• Title/Summary/Keyword: Tube array

Search Result 142, Processing Time 0.027 seconds

The Convective Heat Transfer for the Flow Perpendicular to the Tube Array (튜브배열 방향과 수직한 유동에 의한 관외 대류 열전달)

  • Jeon Yong-Han;Kim Jong-Yoon;Kim Nam-Jin;Kim Chong-Bo
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.18 no.8
    • /
    • pp.656-663
    • /
    • 2006
  • The convective heat transfer on the outer surface of tube arrays perpendicular to the flow direction was experimentally investigated. The test sections which include the aligned and staggered arrangements were made and the local heat transfer coefficients on the outer surface of the tube were measured after the flow has been fully developed. The results showed that the local heat transfer coefficients of the staggered arrangement, which has transverse pitch of 0.075 m and longitudinal pitch of 0.08 m, were about 15% greater than that of the aligned arrangement. Also, the overall mean Nusselt number of the former was greater than that of the latter. It is verified that the results obtained by using the simulation show the same tendency with those of experiment.

A Study on the Performance of a Cross-Flow Beat Exchanger by Tube Array Change (튜브배열 변화에 따른 직교류형 열교환기의 성능에 관한 연구)

  • Jeon Yong-Han;Kim Nam-Jin;Kim Chong-Bo
    • Journal of Energy Engineering
    • /
    • v.15 no.1 s.45
    • /
    • pp.28-34
    • /
    • 2006
  • The convective heat transfer on the outer surface of tube arrays perpendicular to the flow direction was experimentally investigated. The test sections which include the aligned and staggered arrangements were made and the local heat transfer coefficients on the outer surface of the tube were measured after the Hour has been fully developed. The results showed that the local heat transfer coefficients of the staggered arrangement, which has transverse pitch of 0.075 m and longitudinal pitch of 0.08 m, were about 15% greater than that of the aligned arrangement. Also, the overall mom Nusselt number of the former was greater thu that of the latter.

Performance Estimation and Test of Protype Pulse Tube Cryopump (맥동관형 크라이오펌프 시제품 성능예측과 평가)

  • In, Sang Ryul;Kang, Sang Paek
    • Journal of the Korean Vacuum Society
    • /
    • v.22 no.2
    • /
    • pp.45-54
    • /
    • 2013
  • The cryopump of the pulse tube type has been developed successfully, and manufacturing of a prototype pump is finished under leading of Woosung Vacuum. The target pumping speed of the prototype pump is above 3,600 L/s for nitrogen with the intake port of 14 inches I.D (16 inches O.D). For designing optimally the pump structure including the charcoal array, thermal shield, and baffle, the pumping speed was simulated for various configurations through Monte Carlo method. Pumping performances of the protype cryopump manufactured on the basis of optimal design were conformed experimentally with a standard test system and procedures. The measured $N_2$ pumping speed of the prototype cryopump was 4,600 L/s which agreed well with simulated one and exceeded the target value.

CCFL Backlight characterization using luminance meter and image analysis.

  • Gibour, Veronique;Boher, Pierre;Leroux, Thierry
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.791-794
    • /
    • 2004
  • In this article, we present a method to measure precisely the performances of direct-lit CCFL backlights using a luminance meter and dedicated image analysis software. The array of CCFL tubes alone can be measured directly and the luminance of each tube can be extracted along its main dimension. So, comparison of the different tubes on the same backlight can be made easily and the performances in terms of backlight uniformity improved. The influence of the diffuser sheet can be probed in the same way and the homogeneity of the entire surface of the backlight can be automatically extracted and quantified.

  • PDF

Optimization Design of Large Gas Oven Systems (대형 가스오븐 시스템의 최적 설계)

  • Kim, Dohyun;Yu, Byeonghun;Kum, Sungmin;Lee, ChangEon
    • 한국연소학회:학술대회논문집
    • /
    • 2015.12a
    • /
    • pp.205-207
    • /
    • 2015
  • In this study, we examined through experimental study of the combustion conditions in order to optimize the 20,000kcal/hr class combustor being used in the commercial large gas oven. Through a consideration of the shape and the heat transfer area of the heat exchanger that is suitable for supplying heat quantity is designed and manufactured two heat exchangers were examined cooking chamber temperature change of the oven by the convection fan control method through advanced research.

  • PDF

Development of Airborne High Density High Voltage Power Supply for Traveling Wave Tubes

  • Park Young-Ju
    • Journal of Power Electronics
    • /
    • v.5 no.4
    • /
    • pp.257-263
    • /
    • 2005
  • This paper describes the development and testing results of a high density High Voltage Power Supply (HVPS) that drives microwave Traveling Wave Tubes (TWTs) of phased array transmitters for airborne EW systems. The HVPS is designed to consist of a number of modules connected in series. Among them, especially, the high-density pulse transformer module including the resonant circuit is newly designed to make the HVPS much more reliable. In addition, this paper describes the development of high voltage solid-state modulation using fast switching devices (FETs) and also represents the test results of a modulator module.

Assessment of Leak Detection Capability of CANDU 6 Annulus Gas System Using Moisture Injection Tests

  • Nho, Ki-Man;Kim, Wang-Bae;Sim, Woo-Gun
    • Nuclear Engineering and Technology
    • /
    • v.30 no.5
    • /
    • pp.403-415
    • /
    • 1998
  • The CANDU 6 reactor assembly consists of an array of 380 pressure tubes, which are installed horizontally in a large cylindrical vessel, the Calandria, containing the low pressure heavy water moderator. The pressure tube is located inside the calandria tube and the annulus between these tubes, which forms a closed loop with $CO_2$ gas recirculating, is called the Annulus Gas System(AGS). It is designed to give an alarm to the operator even for a small pressure tube leak by a very sensitive dew point meter so that he can take a preventive action for the pressure tube rupture incident. To judge whether the operator action time is enough or not in the design of Wolsong 2,3 & 4, the Leak Before Break(LBB) assessment is required for the analysis of the pressure tube failure accident. In order to provide the required data for the LBB assessment of Wolsong Units 2, 3, 4, a series of leak detection capability tests was performed by injecting controlled rates of heavy water vapour. The data of increased dew point and rates of rise were measured to determine the alarm set point for the dew point rate of rise of Wolsong Unit 2. It was found that the response of the dew point depends on the moisture injection rate, $CO_2$ gas flow rate and the leak location. The test showed that CANDU 6 AGS can detect the very small leaks less than few g/hr and dew point rate of rise alarm can be the most reliable alarm signal to warn the operator. Considering the present results, the first response time of dew point to the AGS $CO_2$ flow rate is approximated.

  • PDF

A New Small Size Digital Optical Ozone Monitor Using CCD Array as a UV Detector (UV 감지기로서 CCD어레이를 사용한 소형 디지털 광 오존모니터)

  • Chung, Wan-Young;Lee, Seung-Chul
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.12 no.1
    • /
    • pp.158-163
    • /
    • 2008
  • Ozone monitor based on UV techniques has been widely used due to their signal stability. The high concentration ozone monitor for real time ozone monitoring from ozone generator was composed of a low pressure mercury lamp as UV source and a photo multiplier tube as UV detector. The structure could be very useful for low price high concentration ozone monitor and showed good linearity to ozone in the concentration range between 0.05 and 2wt%. For accurate ambient ozone monitoring, the system composed of a high power pulsed xenon lamp as UV source, an optical spectrometer with a high sensitivity linear CCD array as UV detector. The optical signal form the CCD array was converted to digital signal, and the digital signal was displayed on screen using PC interface. The developed system showed good linearity and sensitivity in relatively low measuring range between 10ppm and 10,000ppm, and showed some feasibility of hish resolution ozone monitor using CCD array as a photodetecor.

Experimental Study about Two-phase Damping Ratio on a Tube Bundle Subjected to Homogeneous Two-phase Flow (균질 2상 유동에 놓인 관군에 작용하는 감쇠비에 대한 실험적 연구)

  • Sim, Woo Gun;Dagdan, Banzragch
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.41 no.3
    • /
    • pp.171-181
    • /
    • 2017
  • Two-phase cross flow exists in many shell-and-tube heat exchangers such as condensers, evaporators, and nuclear steam generators. The drag force acting on a tube bundle subjected to air/water flow is evaluated experimentally. The cylinders subjected to two-phase flow are arranged in a normal square array. The ratio of pitch to diameter is 1.35, and the diameter of the cylinder is 18 mm. The drag force along the flow direction on the tube bundles is measured to calculate the drag coefficient and the two-phase damping ratio. The two-phase damping ratios, given by the analytical model for a homogeneous two-phase flow, are compared with experimental results. The correlation factor between the frictional pressure drop and the hydraulic drag coefficient is determined from the experimental results. The factor is used to calculate the drag force analytically. It is found that with an increase in the mass flux, the drag force, and the drag coefficients are close to the results given by the homogeneous model. The result shows that the damping ratio can be calculated using the homogeneous model for bubbly flow of sufficiently large mass flux.

Methyl salicylate and trans-anethole affect the pheromonal activity of homofarnesal, the female sex pheromone of azuki bean beetle

  • CHILUWAL, Kashinath;KIM, Junheon;BAE, Soon Do;ROH, Gwang Hyun;PARK, Chung Gyoo
    • Entomological Research
    • /
    • v.48 no.5
    • /
    • pp.354-361
    • /
    • 2018
  • Plant essential oils (EOs) exhibit an array of biological activities against insect pests. However, their negative influences on the pheromonal activity of azuki bean beetle (ABB), Callosobruchus chinensis L. have not received research attentions. ABB is a field-to-storage pest of legumes, and its female produces the sex pheromone known as homofarnesal with two isomeric components: 2E- and 2Z-homofarnesal, (2E,6E)-7-ethyl-3,11-dimethyl-2,6,10-dodecatrienals and (2Z,6E)-7-ethyl-3,11-dimethyl-2,6,10-dodecatrienals. We evaluated the effects of three EOs and their two major components on the attractiveness of male ABBs to synthetic homofarnesal (2E-:2Z-homofarnesal = 6:4) using Y-tube olfactometry in laboratory and rocket traps in the semi-open polyhouse. Y-tube olfactometry showed the significant negative effect of EOs of Illicium verum, Croton anisatum at 10 and 100 ng, and Gaultheria fragrantissima at 100 ng against homofarnesal (100 ng) in attracting male ABBs. Similarly trans-anethole (at 10 and 100 ng) and methyl salicylate (at 100 ng) also ascertained significant negative effect against homofarnesal (100 ng) in Y-tube olfactometry. When 10 mg of each of trans-anethole and methyl salicylate was released at the downstream of 30 mg homofarnesal lure in rocket traps, highly significant effect was achieved against attractiveness of homofarnesal to ABB males. This study ascertained significant level of negative effect of the tested EOs and their major components to homofarnesal, tracing out a new opportunity of integrating them in ABB management programs both in field and storage.