• 제목/요약/키워드: Triton X

검색결과 346건 처리시간 0.028초

철과 양수성 물질을 이용한 PCE와 크롬 제거에 관한 연구

  • 조현희;천병식;박재우
    • 한국지하수토양환경학회:학술대회논문집
    • /
    • 한국지하수토양환경학회 2004년도 임시총회 및 추계학술발표회
    • /
    • pp.68-71
    • /
    • 2004
  • Effects of surfactants and natural organic matter (NOM) on the sorption and reduction of tetrachloroethylene (PCE) and chromate with iron were examined in this study. PCE and chromate reduction by iron depended on the ionic type of the surfactants in this study. The apparent reaction rate constants of PCE with Triton X-100 and hexadecyltrimethyl ammonium (HDTMA) at one half and two times of the critical micelle concentration (CMC) were relatively higher than without surfactants because of the enhanced PCE partitioning and surface concentration. In the presence of sodium dodecyl benzene sulfonate (SDDBS) at 2000 mg/L and NOM at 50 mg/L, the apparent reaction rate constants of PCE increased, but TCE production decreased. The enhanced removal rate of PCE was not due to the dechlorination, and the sorption was dominant iron with SDDBS and NOM. The apparent reaction rate constants of chromate by iron with Triton X-100 and NOM were 1.4-3.1 times lower than without surfactants while that with HDTMA was two times higher than without HDTMA, When the sorbed HDTMA molecules form admicelles, negatively-charged chromate has an affinity for the positively-charged HDTMA head group.

  • PDF

Receptor Cytoplasmic 영역에 의존하는 EGF의 고친화성 결합 (Dependence of High Affinity Binding of Epidermal Growth Factor on Receptor Cytoplasmic Domain)

  • 강용호
    • KSBB Journal
    • /
    • 제7권3호
    • /
    • pp.201-208
    • /
    • 1992
  • 일부의 EGF receptor 에는 EGF 가 세포표면에서 receptor 와 결합할 때 보다 높은 친화력(high affinity)을 보이고 있는데 그 이유를 설명하기 위해서 EGF receptor 의 cytoplasmic 영역을 절단하여 EGF 와의 친화력을 측정하였다. Scatchard plot 의 결과 1022 아미노산 이하로 절단된 receptor 는 high affinity 특성을 상실하였다. Triton X-100로 세포막을 제거하여 cytoskeleton 이 EGF receptor 의 구조에 미치는 영향을 조사한 결과 cytoskeleton과 결합한 receptor 보다 EGF 에 대해서 더 높은 친화력을 보였다. 따라서 cytoskeleton 이 high affinity EGF receptor 를 형성하는데 영향을 미치고 receptor 와 cytoskeleton 의 가능한 결합부위는 1022-1186 아미노산 사이인 것 같다.

  • PDF

$Eu^{3+}$, TTA, 그리고 n-Octanol의 삼성분착물에 의한 n-Octanol의 분광형광분석법에 관한 연구 (Spectrofluorimetric Determination of n-Octanol Based on its Ternary Complex with $Eu^{3+}$ and TTA)

  • 차기원;박광원
    • 분석과학
    • /
    • 제10권6호
    • /
    • pp.433-438
    • /
    • 1997
  • Triton X-100 계면할성제 존재하에서, $Eu^{3+}$-thenoyltrifluoroacetone(TTA)계의 형광세기의 n-octanol 영향에 관해 연구하였고, n-octanol의 정량을 위한 최적 조건을 규명하였다. 이 착물계에서 들뜨기 파장을 345nm로 주사했을 때, $Eu^{3+}$ 이온의 최대 형광파장은 619nm에서 나타났다. n-octanol의 검정곡선은 $1{\times}10^{-5}M{\sim}1{\times}10^{-7}M$의 범위에서 직선적인 관계를 얻었고, 검출한계는 $1{\times}10^{-9}M$이었다. 이 방법을 이용하여 합성시료를 분석한 결과 분석오차내에서 기지값과 일치하였으며, 상대표준편차는 약 3.5%였다.

  • PDF

흑연료 원자흡수 분광법에 의한 혈중의 납, 카드뮴 정량을 위한 외부정도관리 시료제조 및 분석 (Preparation and analysis of lyophilized whole blood as external quality control materials for Pb and Cd determination by graphite furnace atomic absorption spectrometry)

  • 이공주;임흥빈
    • 분석과학
    • /
    • 제8권3호
    • /
    • pp.273-279
    • /
    • 1995
  • 납과 카드뮴을 포함하는 여러 가지 농도의 동결건조된 혈액이 외부정도관리 시료로서 제조되었다. 이 시료들은 흑연료 원자흡수분광법(GFAAS)을 이용하여 성능이 파악되었다. 매트릭스 개선제로서 0.1% ammonium dihydrogen phosphate와 0.1% Triton X-100을 사용하여 섭씨 600 내지 650도의 회화온도에서 혈액에 있는 납과 카드뮴의 정량 분석을 위한 GFAAS의 최적 분석조건이 얻어졌다. 제조된 혈액의 균질도와 안정도는 최적화된 분석조건에서 연구되었다.

  • PDF

Enhanced Activity of Phenylalanine Ammonia Lyase in Permeabilised Recombinant E. coli by Response Surface Method

  • Cui, Jian-dong;Li, Yan;Jia, Shi-Ru
    • Food Science and Biotechnology
    • /
    • 제18권2호
    • /
    • pp.494-499
    • /
    • 2009
  • To improve phenylalanine ammonia lyase (E.C.4.3.1.5-PAL) activity in recombinant Escherichia coli, Some approaches for improving phenylalanine ammonia lyase (PAL) activity in recombinant E. coli were developed following preliminary studies by means of response surface method. The results shown that permeabilization with combination of Triton X-100, cetyl trimethyl ammonium bromide (CTAB), and acetone enriched cellular recombinant PAL activity significantly, which improved over 10-fold as compared with the control (untreat cell), as high as 181.37 U/g. The optimum values for the tested variables were Triton X-100 0.108 g/L, CTAB 0.15 g/L, and acetone 45.2%(v/v). Furthermore, a second-order model equation was suggested and then validated experimentally. It was indicated that addition of surfactants and organic solvents made the cells more permeable and therefore allowed easier access of the substrate to the enzyme and excretion of the product, which increased the rate of transport of L-phenylalanine and trans-cinnamic acids. These improved methods of PAL activity enrichment could serve as a rich enzyme source, especially in the biosynthesis of L-phenylalanine.

Effect of Post-CMP Cleaning On Electrochemical Characteristics of Cu and Ti in Patterned Wafer

  • Noh, Kyung-Min;Kim, Eun-Kyung;Lee, Yong-Keun;Sung, Yun-Mo
    • 한국재료학회지
    • /
    • 제19권3호
    • /
    • pp.174-178
    • /
    • 2009
  • The effects of post-CMP cleaning on the chemical and galvanic corrosion of copper (Cu) and titanium (Ti) were studied in patterned silicon (Si) wafers. First, variation of the corrosion rate was investigated as a function of the concentration of citric acid that was included in both the CMP slurry and the post-CMP solution. The open circuit potential (OCP) of Cu decreased as the citric acid concentration increased. In contrast with Cu, the OCP of titanium (Ti) increased as this concentration increased. The gap in the OCP between Cu and Ti increased as citric acid concentration increased, which increased the galvanic corrosion rate between Cu and Ti. The corrosion rates of Cu showed a linear relationship with the concentrations of citric acid. Second, the effect of Triton X-$100^{(R)}$, a nonionic surfactant, in a post-CMP solution on the electrochemical characteristics of the specimens was also investigated. The OCP of Cu decreased as the surfactant concentration increased. In contrast with Cu, the OCP of Ti increased greatly as this concentration increased. Given that Triton X-$100^{(R)}$ changes its micelle structure according to its concentration in the solution, the corrosion rate of each concentration was tested.

모기유충에 살충력이 있는 Bacillus thuringiensis subsp. darmstadiensis 73E10-2의 delta-endotoxin의 화학적 처치에 따른 안정성 (Stability on Chemical Treatment of Niosquitocidal delta-endotoxin from Bacillus thuringiensis subsp. darmstadiensis 73E10-2)

  • 김광현;조경순;이광배
    • 한국미생물·생명공학회지
    • /
    • 제19권3호
    • /
    • pp.308-312
    • /
    • 1991
  • B.thuringiensis subsp. darmstadiensis 73E10-2의 내독소에 대한 화학적 처리에서 고농도의 중성염(4M NaBr), 유기용매(50% acetone), 변성제(4M urea) 및 중성 계면활성제(10% triton X-100)로 내독소를 처리하였을 때 모기유충에 대한 독력의 소실이 거의 나타나지 않았으나, guanidine HCL이나 $CCl_4$ 또는 양이온 및 음이온 계면활성제로 처리함으로써 그 독력이 크게 소실되었다. 또한, 내독소의 sulfhydryl기의 변형은 모기유충에 대한 독력에 영향을 나타내지 못하였으나, lysine기 변형으로 내독소의 독력이 거의 완전히 소실되었다.

  • PDF

Smith-Hieftje(SH) 및 $D_2$ 바탕보정장치가 부착된 흑연로 원자흡수분광법을 이용한 혈액 중 카드뮴 분석 (Analysis of Cadmium in Blood using SH(Smith-Hieftje) and $D_2$ Arc Background Correction Methods by Graphite Furnace Atomic Absorption Spectrophotometer)

  • 이석기;김풍작;정창웅
    • 대한화학회지
    • /
    • 제40권3호
    • /
    • pp.196-201
    • /
    • 1996
  • 혈액 중 미량 카드뮴 분석에 전기로 장치가 부착된 원자 흡수 분광광도계(GFAAS)를 사용하였다. 시료를 1% Triton X-100으로 10배 희석시킨 다음 회화 온도 500$^{\circ}C$에서 Fork platform흑연 튜브를 사용하여 분석하였으며, 결과 처리는 피크 면적법과 피크높이법으로 비교하였다. 양쪽 모두 우수한 값을 얻을 수 있었으며 SH 바탕보정법과 $D_2$ 바탕보정법에 의하여 얻은 검출한계는 각각 0.02ng/mL와 0.01ng/mL이고 상대 표준편차는 1.0ng/mL 종도에서 5%이내였다. 분석의 정확성을 평가하기 위하여 노르웨이 Nycomed Pharma사의 Seronorm (Trace Elements Whole Blood)을 분석, 비교 검토 하였다.

  • PDF

Effect of Surfactants on the Electrochemical Performance of Cation-Selective Membrane Electrodes

  • Oh, Hyun-Joon;Cha, Geun-Sig;Nam, Hak-hyun
    • Bulletin of the Korean Chemical Society
    • /
    • 제24권1호
    • /
    • pp.37-44
    • /
    • 2003
  • We examined the effect of polyether-type nonionic surfactants (Brij 35, Triton X-100, Tween 20 and Tween 80) on the potentiometric properties of sodium-, potassium- and calcium-selective membranes which are prepared with widely used ionophores and four kinds of polymer matrices [poly(vinyl chloride) (PVC), polyurethane (PU), PVC/PU blend, and silicone rubber (SR)]. It was found that the PVC-based membranes, which provide the best performance among all other matrix-based membranes in the absence of nonionic surfactants, exhibited larger change in their potentiometric properties when nonionic surfactants are added to the sample solution. On the other hand, the sodium-selective SR-based membrane with calix[4]arene, potassium-selective PVC/PU- or SR-based membrane with valinomycin, and the calcium-selective SR-based membrane with ETH 1001 provide almost identical analytical performance in the presence and absence of Tween 20 or Tween 80 surfactants. The origin of nonionic surfactants effect was also investigated by interpreting the experimental results obtained with various matrices and ionophores. The results suggest that the nonionic surfactant extracted into the membrane phase unselectively form complexes with the primary and interfering ions, resulting in increased background potential and lower binding ability for the ionophore. Such effects should result in deteriorated detection limits, reduced response slopes and lower selectivity for the primary ions.

Determination of Trace Amounts of Lead and Copper in Water Samples by Flame Atomic Absorption Spectrometry after Cloud Point Extraction

  • Shemirani, Farzaneh;Abkenar, Shiva Dehghan;Khatouni, Asieh
    • Bulletin of the Korean Chemical Society
    • /
    • 제25권8호
    • /
    • pp.1133-1136
    • /
    • 2004
  • The need for highly reliable methods for the determination of trace metals is recognized in analytical chemistry and environmental science. A method based on the cloud-point extraction (CPE) technique for the trace analysis of Pb and Cu in water samples is described in this study. The analytes in the initial aqueous solution are complexed with pyrogallol, and 0.1%(w/v) Triton X-114 is added as surfactant. Following phase separation at $50^{\circ}C$, based on the cloud point of the mixture and dilution of the surfactant-rich phase with acidified methanolic solution, the enriched analytes are determined by flame atomic absorption spectrometry. After optimization of the complexation and extraction conditions, the enrichment factors of Pb and Cu were found to be 72 and 85, respectively. Under optimum conditions, the preconcentration of 60 mL of samples in the presence of 0.1%(w/v) Triton X-114 permitted the detection of 0.4 ${\mu}gL^{?1}$ of Pb and 0.05 ${\mu}gL^{?1}$ of Cu. The proposed method was applied successfully to the determination of Pb and Cu in water samples.