• Title/Summary/Keyword: Tube Line

Search Result 366, Processing Time 0.029 seconds

NUMERICAL ANALYSIS FOR LONGITUDINAL PITCH EFFECT ON TUBE BANK HEAT TRANSFER (관군 배열에서의 종간 간격이 열전달에 미치는 영향에 대한 수치 해석적 연구)

  • Lee, D.;Ahn, J.;Shin, S.
    • Journal of computational fluids engineering
    • /
    • v.17 no.3
    • /
    • pp.39-44
    • /
    • 2012
  • In this study, a longitudinal pitch effect on in-line tube bank heat transfer has been analyzed numerically. To verify the accuracy of the solver model and boundary conditions, global Nusselt number(Nu) and pressure drop across the 2 row tube bank are compared with the existing experimental correlations under 500 ~ 2,000 Reynolds number(Re) range. By changing transverse pitch($S_T$) or longitudinal pitch($S_L$) separately in tube bank, we're trying to identify the each effect on heat transfer. We found that the effect of transverse pitch can be accounted for Reynolds number evaluated with maximum velocity($V_{max}$) at the smallest flow area similar to most existing correlations. Variation of the longitudinal pitch($S_L$) has a greater impact on the heat transfer compared to the transverse pitch($S_T$). Overall Nusselt number increases with larger longitudinal pitch($S_L$), however individual Nusselt number of the tube row has significant difference after the first row.

Efficient Design of Gun-Tube Considering Inner Pressure of Bore (포강 내 압력을 고려한 효율적 포신 설계)

  • Eubin Kim;Gyubin Kim;Eun Gyo Park;Seok-Hwan Oh;Tae-Seong Roh;Jin Yeon Cho
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.26 no.5
    • /
    • pp.371-383
    • /
    • 2023
  • Artillery gun tube experiences very high pressure according to the blast of propellant charge. Therfore, it is essential to guarantee the structural safety of the gun tube. On the other hand, weight reduction of gun tube is also a crucial design factor since the agility of artillery vehicle directly leads to its survivability. In this line of thought, this work proposed an efficient design procedure which utilizes the convex combination of breech pressure and projectile base pressure time histories. Its efficiency is verified by comparing with other procedures. Other procedures utilize different computed max pressure rather than the convex combination design pressure. Additionally, a transient analysis is carried out considering the projectile movement and the corresponding pressure distribution through the newly developed ABAQUS user-subroutine. The analysis confirms the structural safety of the lightweight gun tube designed by the proposed method.

Heat Transfer Study to Replace a Tube Bundle of Moisture Separator Reheater at Nuclear Power Plant (원전 습분분리재열기 튜브 번들 교체를 위한 열전달 고찰)

  • Choi, You-Sung;Choi, Kwang-Hee;Lee, Sang-Guk
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • v.6 no.1
    • /
    • pp.65-71
    • /
    • 2010
  • The plugging rate of reheater tubes of Wolsung unit 1 nuclear power plant has been increased by corrosion and erosion since 1990. As the dimensions of the new first stage reheater bundle tubes which were supplied by Hanjung company to replace were different from old one, numerical calculations are carried out for flow and heat transfer in the reheater bundle tubes of the N.P.P. Numerical calculations consists of thermal performance, drain line pressure drop, flow change by pressure drop of line, stress analysis of finned tubes and analysis of flow induced vibration. Computational analysis using heat transfer research institute program is adopted to verify the results of the numerical calculations. It contains the evalution of performance in the system with view to location of the new reheater bundle and it shows the differences between the numerical calculation results and heat transfer research institute program output.

  • PDF

The Identification of Vibration Source and Its Transmission Paths In Compressor Using PCF Method (PCF법을 이용한 왕복동압축기의 진동원 및 진동전달경로 규명)

  • Lee, Dae-Sung;Hwang, Won-Gul;Lee, You-Yub;Im, Hyung-Eun
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2002.11a
    • /
    • pp.386.1-386
    • /
    • 2002
  • It is necessary to determine the vibration source and its transmission paths in order to develop a low-noise compressor Through the use of multiple-input/single-output(MISO) model, the transmission paths of vibration within a reciprocating compressor have been investigated. In order to identify the transmission path, we measure the accelerations of the block and transverse vibrations of the line discharge tube. (omitted)

  • PDF

A Study on the fin efficiency of continuous fin - tube heat exchanger, -In the case of sensible heat transfer- (섹터법을 이용한 연속휜-튜브형 열교환기의 휜효율에 관한 연구, -현열 열전달의 경우-)

  • Jung, Hyeong-Ho
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.20 no.5
    • /
    • pp.76-81
    • /
    • 1996
  • In this paper, a calculation method for fin efficiency of continuous fin is introduced. The continuous fin of in-line and staggered arrangement was divided into many sectors and fin efficiencies of each sectors were calculated by assuming that each sectors be the circular fins. To get the converged fin efficiency which is averaged by the each areas, the number of sectors was increased. The results were compared with equivalnet method by varying the aspect ratios in both cases of in-line and staggered tube arrangement and showed some differences of fin efficiencies.

  • PDF

A study on the Development of Purge Burner for City Gas (도시가스용 퍼지 버너 개발에 관한 연구(II))

  • Lee, Hyun-Chan;You, Hyun-Seok;Lee, Joong-Seong
    • Proceedings of the KSME Conference
    • /
    • 2000.04b
    • /
    • pp.175-179
    • /
    • 2000
  • A combustion project was completed regarding the development of a high-flow-rate purge burner in cooperation with three city gas companies(Pusan, Taegu, Samchulli). The project, started in May 1991, aimed at purging the line-packed-gas safely and quickly before getting into gas pipe working or relocation. According to the results, the purging noise is less than 80dB due to silencer screen. multi-nozzle and outlet inserted tube employed. In addition, the developed burner shows an increased work efficiency of 40-50% more as compared to the performance of conventional purge equipments. The project result is regarded as the first high-flow-rate purge burner developed within Korea. contributing to shortening purge hours, safe field work and easiness of purge site selection.

  • PDF

X-ray Micro-Imaging Technique and Its Application to Micro-Bubbles in an Opaque Tube (X-ray Micro-Imaging 기법 소개 및 불투명 튜브 내부의 마이크로 버블 가시화 연구)

  • Lee Sang-Joon;Kim Seok;Paik Bu-Geun
    • 한국가시화정보학회:학술대회논문집
    • /
    • 2002.11a
    • /
    • pp.31-34
    • /
    • 2002
  • Imaging techniques using x-ray beam at high energies (>6KeV) such as contact radiography, projection microscopy, and tomography have been used to nondestructively discern internal structure of objects in material science, biology, and medicine. This paper introduces the x-ray micro-imaging method using 1B2 micro-probe line of PAL (Pohang Accelerator Laboratory). Cross-sectional information on low electron density materials can be obtained by probing a sample with coherent synchrotron x-ray beam in an in-line holography setup. Living organism such as plants, insects are practically transparent to high energy x-rays and create phase shift images of x-ray wave front. X-ray micro-images of micro-bubbles of $20\~120\;{\mu}m$ diameter in an opaque tube were recorded. Clear phase contrast images were obtained at Interfaces between bubbles and surrounding liquid due to different decrements of refractive index.

  • PDF

Optimization of DC Operating Voltage for GDT-Adopted SPD (가스방전관(GDT)을 적용한 서지보호장치 회로의 DC 동작전압 최적조건 고찰)

  • Choi, Jong-Min;Jeon, Tae-Hyun
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.26 no.7
    • /
    • pp.92-98
    • /
    • 2012
  • It is made compulsory to install SPD for the purpose of protecting electric and electronic devices when an abnormal voltage such as lightning occurs to power line using power frequency of 60Hz. Recently, the high speed communication technology utilizing power line is receiving attention again as a communication technology for smart grid. The SPD influences the performances of power line communication when using SPD and power line communication system together. In order to improve the performance of power line communication, a proposed scheme for series connection of gas discharge tube to ZnO varistor was presented. This paper measured the impacts of series connection of GDT to SPD using ZnO varistor on the limit voltage of Class III SPD. This paper also presented the DC operating voltage of GDT which satisfies the limit voltage of power line communication system and SPD simultaneously.

An Experimental Study on Fluid Flow and Heat Transfer Around Four Circular Cylinders of In-line (직렬 4원주 주위의 유체유동 및 열전달에 관한 실험적 연구)

  • Choe, Soon-Youl;Kim, Min-Soo
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.32 no.5
    • /
    • pp.691-697
    • /
    • 2008
  • Heat exchangers are commonly used in practice in a wide range of application, from heat and air-conditioning system in a household, to chemical processing and power production in large plant. An Experimental study was conducted to investigated the fluid flow and heat transfer around four circular cylinders of in-line in a cross flow of air. The local and average heat transfer characteristics for tube banks are investigated in the present study. Heat transfer in a heat exchanger usually involves convection in each fluid and conduction through the wall separating the two fluid. The in-line pitch ratio was in the range $1.5{\leq}L/d{\leq}4.0$, where L is the center distance and d the cylinder diameter, and in the Reynolds number $8,000{\leq}Re{\leq}50,000$. The local and mean Nusselt numbers were estimated. Subsequently, the heat transfer characteristics of four circular cylinders are found to exhibit a strong dependency upon the separation point of their upstream cylinders.