• Title/Summary/Keyword: Tricuspid valve, replacement

Search Result 140, Processing Time 0.02 seconds

Tricuspid Valve Repair in the Patients with Mitral Valve Replacement - Preoperative and Postoperative Evaluation by Doppler Echocardiography - (승모판 질환시 동반되는 삼첨판 폐쇄븟전증의 비침습적 치료판정 및 그 결과: 도플러 심에코에 의한 수술전후 판정)

  • Choe, Jong-Beom;Yun, Jae-Do;Jeong, Jin-Won
    • Journal of Chest Surgery
    • /
    • v.24 no.4
    • /
    • pp.323-330
    • /
    • 1991
  • Residual significant tricuspid regurgitation after mitral valve operation may significantly increase postoperative morbidity and mortality. However, routine techniques to detect tricuspid regurgitation preoperatively and postoperatively are not accurate. Doppler echocardiography was performed preoperatively and postoperatively to assess its ability to evaluate and quantify the severity of tricuspid regurgitation. In 34 patients with tricuspid regurgitation secondary to mitral valvular disease the tricuspid regurgitations were semiquantified on a scale of 1 to 3+. The 34 patients were divided into two groups on the basis of severity of tricuspid regurgitation as assessed by preoperative Doppler echocardiography. Group I [8 patients] had mild[1+] regurgitation, and group II [26 patients] had moderate to severe[2 ~ 3%] tricuspid regurgitation. In all studied patients, preoperative Doppler echocardiographic studies for the degree of tricuspid regurgitation were correlated with clinical symptoms[including NYHA class] and hemodynamics[JVP and right ventricular systolic pressure], and used as the indicator to determine whether tricuspid annuloplasty should be performed or not. Patients with significant tricuspid regurgitation[group II ] had greater preoperative right ventricular systolic pressures and NYHA classes, although there was no correlation between them. The 8 patients with mild[1+] tricuspid regurgitation[group I ] didn`t undergo any procedure for the tricuspid regurgitation and their postoperative Doppler echocardiographic studies showed the less than mild[0 ~ 1+] tricuspid regurgitation, and the 26 patients with significant[>2+] tricuspid regurgitation, and the 26 patients with significant[>2+] tricuspid regurgitation[group II ] underwent tricuspid annuloplasty for the tricuspid regurgitation and the postoperative Doppler echocardiographic studies showed the findings similar to group I except 1 patient who underwent Carpentier`s ring annuloplasty and had severe right ventricular failure. Therefore, preoperative Doppler echocardiography can accurately assess the relative severity of tricuspid regurgitation. Importantly, postoperative Doppler echocardiography could conveniently determine the effect of tricuspid annuloplasty for the patients with significant tricuspid regurgitation. Doppler echocardiography may be an important diagnostic method both for evaluating the degree of residual tricuspid regurgitation after left heart operation as well as for determining which patients should undergo tricuspid valve repair.

  • PDF

A Clinical Study for Return to Work after Heart Valve Replacement - A Case Report - (심장판막 치환술후 직업복귀에 대한 임상적 고찰)

  • 김현경
    • Journal of Chest Surgery
    • /
    • v.24 no.10
    • /
    • pp.967-972
    • /
    • 1991
  • Between Feb. 1982 and July 1990, 173 patients [male: 89, female: 84] Who underwent heart valve replacement for acquired valvular heart disease on the Department of Thoracic and Cardiovascular Surgery, School of Medicine, Pusan National University, were reviewed for return to work after heart valve replacement. The replaced valve were mitral [128, 74.0%], aortic[10, 5.8%], mitral & aortic[35, 20.2%]. Two tricuspid valve replacement were excluded. Several important factors influencing the return to work were age, the employment status before surgery, the number of replaced valve, the pre - op NYHA functional class and cardiac function [ejection fraction]. These factors were closely related to the optimal time of heart valve replacement. It can be concluded that the rate of return to work and the quality of life would be improved if valve replacement were performed at an earlier stage of valvular heart disease.

  • PDF

Tricuspid Valve Repair for Tricuspid Valve Insufficiency Following a Cardiac Stab Injury - One case report - (심장 자상 후에 발생된 삼첨판막 폐쇄부전의 삼첨판막 성형술 - 1예 보고 -)

  • Kim, Dong-Hyun;Lee, Seong-Jin;Lee, Chol-Sae;Lee, Kihl-Rho;Lee, Seock-Yeol
    • Journal of Chest Surgery
    • /
    • v.40 no.5 s.274
    • /
    • pp.376-379
    • /
    • 2007
  • A 51-year-old male was admitted three month previously with a cardiac stab injury and he underwent direct cardiac repair He had no problem after this event. He complained of dyspnea that stalled 2 months after the original injury. Echocardiography showed severe tricuspid regurgitation and so, chordac replacement and ring annuloplasty was performed. Herein we report on a case of tricuspid valve repair for treating tricuspid insufficiency following a cardiac stab injury.

Clinical Analysis of Bjork-Shiley Mechanical Valve Replacement (Bjork-Shiley 기계판막의 임상적 연구)

  • 김병열
    • Journal of Chest Surgery
    • /
    • v.22 no.3
    • /
    • pp.393-401
    • /
    • 1989
  • Between Dec. 1984, and May, 1988,96 prostheses were implanted in 80 patients at Dept. of Thoracic k Cardiovascular Surgery of National Medical Center. 43 patients had mitral valve replacement, 21 underwent aortic valve replacement, and 15 had double valve replacement [Mitral k Aortic], and 1 had tricuspid valve replacement. Seventy-one cases [88.8 %] were in NYHA Class III or IV. The mean duration of follow up was 22.1 months and follow-up information was available for 74 [92.5 %] of the patients. The overall actuarial survival rate at 45 months was 93.05 % and overall hospital mortality was 10 %, late Mortality was 5 %. The linearlized incidence of thromboembolism [2.4%/pt-yr], thrombotic valve obstruction [1.6 %/pt-yr], anticoagulant related bleeding [0.8 %/pt-yr]. There were no fatal valve related complications. The blood was studied in 40 patients 1 year after valve operation. Hgb and reticulocyte count were within normal values and Serum LDH value was slightly elevated but it was not of clinical significance. In conclusion, Monostrut Bjork-Shiley valve prosthesis to be a reliable valve substitute with an acceptable incidence of complications.

  • PDF

개심술에 관한 연구1979년도 320례 분석

  • 이영균
    • Journal of Chest Surgery
    • /
    • v.13 no.1
    • /
    • pp.1-12
    • /
    • 1980
  • In 1979 during the period of about 10 months 320 cases of open heart surgery were done in Seoul National University Hospital. There were 220 Congenital anomaly cases consisting of 113 acyanotic and 107 cyanotic varieties, and 1 O0 acquired cardiac lesions. Out of 100 acquired lesions 96 were valvular cues. Among 97 valve replacement cases 3 were Ebstein anomaly treated with plication and tricuspid valve replacement. Operative mortality rate for congenital anomaly was 10.6%, with 2.7% for acyanotic and 22.4% for cyanotic group. For acquired lesions over all operative mortality was 7%. Tetralogy of Fallot, ventricular septal defect, and atrial septal defect were the 3 main congenital anomalies, with 88 cues, 69 cases, and 27 cues respectively. In 61 simple ventricular septal defect without other anomalies operative mortality rate was 1.6%, in 27 atrial septal defect no death and, in tetralogy of Fallot 12.2%. Among 69 ventricular septal defect cases 19[27.5%] type I VSDs, after Kirklin-Becu classification, were found, rather high relative incidence of type I compared with Caucasian patients. Among 97 valve replacement cases 20 double valves were replaced-11 mitral with aortic and 9 mitral with tricuspid valves. Over all operative mortality rate for valve replacement was 8.2% with 3.3% in 61 mitral valve replace-merit. The over all operative mortality rate for 320 open heart surgery cases was 10.6%. Bubble type oxygenator and xenograft bioprosthetic valves were utilized In almost all cases.

  • PDF

Hemodynamic evaluation of the Ionescu-Shiley pericardial xenograft heart valve (Ionescue-Shiley 인조판막을 이용한 판막대치술의 혈류역학적 성적)

  • Jeong, Won-Sang;Kim, Geun-Ho
    • Journal of Chest Surgery
    • /
    • v.17 no.2
    • /
    • pp.223-230
    • /
    • 1984
  • Since January 1977 to the end of September 1982, total 60 Ionescu-Shiley pericardial xenograft heart valves were implanted for valve replacement in 50 patients at the Han Yang University Hospital. The operative procedures were as follow: Mitral valve replacement [MVR] in 25 patients, Mitral valve replacement [MVR] and Tricuspid valve [TV] annuloplasty in 7 patients, Aortic valve replacement [AVR] in 8 patients, Aortic valve replacement [AVR] and Mitral valve replacement [MVR] in 8 patients. Aortic valve replacement [AVR] and Mitral valve replacement [MVR] and Tricuspid valve [TV] annuloplasty in 2 patients. To evaluate the immediate hemodynamic changes after valve replacements, the pressures of each cardiac chamber and ulmonary artery were checked before and after valve replacement on the operation table. Right ventricle [RV] pressure was decreased from 52.09\ulcorner6.71 to 45.57\ulcorner5.03 mmHg, Pulmonary artery [PA] pressure was decreased from 45.97\ulcorner2.69 to 41.00\ulcorner3.99 mmHg, and Left atrium [LA] pressure was decreased from 30.33\ulcorner13.02 to 22.76\ulcorner.97 mmHg before and after valve replacement. In MVR group, RV pressure was decreased from 49.17\ulcorner7.89 to 43.14\ulcorner4.14 mmHg, PA pressure was decreased from 44.67\ulcorner3.18 to 38.67\ulcorner2.85 mmHg, and LA pressure was decreased from 31.46\ulcorner13.47 to 21.91\ulcorner.17 mmHg. In AVR group, RV pressure was decreased from 53.0\ulcorner7.44 to 44.71 \ulcorner3.24 mmHg, PA pressure was decreased from 34.83\ulcorner0.73 to 31.86\ulcorner.36 mmHg, and LA pressure was not changed. In double valve replacement [MVR and AVR] group, RV pressure was decreased from 57.50\ulcorner3.82 to 42.50\ulcorner.80 mmHg, PA pressure was decreased from 51.17\ulcorner1.42 to 43.33\ulcorner4.53mmHig, and LA pressure was decreased from 34.33\ulcorner2.09 to 25.50\ulcorner0.21 mmHg. But in the group where MVR and TV annuloplasty were performed, preoperative RV and PA pressure were markedly increased and no pressure decrease in RV and PA noticed after valve replacement. This study shows good immediate postoperative hemodynamic results after valve replacement using Ionescu-Shiley xenograft valve except in the cases of MVR and TV annuloplasty and advanced disease with pulmonary hypertension.

  • PDF

Severe Tricuspid Regurgitation Following Blunt Chest Trauma : Successful Repair by PTFE Chordal Replacement and Ring Annuloptasty (흉부외상후 발생한 삼첨판막 역류증에 있어서 새로운 건삭형성 및 판막링을 이용한 판막성형술 - 1례보고 -)

  • 원태희;원용순
    • Journal of Chest Surgery
    • /
    • v.30 no.5
    • /
    • pp.533-536
    • /
    • 1997
  • We report a successful repair of severe traumatic tricuspid regurgitation by PTFE chordal replacement and ring annuloplasty. A 64-year-old man with multiple trauma was referred to our department because of cardiomegaly on chest roentgenogram. Echocardiography showed moderate amount of pericardial effusion and severe tricuspid regurgitation with rupture of anterior papillary muscle. But he experienced progressive dyspnea, and chest roentgenogram showed pro ressive cardiomegaly. He underwent operation 4 months after trauma. The nterior papillary muscle was reinserted, and the valve was repaired by PTFE chordal replacements and ring annuloplasty. Postoperatively, the patient's functional status was improved, and there was trivial tricuspid regurgitation on echocardiographic examination.

  • PDF

Clinical Experiences of St. Jude Medical Cardiac Valve Replacement (St. Jude Medical valve의 임상적 고찰)

  • 김종원
    • Journal of Chest Surgery
    • /
    • v.25 no.5
    • /
    • pp.518-525
    • /
    • 1992
  • 50 months experience with St-Jude Medical Cardiac Valve Prosthesis The St. Jude Medical valve has become our mechanical valvular prosthesis of choice because of favorable hemodynamic results that associated with marked clinical improvement and low incidence of thromboembolism. The data for this study was collected from April 1986 to May 1990, four years period. There were total of 110 patients[female 53, male 58] in this series with 22 isolated aortic valve, 66 isolated mitral valve, 20 double valve, 2 tricuspid valve replacement. The mean follow up time was 23 months. Postoperatively, 77% of cases were in New York Heart Association[NYHA] functional class I, and mild and moderate symptoms[NYHA II ] were present in 20% and there were very few patients remaining in higher functional classifications. In postoperative echocardiographic study showed marked improved cardiac function. The overall early mortality was 5.4% and was higher after double[13.3%] and mitral valve replacement[5.6%] and the late mortality was one case after mitral valve replacement due to endocarditis. The cause of death in early mortality was attributed to heart failure, acute renal failure, sepsis, etc.

  • PDF

Surgical Treatment of Isolated Primary Tricuspid Insufficiency except Ebstein`s Anomaly - Report of 2 Cases - (Ebstein`s anomaly 이외의 격리성 원발성 삼천판 부전증[isolated primary tricuspid insufficiency]의 수술 치험 2례)

  • Baik, Hee-Jong;Ahn, Hyuk
    • Journal of Chest Surgery
    • /
    • v.24 no.9
    • /
    • pp.907-912
    • /
    • 1991
  • Isolated primary tricuspid insufficiency except Ebstein`s anomaly is rare disease. Recently we experienced two cases of isolated primary tricuspid insufficiency and treated successfully with annuloplasty or valve replacement. We could not classify our case as one of the classification of isolated tricuspid insufficiency, because the morphology and microscopic finding did not suggest any similar variety.

  • PDF

Mitral Valve Replacement Via an Extended Transseptal Approach (광범위 경중격 좌심방절개술에 의한 승모판막치환술)

  • 정수상
    • Journal of Chest Surgery
    • /
    • v.28 no.6
    • /
    • pp.579-582
    • /
    • 1995
  • The extended transseptal approach to the mitral valve replacement has been used for 30 patients. There were 19 women and 11 men. Twenty five patients had rheumatic heart disease, 4 had degenerative valve ,and 1 had valve prolapse. Fifteen of 30 patients had other associated procedure; 10 had aortic valve replacement; 5 had tricuspid annuloplasty. There were no postoperative complications associated with the approaches, ie, no bleeding, no sinus node dysfuction, and no atrioventricular conduction disturbance. Despite division of the sinus node artery, preoperative atrial rhythms[3 sinus rhythms and 27 atrial fibrillations were not changed during postoperative period. The extended transseptal approach provides good mitral valve exposure without inherent complications, and is superior to that of standard approach, so we use it routinely for mitral valve procedure.

  • PDF