• Title/Summary/Keyword: Tubes

Search Result 3,118, Processing Time 0.031 seconds

The Research of RGB Photo Resistant In the Ink-Jet System

  • Huang, Chi-Yuan;Liu, Chia-I;Tsao, Keng-Yu;Kuo, Ju-Chien;Wu, Jing-Yi;Lo, Yu-Cheng;Liu, Pei-Yu;Wang, Jiun-Ming;Li, Huai-An
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2007.08b
    • /
    • pp.1583-1585
    • /
    • 2007
  • The purpose of this research is to control proper processing condition of RGB photo resistant in the ink-jet process increasing processing ability by adding additives. The viscosities of modified RGB photo resistant were $10{\sim}14cps$ and the additives could decreased agglomeration and flowing trace of photo resistant effectively. Another way, the adhesion between photo resistant and glass substrate was improved by modifying photo resistant and substrate. The surface tensions of modified photo resistant were same as that of original RGB photo resistant. The additives appeared a better compatibility with photo resistant, and the micelle of photo resistant did not be broken during modified process.

  • PDF

Taxonomic Study of Marine Nematodes from the Philippines I. Genus Tenuidraconema (Desmodorida: Draconematidae) (필리핀산 해양 선충류의 분류학적 연구 I. 가는도마뱀선충속 (Desmodorida목: 도마뱀선충과))

  • Rho Hyun Soo;Kim Won
    • Animal Systematics, Evolution and Diversity
    • /
    • v.21 no.1
    • /
    • pp.57-66
    • /
    • 2005
  • Tenuidraconema philippinensis, a new species of free-living marine nematode, collected from the shallow subtidal coarse sediments of the Philippines, is described. The new species differs from T. fiersi Decraemer, 1989 and T. koreensis Rho and Kim, 2004, by the following characteristics: the position of 12 cephalic adhesion tubes in both sexes (all 12 cephalic adhesion tubes inserted on the body annules), the number of posterior sublateral adhesion tubes (12 in male and 11 in female) and posterior subventral adhesion tubes (16 in male and 17 in female), and the absence of the intermingled somatic setae in male. This is the first discovery of the genus Tenuidraconema in the Philippines.

Convective heat transfer of MWCNT / HT-B Oil nanofluid inside micro-fin helical tubes under uniform wall temperature condition

  • Kazemia, M.H.;Akhavan-Behabadi, M.A.;Nasr, M.
    • Advances in nano research
    • /
    • v.2 no.2
    • /
    • pp.99-109
    • /
    • 2014
  • Experiments are performed to investigate the single-phase flow heat transfer augmentation of MWCNT/HT-B Oil in both smooth and micro-fin helical tubes with constant wall temperature. The tests in laminar regime were carried out in helical tubes with three curvature ratios of 2R/d=22.1, 26.3 and 30.4. Flow Reynolds number varied from 170 to 1800 resulting in laminar flow regime. The effect of some parameters such as the nanoparticles concentration, the dimensionless curvature radius (2R/d) and the Reynolds number on heat transfer was investigated for the laminar flow regime. The weight fraction of nanoparticles in base fluid was less than 0.4%. Within the applied range of Reynolds number, results indicated that for smooth helical tube the addition of nanoparticles to the base fluid enhanced heat transfer remarkably. However, compared to the smooth helical tube, the average heat transfer augmentation ratio for finned tube was small and about 17%. Also, by increasing the weight fraction of nanoparticles in micro-fin helical tubes, no substantial changes were observed in the rate of heat transfer enhancement.

Process Design for the Tubular Hydroforming at Elevated Temperatures (온간 하이드로포밍 공정을 위한 시스템 설계)

  • Kim, B.J.;Park, K.S.;Sohn, S.M.;Lee, M.Y.;Moon, Y.H.
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2006.05a
    • /
    • pp.226-229
    • /
    • 2006
  • Process design has been performed for the warm hydroforming of light weight alloy tubes. For the heating of tubes, specially designed induction heating system has been adopted to ensure rapid heating of tubes. The induction heating system uses 30kHz frequency induction coil in order to concentrate the energy in the tube and prevent the energy loss. But the induced heat by the integrated heating system, consisting of induction coil, tube, pressure oil and dies, was normally not equally distributed over the length and circumference of the tube specimen, and consequent temperature distribution was non-uniform. So additional heating element has been inserted into the inside of the tube to maintain the forming temperature and reduce temperature drop due to heat loss to the molds. And for that heat loss, a heat insulation system has also been installed. The drop in flow stress at elevated temperatures results in lower internal pressure for hydroforming and lower clamping forces. The proposed warm hydroforming process has been successfully implemented when applying 6061 aluminum extruded tubes.

  • PDF

Luminous phosphor with modified surface composition and microwave treatment for plasma planar back light

  • Ting, Chu-Chi;Cheng, Hao-Ping;Hsieh, Yu-Heng;Sun, Oliver;Chen, San-Yuan;Lin, Chin-Ching;Kuo, Kuan-Ting;Lee, Shu-Ping
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2005.07b
    • /
    • pp.1534-1535
    • /
    • 2005
  • Highly luminescent efficiency phosphors have been successfully produced by surface modification and microwave irradiation treatment. The SEM image and XRD analysis reveal that the surface morphology of the white-light phosphors can be notably modified by microwave irradiation and exhibit with better crystalline property. The VUV PL spectra show that the microwave irradiation treatment can effectively enhance the luminescent efficiency by a factor of 1.5 times for intensity compared to that without microwave treatment. A further improvement in all visible emission can be made by modifying surface composition through MgO coating on the phosphor powder. These results demonstrate that such a simple approach can provide for improving luminescent efficiency of phosphors for the optoelectronic devices.

  • PDF

Condensation heat transfer coefficients of CFC-11 and its alternative refrigerants (CFC-11과 그 대체냉매의 응축 열전달 계수)

  • Joo, Jae-Kil;Cho, Seong-Joon;Jung, Dong-Soo;Kim, Chong-Bo
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.21 no.6
    • /
    • pp.830-840
    • /
    • 1997
  • In this study, condensation heat transfer coefficients(HTCs) of CFC-11, HCFC-123 and HCFC-141b are measured, which are used/or considered as working fluids in centrifugal chillers. The main objectives of this study are to measure and compare the HTCs of various refrigerants on plain and low fin tubes and also to find out the optimum fin density of the low fin tubes. To accomplish these goals, HTCs of three refrigerants are measured for the plain tube as well as 4 types of low fin tubes. All measurements are carried out at the vapor temperature of 39.deg. C with the wall temperature difference of 3 .deg. C ~ 8.deg. C. For all the refrigerants tested, a low fin tube of 28 fins per inch yielded the best performance among all the tubes tested. For the plain tube, the HTCs of CFC-11 and HCFC-141b were very similar and those of HCFC-123 were 10% lower than those of CFC-11.Thus, it can be concluded that HCFC-123 and HCFC-141b are acceptable as alternative refrigerants for CFC-11 from the view point of condensation heat transfer.

Experimental study for the pressure drop of R-22 and R-4O7C during the condensation in the micro-fin tubes (마이크로핀관내에서 R-22와 R-4O7C의 응축압력강하 특성에 관한 실험적 연구)

  • Roh, Geon-Sang
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.31 no.6
    • /
    • pp.715-722
    • /
    • 2007
  • Experiments were conducted for the investigation of pressure drop inside horizontal micro-fin tubes during the condensation of R-22 and ternary refrigerant. R-407C(HFC-32/125/134a 23/25/62 wt%) as a substitute of R-22. The condenser is a double-tube and counterflow type heat exchanger which is consisted with micro-fin tubes having 60 fins with a length of 4000mm, outer diameter of 9.53mm and fin height of 0.2mm. The mass velocity varied from 102.1 to $301.0kg/(m^2{\cdot}s)$ and inlet quality was fixed as 1.0. From the experimental results. the pressure drop for R-407C was considerably higher than that for R-22. The value of PF(penalty factor) for both of refrigerants was not bigger than the ratio of micro-fin tube area to smooth tube area. Based on the experimental data. correlation was Proposed for the prediction of frictional pressure drop during the condensation of R-22 and R-407C inside horizontal micro-fin tubes.

Flow Boiling Heat Transfer Characteristics of Liquid Nitrogen in Plain and Wire Coil Inserted Tubes (평활관 및 와이어코일을 삽입한 열전달촉진관에서 액체질소의 흐름비등열전달 특성)

  • Hwang Jee-Sang;Yun Rin;Kim Yongchan;Chung Jin Taek
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.29 no.8 s.239
    • /
    • pp.927-933
    • /
    • 2005
  • Boiling heat transfer characteristics of liquid nitrogen in a stainless steel plain tube and wire coil inserted tubes were investigated. The test tubes, which had an inner diameter of 10.6 m and a length of 1.65 m, were horizontally located. Five wire coils having different pitch and thickness were inserted into the plain tube. The pitches of the wire coils were 18.4, 27.6, and 36.8 m, and the thickness was 1.5, 2.0, and 2.5 mm respectively. Tests were conducted at a saturation temperature of $-191^{\circ}$, mass fluxes from 58 to 105 kg/$m^2s$, and heat fluxes from 22.5 to 32.7 kw/$m^2$. A direct heating method was used to apply heat to the test section. The boiling heat transfer coefficients of liquid nitrogen were represented as a function of vapor quality, which showed significant drop at the dryout vapor quality. The maximum heat transfer enhancement using the wire coil inserted tubes over the plain tube was $174\%$ for 'Wire 3' having a thickness of 2.5 mm and a pitch of 18.4 mm.

Influence of Surfactant on Mass Transfer of Vertical Absorber (수직관 흡수기의 물질전달에 미치는 계면활성제의 영향)

  • Kwon, Oh-Kyung;Yoon, Jung-In;Yun, Jae-Ho
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.27 no.5
    • /
    • pp.604-611
    • /
    • 2003
  • This study was concerned with the enhancement of mass transfer by surfactant added to the aqueous solution of LiBr. Different vertical inner tubes were tested with and without an additive of normal octyl alcohol. The test tubes were a bare tube, groove tube, corrugate tube and inserted spring tubes. The additive concentration of normal octyl alcohol as a surfactant is about 0.08mass%. The Sherwood number was measured as a function of film Reynolds number 20~200. The experimental results were compared with those which use no surfactant. The enhancement of mass transfer by Marangoni convection effect which was generated by addition of the surfactant is proved for each testing tube Especially, it is clarified that the tube with the spring has the highest enhancement effect. A correlation of the experimental mass transfer data for the bare, groove, corrugate and insert spring tubes results expressed as the form of Sh=cㆍ Re$_{f}$ $^{n}$ .

Energy Absorbing Control Characteristic of Al Thin-walled Tubes (AL 박육부재의 에너지 흡수 제어특성)

  • Yang, Yong-Jun;Yang, In-Young
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.17 no.1
    • /
    • pp.86-91
    • /
    • 2008
  • The structural members must be designed to control characteristics of energy absorption for protecting passengers in a car accident. Study on collapse characteristics of structural member is currently conducted in parallel with other studies on effective energy absorption capacity of structural members with diverse cross-sectional shapes and various materials. This study concerns the crashworthiness of the widely used vehicle structural members, square thin-walled tubes, which are excellent in the point of the energy absorption capacity. The absorbed energy, mean collapse load and deformation mode were analyzed for side member which absorbs most of the collision energy. To predict and control the energy absorption, controller is designed in consideration of its influence on height, thickness and width ration in this study. The absorbed energy and mean collapse load of square tubes were increased by $15{\sim}20%$ in using the controller, and energy absorbing capability of the specimen was slightly changed by change of the high controller's height.