• Title/Summary/Keyword: Tube Size

Search Result 809, Processing Time 0.025 seconds

A performance improvement of neural network for predicting defect size of steam generator tube using early stopping (조기학습정지를 이용한 원전 SG세관 결함크기 예측 신경회로망의 성능 향상)

  • Jo, Nam-Hoon
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.11
    • /
    • pp.2095-2101
    • /
    • 2008
  • In this paper, we consider a performance improvement of neural network for predicting defect size of steam generator tube using early stopping. Usually, neural network is trained until MSE becomes less than a prescribed error goal. The smaller the error goal, the greater the prediction performance for the trained data. However, as the error goal is decreased, an over fitting is likely to start during supervised training of a neural network, which usually deteriorates the generalization performance. We propose that, for the prediction of an axisymmetric defect size, early stopping can be used to avoid the over-fitting. Through various experiments on the axisymmetric defect samples, we found that the difference bet ween the prediction error of neural network based on early stopping and that of ideal neural network is reasonably small. This indicates that the error goal used for neural network training for the prediction of defect size can be efficiently selected by early stopping.

Degree of hydration-based thermal stress analysis of large-size CFST incorporating creep

  • Xie, Jinbao;Sun, Jianyuan;Bai, Zhizhou
    • Steel and Composite Structures
    • /
    • v.45 no.2
    • /
    • pp.263-279
    • /
    • 2022
  • With the span and arch rib size of concrete-filled steel tube (CFST) arch bridges increase, the hydration heat of pumped mass concrete inside large-size steel tube causes a significant temperature variation, leading to a risk of thermal stress-induced cracking during construction. In order to tackle this phenomenon, a hydration heat conduction model based on hydration degree was established through a nonlinear temperature analysis incorporating an exothermic hydration process to obtain the temperature field of large-size CFST. Subsequently, based on the evolution of elastic modulus based on hydration degree and early-age creep rectification, the finite element model (FEM) model and analytical study were respectively adopted to investigate the variation of the thermal stress of CFST during hydration heat release, and reasonable agreement between the results of two methods is found. Finally, a comparative study of the thermal stress with and without considering early-age creep was conducted.

The design of heat exchanger of small size steam boiler using the concentric annuli tube with pin fin (동심원관-pin fin 열교환기를 이용한 소형 증기보일러 대류실 설계)

  • Kim, Sungil;Choi, Sangmin
    • 한국연소학회:학술대회논문집
    • /
    • 2012.11a
    • /
    • pp.115-118
    • /
    • 2012
  • The configurations of the heat exchanger of the boiler can be determined from the trade-off between the heat transfer area which is related to the capital cost and the pressure drop which is related to operating cost. In this study, 3.5 ton/hr small size marine boiler having concentric annuli tubes is the design boiler. To determine the optimizing point, according to diameter, number, length of tube, heat transfer, pressure drop, operating cost and capital cost have been calculated. Also, when the fin tube is replaced by the bare tube design parameters changed have been calculated.

  • PDF

An Experimental Study on the Performance of Inverter Heat Pump with a Variation of Frequency and Capillary Size

  • Choi, Jong-Min;Kim, Yong-Chan;Kim, Jong-Yup
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.6
    • /
    • pp.27-35
    • /
    • 1998
  • An experimental study was performed to investigate the optimum cycle of an inverter heat pump as a function of frequency. The performance of the inverter heat pump with the rated cooling capacity of 4,141 W(3,550kcal/h) was measured with a variation of frequency, indoor and outdoor temperature, and length of capillary tube in the psychrometric test room. As a base case, the inverter heat pump with the standard capillary length of l,000mm(optimum size for the frequency of 60Hz) and ASHRAE Test condition "A" was tested by varying frequency from 30Hz to 80Hz. Then, the optimum cycles were investigated by varying the length of capillary tube at each frequency level of 30, 60 and 80Hz. Based on the experimental data, the change of system characteristics between the optimum and the base case were analyzed for each selected frequency level. Generally, for low frequency level(30Hz), the longer length of the capillary tube compared with the standard size showed the higher energy efficiency ratio(EER), while for high frequency level(80Hz) the shorter length of the capillary tube showed the higher EER.

  • PDF

An experimental study on the performance of inverter heat pump with a variation of frequency and capillary size (인버터 열펌프의 주파수 및 모세관 길이 변화에 따른 시스템 성능특성의 실험적 연구)

  • Choi, J.M.;Kim, Y.C.;Kim, J.Y.;Bae, Y.D.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.9 no.1
    • /
    • pp.64-72
    • /
    • 1997
  • An experiment study was performed to investigate the optimum cycle of an inverter heat pump as a function of frequency. The performance of the inverter heat pump with the rated cooling capacity of 4141W(3550kcal/h) was measured with a variation of frequency, indoor and outdoor temperature, and length of capillary tube in the psychrometric test room. As a base case, the inverter heat pump with the standard capillary length of 1000mm which was optimum size for the frequency of 60Hz and ARHRAE Test condition A was tested by varying frequency from 30Hz to 80Hz. Then, the optimum cycle was invesigated by varying the length of capillary tube at each frequency levels of 30, 60 and 80Hz. Based on the experimental data, the change of system characteristics between the optimum and the base case were analyzed for each selected frequency levels. Generally, for low frequency level(30Hz), the longer length of the capillary tube compared with the standard size showed the higher EER, while for high frequency level(80Hz) the shorter length of the capillary tube showed the higher EER.

  • PDF

Experimental and Numerical Study of Aerosol Coagulation by Gravitation (에어로졸 입자의 중력응집에 관한 실험 및 수치적 연구)

  • 권순박;이규원
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.16 no.1
    • /
    • pp.1-10
    • /
    • 2000
  • The behavior of aerosos due to gravitational coagulation was studied experimentally and numerically. In experimental study, the geometric mean particel size increased as time elapsed in a vertical tube column, while the size decreased when the tube was set horizontally. The particle size distribution was observed to maintain the lognormal form during the coagulation process. Separately, numerical calculations were performed for studying the aerosol behavior under gravitational and Brownian coagulation using the moment method. By comparing the expeimented results with the numerical predictions, the governing mechanism of the aerosol behavior proved to be gravitational coagulation.

  • PDF

The Effect of the Vibration, Air Blast and Bould Size of Blasting by means of Air Tube (에어 튜브(Air Tube)에 의한 발파의 진동, 폭음 및 전석 제어 영향 연구)

  • 강대우
    • Explosives and Blasting
    • /
    • v.18 no.3
    • /
    • pp.59-66
    • /
    • 2000
  • "Air Tube" 발파공법에 대한 연구는 기존의 일반 발파 방법의 단점을 크게 보완하여, 이 에 따른 진동, 폭음(소음), 전석 발생 등 이러한 문제점들을 해결하기 위해 고안된 것으로 기존 Air Decking 기술을 응용한 것이다. 본 연구는 폭약의 하부, 폭약과 폭약사이, 폭약의 상부와 전색 사이에 일정 길이의 "Air Tube"를 장착시켜 폭약의 투사면적을 증가시키고, 진동의 감쇠와 전석이 감소되어 특히 도심지에서 발생하는 민원의 대상이 될 수 있는 진동 및 폭음도 크게 줄일 수 있는 효과적인 발파 기술이다.일 수 있는 효과적인 발파 기술이다.

  • PDF

Numerical Analysis of Responses of a Elasto-plastic Tube under Kerosene-air Mixture Detonation (케로신-공기 혼합물의 비정상연소 모델과 탄소성 관의 동적 거동 수치해석)

  • Lee, Younghun;Gwak, Min-cheol;Yoh, Jai-ick
    • 한국연소학회:학술대회논문집
    • /
    • 2015.12a
    • /
    • pp.169-172
    • /
    • 2015
  • This paper presents a numerical investigation on kerosene-air mixture detonation and behaviors of thermal elasto-plstic thin metal tube under detonation loading based on multi-material analysis. The detonation loading is modeled by the kerosene-air mixture detonation which is compared with CJ condition and experimental cell size. And the thermal softening effect on elasto-plstic model of metal tube is indicated by different dynamic response of detonation loaded tube in various temperature and tube thickness.

  • PDF

Experimental investigation of friction in guide zone of tube hydroforming with material and lubricant (튜브 액압성형 공정의 가이드영역에서 소재 및 윤활에 따른 마찰 특성의 실험적 연구)

  • Yi, H.K.;Yim, H.S.;Lee, G.Y.;Lee, S.M.;Chung, C.S.;Moon, Y.H.
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2008.10a
    • /
    • pp.83-86
    • /
    • 2008
  • In this study, friction test was proposed to obtain coefficient of friction between tube and die in guide zone of tube hydroforming and friction coefficients were evaluated at different materials, viscosity of lubricants and internal pressures. For this study, STKM11A and SUS tubes were prepared. The tube was expanded by an internal pressure against the tool wall. By pushing the tube through the tool, a friction force at the contact surface between the tube and the tool occurs From the recorded axial feeding forces, the friction coefficients between tube and die at the guide zone in tubular hydroforming can be estimated. The effects of the various internal pressures, viscosity of lubricants, tube materials, tube size and die coating on the friction forces and friction coefficients are discussed.

  • PDF

The Fundamental Study on the Properties of Foam for Foamed Concrete (기포 콘크리트용 기포의 특성에 관한 기초 연구)

  • Kawg, Eun-Gu;Kang, Gie-Hyun;Kang, Cheol;Kwon, Ki-Joo;Kim, Jin-Man
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2004.05a
    • /
    • pp.680-683
    • /
    • 2004
  • This study is to obtain basic data concerned with properties of foam for foamed concrete and foaming method. Main factors of this study are types of foaming agents, temperature of solution with foaming agents, and types of foam generator. Testing items are size distribution of foam, foaming ratio to solution, and stability of foam. The results of this study were shown as follow. It is optimum condition of foam generator that length/diameter of foaming tube is 2.0, bead size within foaming tube is $4\~6mm$, and nozzle size of foaming tube is 10mm. AES and AOS are good results to produce high quality foam, and stability of foam is good in foaming temperature of $20^{\circ}C$.

  • PDF