• 제목/요약/키워드: Tube angle

검색결과 466건 처리시간 0.028초

브라운관 전자총 부품의 펄스 Nd:YAG레이저 용접에 관한 연구 (I) - 빔의 출력특성과 광학변수 - (A Study on Pulsed Nd:YAG Laser Welding of Electron Gun in Braun Tubes (I) - Characteristics of Beam Output Energy and Optical Parameters -)

  • 김종도;하승협;조상명
    • Journal of Welding and Joining
    • /
    • 제20권4호
    • /
    • pp.525-534
    • /
    • 2002
  • During laser spot welding of the braun tube electron gun, phenomena such as serious spattering and oxidative reaction, etc. were occurred. The spatter occurred from weld pool affects the braun tube, namely it blocks up a very small hole on the shadow mask and causes short circuit between two roles of the electron gun. We guessed that high power density and oxidative reaction are main sources of these problems. So, we studied to prevent and to reduce spatter occurring in spot welding of the braun tube electron gun using pulsed Nd:YAG laser. The characteristics of laser output power was estimated, and the loss of laser energy by optical parameter and spatter was measured by powermeter. The effects of welding parameters, laser defocused distance and incident angle, were investigated on the shape and penetration depth of the laser welded bead in flare and flange joints. From these results, the laser peak power was a major factor to control penetration depth and to occur spatter. It was found that the losses of laser energy by optic parameter and sticked spatter affect seriously laser weldability of thin sheets. The deepest penetration depth is gotten on focal position, and a "bead transition" occurred with a slight displacement of focal position relative to the workpiece surface and the absorption rate of the laser energy is affected by the shape factor of the workpiece. When we changed the incident angle of laser beam, the penetration depth was decreased a little with increasing of the incident angle, and the bead width was increased. The spattering was prevented by considering laser beam energy and incident angle.ent angle.

S-align 기능을 이용한 흉부 전·후 방향 검사 시 적절한 X선관 각도에 관한 연구 (The Study of Appropriate X-ray Tube Angle for the Anterior-posterior Chest Radiography Using S-align Function)

  • 박명주;주영철;김민석;육정원;김한용;김동환
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제45권4호
    • /
    • pp.299-304
    • /
    • 2022
  • This study uses the 'S-align' function to present a reference value of the X-ray tube angle for the realization of an image similar to that of the chest PA image during chest AP radiography. This study targeted dummy phantom and used a 17"×17" DR image receptor. The irradiation conditions were 110 kVp, 160 mA, 50 ms, and the distance between the central X-ray and the image receptor was set to 180 cm and 110 cm, respectively. The end of the catheter was placed at the 11th thoracic height to indicate the nasogastric tube. In the case of lung apex length measurement, the mean value of measurement was 30.53±0.47 in PA. T 0°, TCA 5~25°, TCE 5~15° were 21.07±0.29, 27.60±0.21, 34.13±0.44, 39.86±0.31, 45.96±0.61 mm, 54.13±0.37 mm, 16.16±0.46 mm, 9.81±0.35 mm, 2.75±0.30 mm, respectively. For the depth of the catheter end, the average value measured at PA was 6.70±0.31 mm. T 0°, TCA 5~25°, TCE 5~15° were 15.72±0.38 mm, 24.10±0.50 mm, 29.24±0.86 mm, 34.35±0.35 mm, 41.06±1.08 mm, 48.07±0.38 mm, 12.85±0.25 mm, 7.92±0.36 mm, 3.01±0.39 mm, respectively. The length of the lung apex was similar to that of chest PA when the angle of incidence was adjusted from 5° to 10° in the leg direction, and the depth of the catheter tip was most similar when the X-ray tube angle was incident at 10° in the head direction. Therefore, To change the X-ray tube angle according to the purpose of the examination during the chest AP radiography using 'S-align' function is considered necessary.

열교환기 튜브확관을 위한 맨드렐 설계 (Design of a Mandrel for Expansion of the Tube of the Heat Exchanger)

  • 강흥식;김동성
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2004년도 추계학술대회
    • /
    • pp.430-434
    • /
    • 2004
  • Specifically designed mandrel is needed to expand tube of the heat exchanger with inner grooves. Configuration of the expanded tube depends upon the shape and feeding velocity of the mandrel. 3D simulation software LS-DYNA was used to obtain optimum design conditions of the mandrel. We show how configuration of the expanded tube varies with different design parameters such as the approaching angle, diameter , and the feeding velocity of the mandrel. Material property data for analysis were obtained through experiments with SHPB ( Split Hopkinson Pressure Bars ).

  • PDF

경사모세관법(傾斜毛細管法)에 의한 산양혈액(山羊血液)의 적혈구침강율(赤血球沈降率) 측정(測定) (Angled Capillary Method for Determining Erythrocyte Sedimentation Rate of Goat)

  • 신성식;이방환;신종욱
    • 대한수의학회지
    • /
    • 제26권1호
    • /
    • pp.187-194
    • /
    • 1986
  • The purpose of this study is to develop a new method which enables the goat ESR to be used as an effective clinical test. Blood samples were taken from 61 Korean native goats aged above one year old and the effect of tube inclinations, tube bores, tube lengths, environmental temperatures during tests and packed erythrocyte volumes (PCV) on the ESR were observed. The results were summarized as follows. 1. The ESR/hr using capillary hematocrit tube (Micro-Ht-tube) was gradually increased as the tube angle inclined from 90 (vertical) to 15 degrees and the best angle in view of both security and fast sedimentation rate was found to be an angle of 45 degrees. 2. The 45-degree angled ESR ($45^{\circ}$-ESR) increased as the diameter of tube bore decreased. 3. The tube length did not affect the $45^{\circ}$-ESR in percent. 4. The $45^{\circ}$-ESR increased with the increased environmental temperature during the ESR test. 5. The heparinized Micro-Ht tubes did not affect the $45^{\circ}$-ESR of EDTA-blood in healthy group but in anemic group. In the anemic group, the ESRs by the heparinized Micro-Ht-tubes were slightly higher than those by non-heparinized Micro-Ht-tubes. 6. By using the autologous plasma, PCV of the blood was adjusted to be 10, 20, 30, 40 and 50ml/100ml and $45^{\circ}$-ESRs were determined in the Micro-Ht-tubes. The $45^{\circ}$-ESRs increased as the values of PCV decreased. The regression of the $45^{\circ}ESR$ to PCV was curvilinear with the second degree polynomial, $Y=42.1838-1.7355X+0.0180X^2$(r=0.9997). 7. The $45^{\circ}$-ESR/hr, using non-heparinized Micro-Ht-tubes at $20^{\circ}C$, was determined in 35 healthy Korean native goats. The average PCV was $30.6{\pm}1.4ml/100ml$. The observed ESR values averaged $6.8{\pm}1.7%$ and the corrected ESR values to the standard PCV of 31ml/100ml averaged $6.5{\pm}1.2%$. From these results, the angled capillary tube method was found to be desirable ESR test of goat blood in which EDTA-blood is filled in nonheparinized Micro-Ht-tubes held at an angle of 45 degrees for an hour at $20^{\circ}C$.

  • PDF

액체금속로 중간열교환기 관다발에서의 튜브배열과 경사각도가 압력강하에 미치는 영향 (The Effects of Tube Arrangement and Inclination on the Pressure Drop in Tube Bundles of Intermediate Beat Exchanger in Liquid Meta Reactor)

  • 남호윤;김종만;최종현
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2002년도 학술대회지
    • /
    • pp.659-662
    • /
    • 2002
  • The present paper presents the experimental results for pressure drop in inclined tube bundles located in a rectangular duct. Measurements are made for pressure drop in triangular and rotated triangular tube arrays having P/d ratio of 1.6 and inclination angles of 30,45,60 and 90 degrees. The Reynolds number based on the free stream velocity and tube diameter ranges from $8{\times}10^2\;to\;6.3{\times}10^{4}$. The experimental results show that the magnitude of dimensionless pressure drop decreases significantly when the inclined angle is less than 45 degree. The measured data are compared with two existing correlations available in the literatures. The ESDU correlation agrees well with the present data far the triangular arrays. But some discrepancies are observed for the rotated triangular arrays when the inclined angles are 30 and 45 degrees. The Idel'chik correlation generally agrees well with the measured data for the rotated triangular arrays except for the inclined angle of 30 degree. The Idel'chik correlation needs modification for the triangular arrays. The modified Idel'chik correlation agrees well with the measured data within $10{\%}$. It is found that the present measured data can be applied to the evaluation and modification of previous correlations.

  • PDF

A Study on the Perforating Process of the Muffer Tube using FEM

  • Han Kyu-Taek
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제29권3호
    • /
    • pp.275-280
    • /
    • 2005
  • Recently there has been a growing interest in the design and manufacturing of the muffler tube due to the strict environment regulations, A muffler is an important part used to reduce noise and to purify exhaust gas in cars and heavy equipment. The shape of the muffler tube and the number of the tube hole has been made variously according to the weight and function of the car. The perforating technique of the muffler tube has a great influence on the manufacturing cost. In this study, metal forming analysis has been carried out to investigate the perforating process for the muffler tube and predict an optimal forming conditions of the muffler tube, Also its simulation results by the finite element method were reflected to the die design and the manufacturing system for the muffler tube. The perforating process is performed in the longitudinal direction of the tube. According to the simulation results, when the shear angle of punch was similar to the tube curvature, the optimal shape was obtained. Also when the clearance of die was 0.2mm, the burr was minimized and optimal shear section was obtained.

곡관으로부터 방출되는 펄스파에 관한 실험적 연구 (An Experimental Study of the Impulsive Wave Discharged from a Curved Duct)

  • 이동훈;김희동
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 춘계학술대회논문집E
    • /
    • pp.317-322
    • /
    • 2001
  • This study depicts an experimental work of the impulsive wave discharged from the open end of several kinds of right-angle bend pipes, which are attached to the open end of a simple shock tube. The weak normal shock wave with its magnitude of Mach number from 1.03 to 1.20 is employed to obtain the impulsive wave propagating outside the open end of the bend pipes. The experimental data of the magnitude of the impulsive wave and its propagation directivity are analyzed to characterize the impulsive waves discharged from the right-angle bend pipes and compared with those from a straight pipe. The results obtained show that a right-angle miter bend considerably reduces the magnitude of the impulsive wave and its directivity toward to the pipe axis, compared with the straight pipe. It is believed that the right angle miter bend pipe can playa role of passive control against the impulsive wave.

  • PDF

와전류(渦電流) 표준침투(標準浸透) 깊이 표피효과(表皮效果)와 결함신호(缺陷信號) 위상각(位相角)의 관계해석(關係解析) (Analysis of Relationship between Standard Depth of Penetration Skin Effect and Phase Angle of Defect Signal of Eddy Current Testing)

  • 정태언;장기옥;박대영
    • 비파괴검사학회지
    • /
    • 제4권2호
    • /
    • pp.7-14
    • /
    • 1985
  • An experiment to investigate the rate of change of phase angle of eddy current output signal caused by outer surface defect of nonferromagnetic tube by variation of standard depth of penetration and variation of percent of tube wall penetration was carried out. The results of the experiment show that the phase angle of defect signal is increased with decreasing the standard depth of penetration or the depth of defect. The results also show that the phase angle is decreased with increasing the skin effect of eddy current, and that the resolution is decreased with decreasing the depth of defect.

  • PDF

Suppression of performance degradation due to cold-head orientation in GM-type pulse tube refrigerator

  • Ko, Junseok;Kim, Hyobong;Park, Seong-Je;Hong, Yong-Ju;Koh, Deuk-Yong;Yeom, Hankil
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제14권4호
    • /
    • pp.50-53
    • /
    • 2012
  • This paper describes experimental study on GM-type pulse tube refrigerator (PTR). In a PTR, the pulse tube is only filled with working gas and there exists secondary flow due to a large temperature difference between cold-end and warm-end. The stability of secondary flow is affected by orientation of cold-head and thus, the cooling performance is deteriorated by gas mixing due to secondary flow. In this study, a single stage GM-type pulse tube refrigerator is fabricated and tested. The cooing performance of the fabricated PTR is measured as varying cold-head orientation angle and the results are used as reference data. Then, we divided interior space of pulse tube into three segments, and fixed the various size of screen mesh at interface of each segment to suppress the performance degradation due to secondary flow. For various configuration of pulse tube, no-load test and heat load test are carried out with the fixed experimental condition of charging pressure, operating frequency and orifice valve turns. From experimental results, the fine screen mesh shows the effective suppression of performance degradation for the large orientation angle, but the use of screen mesh cause the loss of cooling capacity rather than the case of no insertion into pulse tube. It should be compromised whether the use of screen mesh in consideration of the installation limitation of a GM-type pulse tube refrigerator.

X-선관 각도 변경에 따른 Anode Heel Effect (The Anode Heel Effect caused by changing the Angle of X-Ray Tube)

  • 신성규;이효영
    • 한국방사선학회논문지
    • /
    • 제10권6호
    • /
    • pp.435-442
    • /
    • 2016
  • 본 연구는 X-선관 각도 변경에 따른 경사효과(Anode Heel Effect)의 변화를 알아보고자 실시하였다. 실험조건은 70 kV, 30 mAs, 초점-검출기간의 거리 100 cm, 조사야는 $35{\times}43cm^2$, 측정점은 조사야의 정중앙점에서 좌우 3.5 cm 간격으로 나누어 양극쪽으로 A1, A2, A3, A4, A5, A6 점을 설정하고 음극쪽으로 C1, C2, C3, C4, C5, C6 점으로 설정하였다. X-선관을 수직으로 하여 측정점인 A6에서 C6까지 각각 입사표면선량을 측정하였다. 다음에 X-선관을 양극쪽으로 15도 30도로 변경 하면서 각각 측정하고 같은 방법으로 음극쪽으로 15도 30도로 변화시켜 측정하였다. 결과로 X-선관이 수직인 경우 A5보다 C5점이 3배정도 입사표면선량이 높게 나타나 수직 촬영 시 방사선감수성이 높은 장기가 위치해 있는 쪽으로 양극을 위치시키면 피폭을 줄일 수 있었다. X-선관의 각도를 주고 촬영할 경우에는 음극측으로 각도를 주는 것이 양극과 음극측의 입사표면선량 차이를 줄일 수 있으며 상, 하 두께 차이가 있는 부위를 촬영할 경우에는 음극측이 두꺼운 부위를 향하게 각도를 주는 것이 입사표면선량의 차이를 줄여 좀 더 균일한 영상을 만들 수 있었다.