• 제목/요약/키워드: Tripping characteristics

검색결과 41건 처리시간 0.023초

선택지락보호계전기 오.부동작에 관한 연구 (Study on the Ground Fault Protection in 6.6KV Ungrounded Power System SGR Malfunction or Non-Tripping)

  • 김병태;이달우;전명수
    • 전기학회논문지P
    • /
    • 제57권3호
    • /
    • pp.296-301
    • /
    • 2008
  • This paper presents a study on the ground fault protection in 6.6KV ungrounded power system relay(SGR) malfunction or non-tripping. Ground test had made on 6.6KV HV(high voltage) system, Some of domestic and oversea's SGR products are different from their own specific characteristics. This study on the ground protection relay 6.6KV power supply system is focused to protect human.

노인의 주택내 사고발생에 영향을 미치는 요인에 관한 연구 (Characteristics Related to Domestic Accidents of the Elderly)

  • 곽인숙
    • 가정과삶의질연구
    • /
    • 제27권4호
    • /
    • pp.55-66
    • /
    • 2009
  • Nearly a half of the accidents the old people had take place in home. Home safety will be more important than ever in rapidly increasing old aged in Korea. The purpose of this paper is to search the general characteristics of domestic accidents related to living environment of the old people experienced. The number of 248 respondents who had experienced of housing related accidents since recent 10 years were selected from 500 interviews with 65 years old and over during April 4th-26th, 2008. About a half of respondents had experienced home accidents. The entrance is the most common places the home accidents occurred, followed by bathrooms and stairs. flooring materials and raised floors are the most dangerous spots. Both places and dangerous objects are related each other. The place is also related to the type of dwelling. Slipping and tripping over most frequently happen in home accidents. It is related to the place like slipping in a bathroom or stairs, and tripping over in entrances. Mostly, legs and arms are injured by the home accidents. A safe home facilitates the old to live healthy and independent in their own places. A safe home for the old is a kind of new issues in Korea. Related policies and researches are about to sprout.

도림천에서 발생한 고립 및 실족사고의 원인분석을 통한 개선방안 도출에 관한 연구 (Cause Analysis and Improvement Suggestion for Flood Accident in Dorimcheon - Focused on the Tripping and Isolation Accidents)

  • 이경수;전종형;김태훈;김현주
    • 한국산학기술학회논문지
    • /
    • 제22권4호
    • /
    • pp.25-36
    • /
    • 2021
  • 본 연구는 도림천에서 발생한 고립 및 실족과 같은 수난사고의 근본적인 원인을 분석하고, 법·제도적인 개선방안을 제시하였다. 원인분석을 위하여 현장확인, 관계자 인터뷰, 관련자료 검토, 강우량과 하천 횡단면의 수위와의 관계, 자동경보 발령 기준수위의 적정성 및 진·출입 통제에 따른 대피시간 확보 가능여부 등을 평가 하였다. 도림천은 전형적인 도시하천의 특성을 띄고 있어 치수적으로 불리하며, 사망사고가 발생한 구간은 급만곡부를 형성하고 있는 등 고립사고 발생 위험이 높다. 고립 및 실족사고는 홍수주의·경보 발령 전 단계인 둔치주의·대피 단계에서 발생하고 둔치대피 발령은 둔치턱까지 수위가 상승해서야 발령되기 때문에 있기 때문에 강우예보에 따른 수위상승에 대한 즉각적인 대응이 중요하다. 또한, 수위 상승속도가 신림3교와 관악도림교에서 최대 2.62 cm/min임을 고려하였을 때 둔치경보 발령 후 충분한 대피시간을 확보하고 있지 못하다. 사망사고는 둔치주의 발령 기준수위보다 0.46 m이하에서 발생한 점을 보았을 때, 하천의 진·출입 등 통제가 사고 예방을 위해서는 매우 중요하다. 이러한 분석결과를 바탕으로 4건의 개선방안을 제시하였으며, 고립 및 실족과 같은 수난사고를 예방하는데 크게 기여할 수 있을 것으로 기대한다.

고조파 전류에 의한 배선용 차단기 동작 특성 (Operating Characteristics of Molded Case Circuit Breakers by Harmonic Currents)

  • 전정채;유재근;이상익
    • 조명전기설비학회논문지
    • /
    • 제20권2호
    • /
    • pp.68-74
    • /
    • 2006
  • 고조파 전류에 의한 배선용 차단기 오동작 및 원인불명 동작이 보고되고 있으나 고조파 전류에 의한 배선용 차단기 동작을 설명할 수 있는 자료가 없는 실정이다. 본 논문에서는 네 가지 형태의 배선용 차단기(열동식, 열동 전자식, 완전 전자식 및 전자식)에 대해 고조파 전류의 영향을 시험하였다. 실험 결과 정격전류 이하의 고조파가 포함된 시험 전류에서는 어떤 종류의 배선용 차단기에서도 오동작은 발생하지 않았다. 그리고 다양한 고조파 부하 조건에서 열동식과 열동 전자식의 경우 제조사의 동작 시간에 별다른 영향을 보이지 않았다. 그러나 완전 전자식 차단기는 과부하 조건에서 고조파 전류가 증가할 수 록 동작 시간이 점차 둔화되었고 이는 케이블 과열을 야기할 수 있을 것이다. 따라서 고조파 전류가 심한 곳에서는 완전 전자식 배선용 차단기의 사용을 피해야 할 것이다.

용접된 보강판의 압축 최종 강도의 간이 해석법 (A Simplified Approach to the Analysis of the Ultimate Compressive Strength of Welded Stiffened Plates)

  • 장창두;서승일
    • 대한조선학회논문집
    • /
    • 제30권2호
    • /
    • pp.141-154
    • /
    • 1993
  • 본 논문에서는 주변 단순 지지된, 용접된 편면 보강판의 압축 최종 강도를 구하는 간략한 방법을 제안하고자 한다. 우선, 용접에 의한 변형 및 잔류응력과 같은 초기결함을 간략한 방법으로 추정하고, 이 초기결함이 존재하는 보강판의 붕괴 양식을 가정하여, 각 양식에 대해 최종 강도를 구하고, 여러 붕괴 하중에 때해 최소치를 택함으로 보강판의 붕괴 하중을 얻는다. 보강판이 최종 강도 상태에 달하기까지 붕괴 과정을 다음과 같이 가정한다. (1) 보강판의 전체 좌굴$\rightarrow$보강재의 굽힘에 의한 전체 붕괴 (2) 판재의 국부 좌굴$\rightarrow$판재의 국부 붕괴$\rightarrow$보강재의 전단면 항복에 의한 전체 붕괴 (3) 판재의 국부 좌굴$\rightarrow$보강재의 굽힘에 의한 전체 붕괴 (4) 판재의 국부 좌굴$\rightarrow$판재의 국부 붕괴$\rightarrow$보강재의 비틂 변형(tripping)에 의한 전체 붕괴 붕괴 하중 계산을 위해 Rayleigh-Ritz 법에 기초한 탄소성 대변형 해석을 수행하고, 소성 붕괴선을 가정한 소성 해석을 수행하여 탄성 해석선과 소성 해석선의 교점을 최종 강도로 택한다. 본 방법을 비선형 유한요소법과 비교해 보면 극히 짧은 계산 시간에 양호한 결과를 산출한다는 것을 알 수 있다. 본 방법에 의한 해석 결과를 통해 판재의 국부 거동에 미치는 보강재의 비틂 강성의 효과를 고찰하였고, 보강재의 굽힘에 의한 전체붕괴와 비틂 변형(tripping)에 의한 전체 붕괴의 기준이 되는 보강재의 형상을 제시할 수 있었다.

  • PDF

평판 근접 후류에서 경계층의 유동조건에 따른 레이놀즈 응력분포 (Reynolds Stress Distribution on Boundary Layer Flow Conditions in the Near-Wake of a Flat Plate)

  • 김동하;장조원
    • 한국분무공학회지
    • /
    • 제9권4호
    • /
    • pp.53-66
    • /
    • 2004
  • An experimental study was carried out in order to investigate the influence of flow conditions on a boundary layer in the near-wake of a flat plate. The flow conditions in the vicinity of the trailing edge that is influenced by upstream condition history are an essential factor that determines the physical characteristics of a near-wake. Tripping wires attached at various positions were selected to change flow conditions of a boundary layer. The flows such as laminar, transitional, and turbulent boundary layer at 0.98C from the leading edge are imposed in order to investigate the evolution of symmetric and asymmetric wake. An x-type hot-wire probe(55P61) is employed to measure at 8 stations in the near-wake. Test results show that the near-wake for the case of a turbulent boundary layer is relatively insensitive to instability after separating at the trailing edge, and Reynolds shear stress in the near-wake for the case of a turbulent boundary layer collapses due to turbulent kinetic energy.

  • PDF

누전차단기의 뇌써지 동작특성 분석 및 오동작 대책 (Analysis and Countermeasures for False-Tripping of Earth Leakage Breaker Due to Lightning Surge)

  • 이재복;명성호;조연규;장석훈;김점식
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제51권10호
    • /
    • pp.479-484
    • /
    • 2002
  • Recently it is reported that many a malfunction of ELB which is represented by non-operated type ELB for an impulse wave, is caused by lightning impulse and transient ground potential rise due to nearby lightning strokes. In order to examine the cause of malfunction, 5 samples were investigated experimentally in this study. As each ELB has a different leakage current detecting circuit and wiring method, various characteristics were measured. As a result, all of them brought about malfunctions under the lightning impulse voltage less than 7 kV and the surge current less than 3 kA. Also the different aspects were measured with a polarity of injected surge and a position of MOV to protect the inner circuit of ELB. The Position and effects of protecting devices were suggested as a remedy.

노후화된 누전차단기의 과전류 동작 특성에 관한 연구 (A Study on the Operating Characteristics of the Aged ELCB according to the Overcurrent)

  • 박예진;강신동;김재호
    • 한국안전학회지
    • /
    • 제38권5호
    • /
    • pp.1-7
    • /
    • 2023
  • This study analyzes the operational characteristics of 311 aged and non-aged residual current circuit breakers (RCCBs) in low-voltage consumer contexts. It investigates the influence of external temperature and harmonics based on the rated current multiples. To simulate temperature variations, a convectional oven was used around the circuit breakers. Additionally, the generation of harmonic reference signals and data measurement for overcurrent experiments were conducted using NI SCXI, myDAQ, and LabVIEW. An observation revealed that as the ambient temperature increased, the operating time of RCCBs decreased in the time delay region. This was attributed to the faster response or bending of the bimetal, which is the tripping element. However, aged RCCBs encountered challenges with tripping outside the protective curve. The operating time of the circuit breakers exhibited an acceleration influenced by the order and content of harmonic currents, potentially leading to malfunctions. Aged RCCBs demonstrated faster operating times than their non-aged counterparts. However, the difference in operating time varied based on the manufacturer's and operating environment of the RCCBs. Frequent malfunctions of RCCBs can result in power outages. In cases where these circuit breakers fail to operate, they can lead to secondary damages, including electrical fires and shocks. Consequently, it is imperative to consider the operating environment of RCCBs and provide appropriate replacement cycles to mitigate these risks.

SOME MECHANICAL FACTORS AFFECTING MACHINE MILKING CHARACTERISTICS UNDER SEMI-ARID CONDITION

  • Ali, A.K.A.;Farah, D.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • 제5권3호
    • /
    • pp.475-480
    • /
    • 1992
  • The effect of mechanical factors and season of the year on milking characteristics (milk yield, time of milking, rate of milk flow, stripping time and tripping milk) were studied on 26 Holstein Friesian cows, raised under Saudi Arabia environmental conditions. Cows were in the third and fourth lactation and reached the peak. Cows milked twice a day with equal intervals. Three vacuum levels (34, 38 and 42 cfm) and two pulsation ratios were used to form six vacuum-pulsation combinations. The study was carried during two seasons Autumn-Winter (S1) and Spring-Summer (S2). After absorbing the cow equations least square analysis was used to analyze the data. Vacuum level 38 cfm and pulsation ratio 70:30 was the best among all combinations of vacuum level-pulsation ratio. No significant effect (p < .01) for season, up to the seventh half minute, on the rate of milk flow. However, season of the year has a significant effect on total milk yield, stripping time and stripping milk.

The Gender Difference in the Occupational Hazards and Injuries of Cleaning Workers and Janitors

  • Choi, Chang Lyul
    • 대한인간공학회지
    • /
    • 제36권5호
    • /
    • pp.411-420
    • /
    • 2017
  • Objective: The purpose of this study is to analyze the accident characteristics according to the gender of the injured workers in building cleaning and to reflect them in the Industrial Accident Prevention Policy. Background: An analysis of industrial accidents is an essential process for establishing systematic industrial accident prevention measures. In order to establish industrial accident prevention measures for workers effectively, it is necessary to analyze accident characteristics by job type for workers who do the same work. Method: In this study, we analyzed the accident characteristics of 1,645 janitors who were approved of work-related injuries in 2015. We also analyzed the characteristics according to gender by dividing them into worker-related factors and accident-related factors. Results: The accidents caused to the janitors showed different characteristics according to gender, age, work experience, agency of accident, and distribution of original cause materials. In other words, 70.2% occurred to workers over 60 years old and 56.2% occurred to unskilled workers with less than a year of work experience. In the case of accident pattern, 79.1% occurred in tripping (slip) hazards, and 68.2% of accidents occurred on the floor (including the ground) and the stairs, indicating that the accident occurred most frequently during cleaning work on the floor or stairs. Conclusion and Application: The results of the study on the accident characteristics of the janitors can be used as basic data for systematic preventive measures against accidents occurring to the elderly female workers in the service industry.