• Title/Summary/Keyword: Tube Metal Temperature

Search Result 120, Processing Time 0.021 seconds

Analysis of the Effect on the Performance of Ceramic Metal Halide Lamp by the Loss of Elements that have been Filled in Arc Tube (아크튜브내의 구성물 손실이 세라믹 메탈 핼라이드 램프의 특성에 미치는 영향분석)

  • Jang, Hyeok-Jin;Yang, Jong-Kyung;Park, Dae-Hee
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.12
    • /
    • pp.2446-2452
    • /
    • 2009
  • A Ceramic Metal-halide lamp is achieved by adding multiple metals to a basic mercury discharge. Because the vapor pressure of most metals is very much lower than mercury itself, metal-halide salts of the desired metals, having higher vapor pressures, are used to introduce the material into the basic discharge. The metal compounds are usually polyatomic iodides, which vaporize and subsequently dissociate as they diffuse into the bulk plasma. Metals with multiple visible transitions are necessary to achieve high photometric efficiency and good color. Compounds of Sc, Dy, Ho, Tm, Ce, Pr, Yb and Nd are commonly used. The maximum visible efficacy of a Ceramic Metal Halide lamp, under the constant of a white light source, is predicted to be about 450lm/W. This is controlled principally by the chemical fill chosen for a particular lamp. Current these lamps achieve 130lm/W and these life time are the maximum 16,000[hr]. So factors of performance lower are necessary to improve lamp performance. In this paper, we analyzed factors of performance lower by accelerated deterioration test. The lamp was operated with short duration turn-on/turn-off procedure to enhance the effect due to electrode sputtering during lamp ignition. The tested lamp that was operated with a longer turn-on/off(20/20 minutes) showed blackening, changed distance between electrodes and lowered color rendering & color temperature by losses of Dy at 421.18nm, I at 511nm, T1 at 535nm and Na at 588nm compared with the new lamp.

Metal Vapor Laser Research II. (금속증기레이저 연구 II)

  • 이재경;정환재;임기건;이형종;정창섭;김진승
    • Korean Journal of Optics and Photonics
    • /
    • v.3 no.3
    • /
    • pp.178-182
    • /
    • 1992
  • An air-cooled discharge-heated copper-vapor laser system with its inter-electrode distance of 45 cm has been developed by utilizing an alumina ceramic plasma tube of 1.6 cm in diameter and 50 cm in lengih. For operating the laser, a dc high voltage power supply with output rating of 6 kV and 500 mA, a resonant charging circuitry consisting partly of an 1.8 H inductor assembly and a 5 nF storage capacitor, and a thyratron driver operating up to 7 kHz have also been developed. The present laser system starts lasing at the tube temperature of about $1350^{\circ}C$ and an maximum average output power of 0.7 W has been obtained at 12 kV, 4.5 kHz. 50 mbar of Ne buffer gas pressure, and at the tube temperature of $1460^{\circ}C$.

  • PDF

Analysis of Welding Distortion for Laser Welded Sheet Metal Structures of Aluminum Alloy (레이저용접에 의한 알루미늄 박판구조물의 용접변형 해석)

  • Kwon, Ki-Bo;Kim, Jae-Woong;Kim, Cheol-Hee
    • Journal of Welding and Joining
    • /
    • v.27 no.3
    • /
    • pp.44-51
    • /
    • 2009
  • In this study, welding distortion analysis is performed for various design of tube shape structures which are assembled with aluminum sheet metal. Aluminum 5052 plates of 1mm thickness are used to analyze. An efficient keyhole model, as a welding heat source, is used for the prediction of full penetration weld size and shape which is required for the thermal analysis. The thermal and mechanical material properties are considered as temperature dependent functions, due to the high temperature variations during the welding. The numerical model is calculated by using a commercial software and evaluated with the experiments. The calculation results could make a comparative study in the view of distortion for the various size and shape of structure.

Numerical analysis of the venturi flowmeter in the liquid lead-bismuth eutectic circuit after long-term operation

  • Zhichao Zhang;Rafael Macian-Juan;Xiang Wang
    • Nuclear Engineering and Technology
    • /
    • v.56 no.3
    • /
    • pp.1081-1090
    • /
    • 2024
  • The liquid Lead-bismuth eutectic is used as the coolant for Gen-IV reactor concepts. However, due to its strong corrosive and high operating temperature, it is difficult to accurately measure the flow rate in long-term operating conditions. Venturi flowmeter is a simple structured flowmeter, which plays a very important role in the flow measurement of high-temperature liquid metals, especially since the existing flowmeters are difficult to be competent. It has the advantages of easy maintenance and stable operation. Therefore, it is necessary to study the operating conditions of the venturi flowmeter under high-temperature conditions. This work performs a series of simulations of the fluid-solid interaction between the flow liquid metal and venturi flowmeter with COMSOL software, including the dimensional sensitivity analysis of the venturi flowmeter to explore the most suitable structure and parameters for liquid heavy metal, the sensitivity analysis of the geometric parameters of the venturi tube on the varying conditions. It shows that when the contraction angle of the venturi flowmeter is 33°, the diffusion angle is 13°, the diameter of the throat is 8 mm, and the temperature of the lead-bismuth eutectic is 733.15 K, it is most suitable for the measurement in the lead-bismuth circuit.

Development of Self-Actuated Shutdown System Using Curie Point Electromagnet

  • Kim, Tae-Ryong;Park, Jin-Ho
    • Nuclear Engineering and Technology
    • /
    • v.31 no.6
    • /
    • pp.1-7
    • /
    • 1999
  • An innovative concept for a passive reactor shutdown system, so called self-actuated shutdown system(SASS), is inevitably required for the inherent safety in liquid metal reactor, which is designed with the totally different concept from the usual reactor shutdown system in LWR. SASS using Curie point electromagnet(CPEM) was selected as the passive reactor shutdown system for KALIMER (Korea Advanced Liquid MEtal Reactor). A mock-up of the SASS was designed, fabricated and tested. From the test it was confirmed that the mockup was self-actuated at the Curie point of the temperature sensing material used in the mockup. An articulated control rod was also fabricated and assembled with the CPEM to confirm that the control rod can be inserted into core even when the control rod guide tube is deformed due to earthquake. The operability of SASS in the actual sodium environment should be confirmed in the future. All the design and test data will be applied to the KALIMER design.

  • PDF

Design of Large Capacity Clean Air Heater (대용량 청정 공기 가열 장치 설계)

  • Kim, Jeong-Woo;Jung, Kwang-Soo;Jeon, Min-Joon;Lee, Kyu-Joon
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2010.11a
    • /
    • pp.115-118
    • /
    • 2010
  • 2 Types of heater (Vitiated Type, Clean Air Type) in order to increase the temperature for a test are used for industry. In this report, large capacity clean air type heater was designed. Heater capacity and LNG consumption rate can be calculated by the air mass flow and heater inlet/outlet temperature. The heater is composed by Burner, Furnace, Heat Exchanger, and Stack. The hot air from the burner and cold air from the tube inlet exchange their heat indirectly in the heat exchanger, so the desired temperature can be achieved at the exit of the tube.

  • PDF

An Implementation of an Integrated Degasing System for Aluminum Molten Metal in Continuous Casting (알루미늄 연속주조 용탕의 탈 가스 일체화 장치 개발)

  • Lee, Yong-Joong
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.17 no.1
    • /
    • pp.1-6
    • /
    • 2008
  • There are some methods that have been used to manage a degasing process in recent years, such as an injection method that uses aluminum molten metal powder and chemicals supplier and input method that supplies argon and nitrogen, or chlorine gas by using a gas blow-tube. However, these methods show some problems, and it shows that it is a difficult process to handle, pollution due to producing a lot of toxic gases like chlorine and fluoride gas, irregular effects, and lowering work efficiency due to the excessive processing time. The problems that are the most fatal are the producing a lot of sludge due to the reaction of aluminum molten metal with chemicals, loss of metals, and decreasing the life of refractory materials. In order to solve these problems, this paper develops a technology that is related to aluminum continuous casting molten metal and monolithic degasing apparatus. A degasing apparatus developed in this study improved the existing methods and prevented environmental pollution with smokeless, odorless, and harmlessness by using a new method that applies argon and nitrogen gas in which the methods used in the West and Japan are eliminated. The method developed in this study decreases the molten metal processing and settling time compared to the existing methods and improves the workers' health, safety, and environment because there is no pollution in processes.

Design and Simulation of Heating Rubber Roller for Laminating Process

  • Hur, Shin;Woo, Chang Su
    • Elastomers and Composites
    • /
    • v.51 no.4
    • /
    • pp.280-285
    • /
    • 2016
  • The purpose of this study is to get optimum design and operation conditions of the heating rubber roller for laminating process. The cause of performance degradation of heating rubber roller is delamination of rubber on metal tube, rubber aging due to high temperature. We measured the material properties of thermal expansion, thermal conductivity, specific heat and density and analyzed thermal distributions of rubber layer using finite element method. As a result of heat/flow analysis, the density distribution of heating coil must shorten the stabilization time by reducing the temperature deviation on the length direction at the temperature rising section after increasing the density of the area contacting with the laminate film at the center part which is an opposite of the current composition while enabling to maintain the temperature of heater to be consistent while maintaining the temperature deviation to be low when heat loss is created. Finally, we determined optimum heating method of heating rubber roller.

Development of Direct Extrusion Process on Al 1050 Condenser Tube by using Porthole Die (포트홀 다이를 이용한 Al1050 컨덴서 튜브의 직접압출공정 기술 개발)

  • 이정민;김병민;강충길;조형호
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.21 no.7
    • /
    • pp.53-61
    • /
    • 2004
  • Condenser tube which is used for a cooling system of automobiles is mainly manufactured by conform extrusion. However, direct extrusion using porthole die in comparison with conform extrusion has many advantages such as improvement of productivity, reduction of production cost etc. In general, the porthole die extrusion process is useful for manufacturing long tubes with hollow sections and consists of three stages(dividing, welding and forming stages). Especially, Porthole die for producing condenser tube is very complex. Thus, in order to obtain the detailed mechanics, to assist in the design of proper die shapes and sizes, and to improve the quality of products, porthole die extrusion should be analyzed in as non-steady state as possible. This paper describes FE analysis of non-steady state porthole die extrusion for producing condenser tube with multi-hole through 3D simulation in the non-steady state during the entire process to evaluate detailed metal flow, temperature distribution, welding pressure and extrusion load. Also to validate FE simulation of porthole die extrusion, a comparison of simulation and experiment results was presented in this paper.

Cause Investigation and Verification of Fire Accidents for Road and Street Lighting (가로등 화재사고의 원인규명과 검증)

  • Shong, Kil-Mok;Han, Woon-Ki;Kim, Jong-Min;Kim, Young-Seok;Kim, Myoung-Soo;Kim, Hyeok-Soo
    • Journal of Korean Institute of Fire Investigation
    • /
    • v.11 no.1
    • /
    • pp.31-36
    • /
    • 2008
  • This paper carried out a variety of analysis for a finding out the causes of fire on the street lamp. The glass bulb of 250W metal-halide(MH) lamps attached with the impurities rose the temperature by at $410.4^{\circ}$ in normal condition. Therefore, a lamp apparatus is needed the improvement for ventilation and the protection against dust. The heat of MH lamps is diffused through out the luminous tube, a glass bulb, and apparatus by degrees. The accident cause of the lamp is presumed that the accumulated heat by deposits of the inner part. It will be recommended the improvement of the structure that aren't the external impurity and accumulated heat in the MH lamps set.

  • PDF