• Title/Summary/Keyword: Tube Potential

Search Result 371, Processing Time 0.022 seconds

The Study of Corrosion of Heat Exchanger Tube for Absorption Refrigeration Machine (흡수식냉동기용 열교환기 세관의 부식에 관한 연구)

  • 임우조;정기철;윤병두
    • Proceedings of the Korean Society of Marine Engineers Conference
    • /
    • 2002.05a
    • /
    • pp.147-152
    • /
    • 2002
  • This paper was studied on corrosion of heat exchanger tube for absorption refrigeration machine. In the 62 % lithium bromide solution at $60^{\circ}C$, polarization test of Cu, Al-brass, 10 % cupro nickel(90-10 % Cu-Ni) and 30 % cupronickel(70-30 % Cu-Ni) tube was carried out. And polarization behavior, polarization resistance characteristics, open circuit potential, anodic polarization of heat exchanger tube for absorption refrigeration machine were considered. The main results are as following: The open circuit potential of Al-brass tube becomes less noble than that of Cu tube, corrosion current density of that becomes lower than Cu tube. The open circuit potential of cupronickel tube is more noble than that of Cu tube, corrosion current density of that is controlled than Cu tube. The passivation critical current of 30 % Cu-Ni tube is lower than that of 10 % Cu-Ni tube, potential of passive region of that is more wide than 10 % Cu-Ni tube.

  • PDF

The Study on Corrosion Characteristics of Heat Exchanger Tube for Gas Absorption Refrigeration & Hot Water System (가스흡수식 냉온수기 열교환기용 세관의 부식특성에 관한 연구)

  • Jeong Ki Cheol
    • Journal of the Korean Institute of Gas
    • /
    • v.6 no.1 s.17
    • /
    • pp.92-97
    • /
    • 2002
  • This paper was studied on corrosion characteristics of gas absorption refrigeration & hot water system using $LiBr-H_2O$ working fluids. In the $62\%$ lithium bromide solution at $60^{\circ}C$, polarization test of Cu, $10\%$ cupronickel($90-10\%$ Cu-Ni) and $30\%$ cupronickel($70-30\%$ Cu-Ni) tube was carried out. And polarization behavior, polarization resistance characteristics, open circuit potential, anodic polarization of heat exchanger tube for gas absorption refrigeration & hot water system were considered. The main results are as following: 1) Polarization resistance of heat exchange tubes appears high in order of $30\%$ cupronickel tube > $10\%$ cupronickel tube > Cu tube. B) Open circuit potential of cupronickel tube is more noble than that of Cu tube, and corrosion current density of cupronickel is controlled than Cu tube. 3) Potential of passive region of $30\%$ cupronickel tube is more wide than that of $10\%$ cupronickel tube, and the passivation critical current of $30\%$ cupronickel tube is lower than that of $10\%$ cupronickel tube.

  • PDF

Effect of Zinc Addition in Filler Metal on Sacrificial Anode Cathodic Protection of Fin-Tube Aluminum Heat Exchanger

  • Yoon-Sik So;Eun-Ha Park;Jung-Gu Kim
    • Journal of Electrochemical Science and Technology
    • /
    • v.14 no.4
    • /
    • pp.349-360
    • /
    • 2023
  • This study investigated the tri-metallic galvanic coupling of different metals in the tubes, fillers, and fins of a heat exchanger. The goal was to prevent corrosion of the tubes using the fin as a sacrificial anode while ensuring that the filler metal has a more noble potential than the fin, to avoid detachment. The metals were arranged in descending order of corrosion potential, with the noblest potential assigned to the tube, followed by the filler metal and the fin. To address a reduction in protection current of the fin, the filler metal was modified by adding Zn to decrease its corrosion potential. However, increasing the Zn content of filler metal also increases its corrosion current. The study examined three different filler metals, considering their corrosion potential, and kinetics. The results suggest that a filler metal with 1.5 wt.% Zn addition is optimal for providing cathodic protection to the tube while reducing the reaction rate of the sacrificial anode.

Experiment for Clinical Application with Photodiode (Photodiode를 사용한 측정기의 임상응용을 위한 실험)

  • Kim, You-Hyun;Kwon, Soo-Il;Huh, Joon
    • Journal of radiological science and technology
    • /
    • v.19 no.2
    • /
    • pp.71-77
    • /
    • 1996
  • Studies were conducted to determine the clinical application of photodiode. We compared photodiode with ion-chamber as to change of tube potential, tube current, mAs and measured decreasing rate of penetration dose. When tube potential was changed from 60 kVp to 120 kVp, output of photodiode and ion-chamber were changed from 0.4 to 1.625, and 1.018 to 4.268, respectively. This was a good agreement to theory that $I=Kv^2it$(I is intensity, K is constant, v is tube potential, i is tube current, t is time). Characteristics for change of tube current and mAs were also a good agreement to theory. And comparison in decreasing rate of penetration dose was similar except above 6 cm in depth. Our results indicated that photodiode was a good instrument for relative measurement of radiation exposure, but we can not use the photodiode for absolute radiation dose.

  • PDF

Enhancement of Hydroformability Through the Reduction of the Local Strain Concentration (국부적 변형 집중 저감을 통한 액압 성형성 개선연구)

  • Shin, S.G.R.;Joo, B.D.;Moon, Y.H.
    • Transactions of Materials Processing
    • /
    • v.23 no.5
    • /
    • pp.317-322
    • /
    • 2014
  • Bursting during tube hydroforming is preceded by localized necking. The retardation of the initiation of necking is a means to enhance hydroformability. Since high strain gradients occur at the necking sites, a decrease in local strain gradients is an effective way to retard the initiation of necking. In the current study, the expansion at potential necking sites was intentionally restricted in order to reduce the strain gradient at potential necking sites. From the strain distribution obtained from FEM, it is possible to determine strain concentrated zones, which are the potential necking sites. Prior to the hydroforming of a trailing arm, an incompressible material(such as lead) is attached to the tube where the strain-concentrated zone would contact the die. Due to the incompressibility of lead, the tube expansion is locally restricted, and the resultant strain extends to adjacent regions of the tube during hydroforming. After the first stage of hydroforming, the lead is removed from the tube, and the hydroforming continues to the final targeted shape without any local restriction. This method was successfully used to fabricate a complex shaped automotive trailing arm that had previously failed during traditional hydroforming fabrication.

A Method for Simultaneous Measurement of Air Kerma, Half Value Layer and Tube Potential in Quality Control Procedure of Diagnostic x ray units

  • Katoh, Tsuguhisa;Saitoh, Hidetoshi;Ohtani, Hiroki;Negishi, Tooru;Myojoyama, Atsushi;Ohno, Yuusuke;Sasaki, Takehito
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2002.09a
    • /
    • pp.294-297
    • /
    • 2002
  • For the quality control procedure of diagnostic x ray units, a method for simultaneous measurement of air kerma, half value layer and tube potential was developed utilizing a computed radiography system for intraoral radiography and film badge case. The response of average pixel values under the windows were calibrated by x rays generated at tube potentials from 40 to 140 kV with filtration from 1.5 to 3.7 mmAl. The calibration curves for half value layer and tube potential were derived as functions of attenuation factors by the 1.4 mmAl filter and the 0.2 mmCu filter. The energy dependency of the open window response was corrected by the calibration factor as a function of the attenuation factor by the 1.4 mmAl filter. The uncertainty of the estimated half value layer, tube potential and air kerma were 0.2 mmAl, 3.6 % and 5 %, respectively. It was thus suggested that this system could be applied to quality control program to detect the variation of working condition of x ray units in clinical use.

  • PDF

Condensation Heat Transfer Characteristics of HCFC - 123 inside Horizontal Smooth Tube (HCFC-123의 수평 평활관내 응축 전열 특성에 관한 연구)

  • 권옥배;오후규;오종택;김성규
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.17 no.3
    • /
    • pp.24-32
    • /
    • 1993
  • Experimental data on the heat transfer characteristics of HCFC-123 and CFC-11 during condensation in horizontal smooth tube are presented. The experimental apparatus consisted of a closed working fluid loop, coolant loop, and measuring system. The major components of the working fluid loop made of a refrigerant pump, boiler, superheater, refrigerant flow meter, receiver and test section. The tube-in-tube type test section was made of smooth tube which were constructed form 9.52 mm outer diameter of smooth copper tube with 50 mm outside diameter of PVC tube duct. The ranges of parameter, such as refrigerant mass velocity, coolant flow rate, and quality were 90-325kg/($m^2$.s), 60-360kg/h, 5-95% respectively. Data were obtained under steady state condition for annular flow. As a result of these, the condensation heat transfer coefficients for HCFC-123 were slightly lower than those of CFC-11 from 8% to 15% inside horizontal smooth tube. Furthermore, a new generalized correlation for the heat transfer coefficients of HCFC-123 and CFC-11 during condensation inside horizontal smooth tube is proposed.

  • PDF

A Brief Review on the Design Factors of Steam Generator U-Tube Assembly for CANDU Type Nuclear Power Plant

  • Park, Nam-Il;Park, June-Soo
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1996.05d
    • /
    • pp.321-326
    • /
    • 1996
  • During the plant operation, steam generator U-tube assembly will potentially be subject to adverse environmental conditions which can cause damages to them. This report addresses the major design factors of CANDU type steam generator which are intended to minimize the potential tube damages. Such factors include U-tube material, high circulation ratio, tube-to-tubesheet joint, tube support design. Also a few suggestions are presented for the design and performance improvement of CANDU type steam generators.

  • PDF

A Study on the Crevice Corrosion for Ferritic Stainless Steel by Micro Capillary Tube Method

  • Na Eun-Young;Ko Jae-Yong;Baik Shin-Young
    • Journal of the Korean Electrochemical Society
    • /
    • v.7 no.4
    • /
    • pp.179-182
    • /
    • 2004
  • The aim of this study is to investigate the initiation and propagation of crevice corrosion for ferritic stainless steel in artificial crevice based on micro capillary tube method. The 430 stainless steel in artificial crevice is potentiostatically polarized in different sodium chloride solutions. Potentiodynamic and potentiostatic polarization data were measured in situ. The potentials in the crevice were measured by depth profile using the 0.04 mm diameter micro capillary tube inserted in the crevice. The potentials in the crevice ranged from -220 mV to -360 mV vs SCE from opening to bottom of crevice, which are lower than the external surface potential, -200 mV vs SCE. Such a potential drop induced the change of the metal surface state from passive to active. The surface of metal is located in passive state in -200 mV but the inner surface keeps active state below -220 mV, Thus these results show that the It drop mechanism in the crevice was more objective for evaluation and the method was easier to reproduce. Therefore the potential drop is one of the reasons for crevice corrosion by measuring the potentials in narrow crevice with a new micro measuring system.

A Quartz Tube Based Ag/Ag+ Reference Electrode with a Tungsten Tip Junction for an Electrochemical Study in Molten Salts

  • Park, Y.J.;Jung, Y.J.;Min, S.K.;Cho, Y.H.;Im, H.J.;Yeon, J.W.;Song, K.
    • Bulletin of the Korean Chemical Society
    • /
    • v.30 no.1
    • /
    • pp.133-136
    • /
    • 2009
  • A newly designed Ag/$Ag^+$ reference electrode in a quartz tube with a tungsten tip junction (W-tip-Quartz- REF) was fabricated and its electrochemical performance was compared with a conventional Pyrex tube-based Ag/$Ag^+$ reference electrode (Py-REF). The results of the electrochemical potential measurements with the W-tip-Quartz- REF and the Py-REF in the LiCl-KCl eutectic melts for a wide temperature range proved that the oxide layer on the surface of the tungsten metal tip provided a high ionic conduction. Stability of our newly designed W-tip- Quartz-REF was tested by measuring a junction potential for 12 hours at 700${^{\circ}C}$. The results of the cyclic voltammetric measurement indicated that the Ag/$Ag^+$ reference electrode in the quartz tube with a tungsten tip junction can provide a good performance for a wide temperature range.