• Title/Summary/Keyword: Tubes

Search Result 3,122, Processing Time 0.032 seconds

A Method for Determination of Nitrogen in Ruminant Feedstuffs and Products

  • Islam, M.R.;Ishida, M.;Ando, S.;Nishida, T.;Yamada, T.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.16 no.10
    • /
    • pp.1438-1442
    • /
    • 2003
  • A method for the determination of nitrogen in ruminant feedstuffs, products and excreta (e.g. milk and urine) using a spectrophotometer is developed, where samples processed for P determination are also used to determine N. Samples are digested with sulphuric acid and subsequently with hydrogen peroxide in Kjeldahl tubes. Digested solutions along with phenol and buffered alkaline hypochlorite reagents are incubated in a water bath at $37^{\circ}C$ for 30 min and presented in the spectrophotometer. The spectrophotometer set at 625 nm measures the concentration of N of each sample. Nitrogen in 261 of the samples was also determined by the classical Kjeldahl method in order to develop a relationship between N determined by the Kjeldahl method (Y) and the colorimetric method (X). The mean value of Y was as high as that of X (0.92 vs. 0.96; p>0.05). The colorimetric method predicted Kjeldahl N highly significantly (Y=0.985X-0.024, $R^2=0.993$, p<0.001; or more simply Y=0.974X, $R^2=0.993$, p<0.001). An analysis of regression found no difference (p>0.05; both t-test and F-test) between colorimetric (0.96% N) and adjusted (0.96% N) N. In comparison with the Kjeldahl method, the analytical capacity of N by colorimetric method increases greatly, where 200-300 determinations of N are possible in a working day. In addition, the system provides an opportunity to use not only the same digested solution for both N and P determination of a particular sample, but also uses the same spectrophotometer to assay both N and P. Therefore, the system may be attractive in situations where both elements of a sample are to be determined. In conclusion, the speed of N determination, low cost, efficient use of labour, time and reagents, fewer items of equipment, and the reduction of environmental pollution by reducing effluent and toxic elements are the advantages of this method of N determination.

Bruising in Slaughter Cattle and Its Relationship with Creatine Kinase Levels and Beef Quality as Affected by Animal Related Factors

  • Mpakama, T.;Chulayo, A.Y.;Muchenje, V.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.27 no.5
    • /
    • pp.717-725
    • /
    • 2014
  • The objective of the study was to determine the effects of animal related factors on bruising in slaughter cattle, creatine kinase (CK) and beef quality. Three hundred and twenty one cattle from three breeds (108 Bonsmara, 130 Beefmaster and 83 Brahman) were used in this study. The animals were grouped as follows: Group 1 (16 months old), Group 2 (18 months old) and Group 3 (24 months old). At exsanguinations, blood samples for CK determination were collected using disposable vacutainer tubes. Muscularis longissimus thoracis et lumborum (LTL) was collected 24 h after slaughter to determine the colour ($L^*$, $a^*$, and $b^*$) and ultimate pH ($pH_u$) of beef. Breed, sex and age had significant effects (p<0.05) on bruising score, CK levels and beef quality. Bonsmara breed had the highest (80%) bruising score percentage, CK ($705.3{\pm}80.57U/L$) and $pH_u$ ($6.3{\pm}0.05$) values while the Bonsmara had the highest $L^*$ ($24.8{\pm}0.78$) $a^*$ ($17.5{\pm}0.53$) and $b^*$ ($12.8{\pm}0.53$) values. Higher CK levels were also observed in winter compared to summer, spring and autumn respectively. Therefore, animal factors (sex, breed and animal age at slaughter) contribute to the development of bruises and have an effect on the levels of CK and meat quality. It was also concluded that there is no significant relationship between meat parameters (L,* $a^*$, and $b^*$) and CK levels.

Development of a Nuclear Steam Generator Tube Inspection/maintenance Robot

  • Shin, Ho-Cheol;Kim, Seung-Ho;Seo, Yong-Chil;Jung, Kyung-Min;Jung, Seung-Ho;Choi, Chang-Hwan
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2003.10a
    • /
    • pp.2508-2513
    • /
    • 2003
  • This paper presents a nuclear steam generator tube inspection/maintenance robot system. The robot assists in automatic non-destructive testing and the repair of nuclear steam generator tubes welded into a thick tube sheet that caps a hemispherical or quarter-sphere plenum which is a high-radiation area. For easy carriage and installation, the robot system consists of three separable parts: a manipulator, a water-chamber entering and leaving device for the manipulator and a manipulator base pose adjusting device. A software program to control and manage the robotic system has been developed on the NT based OS to increase the usability. The software program provides a robot installation function, a robot calibration function, a managing and arranging function for the eddy-current test, a real time 3-D graphic simulation function which offers remote reality to operators and so on. The image information acquired from the camera attached to the end-effecter is used to calibrate the end-effecter pose error and the time-delayed control algorithm is applied to calculate the optimal PID gain of the position controller. The developed robotic system has been tested in the Ulchin NPP type steam generator mockup in a laboratory.

  • PDF

Modal Characteristics of Control Element Assembly Shroud for Korean Standard Nuclear Power Plant(II : Test and Post-Test Analysis) (한국표준형 원자력발전소 제어봉집합체 보호구조물의 모우드 특성 II)

  • Jhung, Myung-Jo;Park, Keun-Bae;Song, Heuy-Gap;Choi, Suhn
    • Computational Structural Engineering
    • /
    • v.5 no.4
    • /
    • pp.93-102
    • /
    • 1992
  • The design of reactor internals requires the accurate vibration characteristics of each component for subsequent dynamic structural response analyses. For Korean standard nuclear power plant some modifications on the Control Element Assembly shroud from the reference design have been made, Since the shroud is complex in geometry having an array of vertical round tubes and webs in a square grid pattern, and being tied down by preloaded tie rods into position, it is planned to perform a vibration measurement program consisting of both experimental and analytical modal studies upon that component. The shroud modal testing was performed on the low frequency global survey to measure the first several modes. The analysis using the finite element model was also performed for the as-tested conditions. The natural frequencies and mode shapes from both test and analysis have been acquired and compared to be in good agreement. It is concluded that finite element model generated is good enough to be used in the design for the dynamic response analysis under various loading conditions.

  • PDF

A Study of Laboratory Facilities, Equipment and Expenses for Practice in a Four-year Nursing Schools (4년제 간호대학(과) 실습 비 및 실습기자재 표준안 개발을 위한 기초조사연구)

  • Shin, Kyung-Rim;Park, Kyung-Sook;Ahn, Yang-Heui;Chaung, Seung-Kyo;Suh, Yeon-Ok
    • Korean Journal of Adult Nursing
    • /
    • v.15 no.2
    • /
    • pp.305-315
    • /
    • 2003
  • Purpose: To describe the status of the laboratory facilities, equipment and expenses for practice in a four-year nursing schools and to analyze mandatory requirements for laboratory facilities and equipment. Method: A descriptive survey research design was used. The participants were 49 of the 4-year nursing schools across the nation. The data were collected by e-mail. The return rate for questionnaires was 63.3% (n=31). Result: In 2001 the total expenses for laboratory practice were 21,865,230 won and the average per student was 102,418 won. Types of laboratories included single and complex. The mean size for laboratories was $318.7m^2$ and mean size for laboratories for fundamental nursing was $161.1m^2$. The range for number of students in a laboratory class was 20-30 for eight universities (30.8%). Among required laboratory equipment, items that were deficient in 50% in the universities were mercury and aneroid sphygmomanometers for children, electronic sphygmomanometers, Bell type fetal stethoscopes, sheepskin, beds for children, for gynecology, and electronic hilo beds. Among the elective equipment, items that were deficient in 50% of the universities were $O^2$ tents, Blackmore tubes, retractors, hot-water supply, and incentive spirometers. The number of items that needed to add to the equipment were 10 for required equipment and 22 for elective equipment. Conclusion: A standardized mandatory list of equipment for laboratory facilities and expenses for practice in 4-year nursing schools needs to be developed.

  • PDF

Analysis of ICU Treatment on Resection of Giant Tumors in the Mediastinum of the Thoracic Cavity

  • Kang, Nai-Min;Xiao, Ning;Sun, Xiao-Jun;Han, Yi;Luo, Bao-Jian;Liu, Zhi-Dong
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.14 no.6
    • /
    • pp.3843-3846
    • /
    • 2013
  • Objective: The purpose of this study was to assess prognosis after resection of giant tumors (including lobectomy or pneumonectomy) in the mediastinum. Materials and Methods: Patients with resection of a giant tumor in the mediastinum of the thoracic cavity received ICU treatment including dynamic monitoring of vital signs, arterial blood pressure and CVP detection, determination of hemorrhage, pulmonary function and blood gas assay, treatment of relevant complications, examination and treatment with fiber optic bronchoscopy, transfusion and hemostasis as well as postoperative removal of ventilators by invasive and non-invasive sequential mechanical ventilation technologies. Results: Six patients were rehabilitated successfully after ICU treatment with controlled postoperative errhysis and pulmonary infection by examination and treatment with fiber optic bronchoscopy without second application of ventilators and tubes after sequential mechanical ventilation technology. One patient died from multiple organ failure under ICU treatment due to postoperative active hemorrhage after second operative hemostasis. Conclusions: During peri-operative period of resection of giant tumor (including lobectomy or pneumonectomy) in mediastinum ofthe thoracic cavity, the ICU plays an important role in dynamic monitoring of vital signs, treatment of postoperative stress state, postoperative hemostasis and successful removal of ventilators after sequential mechanical ventilation.

Estimation of Flexural Strength of Hollow Prestressed Concrete Filled Steel Tube Piles (긴장력이 도입된 중공형 콘크리트 충전 강관말뚝의 휨강도 산정)

  • Paik, Kyu-Ho
    • Journal of the Korean Geotechnical Society
    • /
    • v.35 no.12
    • /
    • pp.91-100
    • /
    • 2019
  • Hollow prestressed concrete-filled steel tube (HCFT) piles, which combines PHC piles inside thin-wall steel tubes, were developed to increase the flexural strength of the pile with respect to the lateral load. Since P-M curves are needed for evaluating the structural safety of piles when applying HCFT piles to fields, equations for plotting P-M curves of HCFT piles in limit states were proposed. When the yield strength is applied to the steel tube and PC steel bar of HCFT piles, the proposed equations significantly underestimated the flexural strength of HCFT piles. Unlike the flexural strength test results, the proposed equations also provide greater flexural strengths for 12 mm thick steel pipe piles with the same diameter than for HCFT piles. However, when the ultimate strengths are used instead of the yield strengths for the steel tube and PC steel bar, the proposed equations provide the flexural strengths very close to the flexural strength test results.

Surface structure modification of vertically-aligned carbon nanotubes and their characterization of field emission property

  • adil, Hawsawi;Jeong, Gu-Hwan
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2016.02a
    • /
    • pp.159-159
    • /
    • 2016
  • Vertically-aligned carbon nanotubes (VCNT) have attracted much attention due to their unique structural, mechanical and electronic properties, and possess many advantages for a wide range of multifunctional applications such as field emission displays, heat dissipation and potential energy conversion devices. Surface modification of the VCNT plays a fundamental role to meet specific demands for the applications and control their surface property. Recent studies have been focused on the improvement of the electron emission property and the structural modification of CNTs to enable the mass fabrication, since the VCNT considered as an ideal candidate for various field emission applications such as lamps and flat panel display devices, X-ray tubes, vacuum gauges, and microwave amplifiers. Here, we investigate the effect of surface morphology of the VCNT by water vapor exposure and coating materials on field emission property. VCNT with various height were prepared by thermal chemical vapor deposition: short-length around $200{\mu}m$, medium-length around $500{\mu}m$, and long-length around 1 mm. The surface morphology is modified by water vapor exposure by adjusting exposure time and temperature with ranges from 2 to 10 min and from 60 to 120oC, respectively. Thin films of SiO2 and W are coated on the structure-modified VCNT to confirm the effect of coated materials on field emission properties. As a result, the surface morphology of VCNT dramatically changes with increasing temperature and exposure time. Especially, the shorter VCNT change their surface morphology most rapidly. The difference of field emission property depending on the coating materials is discussed from the point of work function and field concentration factor based on Fowler-Nordheim tunneling.

  • PDF

Analysis of Cadmium in Urine using Flame and Flameless Atomic Absorption Spectrophotometry (불꽃 및 비불꽃원자흡수분광법을 이용한 뇨중 카드뮴 분석)

  • Ham, Yong-Gyu;Lee, Seok-Ki;Jeon, Jae-Hong;Joung, Chang-Ung;Son, Bu-Soon
    • Analytical Science and Technology
    • /
    • v.12 no.5
    • /
    • pp.355-359
    • /
    • 1999
  • Trace cadmium was determined in urine by flame and nameless AAS. Inflame method, cadmium was extracted into MIBK from Cd-DDTC complex. In flameless method, samples were pretreated with 1%, Triton X-100. 1% $HNO_3$ and matrix modifier $Pd(NO_3)_2$. Analysis of cadmium was, performed at $450-750^{\circ}C$ ashing temperature by use of pyrocoated tubes. Results of analysis, flameless method superior in sample treatment and reproducibility to flame method and highest absorbance was obtained at $550^{\circ}C$ ashing temperature. 100 mg/L $Pd(NO_3)_2$ concentration. Proposed method were applied to the determination of cadmium in standard urine Lononorm-Metalle 3.

  • PDF

Push-out tests and bond strength of rectangular CFST columns

  • Qu, Xiushu;Chen, Zhihua;Nethercot, David A.;Gardner, Leroy;Theofanous, Marios
    • Steel and Composite Structures
    • /
    • v.19 no.1
    • /
    • pp.21-41
    • /
    • 2015
  • Push-out tests have been conducted on 18 rectangular concrete-filled steel tubular (CFST) columns with the aim of studying the bond behaviour between the steel tube and the concrete infill. The obtained load-slip response and the distribution of the interface bond stress along the member length and around the cross-section for various load levels, as derived from measured axial strain gradients in the steel tube, are reported. Concrete compressive strength, interface length, cross-sectional dimensions and different interface conditions were varied to assess their effect on the ultimate bond stress. The test results indicate that lubricating the steel-concrete interface always had a significant adverse effect on the interface bond strength. Among the other variables considered, concrete compressive strength and cross-section size were found to have a pronounced effect on the bond strength of non-lubricated specimens for the range of cross-section geometries considered, which is not reflected in the European structural design code for composite structures, EN 1994-1-1 (2004). Finally, based on nonlinear regression of the test data generated in the present study, supplemented by additional data obtained from the literature, an empirical equation has been proposed for predicting the average ultimate bond strength for SHS and RHS filled with normal strength concrete.