• 제목/요약/키워드: Tube-Temperature

Search Result 2,035, Processing Time 0.037 seconds

Light Emission and Plasma Property in the External Electrode Fluorescent Lamps (외부전극 형광램프의 발광 및 플라즈마 특성)

  • Ahn, S.;Lee, M.;Jeong, J.;Kim, J.;Yoo, D.;Koo, J.;Kang, J.;Hong, B.;Choi, E.;Cho, G.
    • Journal of the Korean Vacuum Society
    • /
    • v.16 no.3
    • /
    • pp.172-180
    • /
    • 2007
  • A new diagnostics of plasma electron temperature and plasma density is introduced with the observation of the light emission along the tube of external electrode fluorescent lamps. With two different methods operating an external electrode fluorescent lamp of outer diameter 4.0 mm and length 860 mm for the back-light source of 37-inch LCD-TVs, the lighting modes and the plasma properties are investigated. In the center balance operation, the light-emission propagates simultaneously from both sides of the high voltage electrodes to the center of the lamp, while in conventional operation the light-emission propagates from the one end of a high voltage to the other ground electrode. In the operation value of luminance $10,000{\sim}15,000cd/m^2$, the electron plasma thermal energy $(kT_e)$ is about $1.3{\sim}2.7eV$ with the electron density $(n_e)$ is about $(1.6{\sim}3.6){\times}10^{16}m^{-3}$.

Experimental Study of Characteristics of Three-Ring Impedance Meter and Dependence of Characteristics on Electric Conductivity of Fluids (3-ring 임피던스미터의 유체 전기 전도도 독립성에 대한 실험적 연구)

  • Kim, Jong-Rok;Ahn, Yeh-Chan;Kim, Moo-Hwan
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.34 no.11
    • /
    • pp.1027-1033
    • /
    • 2010
  • A two-phase (gas-liquid) flow is a common phenomenon in fluidic systems, e.g., fluidic systems in the electro-magnetic or nuclear power generation industry and in the steel industry. The measurement of a two-phase flow is important for guaranteeing the safety of the system and for achieving the desired performance. The measurement of the void fraction, which is one of the parameters of the two-phase flow that determines the pressure drop and heat transfer coefficient, is very important. The time resolution achieved by employing the impedance method that can be used to calculate the void fraction from the impedance of the fluid is high because the electric characteristics are taken into account. Therefore, this method can be employed to accurately measure the void fraction without distortion of flow in real time by placing electrodes on the walls of the tubes. Coney analytically studied a ring-type impedance meter, which can be employed in a circular tube. The aim of this study is to experimentally verify the robustness of a three-ring impedance meter to variations in the electric conductivity of the fluid; this robustness was suggested by Coney but was not experimentally verified.

Pasteurization Efficiency of a Continuous Microwave HTST (연속식 마이크로파 고온단시간 살균시스템에서 우유의 살균효과)

  • Kim, Suk-Shin;Lee, Joo-Hee;Kim, Sang-Yong
    • Korean Journal of Food Science and Technology
    • /
    • v.31 no.5
    • /
    • pp.1392-1396
    • /
    • 1999
  • This work was to apply the microwave energy to HTST pasteurization of milk in order to prevent undesirable quality changes due to the fouling and overheating on the surface of heat exchanger. A continuous tubulartype microwave pasteurization system was designed using a domestic microwave oven(800w and 2,450MHz). Raw milk was HTST pasteurized$(at\;72^{circ}C\;for\;15\;sec)$ by three methods; by heating in a stainless steel tube immersed in a hot water bath(MP0), by heating in a microwave cavity to a desired temperature and then holding in a hot water bath(MP1) and by both heating and holding in a microwave cavity(MP2). The microbial quality based on the total plate count and Psychotrophic bacterial count was in the order MP0, MP2 and MP1 ; however, the quality difference was not significant(p<0.05) when the initial microbial numbers were involved in the statistical analysis. In addition, the three samples pasteurized by different methods showed the similar microbial quality based on the coliform count and phosphatase activity. The similar microbial quality of the three samples supports the potential use of microwave energy for the pasteurization of milk and other fluid food products.

  • PDF

A Study on the Heat Flow Analysis of Infra-Red Signature Suppression System for Naval Ship (함정 적외선 신호저감 장치의 열 유동해석 연구)

  • Yoon, Seok-Tae;Cho, Yong-Jin;Ko, Dae-Eun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.11
    • /
    • pp.740-746
    • /
    • 2017
  • Infrared signatures emitted from hot exhaust gases generated by the internal combustion engine and generator of naval ships and from the metal surfaces of the funnel have become the targets of infrared homing missiles, which is the main cause of a reduced survivability of naval ships. The infrared signatures from the exhaust gas and the metal surface of a funnel can be reduced by installing an infrared signature suppression (IRSS) system on a ship. The IRSS system consists of three parts: an eductor that generates turbulent flow of the exhaust gas, a mixing tube that mixes the exhaust gas with ambient air, and a diffuser that forms an air film using the pressure difference between the inside and outside air. As a basic study to develop an IRSS system using domestic technology, this study analyzed the model test conditions of an IRSS system developed by an overseas engineering company and installed on a domestic naval ship, and a numerical heat-flow analysis was conducted based on the results of the aforementioned analysis. Numerical heat-flow analysis was performed using a commercial numerical-analysis application, and various turbulence models were considered. As a result, the temperature and velocity of the exhaust gas at the educator inlet and diffuser outlet and that of the metal surface of the diffuser were measured, and found to agree well with the measurement results of the model test.

Removal of Fe, Si from Silicon Carbide Sludge Generated in the Silicon Wafer Cutting Process (실리콘 웨이퍼 절단공정(切斷工程)에서 발생(發生)하는 실리콘 카바이드 슬러지로부터 철(鐵), 실리콘 제거(除去))

  • Park, Hoey Kyung;Go, Bong Hwan;Park, Kyun Young;Kang, Tae Won;Jang, Hee Dong
    • Resources Recycling
    • /
    • v.22 no.2
    • /
    • pp.22-28
    • /
    • 2013
  • In the present study, the possibility of recovering and recycling the silicon carbide(SiC) from a silicon sludge by removing Fe and Si impurities was investigated. Si and SiC were separated from the silicon sludge using centrifugation. The separated SiC concentrate consisted of Fe, Si and SiC, in which Fe and Si were removed to recover the pure SiC. Leaching with acid/alkali solution was compared with the vapor-phase chlorination. The Fe concentration removed in the SiC was 49 ppm, and it was separated by leaching with 1 M HCl solution at $80^{\circ}C$ for 1 h. The Si concentration removed in the SiC was 860 ppm, and it was separated by leaching with 1M NaOH solution at $50^{\circ}C$ for 1 h. The SiC concentrate was chlorinated in a tubular reactor, 2.4 cm in diameter and 32 cm in length. The boat filled with SiC concentrate was located at the midpoint of the alumina tube, then, the chlorine and nitrogen gas mixture was introduced. The Fe and Si concentration removed in the SiC were 48 ppm and 405 ppm, respectively, at $500^{\circ}C$ reactor temperature, 4 h reaction time, 300 cc/min gas flow rate, and 10% $Cl_2$ gas mole fraction.

Comparison among the Sperm Preparation Methods on the Human Spermatozoa (인간정자에 있어서 정자처리법의 비교)

  • Pang, Myung-Geol;Chung, Ku-Min;Shin, Chang-Jae;Kim, Jung-Gu;Moon, Shin-Yong;Chang, Yoon-Seok;Lee, Jin-Yong;Lee, Sang-Hoon;Chung, Yung-Chai;Kim, Chang-Keun
    • Clinical and Experimental Reproductive Medicine
    • /
    • v.20 no.2
    • /
    • pp.107-115
    • /
    • 1993
  • Procedures to separate motile. normal & motile and acrosome-reacted sperm with high efficiency have clinical application in Assisted Reproductive Technology in terms of increasing the probability of fertilization by a normal sperm and subsequent normal embryonic development. This study evaluated the effects of 10 sperm preparation techniques [Swim-up from a washed pellet (SU). Swim-up from semen (SO). Continuous Percoll Gradients I (PIC). Discontinuous Percoll Gradients I (PID). Continuous Percoll Gradients II(P II C). Discontinuous Percoll Gradients II(P II D), SpermPrep (SFC). Wang's tube (WT). Albumin Gradients (AG), Low temperature capacitation (LTC)] on motility (%), normal morphology (%), motile sperm recovery rate(%). morphologically normal & motile sperm recovery rate (%), true acrosome reaction (%) and fertilizing ability. A P II D proved to be an effective means of separating morphologically normal & motile sperm. Our results indicated the P II D has advantages as compared with other methods in terms of recovery rate. enhancement of motility and normal morphology. And a LTC seems to be an effective means of enhancing the true acrosome reaction and fertilizing ability. These results suggest that the combined method of LTC and P II D for separation of morphologically normal & motile sperm and acrosome reacted sperm may be a useful procedure for intrauterine insemination and in vitro fertilization in the management of male factor infertility as well as for isolation of subpopulation of sperm for basic research.

  • PDF

The Effect of Transverse Magnetic field on Macrosegregation in vertical Bridgman Crystal Growth of Te doped InSb

  • Lee, Geun-Hee;Lee, Zin-Hyoung
    • Proceedings of the Korea Association of Crystal Growth Conference
    • /
    • 1996.06a
    • /
    • pp.522-522
    • /
    • 1996
  • An investigation of the effects of transverse magnetic field and Peltier effect on melt convection and macrosegregation in vertical Bridgman crystal grosth of Te doped InSb was been carried out by means of microstructure observation, Hall measurement, electrical resistivity measurement and X-ray analysis. Before the experiments, Interface stability, convective instability and suppression of convection by magnetic field were calculated theoretically. After doping 1018, 1019 cm-3 Te in InSb, the temperature of Bridgman furnace was set up at $650^{\circ}C$. The samples were grown in I.D. 11mm, 100mm high quartz tube. The velocity of growth was about 2${\mu}{\textrm}{m}$/sec. In order to obtain the suppression of convection by magnetic field in the middle of growth, 2-4KG magnetic field was set on the melt. For searching of the shape of solid-liquid interface and the actual velocity of crystal growth, let 2A current flow from solid to liquid for 1second every 50seconds repeatedly (Peltier effect). The grown InSb was polycrystal, and each grain was very sharp. There was no much difference between the sample with and without magnetic field at a point of view of microstructure. For the sample with Peltier effect, the Peltier marks(striation) were observed regularly as expected. Through these marks, it was found that the solid-liquid interface was flat and the actual growth velocity was about 1-2${\mu}{\textrm}{m}$/sec. On the ground of theoretical calculation, there is thermosolutal convection in the Te doped InSb melt without magnetic field in this growth condition. and if there is more than 1KG magnetic field, the convection is suppressed. Through this experiments, the effective distribution coefficients, koff, were 0.35 in the case of no magnetic field, and 0.45 when the magnetic field is 2KG, 0.7 at 4KG. It was found that the more magnetic field was applied, the more convection was suppressed. But there was some difference between the theoretical calculation and the experiment, the cause of the difference was thought due to the use of some approximated values in theoretical calculation. In addition to these results, the sample with Peltier effect showed unexpected result about the Te distribution in InSb. It looked like no convection and no macrosegregation. It was thought that the unexpected behavior was due to Peltier mark. that is, when the strong current flew the growing sample, the mark was formed by catching Te. As a result of the phenomena, the more Te containing thin layer was made. The layer ruled the Hall measurement. The values of resistivity and mobility of these samples were just a little than those of other reference. It was thought that the reason of this result was that these samples were due to polycrystal, that is, grain boundaries had an influence on this result.

  • PDF

Comparison of Parallel and Fan-Beam Monochromatic X-Ray CT Using Synchrotron Radiation

  • Toyofuku, Fukai;Tokumori, Kenji;Kanda, Shigenobu;Ohki, Masafumi;Higashida, Yoshiharu;Hyodo, Kazuyuki;Ando, Masami;Uyama, Chikao
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2002.09a
    • /
    • pp.407-410
    • /
    • 2002
  • Monochromatic x-ray CT has several advantages over conventional CT, which utilizes bremsstrahlung white x-rays from an x-ray tube. There are several methods to produce such monochromatic x-rays. The most popular one is crystal diffraction monochromatization, which has been commonly used because of the fact that the energy spread is very narrow and the energy can be changed continuously. The alternative method is the use of fluorescent x-ray, which has several advantages such as large beam size and fast energy change. We have developed a parallel-beam and a fan-beam monochromatic x-ray CT, and compared some characteristics such as accuracy of CT numbers between those systems. The fan beam monochromatic x-rays were generated by irradiating target materials by incident white x-rays from a bending magnet beam line NE5 in 6.5 GeV Accumulation Ring at Tukuba. The parallel beam monochromatic x-rays were generated by using a silicon double crystal monochromator at the bending magnet beam line BL-20BM in Spring-8. A Cadmium telluride (CdTe) 256 channel array detector with 512mm sensitive width capable of operating at room temperature was used in the photon counting mode. A cylindrical phantom containing eight concentrations of gadolinium was used for the fan beam monochromatic x-ray CT system, while a phantom containing acetone, ethanol, acrylic and water was used for the parallel monochromatic x-ray CT system. The linear attenuation coefficients obtained from CT numbers of those monochromatic x-ray CT images were compared with theoretical values. They showed a good agreement within 3%. It was found that the quantitative measurement can be possible by using the fan beam monochromatic x-ray CT system as well as a parallel beam monochromatic X-ray CT system.

  • PDF

Pasteurization Efficiency and Physico-chemical Changes of Soymilk HTST Pasteurized Using Microwaves (두유의 마이크로파 고온단시간 살균시 살균효과 및 이화학적 성분 변화)

  • Kim, Suk-Shin;Lee, Joo-Hee
    • Korean Journal of Food Science and Technology
    • /
    • v.31 no.5
    • /
    • pp.1196-1202
    • /
    • 1999
  • This work was to determine the microbial and physico-chemical changes of HTST-pasteurized soymilk using microwave energy. Soymilk was HTST pasteurized$(at\;90^{\circ}C\;for\;20\;sec)$ by three methods: by heating in a stainless steel tube immersed in a hot water bath(MP0), by heating in a microwave cavity to a defiled temperature and then holding in a hot water bath(MP1), and by both heating and holding in a microwave cavity(MP2). The microbial quality based on the total plate count was in the order of MP0, MP2 and MP1. The three samples pasteurized by different methods showed the similar microbial quality with respect to the coliform count, psychrotrophic bacterial count and phosphatase activity. The destruction of trypsin inhibitor was in the order of MP0, MP1 and MP2. There were no significant differences in pH, titratable acidity, viscosity and vitamin $B_2$ content before and after pasteurization and among the different pasteurization methods. The similar or higher quality retention of the MP1 or MP2 supports the possibility of using microwave energy for the HTST pasteurization of soymilk and other fluid food products.

  • PDF

Comparison of mycorrhizal fungi associated with Pinus species in cultural characteristics and artificial mycorrhizal synthesis on Pinus thunbergii seedlings (소나무류 균근균의 배양적 특성비교 및 인공접종에 의한 해송묘목에의 균근협성)

  • Lee, Jong Kyu;Lee, Hoon Yong;Lee, Sang Yong
    • Journal of Forest and Environmental Science
    • /
    • v.15 no.1
    • /
    • pp.77-88
    • /
    • 1999
  • This experiment was carried out to compare the cultural characteristics of mycorrizal fungi associated with Pinus species, and to form mycorrhizal association with Pinus thunbergii by artificial inoculation of these fungi. Mycorrhizal fungi tested showed great variations in cultural characteristics. Most fungal isolates was best grown on MP medium, except PDA for Lepista sp.(Ln73/92). Hagem for Rhizopogon rubescens(FRI91017), and FDA for Paxillus sp.(Pa60/92). Optimum temperature for these fungi was $25^{\circ}C$, except $30^{\circ}C$ for Pisolithus tinctorius(FRI91004 and Pt1). The range of pH conditions favorable for these fungal isolates were also variable from weak acidic(pH5) to weak alkalic(pH8). Utilization of the carbon sources for these mycorrhizal fungi was different. Fructose, glucose, and maltose were all utilized well, while xylose was not utilized generally. Mycelial growth on the media supplemented with potassium nitrate was better than those on other media with urea, asparagine, or peptone as a nitrogen source, and the poor growth was observed on the media with urea. Pisolithus tinctorius(Pt1) among 7 mycorrhizal fungi artificially inoculated for the mycorrhizal synthesis on pinus thunbergii seedlings in the test tube containing a mixture of peat moss-vermiculite(2:1, v/v) formed mycorrhizae successfully after 3 months. P. tinctorius formed branched and unbranched roots covered with thick fungal mantle and radiating extemal hyphae. Mycorrhizal root cross-sectioned by hand, stained, and observed by Nomarski interference microscope showed typical characteristics of ectomycorrhizae: fungal mantle on epidermal cells and thick Hartig net hyphae around cortex cells.

  • PDF