• Title/Summary/Keyword: Tube current

Search Result 926, Processing Time 0.033 seconds

Development of a Small Animal CT using a Linear Detector Array and Small-Scale Slip Rings

  • An Ung Hwan;Chun In Kon;Lee Sang Chul;Cho Min Hyoung;Lee Soo Yeol
    • Journal of Biomedical Engineering Research
    • /
    • v.26 no.1
    • /
    • pp.43-47
    • /
    • 2005
  • We have developed a small bore x-ray CT for small animal imaging with a linear x-ray detector array and small-scale slip rings. The linear x-ray detector array consists of 1024 elements of 400□m×400□m with a gadolinium oxysulfide (GOS) scintillator on top of them. To avoid use of expensive large diameter slip rings for projection data transmission from the X­ray detector to the image reconstruction system, we used the wireless LAN technology. The projection data are temporally stored in the data acquisition system residing on the rotating gantry during the scan and they are transmitted to the image reconstruction system after the scan. With the wireless LAN technology, we only needed to use small-scale slip rings to deliver the AC electric power to the X-ray generator and the power supply on the rotating gantry. The performances of the small animal CT system, such as SNR, contrast, and spatial resolution, have been evaluated through experiments using various phantoms. It has been experimentally found that the SNR is almost linearly proportional to the tube current and tube voltage, and the minimum resolvable contrast is less than 30 CT numbers at 40kVp/3.0㎃. The spatial resolution of the small animal CT system has been found to be about 0.9Ip/㎜. Postmortem images of a piglet is also presented.

Determinants of neural tube defect (NTD)-protective circulating concentrations of folate in women of child-bearing age in the US post-folic acid fortification era

  • Piyathilake, Chandrika;Eom, Sang Yong;Hyun, Taisun;Badiga, Suguna;Robinson, Constance;Rahman, Nuzhat;Kim, Heon;Johanning, Gary L.
    • Nutrition Research and Practice
    • /
    • v.7 no.4
    • /
    • pp.315-325
    • /
    • 2013
  • We evaluated folate status of child-bearing age women diagnosed with abnormal pap smear in the US post-folic acid (FA) fortification era and assessed the determinants of NTD-protective and supra-physiologic (SP) concentrations of folate. The distribution of 843 women according to NTD-protective concentrations of RBC folate, plasma folate and SP concentrations of plasma folate were tested in relation to demographic and life-style factors. Logistic regression models specified NTD-protective concentrations of RBC and plasma folate or SP concentrations of plasma folate as dependent variables and demographic and life-style factors as independent predictors of interest. More than 82% reached NTD-protective concentrations of RBC and plasma folate and ~30% reached SP concentrations of plasma folate. FA supplement use was associated with having SP concentrations of plasma folate rather than NTD-protective concentrations of folate. African American (AA) women and smokers were significantly less likely to achieve NTD-protective concentrations of RBC and plasma folate. A large majority of women reached NTD-protective concentrations of folate with the current level of FA fortification without using supplementary FA. Therefore, the remaining disparities in AA women and in smokers should be addressed by targeted individual improvements in folate intake.

Boiling Heat Transfer Characteristics of R-290 in Horizontal Minichannel (수평미세관내 R-290의 비등열전달 특성)

  • Choi, Kwang-Il;Pamitran, A.S.;Oh, Jong-Taek
    • Proceedings of the SAREK Conference
    • /
    • 2006.06a
    • /
    • pp.68-73
    • /
    • 2006
  • The present paper deals with an experimental study of boiling heat transfer characteristics of R-290, and is focused on pressure gradient and heat transfer coefficient of the refrigerant flow inside horizontal smooth minichannel with inner diameter of 3.0 mm and length of 2000 mm. The direct heating method applied for supplying heat to the refrigerant where the test tube was uniformly heated by electric current which was applied to the tube wall. The experiments were conducted with R-290 with purity of 99.99% at saturation temperature of 0 to $10^{\circ}C$. The range of mass flux is $50{\sim}250kg/m^2s$ and heat flux is $5{\sim}20kW/m^2$. The heat transfer coefficients of R-290 increases with increasing mass flux and saturation temperature, wherein the effect of mass flux is higher than that of the saturation temperature, whereas the heat flux has a low effect on increasing heat transfer coefficient. The significant effect of mass flux on heat transfer coefficient is shown at high quality, the effect of heat flux on heat transfer coefficient at low quality shows a domination of nucleate boiling contribution. The heat transfer coefficient of the experimental result was compared with six existing heat transfer coefficient correlation. Zang et al.'s correlation(2004) gave the best prediction of heat transfer coefficient.

  • PDF

Case study of immersed tunnel for preservation of ecological environment (생태환경 보존을 위한 침매터널 사례연구)

  • Ahn, Sung Kwon;Lee, Hee Up
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.24 no.6
    • /
    • pp.679-697
    • /
    • 2022
  • Having an awareness of the ongoing conception of Honam-Jeju, Korea-Japan, and Korea-China subsea tunnels for accommodating the railway, this paper investigates immersion tube tunnel technology, one of the underwater tunnel construction methods. This paper analyses the current status of immersed tube tunnels according to their location and function. This paper summarises the dredging methods and briefly introduces the muck disposal facility. Also introduced are the case studies where measures were taken to mitigate the impact of dredging on the surrounding marine environment. This paper also explains how the tunnel elements are connected underwater using an immersion joint. This paper classifies the foundation methods into bedding and ground improvement methods and provides summaries, including their environmental impact associated with drill cuttings and cementitious binders.

An investigation on the improvement of neutron radiography system of the Tehran research reactor by using MCNPX simulations

  • Amini, Moharram;Zamzamian, Seyed Mehrdad;Fadaei, Amir Hossein;Gharib, Morteza;Feghhi, Seyed Amir Hosein
    • Nuclear Engineering and Technology
    • /
    • v.53 no.10
    • /
    • pp.3413-3420
    • /
    • 2021
  • Applying the available neutron flux for medical and industrial purposes is the most important application of research reactors. The neutron radiography system is used for non-destructive testing (NDT) of materials so that it is one of the main applications of nuclear research reactors. One of these research reactors is the 5 MW pool-type light water research reactor of Tehran (TRR). This work aims to investigate on materials and location of the beam tube (BT) of the TRR radiography system to improve the index parameters of BT. Our results showed that a through-type BT with 20 cm thick carbon neutron filter, 1.2 cm and 9.4 cm of the diameter of inlet (D1) and output (D2) BT, respectively gives thermal neutron flux almost 25.7, 5.6 and 1.1 times greater than the former design of the TRR (with D1 = 1.8 cm and D1 = 9.4 cm), previous design of the TRR with D1 = 3 cm and D1 = 9.4 cm, and another design with D1 = 5 cm and D1 = 9.4 cm, respectively. Therefore, the design proposed in this paper could be a better alternative to the current BT of the TRR.

Development of the Novel Intraoperative Neuromonitoring for Thyroid Surgery (갑상선 수술을 위한 새로운 수술 중 신경감시시스템의 개발)

  • Sung, Eui Suk;Lee, Byung Joo
    • International journal of thyroidology
    • /
    • v.11 no.2
    • /
    • pp.109-116
    • /
    • 2018
  • It is very important to identify recurrent laryngeal nerve (RLN) and prevent RLN injury during thyroid surgery. The intraoperative neuromonitoring (IONM) for the prevention of RLN injury is a useful method because it can identify the location and status of RLN and predict postoperative vocal cord function easily. The IONM consists of a stimulating side that applies electrical stimulation to the nerve and a recording side that measures the surface electromyography (EMG) of the vocal cord muscle through electrode endotracheal tube. The nerve stimulator and surgical dissector are separate instruments. So, during IONM for the prevention of the RLN injury in conventional, endoscopic, or robotic thyroid surgery, repeated exchanging between surgical instruments and the nerve stimulator is inconvenient and time consuming. On the recording side, the accuracy of the electrode endotracheal tube which measures the EMG of the vocalis muscle can be affected by contact with between electrode and vocal fold and position change of patient. We would like to introduce recent several researches to overcome the current limitations of IONM.

Education of media by production of image contents - Focusing on Non-Linear Editing (영상 콘텐츠 제작을 통한 미디어 교육 - 비선형 편집을 중심으로)

  • Park, Sung-Dae
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.23 no.9
    • /
    • pp.1096-1103
    • /
    • 2019
  • Today the influence of digital video media grows bigger due to the development of information and telecommunication gradually and most of juveniles spend a number of image contents with their smart phones and computers. And they not only consume such image contents but also upload the videos they make at YouTube or Vimeo by recording and editing them by themselves. As we learned from such phenomenon, the education of media that uses and expresses the video in various environment such as making, reading and expressing video media is very important. The education of using the advance digital device and software of producing image contents is essential as current education of media cannot be discussed without that. This study treats the education of media based on the view point of education on image contents production. It discusses the education method that we can learn from the process of image contents production based on Non-Linear Editing System.

Preliminary Study (1) for Development of Computed Radiography (CR) Image Analysis according to X-ray Non-destructive Test by Wood Species (Computed Radiograhpy (CR)를 통한 목재 수종별 X선 투과 이미지 해석을 위한 기초연구 (1))

  • Song, Jung Il;Kim, Han Seul
    • Journal of Conservation Science
    • /
    • v.37 no.3
    • /
    • pp.220-231
    • /
    • 2021
  • The use of digital copies of film-based analog images and the introduction of digital radiographic imaging systems using image plates gradually replace the non-destructive radiationirradiation method of Cultural Heritage. The quality of images obtained from this technique is affected by conditions such as tube voltage, tube current, and exposure time, type of image acquisition medium, distance of the artifacts from the image acquisition medium, and thickness of artifacts. In this study, we evaluated the grayscale image obtained using GE's Computed Radiograhpy (CR) imaging system, the transmission characteristics of the X-ray source for each tree type (pine, chestnut, sawtooth oak, ginkgo) used in wooden Cultural Heritage, and the signal-to-noise ratio (SNR) and contrast. The GE's CR imaging were analyzed using the Duplex wire image quality indicator, line-pair gauges.

Effects of Exposure Dose Reduction by Optimization of Automatic Exposure Control Factors in Digital Radiographic Examination of Paranasal Sinus (부비동 디지털 엑스선검사에서 자동노출제어 조절인자의 최적화를 통한 조사선량 감소 효과)

  • Jeong, Min-Gyu;Seoung, Youl-Hun
    • Journal of radiological science and technology
    • /
    • v.44 no.3
    • /
    • pp.173-181
    • /
    • 2021
  • The purpose of this study was to reduce dose while maintaining image quality during digital radiographic examination of paranasal sinus by using the automatic exposure control (AEC) system. The tube voltage was set as six stages that increased by about 10 kVp to 70 kVp, 81 kVp, 90 kVp, 102 kVp, 109 kVp and 117 kVp. And then the AEC system conditions were consisted of 9 setting environments, that change mode of the sensitivity (S200, S400, S800) and the density (+2.5, 0, -2.5). We measured automatically exposed tube current (mAs) under 54 conditions with combined these, and assessed SNR and PSNR through the acquired images. In addition, four radiologists performed a qualitative assessment of the acquired images for each combination on a five-point scale of the Likert. As a result, the lowest dose and the highest values of SNR and PSNR in images with a qualitative assessment more than 4 point were the AEC control factors of 90 kVp, S800, D2.5. We applied this condition to the clinical trial, it showed an effect of 83.1% reduction in exposure radiation dose (mR). Therefore, AEC system could be used as dose reduction technology if it understood and used related regulatory factors and physical characteristics.

CBCT imaging and histopathological characteristics of osteoradionecrosis and medication-related osteonecrosis of the jaw

  • Ogura, Ichiro;Minami, Yoshiyuki;Ono, Junya;Kanri, Yoriaki;Okada, Yasuo;Igarashi, Kensuke;Haga-Tsujimura, Maiko;Nakahara, Ken;Kobayashi, Eizaburo
    • Imaging Science in Dentistry
    • /
    • v.51 no.1
    • /
    • pp.73-80
    • /
    • 2021
  • Purpose: The purpose of this study was to evaluate the cone-beam computed tomographic (CBCT) imaging and histopathological characteristics of osteoradionecrosis(ORN) and medication-related osteonecrosis of the jaw(MRONJ). Materials and Methods: Ten surgical specimens from segmental mandibulectomy (3 ORN and 7 MRONJ) were analyzed using CBCT. The CBCT parameters were as follows: high-resolution mode (tube voltage, 90.0 kV; tube current, 4.00 mA; rotation time, 16.8 s; field of view, 56 mm×56 mm; thickness, 0.099 mm). Histopathological characteristics were evaluated using histological slides of the surgical specimens. The Pearson chi-square test was used to compare ORN and MRONJ in terms of CBCT findings(internal texture, sequestrum, periosteal reaction and cortical perforation) and histopathological characteristics(necrotic bone, inflammatory cells, reactive bone formation, bacteria, Actinomyces, and osteoclasts). A P value less than 0.05 was considered to indicate statistical significance. Results: MRONJ showed periosteal reaction on CBCT more frequently than ORN (7 of 7 [100%] vs. 0 of 3 [0%], P<0.05). Regarding histopathological characteristics, MRONJ showed osteoclasts more frequently than ORN (6 of 7 [85.7%] vs. 0 of 3 [0%], P<0.05). Conclusion: This study evaluated the CBCT imaging and histopathological characteristics of ORN and MRONJ, and the findings suggest that CBCT could be useful for the evaluation of ORN and MRONJ.