• Title/Summary/Keyword: Trip Line

검색결과 117건 처리시간 0.042초

FLB Event Analysis with regard to the Fuel Failure

  • Baek, Seung-Su;Lee, Byung-Il;Lee, Gyu-Cheon;Kim, Hee-Cheol;Lee, Sang-Keun
    • 한국원자력학회:학술대회논문집
    • /
    • 한국원자력학회 1996년도 춘계학술발표회논문집(2)
    • /
    • pp.622-627
    • /
    • 1996
  • Detailed analysis of Feedwater Line Break (FLB) event for the fuel failure point of view are lack because the event was characterized as the increase in reactor coolant system (RCS) pressure. Up to now, the potential of the rapid system heatup case has been emphasized and comprehensively studied. The cooldown effects of FLB event is considered to be bounded by the Steam Line Break (SLB) event since the cooldown effect of SLB event is larger than that of the FLB event. This analysis provides a new possible path which can cause the fuel failure. The new path means that the fuel failure can occur under the heatup scenario because the Pressurizer Safety Valves (PSVs) open before the reactor trips. The 1000 MWe typical C-E plant FLB event assuming Loss of Offsite Power (LOOP) at the turbine trip has been analyzed as an example and the results show less than 1% of the fuel failure. The result is well within the acceptance criteria. In addition to that, a study was accomplished to prevent the fuel failure for the heatup scenario case as an example. It is found that giving the proper pressure gap between High Pressurizer Pressure Trip (HPPT) analysis setpoint and the minimum PSV opening pressure could prevent the fuel failure.

  • PDF

2회선 송전선로에서 상호임피던스와 고장저항을 고려한 거리계전기의 동작 특성 연구 (A Study on Adaptive Distance Protection of Double-circuit Line with Mutual Impedance and Fault Resistance)

  • 이원석;정창호;이준경;김진오
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 하계학술대회 논문집 A
    • /
    • pp.317-319
    • /
    • 2003
  • This paper describes an adaptive distance relay for double-circuit line protection with mutual impedance and fault resistance. Double-circuit lines have two operating condition; both lines of a double-circuit line are in operation and one line is switched-off and both ends of the line are grounded. For optimal distance protection, the trip region is calculated, which have respect to mutual impedance and fault resistance.

  • PDF

Improvement of Power Capability and Field Uniformity with Tapered Coaxial Matching Units in Strip Line for Measuring Electromagnetic Immunity of Vehicular Components

  • Chung, Yeon-Choon;Kang, Tae-Won;Park, Dong-Chul
    • Journal of Electrical Engineering and information Science
    • /
    • 제2권5호
    • /
    • pp.60-64
    • /
    • 1997
  • The design process and construction method of a strip line is described for measuring radiated susceptibility of vehicular components having electrical cables more than 2 min length. he characteristic impedance of the trip line was determined 90$\Omega$ to obtain the field uniformity of $\leq$${\pm}$3 dB in the frequency range from 100 kHz to 500 MHz. Tapered coaxial lines were used instead of the traditional lumped circuit element for the impedence matching units, therefore, the strip line has high power capability. Using these techniques, the field uniformity and power capability of a strip line could be considerably improved.

  • PDF

해제시간에 따른 열차예매시간의 영향 분석: 경부선 KTX를 중심으로 (Analyzing Effects of the Ticket Release Time on Train Reservation Time: Focusing on KTX Gyeongbu-line)

  • 김수재;추상호;손병희
    • 한국ITS학회 논문지
    • /
    • 제16권1호
    • /
    • pp.38-49
    • /
    • 2017
  • 일반적으로 철도운영기관에서는 수익성 극대화를 위해 티켓팅 해제시간을 적용하여 티켓을 판매하고 있다. 본 연구에서는 이같은 해제시간이 KTX 예매행태에 어떻게 영향을 미치는지를 분석하였다. 예매행태는 예매시간을 의미하며 예매시각과 출발시각의 차이로 계산하였다. 분석자료는 KTX 경부선 매표자료이며, 요일별 차이를 보기위해 평일(목요일)과 토요일, 일요일의 자료를 이용하였다. 예매시간에 미치는 요인으로 해제시각이외에 요일, 운행거리, 운행방향 등을 고려하였다. 분석결과, 대부분 출발 3시간 전에 티켓을 예매하는 것으로 나타났으며, 주말 상행노선 이용객의 경우 대부분이 출발 하루 전에 예매를 하는 것으로 나타났다. 또한 해제시간 전에는 상행노선, 장거리 구간, 일요일인 경우에 예매시간이 길게 나타났으며, 반면에 해제시간 이후에는 일요일인 경우와 장거리 구간인 경우에 예매시간이 짧게 나타났다.

Elman Network를 이용한 거리계전기법의 신뢰성 향상 (An Improvement of Distance Relay Technique Reliability using Elman Network)

  • 정호성;이종주;신명철;이복구;박철원;장성익
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 A
    • /
    • pp.212-214
    • /
    • 2000
  • The distance relay technique used for transmission line protection operates overreach and underreach to the self protection region because the power system becomes complex and fault conditions are different. To solve these problems, this paper describes new technique to set the reliable self protection lesion. The trip region of the quadrilateral distance relay is set by training of multi layer recurrent elman network. The proposed network is able to reach the trip zone for the fault impedance, fault initial angle and source impedance variance correctly.

  • PDF

분산형 발전고객의 OCGR오동작 및 과부족 계량에 대한 사례연구 (A Case Study on Malfunction of OCGR and Inaccuracy of Watt-hour Meter in Distributed Generation System)

  • 신동열;박용우;차한주
    • 전기학회논문지
    • /
    • 제57권8호
    • /
    • pp.1349-1355
    • /
    • 2008
  • The paper shows the analysis of operating conflict of OCGR trip events and metering errors in the photovoltaic generation, wind generation distributed generation customers with no defect of the distributed generation facilities, which are connected to 22.9kV distribution lines. To analyze problems with metering errors and OCGR fault event, a power quality analyzer and PSIM program were used to test the field and to simulate in Sun-Cheon photovoltaic generation and Seo-Cheon photovoltaic generation customers. With the trial distribution line, the result of analysis was verified to prove with the same situation of the actual field. This paper suggests short term and long term countermeasures of OCGR fault events, analysis of over and shortage of metering errors in distributed generation customers.

도시철도 건설사업의 편익계측에 관한 한일 비교연구 (Comparative Study on Benefit Evaluation of Urban Rail Construction Project : Korea vs Japan)

  • 최창식;김경철;김용일
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 1999년도 추계학술대회 논문집
    • /
    • pp.17-26
    • /
    • 1999
  • This paper studies on the benefit evaluation of urban railway construction project. We compares Korean Method with Japanese in calculating the generalized cost(GC) of a trip. In Japan, the disadvantage of transferring to another mode or line is included to calculate GC of trip. And environmental effects are contained directly as rail construction benefit. But in Korea, inconvenience of transferring facilities like stairways and passageway for riding a subway is not accounted to analyse benefit. As a result, there is a little investigate to improve and overcoming the inconvenience facilities of transfer, access, and egress. So, we suggest the containing the disadvantage measure of transferring facilities when subway riderships are forecasted. That will be reduced tile capital size of subway.

  • PDF

600MPa급 TRIP강의 $CO_2$ 및 Nd:YAG 레이저 용접부의 특성 (Characteristics of $CO_2$ or Nd:YAG Laser Welded 600MPa Grade TRIP Steel)

  • 한태교;김성준;이봉근;김대업;강정윤
    • Journal of Welding and Joining
    • /
    • 제24권1호
    • /
    • pp.56-63
    • /
    • 2006
  • The characteristics of $CO_2$ or Nd:YAG laser welded 600MPa ade TRIP steel was investigated. He or Ar gas was used as a shield gas in case of $CO_2$ laser welding, but the shield gas was not used in case of Nd:YAG laser welding. Bead on plate welding was performed with various welding conditions. Defects in the joints of both welding type occurred at 1.8m/min but were not observed over the welding speed of 2.1m/min in case of Nd:YAG laser welding. However, porosity occurred in $CO_2$ laser welding and the tendency of decreasing with the increase of welding speed. The hardness was the highest at heat affected zone near fusion zone as well as at the fusion zone and decreased on approaching the base metal. In a perpendicular tensile test to the weld line, all specimens that have been welded at optimum conditions were fractured at the base metal, and the tensile properties showed the rather higher than those of raw material. In a parallel tensile test, the strength of the joints was higher than that of the base metal. Elongation was found to be lower than that of the raw material. Forming height by Erichsen test and elongation were deeply related with the ratio of base metal/weld metal and the maximum hardness of the weld metal. Also porosity induced to decrease the strength and the elongation. The maximum formability was recorded at approximately 80% as compared with that of the raw material with the optimum condition.

CMnAl TRIP Steel Surface Modification During CGL Processing

  • Gong, Y.F.;Lee, Y.R.;Kim,, Han-S.;Cooman, B.C.De
    • Corrosion Science and Technology
    • /
    • 제9권2호
    • /
    • pp.81-86
    • /
    • 2010
  • The mechanisms of selective oxidation of intercritically annealed CMnAl TRIP steels in a Continuous Galvanizing Line (GCL) were studied by cross-sectional observation of the surface and sub-surface regions by means of High Resolution Transmission Electron Microscopy (HR-TEM). The selective oxidation and nitriding of an intercritically annealed CMnAl TRIP steel in a controlled dew point 10%$H_2+N_2$ atmosphere resulted in the formation of c-xMnO.$MnO_2$ (1${\leq}$x<3) and c-xMnO.$Al_2O_3$ ($x{\geq}1$) particles on the steel surface. Single crystal c-xMnO.$SiO_2$ ($2{\leq}x{\leq}4$) oxide particles were also observed on the surface. A thin film of crystalline c-xMnO.$SiO_2$ (2${\leq}$x<3) and c-xMnO.$Al_2O_3$ ($x{\geq}1$) was present between these particles. In the sub-surface region, internal oxidation, nitriding and intermetallic compound formation were observed. In the first region, large crystalline c-xMnO.$SiO_2$ ($1{\geq}x{\geq}2$) and c-xMnO.$Al_2O_3$ ($x{\geq}1$) oxides particles were present. In the second region, c-AlN particles were observed, and in a third region, small $MnAl_x$ (x>1) intermetallic compound particles were observed.

780 MPa급 TRIP강의 저항 점용접부 강도 및 파단에 미치는 Paint Baking의 영향 (Effect of Paint Baking on the Strength and Failure of Spot Welds for 780 TRIP Steels)

  • 손종우;남대근;김동철;박영도
    • Journal of Welding and Joining
    • /
    • 제28권2호
    • /
    • pp.66-73
    • /
    • 2010
  • Conventional fracture test of resistance spot weld had been performed without consideration of paint baking process in automobile manufacturing line. This study was aim to investigate the effect of paint baking on fracture mode and load carrying capacity in fracture test for resistance spot welded 780TRIP steels. With paint baking cycle after resistance spot welds, peel tests and microhardness were conducted on the as-welded and baked samples. Resistance spot welds in AHSS (Advanced High Strength Steels) are prone to display partial interfacial fractures during fracture test or vehicle crash. Baking cycle increased the load-carrying capacity of the resistance spot welded samples and improved the fracture appearance from partial to full button fracture for the L-type peel tests. Specially, the differences in fracture appearance are apparent when the nugget size of spot welds is small enough to produce the partial interfacial fracture. The comparison of macrohardness and microstructure between as-welded and baked samples showed that there are no large difference in change the fracture mode. However, the results of the instrumented indentation test suggested that fusion zone and HAZ of baked sample have less tensile and yield strength and proves that the tempering effects are applied and enhanced the resistance to fracture on welds with application of baking cycle.