• Title/Summary/Keyword: Tubular

Search Result 1,897, Processing Time 0.022 seconds

Experimental and numerical analysis of fatigue behaviour for tubular K-joints

  • Shao, Yong-Bo;Cao, Zhen-Bin
    • Structural Engineering and Mechanics
    • /
    • v.19 no.6
    • /
    • pp.639-652
    • /
    • 2005
  • In this paper, a full-scale K-joint specimen was tested to failure under cyclic combined axial and in-plane bending loads. In the fatigue test, the crack developments were monitored step by step using the alternating current potential drop (ACPD) technique. Using Paris' law, stress intensity factor, which is a fracture parameter to be frequently used by many designers to predict the integrity and residual life of tubular joints, can be obtained from experimental test results of the crack growth rate. Furthermore, a scheme of automatic mesh generation for a cracked K-joint is introduced, and numerical analysis of stress intensity factor for the K-joint specimen has then been carried out. In the finite element analysis, J-integral method is used to estimate the stress intensity factors along the crack front. The numerical stress intensity factor results have been validated through comparing them with the experimental results. The comparison shows that the proposed numerical model can produce reasonably accurate stress intensity factor values. The effects of different crack shapes on the stress intensity factors have also been investigated, and it has been found that semi-ellipse is suitable and accurate to be adopted in numerical analysis for the stress intensity factor. Therefore, the proposed model in this paper is reliable to be used for estimating the stress intensity factor values of cracked tubular K-joints for design purposes.

Experimental Study on Thermal Performance of Various Heat Pipe Working Fluid for Evacuated Tubular Solar Collector (진공관형 태양열 집열기 히트파이프 작동유체에 따른 열성능 연구)

  • Joo, Hong-Jin;Kwak, Hee-Youl;Kim, Jeong-Bae;Kim, Jong-Bo
    • Proceedings of the SAREK Conference
    • /
    • 2007.11a
    • /
    • pp.70-75
    • /
    • 2007
  • This study was carried out to compare the thermal performance and operating characteristics of evacuated tubular solar collector(ETSC) with different working fluid. The evacuated tubular solar collectors with different working fluid of heat pipe were investigated in the same operating condition for a indoor experiment equipment. First, the result of working fluid with Water showed that $F_R({\tau}{\alpha})$ was 0.6636 and $F_{R}U_{L}$ was -1.8457. Second, Ethanol showed that $F_R({\tau}{\alpha})$ was 0.6147 and $F_{R}U_{L}$ was -0.6365. Third, Flutec-pp9 showed that $F_R({\tau}{\alpha})$ was 0.515 and $F_{R}U_{L}$ was -3.2313. Finally MA's showed that $F_R({\tau}{\alpha})$ was 0.6572 and $F_{R}U_{L}$ was -2.0086.

  • PDF

Fast Component Placement with Optimized Long-Stroke Passive Gravity Compensation Integrated in a Cylindrical/Tubular PM Actuator

  • Paulides, J.J.H.;Encica, L.;Meessen, K.J.;Lomonova, E.A.
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • v.2 no.3
    • /
    • pp.275-282
    • /
    • 2013
  • Applications such as vibration isolation, gravity compensation, pick-and-place machines, etc., would benefit from (long-stroke) cylindrical/tubular permanent magnet (PM) actuators with integrated passive gravity compensation to minimize the power consumption. As an example, in component placing (pick-and-place) machines on printed circuit boards, passive devices allow the powerless counteraction of translator including nozzles or tooling bits. In these applications, an increasing demand is arising for high-speed actuation with high precision and bandwidth capability mainly due to the placement head being at the foundation of the motion chain, hence, a large mass of this device will result in high force/power requirements for the driving mechanism (i.e. an H-bridge with three linear permanent magnet motors placed in an H-configuration). This paper investigates a tubular actuator topology combined with passive gravity compensation. These two functionalities are separately introduced, where the combination is verified using comprehensive three dimensional (3D) finite element analyses.

Nonlinear analysis and design of concrete-filled dual steel tubular columns under axial loading

  • Wan, Cheng-Yong;Zha, Xiao-Xiong
    • Steel and Composite Structures
    • /
    • v.20 no.3
    • /
    • pp.571-597
    • /
    • 2016
  • A new unified design formula for calculating the composite compressive strength of the axially loaded circular concrete filled double steel tubular (CFDST) short and slender columns is presented in this paper. The formula is obtained from the analytic solution by using the limit equilibrium theory, the cylinder theory and the "Unified theory" under axial compression. Furthermore, the stability factor of CFDST slender columns is derived on the basis of the Perry-Robertson formula. This paper also reports the results of experiments and finite element analysis carried out on concrete filled double steel tubular columns, where the tested specimens include short and slender columns with different steel ratio and yield strength of inner tube; a new constitutive model for the concrete confined by both the outer and inner steel tube is proposed and incorporated in the finite element model developed. The comparisons among the finite element results, experimental results, and theoretical predictions show a good agreement in predicting the behavior and strength of the concrete filled steel tubular (CFST) columns with or without inner steel tubes. An important characteristic of the new formulas is that they provide a unified formulation for both the plain CFST and CFDST columns relating to the compressive strength or the stability bearing capacity and a set of design parameters.

A Study on Thermal Performance of Heat Pipes with Different Condenser Shape for Evacuated Tubular Solar Collector (태양열 집열기용 히트파이프 응축부 형상 변화에 따른 열성능 연구)

  • Kwak, Hee-Youl;Joo, Hong-Jin
    • Journal of the Korean Solar Energy Society
    • /
    • v.28 no.2
    • /
    • pp.28-33
    • /
    • 2008
  • The purpose of this study was experimentally to investigate thermal performance of heat pipe for evacuated tubular solar collector. Two sets of evacuated tubular solar collector with different condenser shape of heat pipe were prepared. The experiments were performed under the same operating condition with an indoor testing apparatus. Also, the experiments were carried out various testing conditions including inclination, flow rate, and incident heat flux. The results of thermal performance of collector with enlarged condenser showed that $F_R({\tau}{\alpha})$ was 0.6572 and $F_RU_L$ was -2.0086 at $40^{\circ}$. And the results of thermal performance of collector with straight condenser showed that $F_R({\tau}{\alpha})$ was 0.6233 and $F_RU_L$ was -1.4996 at the same inclined angle.

A Study for the Use of Solar Energy for Agricultural Industry - Solar Drying System Using Evacuated Tubular Solar Collector and Auxiliary Heater -

  • Lee, Gwi Hyun
    • Journal of Biosystems Engineering
    • /
    • v.38 no.1
    • /
    • pp.41-47
    • /
    • 2013
  • Purpose: The objectives of this study were to construct the solar drying system with evacuated tubular solar collector and to investigate its performance in comparison with indoor and outdoor dryings. Methods: Solar drying system was constructed with using CPC (compound parabolic concentrator) evacuated tubular solar collector. Solar drying system is mainly composed of evacuated tubular solar collector with CPC reflector, storage tank, water-to-air heat exchanger, auxiliary heater, and drying chamber. Performance test of solar drying system was conducted with drying of agricultural products such as sliced radish, potato, carrot, and oyster mushroom. Drying characteristics of agricultural products in solar drying system were compared with those of indoor and outdoor ones. Results: Solar drying system showed considerable effect on reducing the half drying time for all drying samples. However, outdoor drying was more effective than indoor drying on shortening the half drying time for all of drying samples. Solar drying system and outdoor drying for oyster mushroom showed the same half drying time. Conclusions: Oyster mushroom could be dried easily under outdoor drying until MR (Moisture Ratio) was reached to about 0.2. However, solar drying system showed great effect on drying for most samples compared with indoor and outdoor dryings, when MR was less than 0.5.

An Experimental Study on the Effects of Hyperthermia and Irradiation on the Rat's Kidney (방사선조사와 온열요법이 백서신에 미치는 조직 변화에 관한 실험적 연구)

  • Yoo, Myung-Hee;Lee, Kyung-Ja;Rhee, Chung-Sik
    • Radiation Oncology Journal
    • /
    • v.7 no.2
    • /
    • pp.157-169
    • /
    • 1989
  • Radiological and clinical evidences indicate that hyperthermia combined with irradiation produce a significant improvement in therapeutic effect of cancer The experiences obtained from 90 rats' kidney A single dose of irradiation ranged from 6Gy, 8Gy and 10Gy was delivered on the rat's kidney. The combined therapy group had the same irradiation after hyperthermia at $42\~44^{\circ}C$ for 30 minutes. Microscopic examination and calculation of thermal enhancement ratio were carried out, and the results were as follows: 1. In the group of hyperthermia alone, there were moderate glomerular congestion and mild tubular degeneration on light microscopic examination. 2. In the group of irradiation alone, tubular degeneration was noted in 6Gy irradiation and its severity was increased along with radiation dose. 3. In the group of hyperthermia combined with irradiation, tubular degeneration and necrosis were appeared in 6Gy and 10Gy irradiation, respectively. 4. On electron microscopic examination, proximal convoluted tubular and glomerular changes in irradiation group were similar to that of combined with hyperthermia, and its severity was increased along with observation periods. 5. Thermal enhancement ratio (TER) was 1.0 after evaluation of histipathologic changes in rat's kidney, with combination therapy.

  • PDF

A Pediatric Case of Long-term Untreated Distal Renal Tubular Acidosis

  • Kedsatha, Philavanh;Shin, Hee Young;Choi, Yong;Cheong, Hae Il;Cho, Tae-Joon;Yi, Eunsang;Maisai, Mayfong
    • Childhood Kidney Diseases
    • /
    • v.24 no.2
    • /
    • pp.115-119
    • /
    • 2020
  • Distal renal tubular acidosis (dRTA) is a rare renal tubular disorder characterized by normal anion gap metabolic acidosis, hypokalemia, and high urine pH. It can be inherited or acquired. In untreated pediatric patients with dRTA, rickets and growth retardation are common. We report the case of a 12-year-old Lao girl who presented with typical clinical features of dRTA with severe bone deformities that developed after a bed-ridden state due to a bicycle accident at the age of 8 years. Initial laboratory tests revealed metabolic acidosis with a normal anion gap, hypokalemia, and alkali urine. Renal ultrasonography revealed bilateral medullary nephrocalcinosis. Whole exome sequencing revealed no pathogenic mutations. After treatment with oral alkali, potassium, and vitamin D, she could walk and run. Later, she underwent corrective orthopedic surgeries for bony deformities. Thus, in pediatric dRTA patients, despite severe symptoms remaining untreated, accurate diagnosis and proper management can improve quality of life.

Experimental study on innovative tubular web RBS connections in steel MRFs with typical shallow beams

  • Saleh, Aboozar;Zahrai, Seyed M.;Mirghaderi, Seyed R.
    • Structural Engineering and Mechanics
    • /
    • v.57 no.5
    • /
    • pp.785-808
    • /
    • 2016
  • An innovative Reduced Beam Section (RBS) connection, called Tubular Web RBS connection (TW-RBS), has been recently introduced and its performance has been numerically investigated in some earlier studies. The TW-RBS connection is a kind of accordion-web RBS connection in which part of the flat web of the beam is replaced by a steel tube at the expected region of the plastic hinge. This paper presents experimental results of three TW-RBS connections under cyclic loading. Obtained results indicated that TW-RBS reduces contribution of the beam web to the whole moment strength and creates a ductile fuse far from components of the beam-to-column connection. Besides, TW-RBS connection can increase story drift capacity up to 9% in the case of shallow beams which is much more than those stipulated by the current seismic codes. Based on the experimental results, the tubular web in the plastic hinge region improves lateral-torsional buckling stability of the beam such that only local buckling of the beam flange at the center of the reduced section was observed during the tests. In order to achieve a better understanding, behavior of all TW-RBS specimens are also numerically investigated and compared with those of experimental results.

Adult Idiopathic Renal Fanconi Syndrome: A Case Report

  • Park, Dae Jin;Jang, Ki-Seok;Kim, Gheun-Ho
    • Electrolytes & blood pressure
    • /
    • v.16 no.2
    • /
    • pp.19-22
    • /
    • 2018
  • Renal Fanconi syndrome (RFS) is caused by generalized proximal tubular dysfunction and can be divided into hereditary and acquired form. Adult-onset RFS is usually associated with drug toxicity or systemic disorders, and modern molecular genetics may explain the etiology of previous idiopathic cases of RFS. Here, we report the case of a 52-year-old woman with RFS whose etiology could not be identified. She presented with features of phosphaturia, renal glucosuria, aminoaciduria, tubular proteinuria, and proximal renal tubular acidosis. Her family history was unremarkable, and previous medications were nonspecific. Her bone mineral density was compatible with osteoporosis, serum intact parathyroid hormone level was mildly elevated, and 25(OH) vitamin D level was insufficient. Her blood urea nitrogen and serum creatinine levels were 8.4 and 1.19 mg/dL, respectively (estimated glomerular filtration rate, $53mL/min/1.73m^2$). Percutaneous renal biopsy was performed but revealed no specific renal pathology, including mitochondrial morphology. No mutation was detected in EHHADH gene. We propose the possibility of involvement of other genes or molecules in this case of adult RFS.