• 제목/요약/키워드: Tube current

검색결과 921건 처리시간 0.03초

Bi-2223/Ag 고온 초전도 선재 변형에 따른 입계전류 특성 (Critical Current Properties of Bi-2223/Ag tapes with respect to axial Strain)

  • 하홍수;오상수;하동우;심기덕;김상철;장현만;권영길;류강식
    • 한국전기전자재료학회논문지
    • /
    • 제14권1호
    • /
    • pp.69-73
    • /
    • 2001
  • In this study, we fabricated Bi-2223/Ag high temperature superconducting tapes using PIT(Powder-In-Tube) process to apply the superconducting magnet, cable and etc. It is inevitable to deform the superconducting taps with axial strain for application. Therefore, for the characterization of the strain sensitivity of the superconducting properties, the degradation of Bi-2223/Ag tapes due to axial strain were investigated by measuring the critical current as a function of applied tension strain and external magnetic field. The critical current of Bi-2223/Ag tapes were decreased slightly up to 0.3∼0.4% applied strain but, drastically decreased more than these strains. Superconducting filament cores consisted of brittle ceramic fibers were broken easily by the large strain and current path were decreased simultaneously.

  • PDF

와전류감쇠의 모델링 및 특성 실험에 관한 연구 (A study on Modeling and Experiments of an Eddy Current Damping)

  • 박정삼;곽동기;배재성;황재혁
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2008년도 춘계학술대회논문집
    • /
    • pp.250-254
    • /
    • 2008
  • Eddy currents are induced when a nonmagnetic conductive material is moving subjected to the magnetic field due to a permanent magnet. These currents circulates in the conductive material and are dissipated, causing a repulsive force between the magnet and the conductor. Using this concept, the eddy current damping can be used as a viscous damping. The present study investigates the characteristics of a magnetic damping analytically and experimentally. The theoretical model of a eddy current damping is developed from electromagnetics and is verified from experiments. The drop test of a magnet in the cooper tube shows that the present model can accurately predict the damping force. Additionally, the dynamic test of a eddy current damping is carried to verify the present model.

  • PDF

Bi-2223 고온초전도 선재의 임계전류 향상에 관한 연구 (A study on Improvement of Critical Current for Bi-2223 HTS Tapes)

  • 하홍수;정종만;이남진;장현만;하동우;오상수;권영길;류강식
    • 한국초전도저온공학회:학술대회논문집
    • /
    • 한국초전도저온공학회 2000년도 KIASC Conference 2000 / 2000년도 학술대회 논문집
    • /
    • pp.3-5
    • /
    • 2000
  • Among the various processing techniques used in HTS wire fabrication, the PIP(Powder In Tube) method is currently one of the most promising for applications on an industrial scale. In this study, we have fabricated Bi-2223/Ag superconducting tapes using the modified PIT process, where several process factors were changed and improved, ie., powder packing, drawing, rolling and heat treatment. We obtained Bi-2223 tape that have high critical current, 46 a at 77.3 K, have high critical current, 46A at 77.3 K, self field although the tape was not pressed but only rolled. The critical current of 100m class long length tape was measured 21.6A at the same criterion. Besides, the critical current of Bi-2223/Ag tape was measured applying magnetic fields with different directions at various temperatures.

  • PDF

Bi-2223/Ag 고온초전도 선재의 변형에 따른 임계전류 특성 (Critical Current Properties of Bi-2223/Ag tapes with respect to axial Strain)

  • 하홍수;오상수;하동우;심기덕;김상철;배성우;권영길;류강식
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2000년도 하계학술대회 논문집
    • /
    • pp.810-813
    • /
    • 2000
  • In this study, we fabricated Bi-2223/Ag high temperature superconducting tapes using PIT (Powder-In-Tube) process to apply the superconducting magnet, cable and etc. It's inevitable to deform the superconducting tapes with axial strain for application. Therefore, for the characterization of the strain sensitivity of the superconducting properties, the degradation of Bi-2223/Ag tapes due to axial strain were investigated by measuring the critical current as a function of applied tension strain and external magnetic field. The critical current of Bi-2223/Ag tapes were decreased slightly up to 0.3∼0.4% applied strain but, drastically decreased more than these strains. Superconducting filament cores consisted of brittle ceramic fibers were broken easily by the large strain and current path were decreased simultaneously.

  • PDF

플라즈마 삽입전극의 전류에 미치는 밀도 구배의 영향 (Influence of the Density Gradient on the Current of the Electrode Immersed in the Non-uniform Plasma)

  • 황휘동;구치욱;정경재;최재명;김곤호;고광철
    • 한국전기전자재료학회논문지
    • /
    • 제24권6호
    • /
    • pp.504-509
    • /
    • 2011
  • The conducting current of non-uniform plasma immersed electrode consists of ion current and secondary electron emission current caused by the impinging ion current. The ion current is determined by the ion dose passing through the sheath in front of electrode and the ion distribution in front of the electrode plays an important role in the secondary electron emission. The investigation of the distributed plasma and secondary electron effect on electrode ion current was carried out as the stainless steel electrode plugged with quartz tube was immersed in the inductively coupled Ar plasma using the antenna powered by 1 kw and the density profile was measured. After that, the negative voltage was applied by 1 kV~6 kV to measure the conduction current for the analysis of ion current.

손마사지가 폐엽 절제술 환자의 흉관 제거시 통증과 불안에 미치는 영향 (The Effect of Hand Massage on Pain and Anxiety Related to Chest Tube Removal in Patients with a Lobectomy)

  • 송영숙
    • 기본간호학회지
    • /
    • 제9권1호
    • /
    • pp.27-44
    • /
    • 2002
  • The main purpose of this study was to identify the effect of hand massage on pain and anxiety related to chest tube removal in patients with a lobectomy. The research design of this study was a nonequivalent control group non-synchronized design. Of the twenty nine adult subjects, fourteen were assigned to the experimental group and fifteen to the control group. The data were obtained over 3 months from a medical center in Seoul. The instruments used to assess trait state anxiety was the Spielberger Trait-State anxiety Inventory. For pain and psychological anxiety. The Visual Analogue Scale was used. Hiko analogue sphygmo-manometer(2001) was used to check blood pressure and pulse rate as indicators of physiological anxiety Subjects in the experimental group received hand massage for 5 minutes just before chest tube was removed, and subjects assigned to the control group did not receive hand massage. Data were analysed with $x^2$-test and Mann-Whitney U test using the SPSSWIN 10.0 program. The results of the study are as follows : 1. Hypothesis 1: 'there will be a significant difference between two groups in the level of pain after chest tube removal' was supported (u = 23.00, p < 0.001). 2. Hypothesis 2: 'there will be a significant difference between the two groups in the level of psychological anxiety after chest tube removal' was supported (u = 3.00, p < 0.001). 3. Hypothesis 3: 'there will be a significant difference between the two groups in physiological anxiety(systolic, diastolic blood pressure and pulse rate) after chest tube removal' was supported(u =55.50, p = 0.01 ; u = 41.50, p = 0.01 ; u = 20.50, p < 0.001, relatively). The findings of this study indicate that hand massage is effective for pain and anxiety related to chest tube removal in patients with lobectomy. Therefore, hand massage is recommended as an effective nursing intervention for relieving pain and anxiety in patients undergoing chest tube removal. Further research is needed to identify the proper duration and timing to achieve the optimal effect of hand massage. A larger subject population is required to apply the current findings to the general population. Further research is also needed to assess the effects of hand massage in other patient subsets. Finally, it would be interesting to see if the effects of hand massaging would be attenuated when performed by a non-medical specialist.

  • PDF

Magnitude of beam-hardening artifacts produced by gutta-percha and metal posts on cone-beam computed tomography with varying tube current

  • Gaeta-Araujo, Hugo;Nascimento, Eduarda Helena Leandro;Fontenele, Rocharles Cavalcante;Mancini, Arthur Xavier Maseti;Freitas, Deborah Queiroz;Oliveira-Santos, Christiano
    • Imaging Science in Dentistry
    • /
    • 제50권1호
    • /
    • pp.1-7
    • /
    • 2020
  • Purpose: This study was performed to evaluate the magnitude of artifacts produced by gutta-percha and metal posts on cone-beam computed tomography (CBCT) scans obtained with different tube currents and with or without metal artifact reduction (MAR). Materials and Methods: A tooth was inserted in a dry human mandible socket, and CBCT scans were acquired after root canal instrumentation, root canal filling, and metal post placement with various tube currents with and without MAR activation. The artifact magnitude was assessed by the standard deviation (SD) of gray values and the contrast-to-noise ratio (CNR) at the various distances from the tooth. Data were compared using multi-way analysis of variance. Results: At all distances, a current of 4 mA was associated with a higher SD and a lower CNR than 8 mA or 10 mA (P<0.05). For the metal posts without MAR, the artifact magnitude as assessed by SD was greatest at 1.5 cm or less (P<0.05). When MAR was applied, SD values for distances 1.5 cm or closer to the tooth were reduced (P<0.05). MAR usage did not influence the magnitude of artifacts in the control and gutta-percha groups(P>0.05). Conclusion: Increasing the tube current from 4 mA to 8 mA may reduce the magnitude of artifacts from metal posts. The magnitude of artifacts arising from metal posts was significantly higher at distances of 1.5 cm or less than at greater distances. MAR usage improved image quality near the metal post, but had no significant influence farther than 1.5 cm from the tooth.

관전류 변화에 따른 면적선량과 영상 농도 평가 (Evaluation of Area Dose Product and Image Density according to the Variable Tube Current)

  • 윤영우;제재용
    • 한국방사선학회논문지
    • /
    • 제12권5호
    • /
    • pp.645-650
    • /
    • 2018
  • 본 연구는 면적선량에 따른 영상의 농도를 측정하여 피폭선량에 대한 정도관리 필요성을 제시하고자 하였다. 관전압을 80 kVp로 고정하고 관전류를 1, 25, 50, 80, 100 mAs로 조사한 결과 면적선량은 25 mAs에서 50 mAs로 증가하면 1.88배의 선량이 증가하고 50 mAs에서 100 mAs로 증가하면 2.05배 증가하였다. 하지만 필름으로 획득한 영상의 농도는 25 mAs에서 50 mAs로 증가하면 48% 증가하고, 50 mAs에서 100 mAs로 증가하면 29% 증가하였다. 또한 DR 영상의 농도는 25 mAs에서 50 mAs로 증가하면 12% 증가하고, 50 mAs에서 100 mAs로 증가하면 30% 증가하는 것으로 나타났다. 즉, 디지털 영상촬영 장비는 적정 촬영 조건에서 선량 증가에 따른 영상의 농도차이가 필름 영상보다는 적게 나타났다. 본 연구의 결과에서 디지털 영상 촬영 장비를 사용하는 의료기관에서는 방사선 선량에 대한 정도관리를 통하여 현재보다 촬영 부위별 피폭선량을 조금이나마 더 줄일 수 있을 것으로 판단되어진다.

T/R코일프로브를 이용한 원전 SG세관 검사의 와전류탐상 신호해석 (Signal Analysis of Eddy Current Test Using T/R Coil Probe for Inspection of Steam Generator Tube in NPP)

  • 임건규;이향범
    • 조명전기설비학회논문지
    • /
    • 제22권4호
    • /
    • pp.159-165
    • /
    • 2008
  • 본 논문에서는 전자기 유한요소 해석을 통하여 배열와전류프로브의 T/R 코일의 와전류탐상 특성을 해석하였다. 신호해석을 위해 사용된 결함은 Notch 결함이며, 결함의 깊이는 관두께를 기준으로 40[%]로 하였으며, 결함의 위치는 관의 내부 및 외부에 있는 것으로 하였다. Transmit 코일을 중심으로 Receive 코일의 위치를 원주방향으로 $0[^{\circ}]$, $30[^{\circ}]$, $60[^{\circ}]$, $90[^{\circ}]$에 위치시키면서 신호해석을 수행하였다. 프로브의 전자기적 특성을 해석하기 위하여 맥스웰 방정식을 이용하여 지배방정식을 유도하였고, 이를 3차원 유한요소법을 이용하여 수치 해석을 수행하였다. 두 종류 결함의 수치해석 비교 결과 내부결함의 신호가 외부결함보다 크게 발생하였고, Transmit 코일에 대한 Receive 코일의 각도 및 위치 변화시 결함신호의 차이를 확인할 수 있었다. ASME 표준 시험편을 이용한 배열와전류 프로브의 와전류탐상 실험신호와 비교결과 유사한 신호를 확인할 수 있었다. 본 논문의 결과는 배열와전류 프로브의 와전류 탐상 신호 평가시 도움이 될 것이다.