• Title/Summary/Keyword: Tubes

Search Result 3,133, Processing Time 0.025 seconds

Theoretical impact of Kelvin's theory for vibration of double walled carbon nanotubes

  • Hussain, Muzamal;Naeem, Muhammad N.;Asghar, Sehar;Tounsi, Abdelouahed
    • Advances in nano research
    • /
    • v.8 no.4
    • /
    • pp.307-322
    • /
    • 2020
  • In this article, free vibration of double-walled carbon nanotubes (DWNT) based on nonlocal Kelvin's model have been investigated. For this purpose, a nonlocal Kelvin's model is established to observe the small scale effect. The wave propagation is employed to frame the governing equations as eigenvalue system. The influence of nonlocal parameter subjected to different end supports has been overtly examined. The new set of inner and outer tubes radii investigated in detail against aspect ratio. The influence of boundary conditions via nonlocal parameter is shown graphically. Due to small scale effect fundamental frequency ratio decreases as length to diameter ratio increases. Small scale effect becomes negligible on all end supports for the higher values of aspect ratio. With the smaller inner tube radius double-walled CNT behaves more sensitive towards nonlocal parameter. The results generated furnish the evidence regarding applicability of nonlocal model and also verified by earlier published literature.

Numerical investigation on the response of circular double-skin concrete-filled steel tubular slender columns subjected to biaxial bending

  • Abu-Shamah, Awni;Allouzi, Rabab
    • Steel and Composite Structures
    • /
    • v.37 no.5
    • /
    • pp.533-549
    • /
    • 2020
  • Recently, Concrete-filled double skin steel tubular (CFDST) columns have proven an exceptional structural resistance in terms of strength, stiffness, and ductility. However, the resistance of these column members can be severely affected by the type of loading in which bending stresses increase in direct proportion with axial load and eccentricity value. This paper presents a non-linear finite element based modeling approach that studies the behavior of slender CFDST columns under biaxial loading. Finite element models were calibrated based on the outcomes of experimental work done by other researchers. Results from simulations of slender CFDST columns under axial loading eccentric in one direction showed good agreement with the experimental response. The calibrated models are expanded to a total of thirty models that studies the behavior of slender CFDST columns under combined compression and biaxial bending. The influences of parameters that are usually found in practice are taken into consideration in this paper, namely, eccentricity-to-diameter (e/D) ratios, slenderness ratios, diameter-to-thickness (D/t) ratios, and steel contribution ratios. Finally, an analytical study based on current code provisions is conducted. It is concluded that South African national standards (2011) provided the most accurate results contrasted with the Eurocode 4 (2004) and American Institute of Steel Construction (2016) that are found to be conservative. Accordingly, correction factors are proposed to the current design guidelines to provide more satisfactory results.

Room Temperature Ferromagnetism on Co and Fe Doped Multi-wall Carbon Nano-tube

  • Chae, K.H.;Gautam, S.;Yu, B.Y.;Song, J.H.;Augustine, S.;Kang, J.K.;Asokan, K.
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2011.02a
    • /
    • pp.171-171
    • /
    • 2011
  • Co and Fe doped multi-wall carbon nano-tubes (MWCNTs) synthesized by microwave plasma enhanced chemical vapor deposition (PECVD) technique are investigated with synchrotron radiations at Pohang Light Source (PAL) and European Synchrotron Radiation Facility (ESRF). Near edge x-ray absorption spectroscopy (NEXAFS) measurement at C K, Co $L_{3,2}$ and Fe $L_{3,2}$-edges, and x-ray magnetic circular dichroism (XMCD) at Co and Fe $L_{3,2}$-edges have been carried at 7B1 XAS KIST and 2A MS beamline, respectively, to understand the electronic structure and responsible magnetic interactions at room temperature. X-ray absorption spectroscopy (XAS) at C K-edge shows significant p-bonding and Co and Fe L-edges proves the presence of $Co^{2+}$ and $Fe^{2+}$ in octahedral symmetry. Co and Fe doped MWCNTs show good XMCD spectra at 300K. The effect on the magnetism is also studied through swift heavy ion (SHI) radiations and magnetism is found enhanced and change in the electronic structure in Co-CNTs is investigated.

  • PDF

On-Site Corrosion Behavior of T91 Steel after Long-Term Service in Power Plant

  • He, Yinsheng;Chang, Jungchel;Lee, Je-Hyun;Shin, Keesam
    • Korean Journal of Materials Research
    • /
    • v.25 no.11
    • /
    • pp.612-615
    • /
    • 2015
  • In this work, on-site corrosion behavior of heat resistant tubes of T91, used as components of a superheater in a power plant for up to 25,762 h, has been investigated using scanning electron microscopy(SEM), energy dispersive X-ray spectroscopy (EDS), and electron backscattered diffraction(EBSD), with the objectives of studying the composition, phase distribution, and evolution during service. A multi-layer structure of oxide scale was found on both the steamside and the fireside of the tube surface; the phase distribution was in the order of hematite/magnetite/spinel from the outer to the inner matrix on the steamside, and in the order of slag/magnetite/spinel from the outer to the inner matrix on the fireside. The magnetite layer was found to be rich in pores and cracks. The absence of a hematite layer on the fireside was considered to be due to the low oxygen partial pressure in the corrosion environment. The thicknesses of the hematite and of the slag-deposit layer were found to exhibit no significant change with the increase of the service time.

Eddy Current Testing of Type-439 S/S Tube of MSR in Turbine System (터빈 습분분리재열기 Type-439 스테인리스강 튜브 와전류검사)

  • Lee, Heejong;Cho, Chanhee;Jung, Jeehong;Moon, Gyoonyoung
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • v.4 no.2
    • /
    • pp.50-56
    • /
    • 2008
  • The tubes in heat exchanger are typically made of copper alloy, stainless steel, carbon steel, titanium alloy material. Type-439 ferritic stainless steel is ferromagnetic material, and furnish higher heat transfer rates than austenitic stainless steels and higher resistance to corrosion-induced flaws. Ferritic stainless steel can be found in low-pressure(LP) feedwater heaters and moisture separator reheaters(MSRs) in turbine system. LP feedwater heaters generally utilize thin wall Type-439 stainless steel tubing, whereas MSRs typically employ a heavier wall tubing with integral fins. Service-induced damage can occur on the O.D(outside diameter) surface of Type-439 ferritic stainless steel tubing which is employed for MSRs tubing, and the most typical damage mechanism is vibration-induced tube-to-TSP(tube support plate) wear and fatigue cracking. The wear has been reported that occurs mainly on the OD surface. Accordingly, in this study, we have evaluated the flaw sizing capability of magnetic saturation eddy current technique using magnetic saturation probe and flawed specimen.

  • PDF

Haptic Design of a Wearable Wrist Massage Device as a Capstone Design Project of Designeer Education Program (디자이니어 양성 커리큘럼 내 융합설계프로젝트 사례: 웨어러블 손목 마사지 기기의 햅틱 디자인)

  • Lim, Dokshin;Kwon, Kyunghyun
    • Journal of Engineering Education Research
    • /
    • v.23 no.2
    • /
    • pp.43-48
    • /
    • 2020
  • This paper deals with a Capstone Design project which is a wearable haptic wrist massage device design carried out within the 'Designeer' education program. Following design thinking process is recommended throughout a year in order to ensure a desirable, feasible and viable product. Dealing with a real problem of the field requires open-minded and flexible attitudes both from students and professors. Integrating design in an engineering project does not mean always making better looking product. User experience design allows wider opportunity to engineers to deal with design. A case study of developing a wearable wrist massage device shown in this paper demonstrate haptic design and how haptic properties can be optimized to offer best user experience of hand massaging. This study identified that starting lateral pressure movements from the center in larger area using air tubes gives better feeling as self-massage using wrist wearing devices.

Miniaturization of disposable functional flow tube (기능성 일회용 호흡관의 소형화 연구)

  • Kim, Kyung-Ah;Lee, Tae-Soo;Cha, Eun-Jong
    • Journal of Sensor Science and Technology
    • /
    • v.14 no.4
    • /
    • pp.250-257
    • /
    • 2005
  • Respiratory tubes with the length of 35 mm and the diameter of 10, 15, and 20 mm were made and both the static($P_{S}$) and dynamic($P_{D}$) pressures were measured for steady flow rates ranging 1-12 l/sec. Regression analysis resulted successful fitting of $P_{S}$ and $P_{D}$ data with quadratic equations with correlation coefficients higher than 0.99. The measurement standards of the American Thoracic Society (ATS) were applied to $P_{S}$ data, which demonstrated the smallest tube diameter of 15 mm to satisfy the ATS standards. The maximum $P_{D}$ value of the velocity type transducer with the diameter of 15 mm was estimated to be 75 cm$H_{2}O$, implying approximately 7 times larger sensitivity than the widely used pneumotachometer. These results showed that the velocity type respiratory air flow transducer is a unique device accomplishing miniaturization with the sensitivity increased, thus would be of great advantage to develop portable devices.

Design Criteria to Miniaturize the Single Use Functional Respiratory Air Flow Tube

  • Kim Kyung Ah;Lee Tae Soo;Cha Eun Jong
    • Journal of Biomedical Engineering Research
    • /
    • v.26 no.3
    • /
    • pp.163-169
    • /
    • 2005
  • Respiratory tubes with a length of 35mm and diameters of 10, 15, and 20mm were made for experimental purpose, and both the static$(P_s)\;and\;dynamic(P_D)$ pressures were simultaneously measured for steady flow rates ranging 1-12//sec. Least squares analysis resulted successful fitting of $P_s\;and\;P_D$ data with quadratic equations with correlation coefficients higher than 0.99(P<0.0001). The spirometric measurement standards of the American Thoracic Society(ATS) were applied to $P_s$ data, which demonstrated the smallest tube diameter of 15mm to satisfy the ATS standards. The maximum $P_D$ value of the velocity type transducer(the functional single use respiratory air flow tube) with the diameter of 15mm was estimated to be approximately $75cmH_2O$, implying more than 7 times larger sensitivity than the widely used pneumotachometers. These results showed that the velocity type respiratory air flow transducer is a unique device accomplishing miniaturization with the sensitivity increased, thus would be of great advantage to develop portable medical devices.

Ozone Generation Characteristics by according to the Coaxial Electrode Geometry (동축형 전극구조 변화시의 오존생성 특성)

  • 조국희;이홍식;이형호
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.14 no.2
    • /
    • pp.68-74
    • /
    • 2000
  • In this paper the concentration, yield and generation quantity of the ozone by the superposition discharge according to the coaxial electrodes geometry is described. In order to improve the ozone generation, a new type of ozonizer is proposed, where a silent discharge and a surface discharge are generated in the separated discharge spaces at the same time. To investigate the ozone generation dependency on electrode geometry, a few discharge tubes with different geometry were fabricated. In our experiment, the 60[Hz] one phase voltage is applied to the discharge tube which has three electrodes. And three kinds of discharges, two silent discharges and a surface discharge are superposed in the same space of the ozonizer. As a result, the followings are obvious. When two kinds of discharges are superposed under the condition using 3 electrode-3gap discharge tube, the maximum ozone efficiency is obtained.

  • PDF

A Study on the Comparison to Source Profile of the Major Terpenes from Pine Tree and Korean Pine Tree (소나무와 잣나무에서 배출되는 주요 테르펜의 배출특성에 관한 비교연구)

  • 지동영;김소영;한진석
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.18 no.6
    • /
    • pp.515-525
    • /
    • 2002
  • A field study was conducted to estimate the emission rate of biogenic volatile organic compounds (BVOCs) from pine trees. In addition, the influences of meteological variables on their distribution characteristics have been investigated. A vegetation enclosure chamber was designed and constructed of Tedlar bag and acril. Sorbent tubes made up of Tenax TA and Carbotrap were used to collect biogenic VOCs emitted from each individual tree. Analysis of BVOCs was performed using a GC-FID system. The fundamental analytical parameters including linearity, retention time, recovery efficiency, and breakthrough volume were examined and verified for the determination of monoterpene emission rates. Total average concentration of each component is found to be $\alpha$-pinene (16.5), $\beta$-pinene (4.61) from pine trees, and $\alpha$-pinene (42.4), $\beta$-pinene (18.7 ng(gdw)$^{-1}$ hr$^{-1}$ ) from Korean pine trees. On the basis of our study, $\alpha$-pinene was found to be the major monoterpene emitted from both pine and Korean pine trees which were accompanied by $\beta$-pinene, camphene, and limonene. In ambient air, variable monoterpene compositions of emissions from pine trees were similar to Korean pine trees. Emission rates of monoterpene from each tree were found to depend on such parameters as temperature and solar radiation.