• Title/Summary/Keyword: Tubes

Search Result 3,108, Processing Time 0.027 seconds

Effects of Body Position and Time after Feeding on Gastric Residuals in LBW Infants

  • Hwang, Sun-Kyung;Ju, Hyun-Ok;Kim, Young-Soon;Lee, Hwa-Za;Kim, Young-Hae
    • Journal of Korean Academy of Nursing
    • /
    • v.33 no.4
    • /
    • pp.488-494
    • /
    • 2003
  • Purpose. To examine the effects of body position and time after feeding on gastric residuals in low birth weight infants(LBW). Methods. A repeated measures design was conducted. Twenty LBW infants being fed via indwelling nasogastric tubes were randomly assigned to one of 5 different position orderings. In each position, gastric residuals were measured at 30, 60, 90, 120, 150, and 180 minutes after feeding. Results. In comparisons of gastric residuals with position and time, the main effects of position and time were statistically significant (F=5.038, p=0.001; F=429.763, p < 0.001, respectively), but the interaction between position and time was found not to be significant. In pairwise comparisons, the gastric residuals were more reduced in the right anterior oblique and prone positions compared with the left lateral position (p < 0.05) and the differences across time periods were significant (p < 0.001). Conclusions. The body position after feeding has a significant affect on gastric residuals over time in LBW infants. The right anterior oblique or prone position is recommended rather than left lateral position after feeding. Knowledge of the proper position and the pattern of gastric emptying over time after feeding may lead to the development of evidence-based nursing care.

A Study on the Scale of the Family Labridae(Pisces : Perciformes) from Korea (한국산(韓國産) 놀래기과(科) 어류(魚類)의 비늘형태에 관한 연구(硏究))

  • Kim, Yong-Uk;Koh, Jeong-Rack
    • Korean Journal of Ichthyology
    • /
    • v.6 no.2
    • /
    • pp.160-171
    • /
    • 1994
  • The lateral line scales of the Labridae fish are ellipse, pentagoanl, or hexagonal, but most of them are the hexagonal type. Those of Ciarrhilabrus temminckii, ellipse, Xyrichtys dea, Choerodon azurio, Semicossyphus reticulatus and Bodianus oxycephalus are pentagonal. The most complex species are Choerodon azurio which is pentagonal, but similar tohexagonal, and Pteragogus flagellifera which is hexagonal, but similar to pentagonal type. The sizes of sensory tubes for the Labroides dimidiatus and Cheilio inermis were larger than the other group and Xyrichtys dea had most narrow one. These varied sizes of sensory tube indicate that development of sensory tube is deeply connected with inhabitation.

  • PDF

Lift-Off Invariance Transformations for Electromagnetic Eddy Current Nondestructive Evaluation Signals (다양한 센서 측정 거리로부터 획득한 자기적 와전류 신호의 불변 변환 처리 기법)

  • Kim, Dae-Won
    • Journal of the Korean Magnetics Society
    • /
    • v.14 no.6
    • /
    • pp.207-212
    • /
    • 2004
  • Eddy current (EC) testing methods are widely used in a variety of applications including the inspection of steam generator tubes in nuclear power plants, aircraft parts and airframes. A key factor that affects the EC signal is lift-off which means the physical distance between a sensor and a specimen in the testing. In practice, it is difficult to keep track of the actual value of the lift -off during a specific experiment, simulation or testing in the field, which is essential for accurate interpretation of the signal to be used in the following steps. Hence it is necessary to have a scheme to render the EC signal invariant to the effects of lift-off in spite of the changes in the real world. This paper describes a new method for compensating EC signals for variations in lift-off by acquiring an invariance feature using a homomorphic operator and neural network techniques. The signals from various lift-offs are transformed to obtain a zero lift-off equivalent signal that can be subsequently used for defect characterization in the next step.

Investigation of the Effect of kV Combinations on Image Quality for Virtual Monochromatic Imaging Using Dual-Energy CT: A Phantom Study

  • Jeon, Pil-Hyun;Chung, Heejun;Kim, Daehong
    • Journal of Radiation Protection and Research
    • /
    • v.43 no.1
    • /
    • pp.1-9
    • /
    • 2018
  • Background: In this study, we investigate the image quality of virtual monochromatic images synthesized from dual-energy computed tomography (DECT) at voltages of 80/140 kV and 100/140 kV. Materials and Methods: Virtual monochromatic images of a phantom are synthesized from DECT scans from 40 to 70 keV in steps of 1 keV under the two combinations of tube voltages. The dose allocation of dual-energy (DE) scan is 50% for both low- and high-energy tubes. The virtual monochromatic images are compared to single-energy (SE) images at the same radiation dose. In the DE images, noise is reduced using the 100/140 kV scan at the optimal monochromatic energy. Virtual monochromatic images are reconstructed from 40 to 70 keV in 1-keV increments and analyzed using two quality indexes: noise and contrast-to-noise ratio (CNR). Results and Discussion: The DE scan mode with the 100/140 kV protocol achieved a better maximum CNR compared to the 80/140 kV protocol for various materials, except for adipose and brain. Image noise is reduced with the 100/140 kV protocol. The CNR values of DE with the 100/140 kV protocol is similar to or higher than that of SE at 120 kV at the same radiation dose. Furthermore, the maximum CNR with the 100/140 kV protocol is similar to or higher than that of the SE scan at 120 kV. Conclusion: It was found that the CNR achieved with the 100/140 kV protocol was better than that with the 80/140 kV protocol at optimal monochromatic energies. Virtual monochromatic imaging using the 100/140 kV protocol could be considered for application in breast, brain, lung, liver, and bone CT in accordance with the CNR results.

Radionuclide Tubal Function Test (방사핵을 이용한 난관기능검사)

  • Roh, T.S.;Kim, J.G.;Yoon, B.H.;Moon, S.Y.;Lee, J.Y.;Chang, Y.S.;Chung, J.K.
    • Clinical and Experimental Reproductive Medicine
    • /
    • v.14 no.1
    • /
    • pp.1-6
    • /
    • 1987
  • The Radionuclide test (RN test) using radioactively labelled human albumin microspheres was developed recently to evaluate the patency and functional capacity of the fallopian tubes. 57 infertile women underwent this procedure as a part of their infertility work up. The results of the radionuclide evaluation were compared with those of the hysterosalpingography (HSG) and further the surgical findings of the laparoscopy and laparotomy. In 64.9%(37/57) of the cases, there was complete agreement between radionuclide test (RN test), hysterosalpingography(HSG) and surgical findings. In comparison with surgical findings, RN test showed a complete agreement rate of 89.4%(51/57), a partial agreement rate of 5.3%(3/57) and no agreement rate of 5.3%(3/57), respectively. Likewise, HSG revealed a complete agreement rate of 80.7%(46/57), a partial agreement rate of 10.5%(6/57) and no agreement 8.8%(5/57), respectively. It would appear that as opposed to the traditional HSG, RN test may give a better understanding of the functional capacity of the tube and may prove a useful method before and after tubal surgery.

  • PDF

A Numerical Study of Flow Structure in Over-Expanded Rocket Nozzles

  • Yonezawa, Koichi;Yamashita, Yukinori;Tsujimoto, Yoshinobu;Watanabe, Yasuhide;Yokota, Kazuhiko
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2004.03a
    • /
    • pp.165-172
    • /
    • 2004
  • LE-7A is the main engine of the H-IIA launch vehicle. Under its development, the nozzle suffered from two troubles during startup and shutdown transients of the engine. One is a large side load, which damages the actuator of the nozzle, and the other is damage on regenerative cooling tubes due to high heat load. It has been considered that these problems are caused by a peculiar separation pattern called Restricted Shock Separation (RSS). RSS is observed in several rocket nozzles, for example, LE-7A nozzle, Vulcain nozzle and so on. Their contours are not conventional truncated perfect (TP) nozzle - LE-7A nozzle is a compressed truncated perfect (CTP) nozzle and Vulcain nozzle is a thrust optimized (TO) nozzle. Although it is believed that the occurrence of RSS is affected by the nozzle contour, the mechanisms are not clarified sufficiently yet. In the present paper, a parametric numerical study is carried out to investigate the mechanisms of the occurrence of RSS in CTP nozzles during startup transient. The results show that RSS is caused by the adverse pressure gradient downstream of the Mach disk. The adverse pressure gradient is caused by the interaction of the pressure wave and Mach disk. The method to avoid the occurrence of RSS is also examined. A small step inside the nozzle affects the position of the separation point and prevents RSS. The result shows that the possibility that RSS can be suppressed by controlling the position of the separation point.

  • PDF

Experimental Study on the Two-Stage Light-Gas Gun (2단 경가스총에 대한 실험적 연구)

  • Lee, Jung-Kuen;Lee, Jong-Sung;Kim, Heuy-Dong;Koo, Ja-Ye
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2010.05a
    • /
    • pp.345-348
    • /
    • 2010
  • Light gas guns have a large number of applications in various fields of engineering. A two-stage light gas gun can develop an extremely high pressure in a very short interval of time. This can be employed efficiently in the application of ultra-high pressure liquid jets. In general, the two-stage light gas gun is made up of a high pressure tube, a compression tube and a launch tube, each stage being separated by diaphragms. The first diaphragm is installed downstream of the high pressure tube and the second, downstream of the compression tube. In the present study, experiments are carried out to investigate the projectile velocity and pressure behavior in the tubes according to the pressure changes at diaphragm opening. It is found that the rupture pressure of the first diaphragm has a dominant influence on projectile velocity. It is also observed that at pressures greater than 14 bar, the pressure in the launch tube exceeds that in the compression tube.

  • PDF

Development of Respiration Sensors Using Plastic Optical Fiber for Respiratory Monitoring Inside MRI System

  • Yoo, Wook-Jae;Jang, Kyoung-Won;Seo, Jeong-Ki;Heo, Ji-Yeon;Moon, Jin-Soo;Park, Jang-Yeon;Lee, Bong-Soo
    • Journal of the Optical Society of Korea
    • /
    • v.14 no.3
    • /
    • pp.235-239
    • /
    • 2010
  • In this study, we have fabricated two types of non-invasive fiber-optic respiration sensors that can measure respiratory signals during magnetic resonance (MR) image acquisition. One is a nasal-cavity attached sensor that can measure the temperature variation of air-flow using a thermochromic pigment. The other is an abdomen attached sensor that can measure the abdominal circumference change using a sensing part composed of polymethyl-methacrylate (PMMA) tubes, a mirror and a spring. We have measured modulated light guided to detectors in the MRI control room via optical fibers due to the respiratory movements of the patient in the MR room, and the respiratory signals of the fiber-optic respiration sensors are compared with those of the BIOPAC$^{(R)}$ system. We have verified that respiratory signals can be obtained without deteriorating the MR image. It is anticipated that the proposed fiber-optic respiration sensors would be highly suitable for respiratory monitoring during surgical procedures performed inside an MRI system.

Cooling Heat Transfer Characteristics of $CO_2$ on Tube Geometry of Inclined Helical Coil Type Gas Coolers (경사진 헬리컬 코일형 가스냉각기의 관형상에 따른 $CO_2$ 냉각 열전달 특성)

  • Son, Chang-Hyo;Oh, Hoo-Kyu
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.19 no.9
    • /
    • pp.640-646
    • /
    • 2007
  • The cooling heat transfer coefficient of $CO_2$ (R-744) for tube and coil diameter (CD), inclined angle of tube and coil pitch of inclined helical coil type copper tubes were investigated experimentally. The main components of the refrigerant loop are a receiver, a variable-speed pump, a mass flow meter, a pre-heater and a inclined helical coil type gas cooler (test section). The test section consists of a smooth copper tube of 2.45 and 4.55 mm inner diameter (ID). The refrigerant mass flukes were varied from 200 to 800 [$kg/m^2s$] and the inlet pressures of gas cooler were 7.5 to 10.0 [MPa]. The heat transfer coefficients of $CO_2$ in inclined helical coil tube with 2.45 mm ID are $5{\sim}10.3%$ higher than those of 4.55 mm. The heat transfer coefficients of 41.35 mm CD are $8{\sim}32.4%$ higher than those of 26.75 mm CD. Comparison between $45^{\circ}\;and\;90^{\circ}$ of coil angle, the heat transfer coefficients of $45^{\circ}$ are higher than those of $90^{\circ}$. For coil pitch of gas cooler, the heat transfer coefficients of inclined helical coil gas cooler with coil pitch of 5 mm are similar to those of 10 and 15 mm.

Boiling Heat Transfer of Ammonia inside Horizontal Smooth Small Tube (수평미세관내 NH3 비등열전달 특성)

  • Choi, Kwang-Il;Oh, Jong-Taek
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.25 no.2
    • /
    • pp.101-108
    • /
    • 2013
  • This paper is presented an experimental study of flow boiling heat transfer characteristics of ammonia, and is focused on pressure gradient and heat transfer coefficient of the refrigerant flow inside horizontal small tube with inner diameter of 3.0 mm and length of 2000 mm. The direct heating method is applied for supplying heat to the refrigerant, where the test tube is uniformly heated by electric current. The local heat transfer coefficients were obtained over a heat flux range of 20 to $80kW/m^2$, a mass flux range of 50 to $500kg/m^2s$, a saturation temperature range of 0 to $10^{\circ}C$, and quality up to 1.0. The pressure drops increase with increasing mass flux and heat flux, and with decreasing saturation temperature. The heat transfer coefficients increase with increasing mass flux and saturation temperature in middle and high quality region. And the local heat transfer coefficient increase with increasing heat flux in low quality region. The heat transfer coefficient of the experimental result was compared with six existing heat transfer coefficient correlation. A new boiling heat transfer coefficient correlation based on the superposition model for ammonia in small tubes is developed average deviation of -0.17% and mean deviation of 10.85%.