• Title/Summary/Keyword: Tube-by-Tube

Search Result 7,118, Processing Time 0.04 seconds

A Study on the Press Forming by Rectangular Tube of Al6063 Alloys (Al6063 합금 중공각재 튜브에 의한 프레스 성형 연구)

  • Lee, Choung-Kook;Kim, Won-Jung
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.10 no.6
    • /
    • pp.56-62
    • /
    • 2011
  • In this study, a method for the press forming of rectangular aluminium tube has been proposed. Rectangular aluminium tube has high stiff as the cold steel which can be lighter over 30% weight. It is increased every year by being recycled over 80%. Press die consists of punch, wing-die and holder for aluminium tube bending. When punch is applied with aluminium tube, holder is operated as same punch and wing-die is rotated through hinge. Stress-strain relations and springback are considered by bending angle of aluminium tube. In this study, the behaviors on tubes of square aluminium and rectangular aluminium with different thickness and area are established by the analysis of $DEFORM^{TM}$-3D program. Reducing fuel consumption is expected by using the aluminium tube deformation and it becomes the lightweight through recycling.

Concept Design of Ludwieg Tube at Konkuk University (건국대학교 Ludwieg Tube 개념 설계에 관한 연구)

  • Kim, Young Ju;Byun, Yung Hwan;Park, Soo Hyung;Park, Gisu;Lee, Jongkook
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.46 no.9
    • /
    • pp.703-711
    • /
    • 2018
  • A preliminary design tool of a hypersonic Ludwieg tube facility which simulates real-flight environment was developed and its performance was verified by CFD(Computation Fluid Dynamics) calculations. The operating theory of Ludwieg tube was studied to develop the preliminary design tool. Using the preliminary design tool, Ludwieg tube specifications were determined to satisfy target performance. The Ludwieg tube which produces high speed flows(the Mach number ranging 4 to 10) was designed. Especially altitude simulation at Mach 4 flow could be performed.

Computation of Compact Heat Exchanger Performance by the Heat Exchangelet Method : Effect of Tube-to-tube Conduction along the Fin (미소열교환기법에 의한 밀집형 열교환기의 성능 계산 : 핀을 통한 튜브간 전도의 영향)

  • 성시경;송태호;최영철
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.12 no.5
    • /
    • pp.494-501
    • /
    • 2000
  • Effectiveness of a 3-pass plate finned-tube heat exchanger is calculated using heat exchangelet method by changing the shape of fin and the arrangement of tubes. The alternative refrigerant R134a is taken in this study. Conduction between neighboring tubes along the fin is taken into account in addition to convection between the fin and the surrounding air. Governing equations are obtained by using energy balance in a small control volume containing a tube and fins. They are numerically solved following the tube. Effect of tube-to-tube conduction is investigated in single-phase and two-phase flows with various fin shapes and arrangements of tubes. Improvement of effectiveness by fin perforation is studied too. The results shows that perforating fins, increasing the number of tubes, and increasing the distance between neighboring tubes at the same fin area enhance the effectiveness.

  • PDF

An Easy Detection Method of Fasciola Eggs by Kim's Sedimental Tube (K-식(式) 침전관(沈澱管)에 의한 간질충란(肝蛭蟲卵) 간이검사법(簡易檢査法))

  • Kim, Kyo-Joon;Kim, Sang-Keun;Hu, Min-Do
    • Korean Journal of Veterinary Research
    • /
    • v.23 no.1
    • /
    • pp.105-110
    • /
    • 1983
  • The studies carried out to investigate the detection method of Fasciola eggs from positive cattle feces in the intradermal reaction method with laborsaving composition of sieves and Kim's sedimental tube method. The results obtained are summarized as follows: 1. The detection method of Fasciola eggs was improved by 3 meshes (100mesh, 150mesh, 250mesh) for filteration of fecal fluid contained Fasciola eggs. 2. Third type of tube in the 3 kinds of sedimental tube had the highest recovers rate of Fasciola eggs. Thus, this type of tube was selected and called as Kim's sedimental tube. 3. A-II, A-III, B-III and C-III type by Kim's sedimental tube method had the recovery rates of eggs in the 1st drop as ranged 99 to 100% and, A-I, B-II, C-II as 71 to 91%. 4. These Type of tubes were useful to detect Fasciola eggs and to shorten the time of the diagnostic procedures. 5. The Kim's sedimental tube method showed high recovery rates and convenient procedures as compared with other detection methods reported. In addition, the EPG value can also be obtained by this method. Therefore, it is desirable that the Kim's sedimental tube method could be recommended to clinicians.

  • PDF

The Characteristics of a Sandwich Tube with a Truss Core under Lateral Loading (측면하중을 받는 트러스형 내부구조를 가지는 샌드위치 튜브의 특성)

  • Jung, C.G.;Seong, D.Y.;Yang, D.Y.;Moon, K.J.;Ahn, D.G.
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2007.05a
    • /
    • pp.268-271
    • /
    • 2007
  • A sandwich tube is a structured material that has two inner and outer circular tubes and light material between them. In this paper, a sandwich tube with a pyramidal truss core is introduced. Fabrication method and example made by brazing are shown. The behavior of the sandwich tube under lateral loading is predicted by analytical and numerical method. Comparative study between the sandwich and the monocoque tube is performed at a point of view such as strength and weight saving. As a result, proposed tube is appropriate for application to lightweight structural material

  • PDF

A Study on the Galvanic corrosion and its Protection on Heat Exchanger Tube Plate (열교환기 관판의 전지작용부식과 방지에 관한 연구)

  • 임우조;홍성희;윤병두
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.25 no.2
    • /
    • pp.344-350
    • /
    • 2001
  • This paper was studied on the characteristics of galvanic corrosion and its protection on heat exchanger tube plate in the sea water. In this paper, behavior of pitting corrosion of Ni-al bronze connected with Ti tube was measured af flow velocity of 0 m/s and 2.4 m/s. To protect galvanic corrosion, the protection characteristics of Ni-Al bronze connected with Ti tube by Zn-base alloys galvanic anode and hexagonal nylon insert was investigated. Main results obtained asre al follows: 1) The galvanic corrosion of Ni-Al bronze connected with Ti-tube is more active than single Ni-al bronze. 2) As the circuit resistance increase under the cathodic protection employing Zn-base alloys galvanic anode, Ni-al bronze connected with Ti tube is cathodically unpolarized. 3) The corrosion of Ni-Al bronze connected with Ti tube by nylon insert controls approximately 73% than not nylon insert.

  • PDF

A Study on the Galvanic corrosion and its Protection on Heat Exchanger Tube Plate (열교환기 관판의 전지작용부식과 방지에 관한 연구)

  • U-J Lim;S-H Hong;B-D Yun
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.25 no.2
    • /
    • pp.345-345
    • /
    • 2001
  • This paper was studied on the characteristics of galvanic corrosion and its protection on heat exchanger tube plate in the sea water. In this paper, behavior of pitting corrosion of Ni-al bronze connected with Ti tube was measured af flow velocity of 0 m/s and 2.4 m/s. To protect galvanic corrosion, the protection characteristics of Ni-Al bronze connected with Ti tube by Zn-base alloys galvanic anode and hexagonal nylon insert was investigated. Main results obtained asre al follows: 1) The galvanic corrosion of Ni-Al bronze connected with Ti-tube is more active than single Ni-al bronze. 2) As the circuit resistance increase under the cathodic protection employing Zn-base alloys galvanic anode, Ni-al bronze connected with Ti tube is cathodically unpolarized. 3) The corrosion of Ni-Al bronze connected with Ti tube by nylon insert controls approximately 73% than not nylon insert.

Convection Effects on PGSE-NMR Self-Diffusion Measurements at Low Temperature: Investigation into Sources of Induced Convective Flows

  • Chung, Kee-Choo;Yu, Hyo-Yeon;Ahn, Sang-Doo
    • Bulletin of the Korean Chemical Society
    • /
    • v.32 no.6
    • /
    • pp.1970-1974
    • /
    • 2011
  • The effects of convection on the measurement of the diffusion coefficients of liquids by the pulsed gradient spin echo (PGSE) NMR method at low temperature are discussed. To examine the generation of convective flows, we used four different types of sample tubes in the diffusion measurements with temperature variation; a normal 5 mm NMR tube, a Shigemi tube, an ELISE type tube, and a capillary tube. Below room temperature, the calculated diffusion coefficients of chloroform in 5 mm o.d. type tubes increased with decreasing temperature, while those in the capillary tube decreased linearly. The convective flow was found to be significant even at low temperature and it seemed to be mainly induced by the transverse temperature gradient. It was also found that the capillary tube was most appropriate to measure the diffusion coefficients, since its small diameter is effective in suppressing the convective flows at both high and low temperatures.

A Study on the Post Deformation According to an Environmental Temperature of the Plastic Fuel Tube for Automobile (자동차용 플라스틱 연료튜브의 환경온도에 따른 후변형에 관한 연구)

  • Park, J.S.;Moon, C.Y.;Jeong, Y.D.
    • Journal of Power System Engineering
    • /
    • v.7 no.2
    • /
    • pp.56-60
    • /
    • 2003
  • Recently the plastic fuel tube is usually used to reduce production cost and weight in automobiles. These days, material used to plastic fuel tube is the polyamide12. The fuel tube is made of the PA12. Post deformation of the tube has been changed by environmental temperature. So, it is important to prevent post deformation. The experiment is performed to investigate post deformation of the tube produced by each bending process. In this study, the results we obtained are used to bending process system for post deformation as the environmental temperature of the tube. It turned out that the method of steam heating and air cooling was shown less deformation than other methods.

  • PDF

Characteristics of Refrigerant Flow through Capillary Tubes and Short Tube Orifices

  • Kim, Yong-Chan;Choi, Jong-Min
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.7
    • /
    • pp.11-21
    • /
    • 1999
  • The capillary tube and short tube orifice have been widely used as an expansion device in the refrigeration and air-conditioning system. To improve the system performance, expansion devices need to be optimized with the components of a refrigeration system. In the present study, a numerical model for a capillary, which could predict the flow rate and properties along a tube, was developed by assuming homogeneous two-phase flow. A semi-empirical flow model for evaluation of the flow rate through a short tube orifice was also developed by using the experimental data. Finally, the results of the numerical model for a capillary was compared with those of the semi-empirical model for a short tube orifice to identify the dominant flow factors for the expansion devices.

  • PDF