• Title/Summary/Keyword: Tube Specimen

Search Result 261, Processing Time 0.021 seconds

Studies on the Sex Control in Swine by the Physical Treatments on spermatozoa (정자에 대한 심리적 처리에 의한 돼지의 성비조절에 관한 연구)

  • 이용빈;임경선;서국성;오성종
    • Korean Journal of Animal Reproduction
    • /
    • v.3 no.1
    • /
    • pp.36-40
    • /
    • 1979
  • This experiment was conducted to separate X-and Y-bearing spermatozoa of boar semen. The ratio of X-and Y-bearing spermatozoa to total spermatozoa included in ejaculated semen obtained from 4 boars raising at the College of Agriculture, Seoul National University and treated by the sedimentory or electrophoretic technique was estimated. For the electrophoresis, the semen specimen was placed into the co, pp.r loop electrodes in 30cc of glass tube at room temperature for 30 minutes and in order to sedimentary separation, the semen was sedimented in 5$^{\circ}C$ water for 50 minutes. The sperm fluorescent stainning technique was performed by the method of Bhattacharya etal (1976). The results obtained were as follows; 1. Average rate of B-body bearing spermatozoa in normal boar semen was 45.15${\pm}$4.20%, and no significant difference was observed between 1st (44.88${\pm}$6.41%) and 2nd (42.75${\pm}$4.17%) fraction of fractionally collected semen. 2. Spermatozoa were separated into several different fractions by sedimentation. B-body a, pp.arances from the top and bottom fraction were 53.70% and 33.43%, respectively. There were highly significant difference between the top and bottom fractions. 3. The swine spermatozoa were separated into X-and Y-bearing spermatozos by electrophoresis without interferring the sperm motility. The rates of B-body bearing spermatozoa attracted on the anode and cathode were 60.4% and 21.8%, respectively. Highly significant difference betwee two fractions was also observed.

  • PDF

The Combustion Gases Toxicity Evaluation of Plastics Material by Colorimetric Gas Detector Tubes (가스검지관법에 의한 플라스틱재료의 연소가스 독성평가)

  • 박영근;김동일;현성호
    • Fire Science and Engineering
    • /
    • v.16 no.4
    • /
    • pp.77-84
    • /
    • 2002
  • In this paper, we had analyzed comsbustion gases using a GASTEC colorimetric gas detector tube according to the method of NES 713 in order to combustion gases toxicity evaluation for beads polystyrene foam, extruded polystyrene foam, rigid polyurethane foam, flexible polyurethane foam, flexible polyvinyl chloride pipe, vinyl floor cover, polyethyelene foam(flame retardant untreated) and polyethyelene foam (flame retardant treated) of plastics material. As results of gas analyses by using this method, comsbustion gases producted from small specimens of plastics material had reached fatal to man at 30 minutes exposure time that had possesed toxicity index of more than 1. Toxicity indexes of each specimen were estimated range of 4.3∼179.2, flexible polyvinyl chloride showed the hightest toxicity index at 179.2, and beads polystyrene foams showed the lowest toxicity index at 4.3.

HEAT-UP AND COOL-DOWN TEMPERATURE-DEPENDENT HYDRIDE REORIENTATION BEHAVIORS IN ZIRCONIUM ALLOY CLADDING TUBES

  • Won, Ju-Jin;Kim, Myeong-Su;Kim, Kyu-Tae
    • Nuclear Engineering and Technology
    • /
    • v.46 no.5
    • /
    • pp.681-688
    • /
    • 2014
  • Hydride reorientation behaviors of PWR cladding tubes under typical interim dry storage conditions were investigated with the use of as-received 250 and 485ppm hydrogen-charged Zr-Nb alloy cladding tubes. In order to evaluate the effect of typical cool-down processes on the radial hydride precipitation, two terminal heat-up temperatures of 300 and $400^{\circ}C$, as well as two terminal cool-down temperatures of 200 and $300^{\circ}C$, were considered. In addition, two cooling rates of 2.5 and $8.0^{\circ}C/min$ during the cool-down processes were taken into account along with zero stress or a tensile hoop stress of 150MPa. It was found that the 250ppm hydrogen-charged specimen experiencing the higher terminal heat-up temperature and the lower terminal cool-down temperature generated the highest number of radial hydrides during the cool-down process under 150MPa hoop tensile stress, which may be explained by terminal solid hydrogen solubilities for precipitation, and dissolution and remaining circumferential hydrides at the terminal heat-up temperatures. In addition, the slower cool-down rate generates the larger number of radial hydrides due to a cooling rate-dependent, longer residence time at a relatively high temperature that can accelerate the radial hydride nucleation and growth.

Experimental Fatigue Characteristics of Composite Bridge Deck of Hollow Section (중공단면 복합소재 교량 바닥판의 실험적 피로특성 분석)

  • Lee, Sung-Woo;Hong, Kee-Jeung
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.19 no.4 s.74
    • /
    • pp.337-345
    • /
    • 2006
  • In this study, to evaluate fatigue characteristics of developed composite bridge deck, compression fatigue test at girder support and flexural fatigue test for the 2.8m-long flexural test model were carried out. For the test specimen, DB 24 truck load was applied up to 2,000,000 cycles. In the compression fatigue test, behavior at deck tube and its bonded connection were evaluated. In the flexural fatigue test, deck behavior at mid-span and girder connection were evaluated.

Detection of Corrosion and Wall Thinning in Carbon Steel Pipe Covered With Insulation Using Pulsed Eddy Current

  • Park, Duck-Gun;Kishore, M.B.;Kim, J.Y.;Jacobs, L.J.;Lee, D.H.
    • Journal of Magnetics
    • /
    • v.21 no.1
    • /
    • pp.57-60
    • /
    • 2016
  • Non Destructive Testing (NDT) methods that are capable of detecting the wall thinning and defects through insulation and cladding sheets are necessary. In this study we developed a Pulsed Eddy Current (PEC) system to detect wall thinning of ferro magnetic steel pipes covered with 95 mm thick fiber glass thermal insulator and shielded with aluminum plate of thickness 0.4 mm. In order to confirm the thickness change due to wall thinning, two different sensors, a hall sensor and a search coil sensor were used as a detecting element. In both the cases, the experimental data indicates a considerable change in the detected pulse corresponding to the change in sample thickness. The thickness of the tube was made to change such as 2.5 mm, 5 mm and 8 mm from the inner surface to simulate wall thinning. Fast Fourier Transform (FFT) was calculated using window approach and the results were summarized which shows a clear identification of thickness change in the test specimen by comparing the magnitude spectra.

Hysteretic behavior studies of self-centering energy dissipation bracing system

  • Xu, Longhe;Fan, Xiaowei;Lu, Dengcheng;Li, Zhongxian
    • Steel and Composite Structures
    • /
    • v.20 no.6
    • /
    • pp.1205-1219
    • /
    • 2016
  • This paper presents a new type of pre-pressed spring self-centering energy dissipation (PS-SCED) bracing system that combines friction mechanisms between the inner and outer tube members to provide the energy dissipation with the pre-pressed combination disc springs installed on both ends of the brace to provide the self-centering capability. The mechanics and the equations governing the design and hysteretic responses of the bracing system are outlined, and a series of validation tests of components comprising the self-centering mechanism of combination disc springs, the friction energy dissipation mechanism, and a large scale PS-SCED bracing specimen were conducted due to the low cyclic reversed loadings. Experimental results demonstrate that the proposed bracing system performs as predicted by the equations governing its mechanical behaviors, which exhibits a stable and repeatable flag-shaped hysteretic response with excellent self-centering capability and appreciable energy dissipation, and large ultimate bearing and deformation capacities. Results also show that almost no residual deformation occurs when the friction force is less than the initial pre-pressed force of disc springs.

Performance Evaluation of Heat Radiant for 50W LED by the CNT Thermal Interface Material (CNT 열전달 물질에 의한 50W LED의 방열 성능평가)

  • Cho, Young-Tae;Lee, Choong-Ho
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.13 no.6
    • /
    • pp.23-29
    • /
    • 2014
  • In this study, cooling and heat-transfer tests are performed to compare and evaluate the thermal conductivity in a prepared CNT TIM (thermal interface material). A polymerized CNT heat-transfer resin and commercial thermal grease (Shinetsu G-747) were applied for a comparison test in both cases. Cooling experiments with an aluminum foil specimen were performed in order to measure the temperature distribution using an infrared camera, and in heat radiation experiments, performance testing of the thermal conductivity was conducted using high-power LEDs. Carbon resin with the polymerization of graphite and carbon black, and CNT-polymerized CNT resin with graphite and carbon black were tested and compared with using G-747. It was found that the cooling performance and the heat transfer ability in both the carbon resin and the CNT-polymerized CNT resin were greater than those of G-747 because the temperature by 5. $0^{\circ}C$ in both cases appeared lower than that of the G-747.

Characteristic of Critical Current after Repetitive Bending for High Superconducting Tapes (고온초전도 선재의 Bending횟수에 따른 임계전류의 특성)

  • Kim, Hae-Joon;Joo, J.H.;Kim, S.W.;Kim, H.J.;Bae, J.H.;Cho, J.W.;Seong, K.C.
    • Proceedings of the KIEE Conference
    • /
    • 2003.07b
    • /
    • pp.900-902
    • /
    • 2003
  • Critical current($I_c$) degradation of HTS tapes after bending is one of the holiest issues in HTS development and application studies. Many people are measuring $I_c$ degradations for effect of tending radius. However even if the bending radius is larger than the breaking radius a HTS tapes can be damaged by repetitive bending, which is unavoidable in the winding processes. Therefore, We studied the $I_c$ degradation after repetitive bending, at 77K with self-field, of Bi-2223 tapes processed by "Powder-in-Tube" technique, which was made by America Superconductor Corporation(AMSC), Innova Superconductor Technology(InnoST) and Korea Electro-technology Research Institute(KERI). For each specimen $I_c$ degradation was measured various bending radius as function of repetitive bending number.

  • PDF

Current Leads Fabrication of High $T_c$ Bi System Superconductor Using Rapid Cooling Method (급속응고법을 이용한 Bi 계 고온초전도체 전류도입선 제조)

  • 박용민;한진만;류운선;류운선
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.13 no.3
    • /
    • pp.254-258
    • /
    • 2000
  • Current leads of high $T_{c}$ superconductor were fabricated with Bi excess B $i_{2.2}$/S $r_{1.8}$/C $a_{1}$/C $u_{2}$/ $O_{x}$ composition by rapid cooling method. The dimensions of final samples were fixed 3 mm and 8 mm diameter with 50 mm length each To control uniform density the samples were preformed by CIP(Cold Isostatic Press) process and followed by partial or full melting process after raising up to 90$0^{\circ}C$ for 30min. Plate shaped microstructure was clearly observed adjacent to the Ag tube wall and the size of plate was about 100$\mu$m. However the severe destruction of growth orientation was shown in the inner growth part. critical temperature ( $T_{c}$) was about 53~71K after directional growth while Tc was decreased about 77~80 K before directional growth. After directional growth critical current( $I_{c}$) and critical current density( $J_{c}$) in the specimen of 8 mm diameter at 50 K were about 110 A and 280 A/c $m^2$ respectively.pectively.ely.

  • PDF

AN EXPERIMENTAL STUDY ON HARDNESS IN COMPOSITE RESINS (수종복합레진의 경도측정에 관한 실험적 연구)

  • Um, Chung-Moon
    • Restorative Dentistry and Endodontics
    • /
    • v.4 no.1
    • /
    • pp.35-38
    • /
    • 1978
  • The purpose of this study was to measure micro-knoop hardness and coefficient of thermal expansion on composite resins (Epolite, Adaptic, Hipol and Compo T.) Four different type of composite resins were measured at the varying depth of 30, 60, 90, 150, 200, 400, 700 and 1000 micron from the surface to deep portion. The specimens were stored both in the air room temperature for 2 days, 30 days and in water at $37^{\circ}C$ for 30 days. Thermal expansions of specimens(4mm in diameter and 50mm in height) were measured in quartz tube dilatometer from $20^{\circ}$ to $70^{\circ}C$ The following results were obtained. 1. The hardness of superficial portion were lower than inner portion of resin. 2. The value of hardness obtained from the specimen stored in room temperature in the water at $37^{\circ}C$ for 30 days were lower than above described Cases. 3. The coefficient of thermal expansion of Adaptic had $29.75{\times}10^{-6}/^{\circ}C$, Hipol had $30{\times}10^{-6}/^{\circ}C$, Epolite had $39.85{\times}10^{-6}/^{\circ}C$ and Compo T had $36.95{\times}10^{-6}/^{\circ}C$.

  • PDF