMPI and Sasang were verified by examination of T-test and Tukey's HSD Procedure. Results: 1. According to comparison between male and female, there is no meaning. But between unmarried group and married group, there is a difference of MMPI T-scores for L, K-scale significantly. 2. In the distinction of sex and marriage between A group and B group, the MMPI T-scores of male and unmarried group have more significance on the various scale. 3. According to comparative anaylsis of MMPI and Sasang questionnaire, Um group(Tae-um, So-um group) showed significant results in D(Depression), PT(Psychasthenia), SI(Social Introversion) scales of the MMPI. 4. In comparison between the temperament of Sasang and analysis of MMPI profile, Tae-um and So-um groups showed many similarities. Conclusion: According to the above results, it is considered that MMPI can be applied to classification of constitution.

  • PDF

The effect of coloring liquids on the translucency of zirconia framework

  • Tuncel, Ilkin;Eroglu, Erdal;Sari, Tugrul;Usumez, Aslihan
    • The Journal of Advanced Prosthodontics
    • /
    • v.5 no.4
    • /
    • pp.448-451
    • /
    • 2013
  • PURPOSE. Translucency of all-ceramic restorations is an important factor which affects the final appearance and esthetic outcome of the restoration. The aim of this study was to evaluate the effect of the shade of coloring liquid on the translucency of zirconia framework. MATERIALS AND METHODS. Thirty zirconium oxide core plate ($15{\times}12{\times}0.5$ mm) were divided into 6 groups of 5 plates each. Each group was classified according to the shade of coloring liquid based on Vita Classic Scale (A2, A3, B1, C2, and D2), and each sample was immersed in coloring liquid for 3 seconds as recommended by the manufacturer, except for the control group. Contrast ratio, as a translucency parameter, was calculated using a spectrophotometer and the data were analyzed with oneway analysis of variance (ANOVA) and Tukey's honestly significant differences (HSD) tests (${\alpha}$=.05). RESULTS. Significant differences in translucency among the control and test groups, and the B1 shaded group and other shades was observed. There were no significant differences among A2, A3, C2, and D2 shaded groups. CONCLUSION. The translucency of the zirconium oxide cores was affected by the coloring procedure and significant differences in the translucency measurements were identified between specific shades.

The effect of various polishing systems on surface roughness and phase transformation of monolithic zirconia

  • Caglar, Ipek;Ates, Sabit Melih;Duymus, Zeynep Yesil
    • The Journal of Advanced Prosthodontics
    • /
    • v.10 no.2
    • /
    • pp.132-137
    • /
    • 2018
  • PURPOSE. The purpose of this study was to evaluate and compare three polishing systems on the surface roughness and phase transformation of monolithic zirconia. MATERIALS AND METHODS. 100 disk shaped specimens (10 mm diameter, 3 mm thickness) were fabricated from monolithic zirconia blocks. 20 specimens were left as a control group and remaining specimens were grinded by diamond bur to simulate the occlusal adjustments. Grinded specimens were randomly divided into 4 groups: group G (no polishing), group M (Meisinger, zirconia polishing kit), group E (EVE Diacera, zirconia polishing kit), and group P (EVE Diapol, porcelain polishing kit). Surface roughness was measured with profilometer and surface topography was observed with SEM. XRD analysis was performed to investigate the phase transformation. Statistical analysis was performed with one-way ANOVA and Tukey's post hoc tests at a significance level of P=.05. RESULTS. All polishing groups showed a smoother surface than group G. Among 3 polishing systems, group M and group E exhibited a smoother surface than the group P. However, no significant differences were observed between group M and group E (P>.05). Grinding and polishing did not cause phase transformations in zirconia specimens. CONCLUSION. Zirconia polishing systems created a smoother surface on zirconia than the porcelain polishing system. Phase transformation did not occur during the polishing procedure.

A Study of the Clinical Utility of the Four Square Step Test for Predicting Falls in Stroke Patients (뇌졸중 환자의 낙상 예측을 위한 Four Square Step Test의 활용에 관한 연구)

  • Kwon, Mi-Ji
    • The Journal of Korean Physical Therapy
    • /
    • v.22 no.4
    • /
    • pp.1-6
    • /
    • 2010
  • Purpose: This study was designed to evaluate the clinical utility of the Four square step test (FSST) for predicting falls in stroke patients, to compare the ability of the FSST test to discriminate between subgroups of fallers, and to determine if the test has any predictive value in identifying stroke patients who will fall. Methods: Stroke patients (N=37) who could walk at least 50 m with minimal assistance were recruited consecutively when attending a physical therapy session during their rehabilitation. Dynamic standing balance was measured using the FSST. The main outcome measures were FSST time and fall number. Numbers of falls were compared with FSST scores. Differences between the groups in FSST scores were examined using a t-test and 1-way analysis of variance. Post hoc analysis using the Tukey B procedure was used to identify specific group differences. Alpha was set at 0.05. Results: A total of 15 participants (40.5%) reported falls 6 had recurrent falls (2 falls) and 9 fell once. The mean FSST time differed significantly between groups with zero and multiple falls. A cutoff score of greater than 17 seconds on the FSST was associated with a sensitivity of 83% and a specificity of 84% for the identification of subjects with multiple risk factors for falls. Conclusion: The FSST is a feasible and valid clinical test of dynamic standing balance and can predict falls in post-stroke patients.

Effect of fluid contamination on reverse torque values in implant-abutment connections under oral conditions

  • Mostafavi, Azam Sadat;Memarian, Maryam;Seddigh, Mohammad Ali
    • The Journal of Advanced Prosthodontics
    • /
    • v.13 no.1
    • /
    • pp.65-70
    • /
    • 2021
  • Purpose. Implant mechanical complications, including screw loosening, can influence dental implant success. It has been shown that torque values are affected by contamination occurred in implant-abutment (I/A) interface. This study aimed to examine the effects of blood, saliva, fluoride and chlorhexidine contamination on reverse torque values (RTVs) of abutment screws in oral conditions. Materials and Methods. 50 fixtures were mounted into the stainless-steel holders and divided into five groups (n = 10). Except control group (NC), fixture screw holes in other groups were contaminated with chlorhexidine (CG), saliva (SG), blood (BG), or fluoride (FG). Abutment screws were tightened with a digital torque meter. I/A assemblies were subjected to thermocycling and cyclic loading. The mean RTVs were recorded and data were analyzed with one-way ANOVA and Tukey test. Results. Except for specimens in SG (20.56 ± 1.33), other specimens in BG (21.11 ± 1.54), CG (22.89 ± 1.1) and FG (24.00 ± 1.12) displayed significantly higher RTVs compared to NC (19.00 ± 1.87). The highest RTVs were detected in CG and FG. Conclusion. The obtained data robustly suggest that RTVs were significantly affected by fluid contaminations. Specimens in FG and CG displayed the highest RTVs. Therefore, clinicians should have enough knowledge about probable contaminations in I/A interface in order to manage them during clinical procedure and to inform patients about using oral care products.

Micro-computed tomography evaluation of general trends in aligner thickness and gap width after thermoforming procedures involving six commercial clear aligners: An in vitro study

  • Palone, Mario;Longo, Mattia;Arveda, Niki;Nacucchi, Michele;De Pascalis, Fabio;Spedicato, Giorgio Alfredo;Siciliani, Giuseppe;Lombardo, Luca
    • The korean journal of orthodontics
    • /
    • v.51 no.2
    • /
    • pp.135-141
    • /
    • 2021
  • Objective: To assess the effects of thermoforming on aligner thickness and gap width in six aligner systems with the same nominal thickness. Methods: Six passive upper aligners of different brands were adapted to a single printed cast. Each sample was evaluated with high-resolution micro-computed tomography. To investigate aligner thickness and gap width, two-dimensional (2D) analysis was conducted assessing the effects of the following variables: tooth type (central incisor, canine, and first molar), 2D reference points, and aligner type. Data were analyzed and compared using analysis of variance and Tukey's post-hoc tests (p < 0.05). Results: Tooth type, dental region, and aligner type affected both the gap width and aligner thickness. The aligner thickness remained moderately stable across the arch only in the F22. Conclusions: All thermoformed samples displayed smaller aligner thickness and gap width at anterior teeth and both gingival and coronal centers than at posterior teeth and occlusal surfaces.

The effect of cleaning methods on bond strength of zirconia after saliva contamination (타액으로 오염된 지르코니아 수복물의 접착강도에 세척 방법들이 미치는 영향)

  • Shim, Young-Bo;Choi, An-Na;Son, Sung-Ae;Jung, Kyoung-Hwa;Kwon, Yong Hoon;Park, Jeong-Kil
    • Korean Journal of Dental Materials
    • /
    • v.44 no.1
    • /
    • pp.61-68
    • /
    • 2017
  • This study evaluated the effects of various cleaning methods on the shear bond strength of zirconia ceramics after saliva contamination. Eighty zirconia disk specimens were divided into 8 groups. All groups were treated with one coat of MDP primer. All specimens (except the negative control) were contaminated with human saliva on the zirconia surface. The positive control went through the bonding procedure immediately after contamination without any cleaning procedure. With the exception of control groups, the remaining six groups were rinsed with water and either applied with MDP recoating (WATER+MDP) or without MDP recoating (WATER). While some were cleaned with a Ivoclean with MDP recoating (IVOCLEAN+MDP) or not applied with MDP recoating(IVOCLEAN), others were cleaned with a 1% NaOCl solution with MDP recoating (NaOCl+MDP) or without MDP recoating (NaOCl). The shear bond strength of all specimens were measured after being stored in distilled water at $37^{\circ}C$ for 24 hours. The data was analyzed statistically by an analysis of ANOVA, Tukey's post hoc test and Student's t-test was used to compare the shear bond strength according to the re-coating of MDP after the cleaning procedure. The positive control group showed the lowest shear bond strength value, and the WATER group and NaOCl group showed no significant difference when compared to the positive control group. The IVOCLEAN group showed significantly higher shear bond strength when compared to Water group and NaOCl group but not with the group of negative control. After rinsing with water or the NaOCl solution, the comparison of the single coating of MDP and re-coating of MDP showed different shear bond strengths but there was no significant difference to the negative control. After rinsing with Ivoclean, there was no significant difference to the negative control regardless of the recoating of MDP. In conclusion, the shear bond strength was affected by the cleansing procedure and Ivoclean was found to be effective regardless of the re-coating of MDP. When water or the NaOCl solution is used to remove surface contaminants, the re-coating of MDP provides a positive effect on cementation.

A SHEAR BOND STRENGTH OF RESIN CEMENT BONDED TO HUMAN UNCUT ENAMEL, CUT ENAMEL, AND DENTIN IN VITRO

  • Lee Jong-Yeop
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.41 no.3
    • /
    • pp.319-324
    • /
    • 2003
  • Statement of problem. Adhesives in dentistry playa major role in the success of restorative treatments. In the treatment of all ceramic restoration it is needed to find the adequate bond strength between enamel and dentin. Purpose. The purpose of this study was to evaluate shear bond strength of resin cement bonded to extracted human uncut enamel, cut enamel, and dentin in vitro. Material and methods. Ten freshly extracted anterior teeth without any previous restorative treatments were chosen. The extracted teeth were embedded in PMMA cold acrylic in the shape of a cylinder, 25 mm in diameter by 25 mm in height. The bonding system used was as follow: Uni-Etch (32% phosphoric acid), One-Step adhesive, Duolink resin cement. The specimens were acid etched and rinsed with water. Two layers of One-Step adhesive were coated with a disposable brush on the uncut enamel. VIP curing light at $500mV/cm^2$ was used to cure the adhesive. For cut enamel shear bond test, the specimen used for uncut enamel was further reduced approximately $0.3{\sim}0.5mm$ using a laminate preparation diamond bur (0.3 mm in depth). The specimens were subsequently treated with 320-grit SiC paper followed by 600-grit SiC paper and cleaned with distilled water. The bonding procedure on the cut enamel was same as uncut enamel bonding procedure. For dentin bonding test, the specimen used for cut enamel was further reduced approximately $0.5mm{\sim}1.0mm$ using a laminate preparation diamond bur (0.5 mm in depth of diamond cutting). The amount of reduction was evaluated with the silicone mold. The specimens were subsequently treated with 320-grit SiC paper followed by 600-grit silicon carbon paper and cleaned in distilled water. The bonding procedure on the dentin was same as uncut enamel bonding procedure. All samples were mounted and secured on the Ultradent shear bond test sample holder, and Ultradent restricted shear bond testing device was used with Universal Instron machine until fracture. Analysis of variance (ANOVA) test was performed comparing the result at P<0.05. Multiple comparison (Tukey) was used to compare each groups. Result. The result showed that the mean value in shear bond strength of resin cement bonded to uncut enamel, cut enamel and dentin were 27.04 Mpa, 30.25 Mpa and 26.39 Mpa with respect. Conclusion. Within the limitation of this study, the mean value of the shear bond strength of cut enamel was higher than those of uncut enamel or dentin. However there existed no statistical differences between three different human dentition substrates due to increased adhesive characteristics.