• 제목/요약/키워드: Truss model

검색결과 432건 처리시간 0.028초

Influence of Removed Web Members in Shaping Formation for Hypar Space Truss

  • 김진우
    • 한국해양공학회지
    • /
    • 제20권2호
    • /
    • pp.16-21
    • /
    • 2006
  • This paper discusses the behavior of post-tensioned and shaped hypar space truss, with consideration of the influence of removing some web members. Hypar space truss is post-tensioned at the bottom chords of one diagonal on the ground; the essential behavior characteristic of shape formation is discussed by using a small-scale test model. Results of experiments and nonlinear finite-element analysis indicate that a planar, rectangular- arranged structure can be deformed to a predicted hyper shape, by the proposed shape formation method. Also the feasibility of the proposed method for furnishing of a hypar shaped face truss has been presented, under the condition of both non-removed and partially removed web members. It follows that a nonlinear finite element analysis method can be used in predicting the behavior of the space shape and the post-tensioning force in sharing of hypar space truss. Further, in comparison to the other cases, the results of test and analysis show that the active diagonal shaping in the non-removed web members and passive diagonal shaping of partially removed web members are in relatively good agreement.

밀도법을 이용한 스페이스 트러스 구조물의 초기 형상 설계 (Initial Shape Design of Space Truss Structure using Density Method)

  • 김호수;박영신;양명규;이민호;김재윤
    • 한국공간구조학회논문집
    • /
    • 제10권4호
    • /
    • pp.59-66
    • /
    • 2010
  • 본 연구는 스페이스 트러스 구조물의 초기 형상을 결정하기 위해 밀도법을 이용한 위상최적화 기술을 고려하고자 한다. 대부분의 초기 형상설계는 다양한 최적화 방법을 활용하지 않고 설계자의 경험이나 시행착오적인 방법을 바탕으로 수행되고 있다. 이런 이유로 합리적이고 경제적인 최적화기술이 초기 형상설계에 도입되어야 한다. 따라서 본 연구에서는 스페이스 트러스 구조물을 대상으로 설계영역을 설정하고 위상최적화를 수행하여 최적의 재료분포를 찾은 뒤 크기최적화를 이용하여 최적부재 크기를 찾고자 한다. 이와 같이 밀도법을 이용한 위상 및 크기최적화를 병행하여 수행할 경우 합리적인 스페이스 트러스 구조물의 초기 형상을 도출할 수 있다.

  • PDF

Truss Spar의 파강제력에 대한 실험적 연구 (An Experimental Study for the Wave Exciting Force of a Truss Spar)

  • 조효제;구자삼;오태원;김병우;하문근
    • 한국해양공학회:학술대회논문집
    • /
    • 한국해양공학회 2002년도 추계학술대회 논문집
    • /
    • pp.261-266
    • /
    • 2002
  • This study presents the wave forces for spar platforms. The advantage of spar platform is that it is easy to manufacture and excellency to motion characteristics. It is important to estimate exactly wave force acting spar platforms for basic design of them. We measured the wave exciting force for classic spar and truss spar model, and accomplished the numerical calculation using diffraction theory. The results show that experimental values are good agreement with theoretical values. But it is difficult to estimate accurate value considering the heave plate of truss spar due to the viscosity.

  • PDF

In-plane seismic performance of masonry wall retrofitted with prestressed steel-bar truss

  • Hwang, Seung-Hyeon;Kim, Sanghee;Yang, Keun-Hyeok
    • Earthquakes and Structures
    • /
    • 제19권6호
    • /
    • pp.459-469
    • /
    • 2020
  • An external prestressed steel-bar truss unit was developed as a new strengthening technology to enhance the seismic performance of an in-plane masonry wall structure while taking advantage of the benefits of a prestressed system. The presented method consists of six steel bars: two prestressed vertical bars to introduce a prestressing force on the masonry wall, two diagonal bars to resist shear deformation, and two horizontal bars to maintain the configuration. To evaluate the effects of this new technique, four full-scale specimens, including a control specimen, were tested under combined loadings that included constant-gravity axial loads and cyclic lateral loads. The experimental results were analyzed in terms of the shear strength, initial stiffness, dissipated energy, and strain history. The efficiency of the external prestressed steel-bar truss unit was validated. In particular, a retrofitted specimen with an axial load level of 0.024 exhibited a more stable post behavior and higher energy dissipation than a control specimen with an observed complete sliding failure. The four vertical bars of the adjacent retrofitting units created a virtual column, and their strain values did not change until they reached the peak shear strength. The shear capacity of the masonry wall structure with external prestressed steel-bar truss units could be predicted using the model suggested by Yang et al.

Damage detection in truss bridges using transmissibility and machine learning algorithm: Application to Nam O bridge

  • Nguyen, Duong Huong;Tran-Ngoc, H.;Bui-Tien, T.;De Roeck, Guido;Wahab, Magd Abdel
    • Smart Structures and Systems
    • /
    • 제26권1호
    • /
    • pp.35-47
    • /
    • 2020
  • This paper proposes the use of transmissibility functions combined with a machine learning algorithm, Artificial Neural Networks (ANNs), to assess damage in a truss bridge. A new approach method, which makes use of the input parameters calculated from the transmissibility function, is proposed. The network not only can predict the existence of damage, but also can classify the damage types and identity the location of the damage. Sensors are installed in the truss joints in order to measure the bridge vibration responses under train and ambient excitations. A finite element (FE) model is constructed for the bridge and updated using FE software and experimental data. Both single damage and multiple damage cases are simulated in the bridge model with different scenarios. In each scenario, the vibration responses at the considered nodes are recorded and then used to calculate the transmissibility functions. The transmissibility damage indicators are calculated and stored as ANNs inputs. The outputs of the ANNs are the damage type, location and severity. Two machine learning algorithms are used; one for classifying the type and location of damage, whereas the other for finding the severity of damage. The measurements of the Nam O bridge, a truss railway bridge in Vietnam, is used to illustrate the method. The proposed method not only can distinguish the damage type, but also it can accurately identify damage level.

A simple mathematical model for static analysis of tall buildings with two outrigger-belt truss systems

  • Rahgozar, Reza;Ahmadi, Ali Reza;Hosseini, Omid;Malekinejad, Mohsen
    • Structural Engineering and Mechanics
    • /
    • 제40권1호
    • /
    • pp.65-84
    • /
    • 2011
  • In this paper a simple mathematical model for approximate static analysis of combined system of framed tube, shear core and two outrigger-belt truss structures subjected to lateral loads is presented. In the proposed methodology, framed tube is modeled as a cantilevered beam with a box section and interaction between shear core and outrigger-belt truss system with framed tube is modeled using torsional springs placed at location of outrigger-belt truss; these torsional springs act in a direction opposite to rotation generated by lateral loads. The effect of shear lag on axial deformation in flange is quadratic and in web it is a cubic function of geometry. Here the total energy of the combined system is minimized with respect to lateral deflection and rotation in plane section. Solution of the resulting equilibrium equations yields the unknown coefficients of shear lag along with the stress and displacement distributions. The results of a numerical example, 50 storey building subjected to three different types of lateral loading obtained from SAP2000 are compared to those of the proposed method and the differences are found to be reasonable. The proposed method can be used during the preliminary design stages of a tall building and can provide a better understanding of the effects of various parameters on the overall structural behavior.

스텝 하중을 받는 3-자유절점 공간 트러스 모델의 동적 좌굴 특성 (Dynamic Buckling Characteristics of 3-Free-Nodes Spatial Truss Model Under the Step Load)

  • 손수덕;황경주
    • 한국공간구조학회논문집
    • /
    • 제20권2호
    • /
    • pp.59-68
    • /
    • 2020
  • In this paper, the dynamic snapping of the 3-free-nodes spatial truss model was studied. A governing equation was derived considering geometric nonlinearity, and a model with various conditions was analyzed using the fourth order Runge-Kutta method. The dynamic buckling phenomenon was observed in consideration of sensitive changes to the force mode and the initial condition. In addition, the critical load level was analyzed. According to the results of the study, the level of critical buckling load elevated when the shape parameter was high. Parallelly, the same result was caused by the damping term. The sensitive asymmetrical changes showed complex orbits in the phase space, and the critical load level was also becoming lowly. In addition, as the value of damping constant was high, the level of critical load also increases. In particular, the larger the damping constant, the faster it converges to the equilibrium point, and the occurrence of snapping was suppressed.

내력상태계수 도입을 통한 RC보의 전단강도분석 (Shear Strength Incorporated with Internal Force State Factor in RC Slender Beams)

  • 정제평;김희정;김우
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2003년도 봄 학술발표회 논문집
    • /
    • pp.912-917
    • /
    • 2003
  • In this paper a new truss modeling technique for describing the beam shear resistance mechanism is proposed based on the reinterpretation of the well-known relationship between shear and the rate of change of bending moment in a reinforced concrete beam subjected to combined shear and moment loads. The core of the model is that a new perspective on the shear resistance can be gained by viewing the internal stress filed in terms of the superposition of two base components of shear resistance; arch action and beam action. The arch action can be described as a simple tied-arch which is consisted of a curved compression chord and a tension tie of the longitudinal steel, while the beam action between the two chords can be modeled as a membrane shearing element with forming a smeared truss action. The compatibility of deformation associated to the two action is taken into account by employing an experimental factor or internal state force factor a. Then the base equation of V=dM/dx is numerically duplicated. The new model was examined by the 362 experimental results. The shear strength predicted by the internal force state factor a show better correlation with the tested values than the present shear design.

  • PDF

손상지수법을 이용한 트러스 교량의 손상추정 (Damage Identification in Truss Bridges using Damage Index Method)

  • 이봉학;김정태;장동일
    • 한국강구조학회 논문집
    • /
    • 제10권2호통권35호
    • /
    • pp.279-290
    • /
    • 1998
  • 소수의 진동특성치가 실측된 삼차원 트러스 교량을 대상으로 기존의 손상추정법이 실험되었다. 첫 번째 단계로 진동모드 민감도 해석과 패턴인식기법을 사용하여 초기구조모델(baseline model)이 구성되었고, 다음 단계로 수개의 손상시나리오 수치 예를 초기구조물에 시뮬레이션하고 이를 손상지수와 패턴인식기법을 이용하여 손상위치를 예측하였다. 총 211개 요소에 11개의 부 구조계를 갖는 트러스 구조에 대하여 진동모드가 2개인 경우에 한하여 분석 검토한 결과 손상발견 알고리즘의 적합성이 입증되었다.

  • PDF

해양 케이블 지지구조물의 구조해석을 위한 개선된 유한요소해석모델 (An Improved Finite Element Analysis Model of Offshore Cable-Supported Structures)

  • 김선훈;송명관;노혁천
    • 한국해양공학회지
    • /
    • 제18권6호
    • /
    • pp.51-57
    • /
    • 2004
  • In this study, the improved three-dimensional analysis model designed for a more accurate analysis of marine cable-supported structures, is presented. In this improved analysis model, the beam elements, of which the stability function is derived using Taylor's series expansions, are used to model space frame structures, and the truss elements. The equivalent elastic modulus of the truss elements is evaluated on the assumption that the deflection curve of a cable has a catenary function. By using the proposed three-dimensional analysis model, nonlinear static analysis is carried out for some cable-supported structures. The results are compared with previous studies and show good agreement with their findings.