• Title/Summary/Keyword: Tubes

Search Result 3,108, Processing Time 0.026 seconds

Life Analysis of Flexible Tubes Fitting for Pneumatic system (공기압용 관연결 피팅의 수명 분석)

  • Kang, Bo-Sik;Song, Joo-Sub;Yoo, Yung-Chul;Kim, Hyoung-Eui
    • Proceedings of the KSME Conference
    • /
    • 2007.05a
    • /
    • pp.1842-1847
    • /
    • 2007
  • In this study, we are to analyze the life and the main failure mode of flexible tubes fitting for pneumatic that are usually applied in the factory automation line. Flexible tubes fitting for pneumatic have complicated failure cause because they are organized as a complex of various elements. Therefore, in this paper, we analyzed the main failure mode of flexible tubes fitting for pneumatic, and then performed life test and performance test according to the international standards. On the basis of these processes, we estimate shape parameter that is the main factor for the calculation of test time for the reliability of flexible tubes fitting for pneumatic and their data analysis of life distribution.

  • PDF

Mechanical behavior and buckling failure of sharp-notched circular tubes under cyclic bending

  • Lee, Kuo-Long
    • Structural Engineering and Mechanics
    • /
    • v.34 no.3
    • /
    • pp.367-376
    • /
    • 2010
  • In this paper, an experimental investigation of the mechanical behavior and buckling failure of sharp-notched circular tubes subjected to cyclic bending is discussed. The unnotched and sharp-notched circular tubes of SUS 304 stainless steel were tested under symmetric curvature-controlled cyclic bending. It was found from moment-curvature curves that the loops show cyclic hardening and gradually steady after a few cycles for all tested tubes. The ovalization-curvature curves show an unsymmetric, ratcheting and increasing manner with the number of cycles. In addition, it was found that six almost parallel lines corresponding to unnotched and five different notch-depth (0.2, 0.4, 0.6, 0.8 and 1.0 mm) tubes were noted from the experimental relationship between the cyclic controlled curvature and the number of cycles necessary to produce buckling on a log-log scale. An empirical formulation was proposed so that it could be used for simulating the aforementioned relationship. By comparing with the experimental finding, the simulation was in good agreement with the experimental data.

Experiments on Single Phase Cooling Heat Transfer and Pressure Drop Characteristics in Microfin Tubes (마이크로휜관 내 단상 냉각 유동 열전달 및 압력 강하 특성에 관한 실험적 연구)

  • 이규정;한동혁
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.14 no.3
    • /
    • pp.231-239
    • /
    • 2002
  • Experiments on the single phase cooling heat transfer and pressure drop with microfin tubes were performed using water as a test fluid. Experimental data were obtained in the range of Reynolds number 3000 ~40000 and Prandtl number 4-6. The data of microfin tubes presented the characteristics of rough surface tube in pressure drop and heat transfer Experimental data were compared with the heat transfer and friction factor correlations of smooth tubes. Heat transfer enhancements of microfin tubes were lower than pressure drop penalty factors. The helix angle is more significant parameter in both of the pressure drop and heat transfer than the relative roughness. The correlations of Nusselt number and friction factor were suggested for the tested microfin tubes. Maximum deviations between correlations and experimental data were within $\pm15$% for Nusselt number and $\pm10$% for friction factor.

Enhancement of thin film evaporation on low-fin tubes (낮은핀관의 액막 증발 촉진에 관한 연구)

  • 김내현
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.10 no.6
    • /
    • pp.674-682
    • /
    • 1998
  • In this study, thin film evaporation of water on low-fin tubes were experimentally investigated. Five low-fin tubes with different fin spacing and fin height were tested. Test range covered 0.146kg/ms $\leq$$\Gamma$$\leq$0.219kg/ms and 10㎾/$\m^2$$\leq$q $\leq$70㎾/$\m^2$. Saturation temperature was loot. Compared with the plain tube, low fin tubes enhanced the water film evaporation from 60% to 100%. Tubes with fin spacing smaller than 2mm and fin height higher than 1mm performed better than tubes with other fin configuration. However, when fin spacing was too small at high film flow or fin height was too high at low film flow, the performance decreased. The heat transfer coefficient slightly increased as the flow rate increased. Correlations are developed based on present data.

  • PDF

The Effect of Oxygen Flow Rates on the Electrical Resistivity of MgO Thin Films in AC-PDPs

  • Chou, Hong-Chieh;Kim, Sung-O;Chen, Kuang-Lang;Chen, Samuel;Lee, Chien-Pang;Hsu, Chien-Hsing;Chou, Kuo-Ching;Huang, Chih-Ming
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2006.08a
    • /
    • pp.383-386
    • /
    • 2006
  • Magnesium oxide thin films were deposited with different thickness and oxygen flow rates for investigating the effects of the electrical resistivity of MgO thin films in AC-PDPs. The surface roughness was characterized by AFM. It reveals that higher oxygen flow rate generates higher electrical resistivity of MgO thin films.

  • PDF

Improve The Contrast Ratio on 20.1' S-IPS TFT-LCD with Ion-Beam-Alignment Technology

  • Chen, Yu-Hsien;Liu, Shen-Fa;Li, Huai-An;Huang, I-Chen;Sun, Oliver;Jaw, Jyh-Hong
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2006.08a
    • /
    • pp.1605-1608
    • /
    • 2006
  • The contrast ratio, brightness, and uniformity of S-IPS panel, whose alignment process was employed by ion-beam-alignment (IBA) technology, were improved significantly compared with the convention rubbing's panel, because the light leakage has been reduced in dark state effectively. The IBA technology could generate a panel whose pretilt angle was stable and low after post-treatment process.

  • PDF

Inkjet Printed Color Filter for LCD TV Application

  • Lyu, Shau-Lin;Liu, Shen-Fa;Li, Huai-An;Hsu, Feng-Lin;Liu, Pei-Yu;Chen, Kun-Hong
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2005.07b
    • /
    • pp.922-925
    • /
    • 2005
  • Inkjet printing technology is a highly proprietary process. We have evaluated the possibility of using inkjet technique to prepare color filters. Product specification for TV application was used as a template to examine process capability. Technical aspects of ink composition, jetting ability, and surface interaction were discussed.

  • PDF

Burst Pressure Evaluation for Through-Wall Cracked Tubes in the Steam Generator (관통균열이 존재하는 증기발생기 전열관의 파열압력 평가)

  • Kim, Hyun-Su;Kim, Jong-Sung;Jin, Tae-Eun;Kim, Hong-Deok;Chung, Han-Sup
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.28 no.7
    • /
    • pp.1006-1013
    • /
    • 2004
  • Operating experience of steam generators shows that the tubes are degraded by stress corrosion cracking, fretting wear and so on. These defected tubes could stay in service if it is proved that the tubes have sufficient structural margin to preclude the risk of tube bursting. This paper provides detailed plastic limit pressure solutions for through-wall cracks in the steam generator tubes. These are developed based on three dimensional(3D) finite element analyses assuming elastic-perfectly plastic material behavior. Both axial and circumferential through-wall cracks in free span and in u-bend regions are considered. The resulting limit pressure solutions are given in a polynomial form, and thus can be simply used in practical integrity assessment of the steam generator tubes.

Calculation of the Quantum Efficiency of Phosphor Screens in CRTs and FL Tubes

  • Ozawa, Lyuji;Tian, Yakui
    • Journal of Information Display
    • /
    • v.11 no.3
    • /
    • pp.128-133
    • /
    • 2010
  • The quantum efficiencies of CRT and FL tubes that use a phosphor screen as transducer of invisible particles to light in visible spectrum wavelengths were calculated in this study. The phosphor screens in CRT tubes have quantum efficiencies greater than 3,000, which give the luminance of comfortable images on phosphor devices for the observation by the eyes. The established FL tubes have the amazing quantum efficiency of $3{\times}10^{10}$ photons per moving electron per FL tube, which allows the illumination of a $5{\times}5\;m^2$ room by three FL tubes, with heating at $40^{\circ}C$. Thus, FL tubes, including for backlighting of LCD displays, have a superior over other illumination sources.

Numerical Analysis of Hydrodynamic mass for various Tube Arrays in a circular cylindrical shell (원통 내부의 전열관 배열에 따른 유체부가질량특성 수치해석)

  • Yang, Keum-Hee;Ryu, Ki-Wahn;Park, Chi-Yong
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2011.04a
    • /
    • pp.693-699
    • /
    • 2011
  • The outermost SG tubes have more structural problems than inside tubes. Many studies have used a uniform added mass coefficient for all of the SG tubes during the FIV analysis. The purpose of this study is to find out the added mass coefficients for each tube in a cylindrical shell. When a number of tubes are increased, added mass coefficients are also increased. And added mass coefficients at outermost tubes are less than those of inside tubes. According to gap changes between outermost tube and cylindrical shell, added mass coefficients are decreased with increasing the gap. When the gap has very large value, it shows that the added mass coefficient is asymptotically converged to the value of the tube array in a free fluid field.

  • PDF