An Experimental Study on Frost Generation Mechanism from Evaporator Tube in Air Conditioning System (공조용 열교환기 증발관에서의 서리 발생에 관한 메커니즘의 실험적 연구)

  • Park Sang-Kyun;Oh Cheal
    • Journal of Navigation and Port Research
    • /
    • v.30 no.1 s.107
    • /
    • pp.113-117
    • /
    • 2006
  • The object qf this experiment was the evaluation of the growth rate of frost layer conditioned by inlet air's velocity, temperature and relative humidity on the copper tube in evaporator. In this experiment, the inlet air's velocity were $0.3^m/_s,\;0.6^m/_s,\;0.9^m/_s,$ temperature were $15^{\circ}C,\;20^{\circ}C,\;25^{\circ}C$ and the variation of relative humidity was $70\%~90\%$. And the brine temperature flowing through the copper tubes was kept $-15{\circ}C$ because generally cooling temperature range is constantly $-15^{\circ}C$ in the heat exchanger for air conditioning system It was found that the amount of frost generation increased so that the relative humidity, velocity and temperature of supply air increased.

Study on Buckling Instability of Expansion Tube using Finite Element Method (유한요소법을 이용한 팽창튜브의 좌굴불안전성에 관한 연구)

  • Choi, Won-Mok;Kwon, Tae-Su;Jung, Hyun-Sung
    • Journal of the Korean Society for Railway
    • /
    • v.13 no.2
    • /
    • pp.147-151
    • /
    • 2010
  • Since the kinetic energy is dissipated through plastic deformation energy generated in expanding process of the tube by a die. In order to successfully absorb the kinetic energy there should be no buckling in the expansion tube during expanding process. The buckling instability of the expansion tubes is affected by the initial boundary conditions, tube thickness and length. In this study, the effects of the tube thickness except length and initial boundary condition on the buckling instability are studied using a finite element method. In addition, Analysis procedure for nonlinear post-buckling analysis of expansion tube is established. There are three kinds of finite element analysis procedures for buckling analysis of expansion tube, quasi-static analysis, linear buckling analysis and nonlinear post-buckling analysis. The effect of the geometry imperfections defined as linear superimposition of buckling modes is considered in the nonlinear post-buckling analysis. The results of finite element analysis indicate that the buckling load increase with increase of thickness of tube and geometry imperfection. Finial buckling shapes are changed with respect to the geometry imperfection.

Modal Characteristics of Control Element Assembly Shroud for Korean Standard Nuclear Power Plant(I) : Pre-Test Analysis (한국표준형 원자력발전소 제어봉집합체 보호구조물의 모우드 특성)

  • Jhung, Myung-Jo;Choi, Suhn;Song, Heuy-Gap;Park, Keun-Bae
    • Computational Structural Engineering
    • /
    • v.5 no.3
    • /
    • pp.105-112
    • /
    • 1992
  • The design of reactor internals requires the accurate vibration characteristics of each component for subsequent dynamic structural response analysis. For Korean standard nuclear power plant some modifications on the Control Element Assembly shroud from the reference design have been made. Since the shroud is complex in geometry having an array of vertical round tubes and webs in a square grid pattern, and being tied down by preloaded tie rods into position, it is planned to perform a vibration measurement program consisting of both experimental and analytical modal studies upon that component. To determine the proper test conditions, the pre-test analysis has been performed using the general purpose structural analysis program ANSYS. Also the effects of the number of master degrees of freedom, holes in the web and tie-rod preload on the natural frequencies are examined prior to the pre-test analysis. After decision of appropriate finite element model, frequency analysis and harmonic analysis are performed and ideas for the test conditions such as the number of measurement points, their locations, measurement frequency range and the excitation force level are determined.

  • PDF

Characterization of Volatile Organic Compounds(VOCs) Concentrations in Jinju (진주시 대기중 휘발성 유기화합물의 농도특성 기초조사)

  • Park, Jeong-Ho;Park, Hyung-Gun;Suh, Jeong-Min
    • Journal of Environmental Science International
    • /
    • v.22 no.1
    • /
    • pp.91-98
    • /
    • 2013
  • In order to study the seasonal patterns and possible origins of air concentrations of volatile organic compounds(VOC), measurements were taken with GC-MS at 3 sampling sites in Jinju for 12 months from Mar. 2010 to Feb. 2011. Atmospheric VOC are sampled on tubes containing solid adsorbents(Tenax TA) with a time resolution of 2hrs. Composition and concentration of VOC are analysed with a GC system equipped with thermal desorption apparatus(ATD). The most abundant compound appeared to be Toluene, Ethylbenzene and m,p-Xylene. The mean concentrations of Benzene were 0.20 ppb at GN site, 0.18 ppb at DA site, and 0.25 ppb at SP site, respectively. VOC concentration showed a strong seasonal variation, with higher concentrations during the spring and lower concentrations during the summer. The results showed that monthly fluctuations in measured VOC concentrations depended on variations in the strength of sources, as well as on photochemical activity and meteorological conditions. In Jinju, the total VOC emissions for 2009 were estimated to be 4,407 ton/year by Clean Air Policy Support System(CAPSS). It is shown that solvent use 57.5%(2,534 ton/yr), waste treatment and disposal 23.3%(1,025 ton/yr), and mobil source-road traffic 12.2%(537 ton/yr) are the most significant anthropogenic source.

Comparison on Usefulness of Sampling Methods of Indoles in Airs from Swine Facility by Tenax-TA and SPME

  • Yu, Mee-Seon;Lee, Jae-Chun;Yang, Sung-Bong;Kim, Doo-Hwan;Cho, Sung-Back;Whang, Ok-Wha
    • Journal of Environmental Science International
    • /
    • v.22 no.12
    • /
    • pp.1539-1549
    • /
    • 2013
  • The purpose of this study is to compare the sampling methods for monitoring indoles (phenol, p-cresol, indole and skatole) in airs of swine facility. As the collecting methods of indoles in air, Tenax-TA adsorption tube and solid phase microextraction (SPME) were examined. For the preparation of calibration curves of indoles concentrated in Tenax-TA, the standard indoles solutions were spiked in each of Tenax-TA tubes and thermally desorbed (ATD) into a gas chromatograph combined with mass detector (GC/MS). And for the preparation of calibration curves by SPME, indoles in the standard gaseous solution prepared by evaporating the aqueous solution that contained indoles into a polyester sampling bag were extracted with SPME fiber and subsequently analyzed by the GC/MS. Two sampling methods were evaluated for extracting indoles present in swine building environments. Results indicated that the SPME method using Polydimethylsiloxane/ Divinylbenzene (PDMS/DVB) fiber was more effective than Tenax-TA method in extracting indoles. The gas chromatographic analysis showed that the linearities of calibration curves and detection limits were useful for detection of indoles in swine airs. The field tests also showed that considerably different levels of indoles were present in various parts of the swine building.

In-Vitro Study of Urokinase Thrombolysis Following Stereotactic Aspiration of Intracerebral Hematoma

  • Son, Wonsoo;Park, Jaechan;Kang, Dong-Hun;Han, Young-Min;Choi, Yeon-Ju;Ohk, Boram
    • Journal of Korean Neurosurgical Society
    • /
    • v.63 no.3
    • /
    • pp.380-385
    • /
    • 2020
  • Objective : A consensus regarding the ideal regimen for urokinase (UK) thrombolysis subsequent to stereotactic spontaneous intracerebral hemorrhage aspiration has yet to be established. The purpose of this study is to evaluate the efficacy of UK thrombolysis relative to when the regimen is changed. Methods : Venous blood from 30 heathy volunteers was obtained for this in-vitro study. Various concentrations of UK solution were added to microcentrifuge tubes containing the clotted blood. The efficacy of UK thrombolysis was identified by checking the weight of lysed hematoma following various time intervals with different concentrations of UK solution. Group one, the "3×4" group involved four administrations every 3 hours over 12 hours, and group two, the "6×2" group involved two administrations every 6 hours over 12 hours. Results : More hematoma was lysed in the 3×4 group than the 6×2 group across all concentration levels (however, the differences were only significant between groups at the 500 and 1000 IU concentration levels, p<0.05). There were no significant differences of lysed hematoma among the various UK solution concentrations within groups. Conclusion : This study suggests that frequent administrations of UK thrombolysis may result in a greater degree of lysed hematoma in comparison to a higher concentration of UK.

Antioxidative Effectiveness of Terminalia chebula Rets Extracts (가자(Terminalia chebula Retz)추출물의 항산화 효과)

  • Jang, Sung Jun;Lee, Gee Dong;Kim, Jeong Sook;Yoon, Hyung Sik
    • Current Research on Agriculture and Life Sciences
    • /
    • v.10
    • /
    • pp.11-17
    • /
    • 1992
  • In this study, antioxidative effectiveness of BHA, BHT at 0.02%(w/w) was compared with those of separated free phenolic acid, ester form and insoluble bound phenolic acid which were extracted from 50 g of Terminalia chebula Retz by MeOH/aceton solvents. Antioxidative effectiveness was measured by peroxide values and TBA values for 7 days, storaging respective substrates and contrast tube at $45{\pm}1^{\circ}C$ for 35days. Laboratory tubes was added by BHA, BHT, separated free, soluble and insoluble phenolic acid extracts and peroxide value of contrast tube after 21 day storage were 60, 30, 14, 11, 100. On the other hand, at the same conditions, TBA values of each antioxidants were 0.150, 0.108, 0.105, 0.073, 0.078, 0.185. This results remarkably appeared antioxidative effectiveness in meal soybean oil substrates. Phenolic acid separated and identificated were p-coumaric acid, Ferulic acid, Phloroglucinol, Pyrogallol, Vanillic acid and Caffeic acid.

  • PDF

Performance Analysis of the Soft Ice-cream Maker Having Two Evaporators Operating at Different Temperatures (두개의 증발기가 장착된 소프트 아이스크림 제조기의 성능 해석)

  • Kim, Jeong-Sik;Kim, Nae-Hyun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.2
    • /
    • pp.517-522
    • /
    • 2013
  • Small size ice-cream maker has two evaporators having different evaporating temperatures of $4^{\circ}C$ and $-8^{\circ}C$. In such case, ice-cream maker system design becomes complicated because multiple capillary tubes affects one another. In this study, performance analysis was conducted for the soft ice-cream maker having two evaporators operating at different temperatures. The compressor was analyzed using efficiency models, the capillary tube was modeled assuming one-dimensional flow, the condenser and the evaporators were modeld based on UA-LMTD method. The refrigeration cycle simulation program was developed applying the enthalpy, pressure and mass balance on each component. Comparison of the test data with the simulated results for R404A revealed that evaporator temperatures of refrigerator and freezer agreed within $3^{\circ}C$.

Bending Capacity Evaluation of the Infilled Composite Beam with Semi-slim Closed Section (반슬림 폐단면 충전형 합성보의 휨성능 평가)

  • Lim, Hwan Taek;Choi, Byong Jeong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.3
    • /
    • pp.130-140
    • /
    • 2018
  • An AU-composite beam based on U-shaped steel beams and steel plate anchors of type A was developed. The composite beam reduced the height of the building floor and construction cost. In addition, it decreased the length of construction work, and improved the flexural strength and stiffness as a form of tubes. In this study, AU-composite beams were tested directly and their performance was evaluated through bending experiments. The strength of the specimens was increased initially by linear loads and reached a maximum strength due to destruction of the concrete slab. All of the experiments showed more than 85% of the maximum stress and performed gentle movement. In addition, there was good composite behavior with the steel plate anchor that had excellent composite effects and reached full strength until the maximum strength was reached. When the thickness of the steel plate was increase, the flexural stiffness and strength of the specimen were improved. Therefore, the flexural strength of AU-composite beams can be estimated using the flexural strength formula according to the KBC 2016.

Comparison of Heat Transfer Performance and Pressure Drop of Fin-Tube and Aluminum Heat Exchangers (핀-튜브 열교환기와 알루미늄 열교환기의 전열성능과 압력강하 특성비교)

  • Chang, Keun-Sun;Lee, Hyun-Su;Kim, Jae-Duck
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.10 no.2
    • /
    • pp.222-229
    • /
    • 2009
  • This study presents comparison of heat transfer and air side friction characteristics in a condenser condition of air conditioner between Louver fin-tube heat exchangers and aluminum parallel heat exchangers. All experiments are performed using an air-enthalpy type calorimeter, which is designed based on the method described in ASHRAE standards. The air velocities crossing the heat exchanger tubes are varied from 0.7 to 1.6 m/s with 0.3 m/s interval, maintaining air dry temperature and relative humidity at $20^{\circ}C$ and 60% respectively. Water temperature and flow rate inside the tube are $70^{\circ}C$ and 10 LPM, respectively. Experimental results show that the heat transfer performances of aluminum heat exchangers are 17-163% higher than those of Louver fin-tube heat exchangers based on the data per unit volume, mass, and heat transfer area, whereas air side pressure drops of aluminum heat exchangers are 19-81% lower.