• Title/Summary/Keyword: Tubes

Search Result 3,108, Processing Time 0.035 seconds

Technical and Clinical Considerations for Successful Management of Postoperative Bowel Perforation by Percutaneous Foley Catheter Placement (경피적 폴리 카테터 삽입을 이용하여 수술 후 장 누출을 성공적으로 관리하기 위한 기술적 및 임상적 요인들)

  • So young Cho;Jung Suk Oh;Hae Giu Lee;Byung Gil Choi
    • Journal of the Korean Society of Radiology
    • /
    • v.81 no.6
    • /
    • pp.1389-1396
    • /
    • 2020
  • Purpose The aim of this study was to analyze several technical and clinical factors associated with the successful management of postoperative leakage by percutaneous Foley catheter placement. Materials and Methods Thirty-two patients were included in this retrospective study. Postoperative gastrointestinal leakage was diagnosed by computed tomography (CT) and the patients underwent percutaneous Foley catheter placement into the leakage site through Jackson-Pratt tubes or imaging-guided methods. Clinical success was defined as successful Foley catheter removal without symptom recurrence within 1 week and the risk factors for clinical failure were analyzed. Results In all patients, percutaneous Foley catheter placement was successfully achieved without complications. Foley catheter was placed at a median of 10 days (range, 1-68) after the confirmation of leakage on CT. Clinical success was achieved in 26 of the 32 patients (81%). Systemic comorbidity (p < 0.001) and failed oral intake (p = 0.015) were the statistically significant risk factors for clinical failure. Conclusion Percutaneous Foley catheter placement can be considered an effective approach for the management of postoperative bowel leakage. The presence of systemic comorbidity and successful oral diet after Foley catheter placement are significant factors for successful clinical recovery.

Effects on Indoor Air Quality of Burning Chemicals (Scented Candles and Incense Sticks) (태우는 생활화학제품(향초와 인센스 스틱)의 사용이 실내 공기질에 미치는 영향)

  • Eun-Ah Park;Seungyeon Eo;Yerin Oh;Na-Youn Park;Myoungho Lee;Younglim Kho
    • Journal of Environmental Health Sciences
    • /
    • v.50 no.1
    • /
    • pp.36-42
    • /
    • 2024
  • Background: The use of scented candles and incense sticks, both of which are household products that are burned for indoor deodorization and calming effects, is increasing. Fine dust has been designated as a group 1 carcinogen by the International Agency for Research on Cancer. Volatile organic compounds (VOCs) affect air pollution and can cause diseases. Objectives: This study aims to determine the effect on indoor air quality by measuring PM2.5 and VOCs generated when burning scented candles and incense sticks. Methods: Scented candles and incense sticks were selected as household products to burn. As for the target sample, top-selling products (five types of scented candles, five types of incense sticks) were purchased online. The PM2.5 concentration according to time was measured immediately next to the sample and three meters away from each other in an enclosed space using a real-time aerosol photometer. VOCs were collected as samples under the same conditions using Tenax tubes and were quantitatively analyzed by TD-GC/MS. Results: In the case of scented candles, the concentration of PM2.5 did not increase during combustion and after being extinguished by placing a cover on the candle. For the incense sticks, the concentration of PM2.5 averaged 1,901.27 ㎍/m3. After burning scented candles and incense sticks, some VOCs concentrations were increased such as ethyl acetate and BTEX (benzene, toluene, ethylbenzene, xylene). Conclusions: Therefore, when using scented candles, extinguishment by placing a cover on the candle can be expected to reduce PM2.5. It is advisable to avoid using incense sticks because PM2.5 concentration increases from the start of combustion.

Distribution and Origin of Carbonate Sediments near Dok Island: Preliminary Study (독도주변 탄산염퇴적물의 분포와 성인: 예비조사 결과)

  • Woo, Kyug-Sik;Ji, Hyo-Seon;Kim, Lyoun;Jeon, Jin-A;Park, Jae-Suk;Park, Heung-Sik;Kim, Dong-Seon;Park, Chan-Hong
    • The Sea:JOURNAL OF THE KOREAN SOCIETY OF OCEANOGRAPHY
    • /
    • v.14 no.3
    • /
    • pp.171-180
    • /
    • 2009
  • Based on the constituent analysis of sediments near Dok Island, the origin and sedimentary facies were Investigated. The sediments are mainly from originated from volcanic and volcaniclastic rock fragments derived from Dok Island and carbonate sediments formed by a variety of shallow-dwelling organisms that secreted calcareous skeletons. Carbonate producers include mollusks (bivalves and gastropods), encrusting & branching bryozoans, encrusting & segmented red algae, worm tubes, barnacles, diatoms, sponge spicules and echinoderm fragments. The distribution and relative amount of these constituents are basically dependent upon water depth and grain size even though local variations can be observed within the same depth interval. Five sedimentary facies can be divided: nearshore facies (<20 m), neritic facies ($20{\sim}100m$), upper transitional facies ($100{\sim}200m$), lower transitional facies ($200{\sim}700m$), and hemipelagic facies (>700 m). The sediments that were sampled below the water depth of 2,000 m still contain a significant amount of carbonates (ca. $10{\sim}20%$), implying that the carbonate compensation depth in the East Sea may well exceed this water depth.

Transformation of Nitrogen Derived from Solid Piggery Manure in Soil under Aerobic or Anaerobic Incubation Condition (혐기(嫌氣) 및 호기조건하(好氣條件下)에서 토양처리(土壤處理)된 돈분(豚糞) 중(中) 질소형태변화(窒素形態變化))

  • Yun, Sun-Gang;Jung, Kwang-Yong;Yoo, Sun-Ho
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.26 no.2
    • /
    • pp.121-126
    • /
    • 1993
  • The behaviors of inorganic nitrogen derived from solid animal waste in soil has been received too much concern partly because nitrate which occurred from nitrification can act as a pollutant to soil and groundwater and partly because the loss of nitrogen from surface soil by downward movement of water is disadvantageous in the view of plant nutrient. This present study was conducted to get fundamental imformations on nitrogen behavior and to provide improved basical concepts on the management of animal waste. Fresh or fermented pig manure was mixed with a sandy loam soil in the ratio of 2:1(soil:pig manure), packed into test tube and incubated at $30^+/-1^{\circ}C$ for 8 weeks under aerobic- or anaerobic condition. Sample tubes were taken at the one week interval and analyzed on pH, the amount of $CH_4$ produced under anaerobic condition and inorganic nitrogen. The pH of soil treated with fresh pig manure under anaerobic condition was lowered by 1.87 unit compared to that of under aerobic condition, but at the treatment with fermented pig manure, pH change was very little between aerobic and anaerobic condition. The coefficients of regressional equations which were obtained from pH and incubation time were -0.114 in fresh pig manure and -0.089 in fermented pig manure, and the extent of pH decrease due to incubation was greater in fresh pig manure than that of fermented pig waste. No differences in the amounts of $CH_4$ produced under anaerobic condition between fresh and fermented pig manure was observed until 3 weeks of incubation, however, after that the amount of $CH_4$ produced in fresh pig manure was abruptly increased and cumulative amont of $CH_4$ was reached 8.6 mole/g. K values on $CH_4$ production in fresh and fermented pig manure was 0.211 mole/g/day and 0.046 mole/g/day, respectively, for 5 weeks from the 3rd to the 8th week. $NH_4-N$ concentration at aerobic condition with fresh pig manure treatment was lowered by passing time of incubation, but $NO_3-N$ concentration was elevated from 11.2 ppm at initial state to 67.3 ppm after incubation and this trend on $NH_4-N$, $NO_3-N$ concentration was very similar to the treatment of fermented pig manure. While $NH_4-N$ concentration under anaerobic condition was greatly increased. $NO_3-N$ concentartion was not only very low but also no great changes, that was ranged from 4 to 8 ppm.

  • PDF

Investigation of the Rice Plant Transfer and the Leaching Characteristics of Copper and Lead for the Stabilization Process with a Pilot Scale Test (논토양 안정화 현장 실증 시험을 통한 납, 구리의 용출 저감 및 벼로의 식물전이 특성 규명)

  • Lee, Ha-Jung;Lee, Min-Hee
    • Economic and Environmental Geology
    • /
    • v.45 no.3
    • /
    • pp.255-264
    • /
    • 2012
  • The stabilization using limestone ($CaCO_3$) and steel making slag as the immobilization amendments for Cu and Pb contaminated farmland soils was investigated by batch tests, continuous column experiments and the pilot scale feasibility study with 4 testing grounds at the contaminated site. From the results of batch experiment, the amendment with the mixture of 3% of limestone and 2% of steel making slag reduced more than 85% of Cu and Pb compared with the soil without amendment. The acryl column (1 m in length and 15 cm in diameter) equipped with valves, tubes and a sprinkler was used for the continuous column experiments. Without the amendment, the Pb concentration of the leachate from the column maintained higher than 0.1 mg/L (groundwater tolerance limit). However, the amendment with 3% limestone and 2% steel making slag reduced more than 60% of Pb leaching concentration within 1 year and the Pb concentration of leachate maintained below 0.04 mg/L. For the testing ground without the amendment, the Pb and Cu concentrations of soil water after 60 days incubation were 0.38 mg/L and 0.69 mg/l, respectively, suggesting that the continuous leaching of Cu and Pb may occur from the site. For the testing ground amended with mixture of 3% of limestone + 2% of steel making slag, no water soluble Pb and Cu were detected after 20 days incubation. For all testing grounds, the ratio of Pb and Cu transfer to plant showed as following: root > leaves(including stem) > rice grain. The amendment with limestone and steel making slag reduced more than 75% Pb and Cu transfer to plant comparing with no amendment. The results of this study showed that the amendment with mixture of limestone and steel making slag decreases not only the leaching of heavy metals but also the plant transfer from the soil.

Anaerobic Organic Wastewater Treatment and Energy Regeneration by Utilizing E-PFR System (E-PER 반응기를 이용한 유기성 폐기물의 혐기성 처리와 재생에너지 생산에 관한 연구)

  • Kim, Burmshik;Choi, Hong-Bok;Lee, Jae-Ki;Park, Joo Hyung;Ji, Duk Gi;Choi, Eun-Ju
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.16 no.2
    • /
    • pp.57-65
    • /
    • 2008
  • Wastewater containing strong organic matter is very difficult to treat by utilizing general sewage treatment plant. but the wastewater is adequate to generate biomass energy (bio-gas; methane gas) by utilizing anaerobic digestion. EcoDays Plug Flow Reactor (E-PFR), which was already proved as an excellent aerobic wastewater treatment reactor, was adapted for anaerobic food wastewater digestion. This research was performed to improve the efficiency of bio-gas production and to optimize anaerobic wastewater treatment system. Food wastewater from N food waste treatment plant was applied for the pilot scale experiments. The results indicated that the efficiency of anaerobic wastewater treatment and the volume of bio-gas were increased by applying E-PFR to anaerobic digestion. The structural characteristics of E-PFR can cause the high efficiency of anaerobic treatment processes. The unique structure of E-PFR is a diaphragm dividing vertical hydraulic multi-stages and the inversely protruded fluid transfer tubes on each diaphragm. The unique structure of E-PFR can make gas hold-up space at the top part of each stage in the reactor. Also, E-PFR can contain relatively high MLSS concentration in lower stage by vertical up-flow of wastewater. This hydraulic flow can cause high buffering capacity against shock load from the wastewater in the reactor, resulting in stable pH (7.0~8.0), relatively higher wastewater treatment efficiency, and larger volume of bio-gas generation. In addition, relatively longer solid retention time (SRT) in the reactor can increase organic matter degradation and bio-gas production efficiency. These characteristics in the reactor can be regarded as "ideal" anaerobic wastewater treatment conditions. Anaerobic wastewater treatment plant design factor can be assessed for having 70 % of methane gas content, and better bio-gas yielding and stable treatment efficiency based on the results of this research. For example, inner circulation with generated bio-gas in the reactor and better mixing conditions by improving fluid transfer tube structure can be used for achieving better bio-gas yielding efficiency. This research results can be used for acquiring better improved regenerated energy system.

  • PDF

Improvement of Seed Germination in a Spontaneous Autotetraploid of Poncirus and Chlorophyll Fluorescence of Seedlings in Salt Stress (동질 사배체 탱자의 종자 발아 증진과 염류 과잉에 따른 엽록소 형광 반응)

  • Chae, Chi Won;Yun, Su Hyun;Park, Jae Ho;Kim, Min Ju;Han, Seung Gab;Kang, Seok Beom;Koh, Sang Wook;Han, Sang Heon
    • Journal of Life Science
    • /
    • v.23 no.9
    • /
    • pp.1079-1087
    • /
    • 2013
  • Speed germination success and robust vegetative growth of citrus rootstock through improved sowing methods and fertilizer inputs offer the usage of root system for the citrus. The current study evaluated the influence of seed coat removal and different fertilizer concentrations on plant germination and plant growth of spontaneous rootstock siblings. Decoated and coated seeds of diploid and tetraploid plants were sown in tubes. Commercial fertilizer concentrations of 0, 2, 4, 6, 8 and $10g{\cdot}l^{-1}$ were added. The experimental layout followed a randomized block $2{\times}6$ factorial design (seed coat removal ${\times}$ fertilizer concentration) for each rootstock. Fertilizer concentrations were 0, 10, 20 and $30g{\cdot}l^{-1}$ of the fertilizer for the resistance of the strength on the salt level. The germination rate of seeds without testa sown in vitro was improved (67-80%) compared to that of nontreated seeds. The eventual tree height of the seeds without testa in the diploid group was increased due to higher fertilization compared to that in the nontreated group. The removal of seed testa promoted the seed germination of both diploid and tetraploid trifoliate orange and resulted in greater height. Their vegetative development was also increased due to the increased fertilization of the rootstock. The Fv/Fm value for the diploid plants was 0.4 and 0.8 for the tetraploid ones under salt stress after 11 days of treatment. The removal of seed testa may improve the seed germination of trifoliate orange. Tetraploid trifoliate orange appears to possess resistance to salt stress compared to the diploid variety.

An Alternative Perspective to Resolve Modelling Uncertainty in Reliability Analysis for D/t Limitation Models of CFST (CFST의 D/t 제한모델들에 대한 신뢰성해석에서 모델링불확실성을 해결하는 선택적 방법)

  • Han, Taek Hee;Kim, Jung Joong
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.28 no.4
    • /
    • pp.409-415
    • /
    • 2015
  • For the design of Concrete-Filled Steel Tube(CFST) columns, the outside diameter D to the steel tube thickness t ratio(D/t ratio) is limited to prevent the local buckling of steel tubes. Each design code proposes the respective model to compute the maximum D/t ratio using the yield strength of steel $f_y$ or $f_y$ and the elastic modulus of steel E. Considering the uncertainty in $f_y$ and E, the reliability index ${beta}$ for the local buckling of a CFST section can be calculated by formulating the limit state function including the maximum D/t models. The resulted ${beta}$ depends on the maximum D/t model used for the reliability analysis. This variability in reliability analysis is due to ambiguity in choosing computational models and it is called as "modelling uncertainty." This uncertainty can be considered as "non-specificity" of an epistemic uncertainty and modelled by constructing possibility distribution functions. In this study, three different computation models for the maximum D/t ratio are used to conduct reliability analyses for the local buckling of a CFST section and the reliability index ${beta}$ will be computed respectively. The "non-specific ${beta}s$" will be modelled by possibility distribution function and a metric, degree of confirmation, is measured from the possibility distribution function. It is shown that the degree of confirmation increases when ${beta}$ decreases. Conclusively, a new set of reliability indices associated with a degree of confirmation is determined and it is allowed to decide reliability index for the local buckling of a CFST section with an acceptable confirmation level.

Packaging Technology for the Optical Fiber Bragg Grating Multiplexed Sensors (광섬유 브래그 격자 다중화 센서 패키징 기술에 관한 연구)

  • Lee, Sang Mae
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.24 no.4
    • /
    • pp.23-29
    • /
    • 2017
  • The packaged optical fiber Bragg grating sensors which were networked by multiplexing the Bragg grating sensors with WDM technology were investigated in application for the structural health monitoring of the marine trestle structure transporting the ship. The optical fiber Bragg grating sensor was packaged in a cylindrical shape made of aluminum tubes. Furthermore, after the packaged optical fiber sensor was inserted in polymeric tube, the epoxy was filled inside the tube so that the sensor has resistance and durability against sea water. The packaged optical fiber sensor component was investigated under 0.2 MPa of hydraulic pressure and was found to be robust. The number and location of Bragg gratings attached at the trestle were determined where the trestle was subject to high displacement obtained by the finite element simulation. Strain of the part in the trestle being subjected to the maximum load was analyzed to be ${\sim}1000{\mu}{\varepsilon}$ and thus shift in Bragg wavelength of the sensor caused by the maximum load of the trestle was found to be ~1,200 pm. According to results of the finite element analysis, the Bragg wavelength spacings of the sensors were determined to have 3~5 nm without overlapping of grating wavelengths between sensors when the trestle was under loads and thus 50 of the grating sensors with each module consisting of 5 sensors could be networked within 150 nm optical window at 1550 nm wavelength of the Bragg wavelength interrogator. Shifts in Bragg wavelength of the 5 packaged optical fiber sensors attached at the mock trestle unit were well interrogated by the grating interrogator which used the optical fiber loop mirror, and the maximum strain rate was measured to be about $235.650{\mu}{\varepsilon}$. The modelling result of the sensor packaging and networking was in good agreements with experimental result each other.

Recent Progress in Air-Conditioning and Refrigeration Research : A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2016 (설비공학 분야의 최근 연구 동향 : 2016년 학회지 논문에 대한 종합적 고찰)

  • Lee, Dae-Young;Kim, Sa Ryang;Kim, Hyun-Jung;Kim, Dong-Seon;Park, Jun-Seok;Ihm, Pyeong Chan
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.29 no.6
    • /
    • pp.327-340
    • /
    • 2017
  • This article reviews the papers published in the Korean Journal of Air-Conditioning and Refrigeration Engineering during 2016. It is intended to understand the status of current research in the areas of heating, cooling, ventilation, sanitation, and indoor environments of buildings and plant facilities. Conclusions are as follows. (1) The research works on the thermal and fluid engineering have been reviewed as groups of flow, heat and mass transfer, the reduction of pollutant exhaust gas, cooling and heating, the renewable energy system and the flow around buildings. CFD schemes were used more for all research areas. (2) Research works on heat transfer area have been reviewed in the categories of heat transfer characteristics, pool boiling and condensing heat transfer and industrial heat exchangers. Researches on heat transfer characteristics included the results of the long-term performance variation of the plate-type enthalpy exchange element made of paper, design optimization of an extruded-type cooling structure for reducing the weight of LED street lights, and hot plate welding of thermoplastic elastomer packing. In the area of pool boiling and condensing, the heat transfer characteristics of a finned-tube heat exchanger in a PCM (phase change material) thermal energy storage system, influence of flow boiling heat transfer on fouling phenomenon in nanofluids, and PCM at the simultaneous charging and discharging condition were studied. In the area of industrial heat exchangers, one-dimensional flow network model and porous-media model, and R245fa in a plate-shell heat exchanger were studied. (3) Various studies were published in the categories of refrigeration cycle, alternative refrigeration/energy system, system control. In the refrigeration cycle category, subjects include mobile cold storage heat exchanger, compressor reliability, indirect refrigeration system with $CO_2$ as secondary fluid, heat pump for fuel-cell vehicle, heat recovery from hybrid drier and heat exchangers with two-port and flat tubes. In the alternative refrigeration/energy system category, subjects include membrane module for dehumidification refrigeration, desiccant-assisted low-temperature drying, regenerative evaporative cooler and ejector-assisted multi-stage evaporation. In the system control category, subjects include multi-refrigeration system control, emergency cooling of data center and variable-speed compressor control. (4) In building mechanical system research fields, fifteenth studies were reported for achieving effective design of the mechanical systems, and also for maximizing the energy efficiency of buildings. The topics of the studies included energy performance, HVAC system, ventilation, renewable energies, etc. Proposed designs, performance tests using numerical methods and experiments provide useful information and key data which could be help for improving the energy efficiency of the buildings. (5) The field of architectural environment was mostly focused on indoor environment and building energy. The main researches of indoor environment were related to the analyses of indoor thermal environments controlled by portable cooler, the effects of outdoor wind pressure in airflow at high-rise buildings, window air tightness related to the filling piece shapes, stack effect in core type's office building and the development of a movable drawer-type light shelf with adjustable depth of the reflector. The subjects of building energy were worked on the energy consumption analysis in office building, the prediction of exit air temperature of horizontal geothermal heat exchanger, LS-SVM based modeling of hot water supply load for district heating system, the energy saving effect of ERV system using night purge control method and the effect of strengthened insulation level to the building heating and cooling load.