• Title/Summary/Keyword: Tubes

Search Result 3,108, Processing Time 0.03 seconds

TOPSIS-Based Multi-Objective Shape Optimization for a CRT Funnel (TOPSIS 를 적용한 CRT 후면유리의 다중목적 형상최적설계)

  • Lee, Kwang-Ki;Han, Jeong-Woo;Han, Seung-Ho
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.35 no.7
    • /
    • pp.729-736
    • /
    • 2011
  • The technique for order preference by similarity to ideal solution (TOPSIS) is regarded as a classical method of multiple attribute decision making (MADM), often used to solve various decision-making or selection problems. It is based on the concept that the chosen alternative should have the shortest distance from the positive ideal solution and the farthest distance from the negative ideal solution. The TOPSIS can be applied to a design process for carrying out multi-objective shape optimization wherein the best and worst alternatives are to be decided. In this paper, multi-objective shape optimization using the TOPSIS and Rational Bezier curve was applied to the funnel of a cathode-ray tube (CRT). In order to minimize the weight and first principal stress, a new multi-objective shape optimization methodology is proposed, wherein the relative-closeness coefficients of the TOPSIS are defined as the performance indices of a multi-objective function and evaluated by response surface models. This methodology enables the designer to decide on the best solution from a number of design specification groups by examining the various conflicts between the weight and the first principal stress.

The Changing Patterns of Antibiotic Susceptibility for Acinetobacter baumannii in Pediatric Burn Patients (소아 화상환자에서 배양된 Acinetobacter baumannii에 대한 항생제 감수성 양상의 변화)

  • Lee, Sang-Min;Lee, So-Yeon;Kim, Young-Ho;Lee, Kyu-Man;Jang, Young-Chul;Kim, Kwang-Nam
    • Pediatric Infection and Vaccine
    • /
    • v.15 no.2
    • /
    • pp.146-151
    • /
    • 2008
  • Purpose : Multidrug-resistant Acinetobacter baumannii (A. baumannii) is recognized to be the most difficult pathogen to control and treat in pediatric burn centers. We analyzed the antibiotic susceptibility pattern of A. baumannii in our pediatric burn intensive care unit during the past 7 years. Methods : We retrospectively evaluated 56 patients (105 samples) under the age 15 years and who were infected with A. baumannii between January 1999 and December 2005. Results : Fot the 56 patients, the ratio of males to females was 1.15:1 and the median age was 48.3 months. The sites of 105 isolates were wounds (65%), sputum (20%), blood (6 %), cutdown tips (5%), endo-tip tubes (2%) and urine (2%). A. baumannii presented yearround. The annual antimicrobial resistance rate increased and the multidrug resistant rate for two or more antibiotics was 93.33%. For 3 patients in whom resistance emerged, the interval period between the susceptible and resistant strains after antibiotic use was a mean of 10 days. The A. baumannii isolated from blood were all multi-drug resistant pathogens. Conclusion : Multidrug resistance of A. baumannii is increasing. Strict infection control guidelines and active surveillance are needed for the prevention and treatment of A. baumannii in hospitals.

  • PDF

Development of Profile Technique for Steam Generator Tubes in Nuclear Power Plants Using $8{\times}1$ Multi-Array Eddy Current Probe ($8{\times}1$ 다중코일 와전류탐촉자를 이용한 원전 증기발생기 전열관 단면형상검사 기법 개발)

  • Nam, Min-Woo;Lee, Hee-Jong;Kim, Cheol-Gi
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.28 no.2
    • /
    • pp.184-190
    • /
    • 2008
  • Various ECT techniques have been applied basically to assess the integrity of steam generator tithing in nuclear power plant. Among these techniques, the bobbin probe technique is applied generally to examine the volumetric flaws such as a crack-like defect and wear which is generally occurred on steam generator tubing, and additionally MRPC probe is used to examine closely tile top of tubesheet and bending regions due to the high possibility of cracking. Dent and bulge also may be formed on tube during installation process and operation of steam generator, but the dent and bulge indications greater than specific size criteria are recorded on examination report because these indications are not considered as flaw. These indications can be easily detected with bobbin probe and approximately sized with profile bobbin probe, but the size and shape can not be accurately verified. Accordingly, in this study, the $8{\times}1$ multi-array EC probe was designed to increase the measurement accuracy of the sectional profiling EC testing of tube. As a result, we would like to propose the application of $8{\times}1$ multi-array EC probe for the measurement of size and shape of profile change on steam generator tube in OPR-1000 nuclear power plant.

Electrical Characteristics Measurement of Eddy Current Testing Instrument for Steam Generator in NPP (원전 증기발생기 와전류검사 장치의 전기적 특성 측정)

  • Lee, Hee-Jong;Cho, Chan-Hee;Yoo, Hyun-Joo;Moon, Gyoon-Young;Lee, Tae-Hun
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.33 no.5
    • /
    • pp.465-471
    • /
    • 2013
  • A steam generator in nuclear power plant is a heatexchager which is used to convert water into steam from heat produced in a nuclear reactor core, and the steam produced in steam generator is delivered to the turbine to generate electricity. Because of damage to steam generator tubing may impair its ability to adequately perform required safety functions in terms of both structural integrity and leakage integrity, eddy current testing is periodically performed to evaluate the integrity of tubes in steam generator. This assessment is normally performed during a reactor refueling outage. Currently, the eddy current testing for steam generator of nuclear power plant in Korea is performed in accordance with KEPIC & ASME Code requirements, the eddy current testing system is consists of remote data acquisition unit and data analysis program to evaluate the acquired data. The KEPIC & ASME Code require that the electrical properties of remote data acquisition unit, such as total harmonic distortion, input & output impedance, amplifier linearity & stability, phase linearity, bandwidth & demodulation filter response, analog-to-digital conversion, and channel crosstalk shall be measured in accordance with the KEPIC & ASME Code requirements. In this paper, the measurement requirements of electrical properties for eddy current testing instrument described in KEPIC & ASME Code are presented, and the measurement results of newly developed eddy current testing instrument by KHNP(Korea Hydro & Nuclear Power Co., LTD) are presented.

Preliminary Culture Evaluation of Newly Introduced Apios (Apios americana M.) (아피오스(Apios americana M.) 도입 생산을 위한 기초 연구)

  • Riu Key Zung;Kang Young Kil;Kang Bong Kyoon;Kim Dong Sub;Park In Sook;Song Hi Sup;Kang Si-Yong
    • Korean Journal of Plant Resources
    • /
    • v.18 no.3
    • /
    • pp.424-432
    • /
    • 2005
  • Newly introduced two lines of apios (Apios americana Medikus, red-vine and green-vine) were grown in Jeju island, to clarify their growth and production characteristics as well as to develope as a new edible crops in Korea. Both lines bloomed but did not develop to pod and seed. The red-viny line showed the habit of more early growth and maturity compared with green-viny line. Fresh tuber yields per 10a harvested in late November ranged from about 500kg to 800kg as according to the lines and cultural condition. Fresh tuber yield of red-viny line was relatively greater than that of green-viny line, mainly due to their higher tuber number per plant. Among the planting dates(April 1, April 16 and May 1) of seed tubes, highest tuber yield was obtained on May 16 planting. And the stacking cultivation culture was better than non-stacking cultivation in respect of tuber yield and disease avoidance. These results indicate that apios can produce in Jeju island, and in order to extend its cultivation to farmers it will be needed to develope some cultivars with high yields as well as labor-saving cultivation methods.

REPLACEMENT OF A PHOTOMULTIPLIER TUBE IN A 2-INCH THALLIUM-DOPED SODIUM IODIDE GAMMA SPECTROMETER WITH SILICON PHOTOMULTIPLIERS AND A LIGHT GUIDE

  • KIM, CHANKYU;KIM, HYOUNGTAEK;KIM, JONGYUL;LEE, CHAEHUN;YOO, HYUNJUN;KANG, DONG UK;CHO, MINSIK;KIM, MYUNG SOO;LEE, DAEHEE;KIM, YEWON;LIM, KYUNG TAEK;YANG, SHIYOUNG;CHO, GYUSEONG
    • Nuclear Engineering and Technology
    • /
    • v.47 no.4
    • /
    • pp.479-487
    • /
    • 2015
  • The thallium-doped sodium iodide [NaI(Tl)] scintillation detector is preferred as a gamma spectrometer in many fields because of its general advantages. A silicon photomultiplier (SiPM) has recently been developed and its application area has been expanded as an alternative to photomultiplier tubes (PMTs). It has merits such as a low operating voltage, compact size, cheap production cost, and magnetic resonance compatibility. In this study, an array of SiPMs is used to develop an NaI(Tl) gamma spectrometer. To maintain detection efficiency, a commercial NaI(Tl) $2^{\prime}{\times}2^{\prime}$ scintillator is used, and a light guide is used for the transport and collection of generated photons from the scintillator to the SiPMs without loss. The test light guides were fabricated with polymethyl methacrylate and reflective materials. The gamma spectrometer systems were set up and included light guides. Through a series of measurements, the characteristics of the light guides and the proposed gamma spectrometer were evaluated. Simulation of the light collection was accomplished using the DETECT 97 code (A. Levin, E. Hoskinson, and C. Moison, University of Michigan, USA) to analyze the measurement results. The system, which included SiPMs and the light guide, achieved 14.11% full width at half maximum energy resolution at 662 keV.

A Study on Dynamic Moisture Transfer in Textiles Using Cobaltous Chloride Method (염화코발트법을 이용한 직물의 동적 수분전달에 대한 연구)

  • Hong Kyunghi;Kim Eunsook
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.13 no.4
    • /
    • pp.400-411
    • /
    • 1989
  • Moisture related properties of fabrics in dynamic modes are considered to be important in the judgement of the subjective comfort characteristics of clothing fabrics. In the current study, an attempt to improve the cobaltous chloride test method was made which has been known as a convenient screening test for dynamic surface wetness. The color changes of cobaltous chloride treated fabrics on the simulated sweating skin were calibrated against standard color strips. The standard color strips were made of all typs of test fabrics and installed inside of the test tubes containing a series of saturated salt solutions, which gives more quantitative informations on dynamic moisture transfer Influences of fiber types and finishes on dynamic moisture transfer in textiles were studied using a single layer of fabric samples. Fiber types included $100\%$ cotton, C/P 50/50, C/P 35/65. Durable press and soil release finished cotton and C/P 50/50 fabrics were also included. There were significant fiber effects on the dynamic moisture transfer. The order of time taken to reach to the specified $\%$ RH was C/P 35/65$100\%$ cotton fabrics. It was possible to detect significant finish effects by increasing the concentrations of cobaltous chloride solutions. The order of time taken to reach to the specified $\%$ R.H was durable press$100\%$ cotton, C/P 50/50, C/P 35/65 and $100\%$ PET were placed at the inner side of the outer layer and tested. It was shown that cobaltous chloride treated $100\%$ cotton fabirc was easier to detect color changes than C/P blend fabic in the double layer experiments. By placing test sample under the cobaltous chloride treated cotton fabrics, it was able to detect the differences among the test samples, some of which were known to be difficult in padding with cobaltous chloride solutions. Besides, the double layer method would provide with the broader application of the cobaltous chloride method in !uture, since it is possible to test the dynamic moisture transfer of clothing as worn.

  • PDF

Estimation of the relationship between below-ground root and above-ground canopy development by measuring dynamic change of soil ammonium-N concentration in rice

  • Fushimi, Erina;Yoshida, Hiroe;Tokida, Takeshi;Nakagawa, Hiroshi
    • Proceedings of the Korean Society of Crop Science Conference
    • /
    • 2017.06a
    • /
    • pp.183-183
    • /
    • 2017
  • In the early part of rice growth, root volume primarily limits the amount of plant-accessible nitrogen (N). Therefore, knowledge of the root development is important for modeling N uptake of rice. The timing when the volume of rhizosphere cover the whole soil is also important to carry out timely top dressing. However, information about initial root expansion and associated N uptake is limited due to intrinsic technical difficulties in assessing below-ground processes. Some studies, however, showed a close relationship between below-ground root and above-ground leaf development, suggesting a possibility that above-ground attributes could serve as surrogates for the root processes. In this study, we investigated the relationship between below-ground and above-ground development of rice. Field experiments were conducted where we cultivated Koshihikari (a leading cultivar in Japan) for four different cropping schedules in 2012. In 2016, Gimbozu (HEG4) and three flowering time mutant lines of Gimbozu (X61 (se13), HS276 (ef7), DMG9 (se13, ef7)) were examined for a single season. Experiments were performed with three replications in a completely randomized design. We monitored ammonium-N concentration ([NH4+-N]) in soil solution by repeatedly taking samples from a porous tubing (10-cm long) vertically inserted at the most distant point from surrounding rice hills. Samples were taken in triplicate (= triplicate tubes) and every three days from transplanting in each experimental unit. For above-ground attributes, leaf area index (LAI) was measured in 2012, whereas soil coverage ratio was estimated by image processing in 2016. Results showed that [NH4+-N] increased gradually after transplanting and then rapidly decreased from a certain day. This distinct drop in [NH4+-N] informed us the timing at which the rice root system reached the point of porous tubing and thus essentially covered the whole soil volume. The LAI at the dropping point was about 0.43 regardless of the cropping schedules in 2012 experiment. In 2016, the coverage ratio at the N dropping point was within the range of 0.12 to 0.19 for four genotypes having different growth durations. In addition, the coverage ratios at seven weeks after the transplanting showed a good correspondence to LAI across the four genotypes. We therefore conclude that both LAI and coverage ratio may serve as robust indicators for root development and might be useful to estimate the timing when the root system fully cover the soil volume. Results obtained here will also contribute to develop models that can predict not only above-ground canopy development but also associated below-ground processes.

  • PDF

Preanalytical Stability of Adrenocorticotropic Hormone Depends on Time to Centrifugation (전혈에서 시간과 온도에 따른 Adrenocorticotropic Hormone의 안정성 평가)

  • Shin, Sun-Young;Lee, Hyun-Joo;Min, Gyung-Sun;Lee, Ho-Young
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.13 no.1
    • /
    • pp.116-119
    • /
    • 2009
  • Background: Preanalytical factors can affect reliability of hormone assay results. Adrenocorticotropic hormone (ACTH) in blood is considered highly unstable because of proteolytic degradation, so storage of blood samples on ice until analysis is recommended. In clinical practice, however, this procedure may present logistical problems because most samples for ACTH measurement must be shipped from the place of sample collection to the laboratory. Therefore, we studied the impact of time and temperature before plasma separation and analysis on the results of ACTH assays. Methods: A total number of 22 patients were enrolled in this study. We obtained 2 blood samples. ACTH concentrations were 35~126 pg/mL. ACTH concentrations were measured by immunoradiometric assay (IRMA) using commercial kits (CIS Biointernational, Gif-sur-Yvette, France). Results: ACTH levels showed a significant difference between the samples of $22^{\circ}C$ EDTA and $4^{\circ}C$ EDTA. Measured ACTH concentrations significantly decreased with time before freezing at $-20^{\circ}C$. ACTH levels showed no significant difference between the groups of after storage for 24 hr without centrifugation at $22^{\circ}C$ and $4^{\circ}C$. Conclusion: We recommend that blood samples be obtained on pre-chilled EDTA collection tubes. The shortest possible time between sample collection and processing is always the best laboratory practice.

  • PDF

Classification of Axis-symmetric Flaws with Non-Symmetric Cross-Sections using Simulated Eddy Current Testing Signals (모사 와전류 탐상신호를 이용한 비대칭 단면을 갖는 축대칭 결함의 형상분류)

  • Song, S.J.;Kim, C.H.;Shin, Y.K.;Lee, H.B.;Park, Y.W.;Yim, C.J.
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.21 no.5
    • /
    • pp.510-517
    • /
    • 2001
  • This paper describes an initial study for the application of eddy current pattern recognition approaches to more realistic flaw characterization in steam generator tubes. For this purpose, finite-element model-based theoretical eddy current testing (ECT) signals are simulated from 5 types of OD flaws with the variation in flaw size parameters and testing frequency. In addition, three kinds of software are developed for the convenience in the application of steps in pattern recognition approaches such as feature extraction feature selection and classification by probabilistic neural networks (PNNs). The cross point of the ECT signals simulated from flaws with non-symmetric cross-sections shows the deviation from the origin of the impedance plane. New features taking advantages of this phenomenon are added to complete the feature set with a total of 18 features. Then, classification with PNNs are performed based on this feature set. The PNN classifiers show high performance for the identification of symmetry in the cross-section of a flaw. However, they show very limited success in the interrogation of the sharpness of flaw tips.

  • PDF